Facing the problems lack of considering the non-uniform distribution of the static bias magnetic field and computing the panicle displacements in the simulation model of electromagnetic acoustic transducer (EMAT), a...Facing the problems lack of considering the non-uniform distribution of the static bias magnetic field and computing the panicle displacements in the simulation model of electromagnetic acoustic transducer (EMAT), a multi-field coupled model was established and the finite element method (FEM) was presented to calculate the entire transduction process. The multi-field coupled model included the static magnetic field, pulsed eddy current field and mechanical field. The FEM equations of the three fields were derived by Garlerkin FEM method. Thus, the entire transduction process of the EMAT was calculated through sequentially coupling the three fields. The transduction process of a Lamb wave EMAT was calculated according to the present model and method. The results show that, by the present method, it is valid to calculate the particle displacement under the given excitation signal and non-uniformly distributed static magnetic field. Calculation error will be brought about if the non-uniform distribution of the static bias magnetic field is neglected.展开更多
The work principle of all fiber optical current transducer (AFOCT) was introduced. By analyzing the characteristic of photo-detector's output, a measurement and signal processing scheme based on sine wave modulati...The work principle of all fiber optical current transducer (AFOCT) was introduced. By analyzing the characteristic of photo-detector's output, a measurement and signal processing scheme based on sine wave modulation and demodulation was put forward for eliminating the influence of light intensity change and modulation degree change. A digital signal processing system and a calibration scheme were also advanced. The experimental data show that the mean ratio error is 0.016 74% for direct current and 0.035% for alternating current, and the correlation coefficient of linearity is up to 0.999 982 4, meeting the precision requirement of 0.2 grade. Stability experiments and temperature drift experiments show the AFOCT has a better stable capability.展开更多
A focused ultrasonic transducer used for biomedical purposes with a fundamental frequency of 10MHz and a pulse width of one and a half periods is described in this paper. Its physical properties are given including (1...A focused ultrasonic transducer used for biomedical purposes with a fundamental frequency of 10MHz and a pulse width of one and a half periods is described in this paper. Its physical properties are given including (1) focused acoustic field recorded by an optical means, (2) electric waveform for triggering the transducer and the corresponding waveform of the wave received by another transducer, and (3) result of tests on a sample object.展开更多
High intensity focused ultrasound(HIFU)therapy is an effective method in clinical treatment of tumors,in order to explore the bio-heat conduction mechanism of in multi-layer media by concave spherical transducer,tempe...High intensity focused ultrasound(HIFU)therapy is an effective method in clinical treatment of tumors,in order to explore the bio-heat conduction mechanism of in multi-layer media by concave spherical transducer,temperature field induced by this kind of transducer in multi-layer media will be simulated through solving Pennes equation with finite difference method,and the influence of initial sound pressure,absorption coefficient,and thickness of different layers of biological tissue as well as thermal conductivity parameter on sound focus and temperature distribution will be analyzed,respectively.The results show that the temperature in focus area increases faster while the initial sound pressure and thermal conductivity increase.The absorption coefficient is smaller,the ultrasound intensity in the focus area is bigger,and the size of the focus area is increasing.When the thicknesses of different layers of tissue change,the focus position changes slightly,but the sound intensity of the focus area will change obviously.The temperature in focus area will rise quickly before reaching a threshold,and then the temperature will keep in the threshold range.展开更多
Measurement of nonlinearity parameter using the second-harmonic reflective model is studied. A new kind of compound transducer is designed and fabricated for this purpose. With this transducer and the finite amplitude...Measurement of nonlinearity parameter using the second-harmonic reflective model is studied. A new kind of compound transducer is designed and fabricated for this purpose. With this transducer and the finite amplitude insert-substitution method, an experimental system to measure the nonlinearity parameter using reflective model is developed. B/A values of some liquids and biological tissues are obtained and results coincide well with those presented in the literatures.展开更多
