Recent advancements have led to the synthesis of various new metal-containing explosives,particularly energetic metal-organic frameworks(EMOFs),which feature high-energy ligands within well-ordered crystalline structu...Recent advancements have led to the synthesis of various new metal-containing explosives,particularly energetic metal-organic frameworks(EMOFs),which feature high-energy ligands within well-ordered crystalline structures.These explosives exhibit significant advantages over traditional compounds,including higher density,greater heats of detonation,improved mechanical hardness,and excellent thermal stability.To effectively evaluate their detonation performance,it is crucial to have a reliable method for predicting detonation heat,velocity,and pressure.This study leverages experimental data and outputs from the leading commercial computer code to identify suitable decomposition pathways for different metal oxides,facilitating straightforward calculations for the detonation performance of alkali metal salts,and metal coordination compounds,along with EMOFs.The new model enhances predictive reliability for detonation velocities,aligning more closely with experimental results,as evi-denced by a root mean square error(RMSE)of 0.68 km/s compared to 1.12 km/s for existing methods.Furthermore,it accommodates a broader range of compounds,including those containing Sr,Cd,and Ag,and provides predictions for EMOFs that are more consistent with computer code outputs than previous predictive models.展开更多
A method for simultaneous determination of nine cations including Fe 3+, Cu 2+, Ni 2+, Zn 2+, Co 2+, Fe 2+, Cd 2+, Mg 2+ and Ca 2+ by single-column ion chromatography with a conductivity detector was developed. The op...A method for simultaneous determination of nine cations including Fe 3+, Cu 2+, Ni 2+, Zn 2+, Co 2+, Fe 2+, Cd 2+, Mg 2+ and Ca 2+ by single-column ion chromatography with a conductivity detector was developed. The optimum composition of eluent was 6 mmol/L malic acid and 3 mmol/L ethylenediamine(pH=4 0). The effects of malic acid concentration, ethylenediamine concentration and pH value on retention time were studied in details. The method was used to determine Fe, Cu, Zn, Mg and Ca in whole blood and serum with satisfactory results.展开更多
基金the research committee at Malek Ashtar University of Technology (MUT) for their invaluable support of this project
文摘Recent advancements have led to the synthesis of various new metal-containing explosives,particularly energetic metal-organic frameworks(EMOFs),which feature high-energy ligands within well-ordered crystalline structures.These explosives exhibit significant advantages over traditional compounds,including higher density,greater heats of detonation,improved mechanical hardness,and excellent thermal stability.To effectively evaluate their detonation performance,it is crucial to have a reliable method for predicting detonation heat,velocity,and pressure.This study leverages experimental data and outputs from the leading commercial computer code to identify suitable decomposition pathways for different metal oxides,facilitating straightforward calculations for the detonation performance of alkali metal salts,and metal coordination compounds,along with EMOFs.The new model enhances predictive reliability for detonation velocities,aligning more closely with experimental results,as evi-denced by a root mean square error(RMSE)of 0.68 km/s compared to 1.12 km/s for existing methods.Furthermore,it accommodates a broader range of compounds,including those containing Sr,Cd,and Ag,and provides predictions for EMOFs that are more consistent with computer code outputs than previous predictive models.
基金supported by National Natural Science Foundation of China(52206232)Jiangsu Agricultural Science and Technology Innovation Fund(CX(23)3049)Key University Science Research Project of Jiangsu province(21KJA610001).
文摘A method for simultaneous determination of nine cations including Fe 3+, Cu 2+, Ni 2+, Zn 2+, Co 2+, Fe 2+, Cd 2+, Mg 2+ and Ca 2+ by single-column ion chromatography with a conductivity detector was developed. The optimum composition of eluent was 6 mmol/L malic acid and 3 mmol/L ethylenediamine(pH=4 0). The effects of malic acid concentration, ethylenediamine concentration and pH value on retention time were studied in details. The method was used to determine Fe, Cu, Zn, Mg and Ca in whole blood and serum with satisfactory results.