期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Temperature rise induced by an annular focused transducer with a wide aperture angle in multi-layer tissue
1
作者 戚萌 刘杰惠 +1 位作者 毛一葳 刘晓宙 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第1期390-395,共6页
In order to improve the operability and accuracy of high-intensity focused ultrasound (HIFU), an annular focused transducer, whereby a B-ultrasound probe is placed in its center, is used to realize the real time mon... In order to improve the operability and accuracy of high-intensity focused ultrasound (HIFU), an annular focused transducer, whereby a B-ultrasound probe is placed in its center, is used to realize the real time monitoring and control of the treatment. In this paper, the spheroidal beam equation (SBE) was used to calculate the sound lield by an annular focused transducer with a wide aperture angle to first derive the heat deposition and the Pennes equation was used to calculate the temperature field in multi-layer tissue. We studied the effect of different parameters on the temperature of the tissues. The result shows that the focal length has a significant influence on both maximum liver temperature rise and skin temperature rise, and both increase with the increase in the focal length. When the frequency increases, the temperature rise first undergoes a rapid increase before gradually reaching a maximum, and then finally decreasing. The temperature rise increases while the inner radius decreases or the sound pressure increases. By choosing suitable parameters, the proper temperature rise both on the target tissue and skin via an annular tbcused transducer with a wide aperture angle can be obtained. 展开更多
关键词 spheroidal beam equation annular focused transducer multi-layer tissue temperature field
在线阅读 下载PDF
Reflection-mode photoacoustic microscopy using a hollow focused ultrasound transducer for in vivo imaging of blood vessels
2
作者 袁毅 杨思华 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第5期283-287,共5页
A reflection-mode photoacoustic microscope using a hollow focused ultrasound transducer is developed for highresolution in vivo imaging.A confocal structure of the laser and the ultrasound is used to improve the syste... A reflection-mode photoacoustic microscope using a hollow focused ultrasound transducer is developed for highresolution in vivo imaging.A confocal structure of the laser and the ultrasound is used to improve the system resolution.The axial and lateral resolutions of the system are measured to be ~ 32 μm and ~ 58 μm,respectively.Ex vivo and in vivo modes are tested to validate the imaging capability of the photoacoustic microscope.The adjacent vein and artery can be seen clearly from the reconstructed photoacoustic images.The results demonstrate that the reflectionmode photoacoustic microscope can be used for high-resolution imaging of micro-blood vessels,which would be of great benefit for monitoring the neovascularization in tumor angiogenesis. 展开更多
关键词 photoacoustic microscopy hollow focused ultrasound transducer blood vessels
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部