The surfactant additive octadecylamine (ODA) was used to enhance the flow boiling heat transfer of water in vertical copper tube, and the effects of the aqueous solution properties, mass fraction of ODA, mass flux and...The surfactant additive octadecylamine (ODA) was used to enhance the flow boiling heat transfer of water in vertical copper tube, and the effects of the aqueous solution properties, mass fraction of ODA, mass flux and heat flux etc. on flow boiling heat transfer were investigated. In order to analyze the mechanism of enhancement on boiling heat transfer with ODA, the copper surface was detected by XPS, and the diagram of binding energy was obtained. The results show that ODA can be adsorbed on the surface of the copper wall, and affects the properties of the heating surfaces and enhances the flow boiling heat transfer of water. Only in low heat flux and in a suitable range of concentration, can ODA aqueous solution enhance flow boiling heat transfer, and the suitable mass fraction of ODA is in the range of 1×10 -5 5×10 -5 . In addition, compared with water, ODA aqueous solution does not increase the flow drag under the same experimental conditions.展开更多
The drag reducing effect of polymer additive aqueous solution was investigated in flow boiling, and the polymer additives were two kinds of polyacrylamide (PAM) with relative molecular mass about 2.56×10 6 and 8....The drag reducing effect of polymer additive aqueous solution was investigated in flow boiling, and the polymer additives were two kinds of polyacrylamide (PAM) with relative molecular mass about 2.56×10 6 and 8.55×10 6. The frictional pressure drop was calculated according to the measured total pressure drop. The results show that the flow drag of flow boiling is reduced by adding a small amount of PAM to water when heat flux is in the range of 15.1 kW·m -2 to 47.0 kW·m -2 , when the mass fraction of PAM is higher than 2.0×10 -5 , the drag reducing effect is obvious. Drag reducing effect of PAM, whose relative molecular mass is 8.55×10 6, is slightly better than that of 2.56×10 6 at the same mass fraction, and the greater the flow rate of the additive solution, the better the effect of the drag reduction.展开更多
The boiling heat transfer of evaporation cooling in a billet reheating furnace was simulated.The results indicate that the bubbles easily aggregate inside of the elbow and upper side of the horizontal regions in theπ...The boiling heat transfer of evaporation cooling in a billet reheating furnace was simulated.The results indicate that the bubbles easily aggregate inside of the elbow and upper side of the horizontal regions in theπshaped support tubes.The circulation velocity increasing helps to improve the uniformity of vapor distribution and decrease the difference of vapor volume fraction between upper and down at end of the horizontal sections.With the increase of circulation velocity,the resistance loss and the circulation ratio both increase,but the former will decrease with the increase of work pressure.展开更多
基金The Natural Science Foundation of Tianjin(No.94220)
文摘The surfactant additive octadecylamine (ODA) was used to enhance the flow boiling heat transfer of water in vertical copper tube, and the effects of the aqueous solution properties, mass fraction of ODA, mass flux and heat flux etc. on flow boiling heat transfer were investigated. In order to analyze the mechanism of enhancement on boiling heat transfer with ODA, the copper surface was detected by XPS, and the diagram of binding energy was obtained. The results show that ODA can be adsorbed on the surface of the copper wall, and affects the properties of the heating surfaces and enhances the flow boiling heat transfer of water. Only in low heat flux and in a suitable range of concentration, can ODA aqueous solution enhance flow boiling heat transfer, and the suitable mass fraction of ODA is in the range of 1×10 -5 5×10 -5 . In addition, compared with water, ODA aqueous solution does not increase the flow drag under the same experimental conditions.
文摘The drag reducing effect of polymer additive aqueous solution was investigated in flow boiling, and the polymer additives were two kinds of polyacrylamide (PAM) with relative molecular mass about 2.56×10 6 and 8.55×10 6. The frictional pressure drop was calculated according to the measured total pressure drop. The results show that the flow drag of flow boiling is reduced by adding a small amount of PAM to water when heat flux is in the range of 15.1 kW·m -2 to 47.0 kW·m -2 , when the mass fraction of PAM is higher than 2.0×10 -5 , the drag reducing effect is obvious. Drag reducing effect of PAM, whose relative molecular mass is 8.55×10 6, is slightly better than that of 2.56×10 6 at the same mass fraction, and the greater the flow rate of the additive solution, the better the effect of the drag reduction.
基金Project(51171041) supported by the National Natural Science Foundation of China
文摘The boiling heat transfer of evaporation cooling in a billet reheating furnace was simulated.The results indicate that the bubbles easily aggregate inside of the elbow and upper side of the horizontal regions in theπshaped support tubes.The circulation velocity increasing helps to improve the uniformity of vapor distribution and decrease the difference of vapor volume fraction between upper and down at end of the horizontal sections.With the increase of circulation velocity,the resistance loss and the circulation ratio both increase,but the former will decrease with the increase of work pressure.