This paper analyzes the situation at the Iffezheim barrage along the fiver Rhine.Since the start of operation in 1977 several million cubic meters of very fine sediment have been deposited in the reservoir.Be- cause o...This paper analyzes the situation at the Iffezheim barrage along the fiver Rhine.Since the start of operation in 1977 several million cubic meters of very fine sediment have been deposited in the reservoir.Be- cause of stability problems and reduced safety in the event of flooding,an extraction of the material is neces- sary.Chemical assays showed a high concentration of HCB.Therefore flushing without any additional measures is not appropriate.In order to leam more about the morphological and chemical in...展开更多
针对先进高性能飞行器对高精度大气数据的测控需求,研发设计了一套适用于亚声速飞行器的嵌入式大气数据传感(flush air data sensing,FADS)系统。该系统首先基于数值建模技术建立了FADS系统模型的压力数据库,并针对建模数据精度及风洞...针对先进高性能飞行器对高精度大气数据的测控需求,研发设计了一套适用于亚声速飞行器的嵌入式大气数据传感(flush air data sensing,FADS)系统。该系统首先基于数值建模技术建立了FADS系统模型的压力数据库,并针对建模数据精度及风洞试验校准数据分析了Ma=0.2~0.4对应的压力误差限;其次,开发了攻角实时解算算法,并集成到工程原理样机中;最后基于风洞试验和飞行试验对FADS系统的实时解算算法及样机进行了系统评估,并通过事后模型算法对攻角进行重新解算以评估攻角实时解算算法的可靠性。结果表明:(1)与机载惯性导航系统等其他独立测试系统解算的数据相比,飞行试验中FADS系统采用的攻角实时解算方法精度整体较好,攻角误差小于1°,在关键段小于0.5°;基于不同模型建立的FADS系统攻角解算方法得到的攻角数值基本一致,证实了开发的实时解算算法的可靠性。(2)基于风洞试验及飞行试验数据对算法误差限的考核结果显示,飞行试验初始阶段实时解算的攻角值产生波动是压力输入波动误差限较大造成的,高空低速时的压力波动幅值大是实时解算攻角值偏差较大的主要原因;建立的FADS系统的攻角解算方法在算法误差限范围内的压力波动对攻角解算值影响较小,但超过算法误差限的压力波动对攻角解算值影响显著。高空低速飞行器FADS系统对测压传感器精度水平及工程实施水平要求较高,在实际工程应用中应尽量保证测压传感器的精度水平。展开更多
目的总结经皮肝穿刺胆道引流术(percutaneous transhepatic biliary drainage,PTBD)后患者引流管冲洗相关证据,形成系统化的PTBD引流管冲洗流程,为临床护理提供循证依据。方法系统检索Cochrane Library、Web of Science、PubMed、Embase...目的总结经皮肝穿刺胆道引流术(percutaneous transhepatic biliary drainage,PTBD)后患者引流管冲洗相关证据,形成系统化的PTBD引流管冲洗流程,为临床护理提供循证依据。方法系统检索Cochrane Library、Web of Science、PubMed、Embase、UpToDate、BMJ Best Practice、CNKI、万方等多个数据库,汇总关于PTBD后引流管冲洗的证据,包括指南、证据总结、系统评价、专家共识及原始研究。检索时间为建库至2024年3月。结果共纳入8篇文献。最终从人员资质、冲洗时机、冲洗液选择、冲洗方法、注意事项、健康指导6个方面总结出18条最佳证据。结论该研究系统检索了国内外有关PTBD后引流管冲洗相关证据,并对证据进行评价、提取汇总成最佳证据,规范了PTBD引流管冲洗方法,可为后期制订标准化的引流管冲洗流程提供参考依据。展开更多
文摘This paper analyzes the situation at the Iffezheim barrage along the fiver Rhine.Since the start of operation in 1977 several million cubic meters of very fine sediment have been deposited in the reservoir.Be- cause of stability problems and reduced safety in the event of flooding,an extraction of the material is neces- sary.Chemical assays showed a high concentration of HCB.Therefore flushing without any additional measures is not appropriate.In order to leam more about the morphological and chemical in...
文摘针对先进高性能飞行器对高精度大气数据的测控需求,研发设计了一套适用于亚声速飞行器的嵌入式大气数据传感(flush air data sensing,FADS)系统。该系统首先基于数值建模技术建立了FADS系统模型的压力数据库,并针对建模数据精度及风洞试验校准数据分析了Ma=0.2~0.4对应的压力误差限;其次,开发了攻角实时解算算法,并集成到工程原理样机中;最后基于风洞试验和飞行试验对FADS系统的实时解算算法及样机进行了系统评估,并通过事后模型算法对攻角进行重新解算以评估攻角实时解算算法的可靠性。结果表明:(1)与机载惯性导航系统等其他独立测试系统解算的数据相比,飞行试验中FADS系统采用的攻角实时解算方法精度整体较好,攻角误差小于1°,在关键段小于0.5°;基于不同模型建立的FADS系统攻角解算方法得到的攻角数值基本一致,证实了开发的实时解算算法的可靠性。(2)基于风洞试验及飞行试验数据对算法误差限的考核结果显示,飞行试验初始阶段实时解算的攻角值产生波动是压力输入波动误差限较大造成的,高空低速时的压力波动幅值大是实时解算攻角值偏差较大的主要原因;建立的FADS系统的攻角解算方法在算法误差限范围内的压力波动对攻角解算值影响较小,但超过算法误差限的压力波动对攻角解算值影响显著。高空低速飞行器FADS系统对测压传感器精度水平及工程实施水平要求较高,在实际工程应用中应尽量保证测压传感器的精度水平。
文摘目的总结经皮肝穿刺胆道引流术(percutaneous transhepatic biliary drainage,PTBD)后患者引流管冲洗相关证据,形成系统化的PTBD引流管冲洗流程,为临床护理提供循证依据。方法系统检索Cochrane Library、Web of Science、PubMed、Embase、UpToDate、BMJ Best Practice、CNKI、万方等多个数据库,汇总关于PTBD后引流管冲洗的证据,包括指南、证据总结、系统评价、专家共识及原始研究。检索时间为建库至2024年3月。结果共纳入8篇文献。最终从人员资质、冲洗时机、冲洗液选择、冲洗方法、注意事项、健康指导6个方面总结出18条最佳证据。结论该研究系统检索了国内外有关PTBD后引流管冲洗相关证据,并对证据进行评价、提取汇总成最佳证据,规范了PTBD引流管冲洗方法,可为后期制订标准化的引流管冲洗流程提供参考依据。