An upwind finite element(FE)based algorithm to calculate the ion flow field in the vicinity of multi-circuit DC transmission lines is described.The initial value estimation and boundary condition are optimized,so deta...An upwind finite element(FE)based algorithm to calculate the ion flow field in the vicinity of multi-circuit DC transmission lines is described.The initial value estimation and boundary condition are optimized,so details of the transmission lines such as bundle conductors and ground wires can be taken into account in the simulation model.Comparison between measured and computed ground level total electrical field and ion current density shows satisfactory agreement.The ion flow field of a ±500 kV HVDC project with bipolar lines on the same tower is simulated.The total electrical field and ion current density on ground level are compared among different line arrangements.展开更多
The study of the electric field around a surge arrester is useful for design procedures and diagnostic tests. The current work com- putes the electric field around a medium voltage gapless surge arrester using 2D and ...The study of the electric field around a surge arrester is useful for design procedures and diagnostic tests. The current work com- putes the electric field around a medium voltage gapless surge arrester using 2D and 3D representation of the arrester. The 2D simulation design, which is described in IEC 60099-4 Standard, cannot include the non symmetrical parts of the arrester geometry and the test arrange- ment. 3D simulation procedures have the advantage that takes into account these asymmetries, giving more accurate results for each measurement position. In order to confirm the suitability of the created models, the simulation results of the electric field, using the 2D and 3D edition of PC Opera, are compared with recorded measurements, which are obtained in laboratory using appropriate calibrated field meters.展开更多
基金Project Supported by China11th Five-year National Key Technologies R&D Program(2006BAA02A20)
文摘An upwind finite element(FE)based algorithm to calculate the ion flow field in the vicinity of multi-circuit DC transmission lines is described.The initial value estimation and boundary condition are optimized,so details of the transmission lines such as bundle conductors and ground wires can be taken into account in the simulation model.Comparison between measured and computed ground level total electrical field and ion current density shows satisfactory agreement.The ion flow field of a ±500 kV HVDC project with bipolar lines on the same tower is simulated.The total electrical field and ion current density on ground level are compared among different line arrangements.
文摘The study of the electric field around a surge arrester is useful for design procedures and diagnostic tests. The current work com- putes the electric field around a medium voltage gapless surge arrester using 2D and 3D representation of the arrester. The 2D simulation design, which is described in IEC 60099-4 Standard, cannot include the non symmetrical parts of the arrester geometry and the test arrange- ment. 3D simulation procedures have the advantage that takes into account these asymmetries, giving more accurate results for each measurement position. In order to confirm the suitability of the created models, the simulation results of the electric field, using the 2D and 3D edition of PC Opera, are compared with recorded measurements, which are obtained in laboratory using appropriate calibrated field meters.