Factors influencing the signal-to-noise ratio (SNR) of lensless ghost interference with thermal incoherent light are investigated. Our result shows that the SNR of lensless ghost interference is related to the trans...Factors influencing the signal-to-noise ratio (SNR) of lensless ghost interference with thermal incoherent light are investigated. Our result shows that the SNR of lensless ghost interference is related to the transverse length of the object, the position of the object in the imaging system and the transverse size of the light source. Furthermore, the effects of these factors on the SNR are discussed in detail by numerical simulations.展开更多
We constructed a 36-channel magnetocardiography(MCG) system based on low-Tc direct current(DC) superconducting quantum interference device(SQUID) magnetometers operated inside a magnetically shielded room(MSR)...We constructed a 36-channel magnetocardiography(MCG) system based on low-Tc direct current(DC) superconducting quantum interference device(SQUID) magnetometers operated inside a magnetically shielded room(MSR). Weakly damped SQUID magnetometers with large Steward–Mc Cumber parameter βc(βc≈ 5), which could directly connect to the operational amplifier without any additional feedback circuit, were used to simplify the readout electronics. With a flux-to-voltage transfer coefficient V / Φ larger than 420 μV/Φ0, the SQUID magnetometers had a white noise level of about 5.5 f T·Hz-1/2when operated in MSR. 36 sensing magnetometers and 15 reference magnetometers were employed to realize software gradiometer configurations. The coverage area of the 36 sensing magnetometers is 210×210 mm2. MCG measurements with a high signal-to-noise ratio of 40 d B were done successfully using the developed system.展开更多
A generalized approach for narrowband interference (NBI) suppression in direct sequence spread spectrum (DSSS) communication systems using adaptive infinite impulse response (IIR) filter is presented. The excisi...A generalized approach for narrowband interference (NBI) suppression in direct sequence spread spectrum (DSSS) communication systems using adaptive infinite impulse response (IIR) filter is presented. The excision filter coefficients depend on both the jammer power and its instantaneous frequency. The dependency of the filter construction on the jammer power is significant as it allows optimal tradeoff between interference removal and signal distortion by maximizing the receiver signal to noise ratio improvement(SNRI). Instead of traditional adaptive line enhancer (ALE) estimator, a preferable NBI estimator-Fourier interpolation estimator (FIE) is proposed. Closed-form expressions of the SNR improvement and theoretical bit error rate (BER) based on the assumption that the output of the correlator is Gaussian distributed are both derived. Performance results obtained by numerical simulation are also presented and compared with theoretical results.展开更多
Ambient noise in 13 sawinill’s workshops was tested and analyzed to reveal its character and regularity. The situation of the ambient noise in sawimill s workshops was evaluated.
基金supported by the National Natural Science Foundation of China (Grant Nos. 11074307 and 10774192)the Opening Research Foundation of State Key Laboratory of Precision Spectroscopy,ECNU
文摘Factors influencing the signal-to-noise ratio (SNR) of lensless ghost interference with thermal incoherent light are investigated. Our result shows that the SNR of lensless ghost interference is related to the transverse length of the object, the position of the object in the imaging system and the transverse size of the light source. Furthermore, the effects of these factors on the SNR are discussed in detail by numerical simulations.
基金Project supported by"One Hundred Persons Project"of the Chinese Academy of Sciences and the Strategic Priority Research Program(B)of the Chinese Academy of Sciences(Grant No.XDB04020200)
文摘We constructed a 36-channel magnetocardiography(MCG) system based on low-Tc direct current(DC) superconducting quantum interference device(SQUID) magnetometers operated inside a magnetically shielded room(MSR). Weakly damped SQUID magnetometers with large Steward–Mc Cumber parameter βc(βc≈ 5), which could directly connect to the operational amplifier without any additional feedback circuit, were used to simplify the readout electronics. With a flux-to-voltage transfer coefficient V / Φ larger than 420 μV/Φ0, the SQUID magnetometers had a white noise level of about 5.5 f T·Hz-1/2when operated in MSR. 36 sensing magnetometers and 15 reference magnetometers were employed to realize software gradiometer configurations. The coverage area of the 36 sensing magnetometers is 210×210 mm2. MCG measurements with a high signal-to-noise ratio of 40 d B were done successfully using the developed system.
基金Sponsored by the Beijing Municipal Natural Science Foundation(4052024)
文摘A generalized approach for narrowband interference (NBI) suppression in direct sequence spread spectrum (DSSS) communication systems using adaptive infinite impulse response (IIR) filter is presented. The excision filter coefficients depend on both the jammer power and its instantaneous frequency. The dependency of the filter construction on the jammer power is significant as it allows optimal tradeoff between interference removal and signal distortion by maximizing the receiver signal to noise ratio improvement(SNRI). Instead of traditional adaptive line enhancer (ALE) estimator, a preferable NBI estimator-Fourier interpolation estimator (FIE) is proposed. Closed-form expressions of the SNR improvement and theoretical bit error rate (BER) based on the assumption that the output of the correlator is Gaussian distributed are both derived. Performance results obtained by numerical simulation are also presented and compared with theoretical results.
文摘Ambient noise in 13 sawinill’s workshops was tested and analyzed to reveal its character and regularity. The situation of the ambient noise in sawimill s workshops was evaluated.