The monitoring of cutting force in a vibration cutting process has a great significance in the popularization of ultrasonic vibration cutting technology. A new monitoring method of which the cutting force of ultrasoni...The monitoring of cutting force in a vibration cutting process has a great significance in the popularization of ultrasonic vibration cutting technology. A new monitoring method of which the cutting force of ultrasonic elliptic vibration cutting is monitored using the electrical properties of transducer was proposed by studying on the relationship of cutting force, transducer electric impedance and load. A measurement system was designed for the electrical properties of transducer. The feasibility of cutting force monitoring method based on the electrical properties of piezoelectric transducer was proved by the cutting experiments.展开更多
The compact ortho-mode transducer (OMT) and compact conical corrugated horn(CCCH) are used as feeding system of the deployable dual polarizing antenna in this paper.A new stricture of double-septum in main wave guide ...The compact ortho-mode transducer (OMT) and compact conical corrugated horn(CCCH) are used as feeding system of the deployable dual polarizing antenna in this paper.A new stricture of double-septum in main wave guide OMT is proposed. The finite difference method in time domain (FDTD) in combination with genetic algorithms(GAs) is used to analysis and optimize this new OMT. The experiment results show that the voltage standing wave ratio (VSWR) of this OMT and feeding system is less than 1.17 in bandwidth; the isolation between the ortho-mode ports is less than -40dB; the cross-polar level of the feed can reach -35dB and the length of the main waveguide can be reduced 50% at least.展开更多
Three differential equations based on different definitions of current density are compared. Formulation I is based on an incomplete equation for total current density (TCD). Formulations II and {I1 are based on inc...Three differential equations based on different definitions of current density are compared. Formulation I is based on an incomplete equation for total current density (TCD). Formulations II and {I1 are based on incomplete and complete equations for source current density (SCD), respectively. Using the weak form of finite element method (FEM), three formulations were applied in a spiral coil electromagnetic acoustic transducer (EMAT) example to solve magnetic vector potential (MVP). The input impedances calculated by Formulation III are in excellent agreement with the experimental measurements. Results show that the errors for Formulations I & II vary with coil diameter, coil spacing, lift-off distance and external excitation frequency, for the existence of eddy-current and skin & proximity effects. And the current distribution across the coil conductor also follows the same trend. It is better to choose Formulation I instead of Formulation Ili to solve MVP when the coil diameter is less than twice the skin depth for Formulation I is a low cost and high efficiency calculation method.展开更多
针对先进高性能飞行器对高精度大气数据的测控需求,研发设计了一套适用于亚声速飞行器的嵌入式大气数据传感(flush air data sensing,FADS)系统。该系统首先基于数值建模技术建立了FADS系统模型的压力数据库,并针对建模数据精度及风洞...针对先进高性能飞行器对高精度大气数据的测控需求,研发设计了一套适用于亚声速飞行器的嵌入式大气数据传感(flush air data sensing,FADS)系统。该系统首先基于数值建模技术建立了FADS系统模型的压力数据库,并针对建模数据精度及风洞试验校准数据分析了Ma=0.2~0.4对应的压力误差限;其次,开发了攻角实时解算算法,并集成到工程原理样机中;最后基于风洞试验和飞行试验对FADS系统的实时解算算法及样机进行了系统评估,并通过事后模型算法对攻角进行重新解算以评估攻角实时解算算法的可靠性。结果表明:(1)与机载惯性导航系统等其他独立测试系统解算的数据相比,飞行试验中FADS系统采用的攻角实时解算方法精度整体较好,攻角误差小于1°,在关键段小于0.5°;基于不同模型建立的FADS系统攻角解算方法得到的攻角数值基本一致,证实了开发的实时解算算法的可靠性。(2)基于风洞试验及飞行试验数据对算法误差限的考核结果显示,飞行试验初始阶段实时解算的攻角值产生波动是压力输入波动误差限较大造成的,高空低速时的压力波动幅值大是实时解算攻角值偏差较大的主要原因;建立的FADS系统的攻角解算方法在算法误差限范围内的压力波动对攻角解算值影响较小,但超过算法误差限的压力波动对攻角解算值影响显著。高空低速飞行器FADS系统对测压传感器精度水平及工程实施水平要求较高,在实际工程应用中应尽量保证测压传感器的精度水平。展开更多
基金Project(10974115) supported by the National Natural Science Foundation of China
文摘Facing the problems lack of considering the non-uniform distribution of the static bias magnetic field and computing the panicle displacements in the simulation model of electromagnetic acoustic transducer (EMAT), a multi-field coupled model was established and the finite element method (FEM) was presented to calculate the entire transduction process. The multi-field coupled model included the static magnetic field, pulsed eddy current field and mechanical field. The FEM equations of the three fields were derived by Garlerkin FEM method. Thus, the entire transduction process of the EMAT was calculated through sequentially coupling the three fields. The transduction process of a Lamb wave EMAT was calculated according to the present model and method. The results show that, by the present method, it is valid to calculate the particle displacement under the given excitation signal and non-uniformly distributed static magnetic field. Calculation error will be brought about if the non-uniform distribution of the static bias magnetic field is neglected.
文摘The work principle of all fiber optical current transducer (AFOCT) was introduced. By analyzing the characteristic of photo-detector's output, a measurement and signal processing scheme based on sine wave modulation and demodulation was put forward for eliminating the influence of light intensity change and modulation degree change. A digital signal processing system and a calibration scheme were also advanced. The experimental data show that the mean ratio error is 0.016 74% for direct current and 0.035% for alternating current, and the correlation coefficient of linearity is up to 0.999 982 4, meeting the precision requirement of 0.2 grade. Stability experiments and temperature drift experiments show the AFOCT has a better stable capability.
文摘A focused ultrasonic transducer used for biomedical purposes with a fundamental frequency of 10MHz and a pulse width of one and a half periods is described in this paper. Its physical properties are given including (1) focused acoustic field recorded by an optical means, (2) electric waveform for triggering the transducer and the corresponding waveform of the wave received by another transducer, and (3) result of tests on a sample object.
基金Project(11174077)supported by the National Natural Science Foundation of ChinaProject(11JJ3079)supported by the Hunan Provincial Natural Science Foundation of ChinaProjects(12C0237,11C0844)supported by the Science Research Program of Education Department of Hunan Province,China
文摘High intensity focused ultrasound(HIFU)therapy is an effective method in clinical treatment of tumors,in order to explore the bio-heat conduction mechanism of in multi-layer media by concave spherical transducer,temperature field induced by this kind of transducer in multi-layer media will be simulated through solving Pennes equation with finite difference method,and the influence of initial sound pressure,absorption coefficient,and thickness of different layers of biological tissue as well as thermal conductivity parameter on sound focus and temperature distribution will be analyzed,respectively.The results show that the temperature in focus area increases faster while the initial sound pressure and thermal conductivity increase.The absorption coefficient is smaller,the ultrasound intensity in the focus area is bigger,and the size of the focus area is increasing.When the thicknesses of different layers of tissue change,the focus position changes slightly,but the sound intensity of the focus area will change obviously.The temperature in focus area will rise quickly before reaching a threshold,and then the temperature will keep in the threshold range.
文摘Measurement of nonlinearity parameter using the second-harmonic reflective model is studied. A new kind of compound transducer is designed and fabricated for this purpose. With this transducer and the finite amplitude insert-substitution method, an experimental system to measure the nonlinearity parameter using reflective model is developed. B/A values of some liquids and biological tissues are obtained and results coincide well with those presented in the literatures.
文摘The monitoring of cutting force in a vibration cutting process has a great significance in the popularization of ultrasonic vibration cutting technology. A new monitoring method of which the cutting force of ultrasonic elliptic vibration cutting is monitored using the electrical properties of transducer was proposed by studying on the relationship of cutting force, transducer electric impedance and load. A measurement system was designed for the electrical properties of transducer. The feasibility of cutting force monitoring method based on the electrical properties of piezoelectric transducer was proved by the cutting experiments.
基金Sponsored by the 873 Plan by Ministry of Science and Technology of China ( 2006AA12Z1137)CSSAR Innovation Project ( 2007)
文摘The compact ortho-mode transducer (OMT) and compact conical corrugated horn(CCCH) are used as feeding system of the deployable dual polarizing antenna in this paper.A new stricture of double-septum in main wave guide OMT is proposed. The finite difference method in time domain (FDTD) in combination with genetic algorithms(GAs) is used to analysis and optimize this new OMT. The experiment results show that the voltage standing wave ratio (VSWR) of this OMT and feeding system is less than 1.17 in bandwidth; the isolation between the ortho-mode ports is less than -40dB; the cross-polar level of the feed can reach -35dB and the length of the main waveguide can be reduced 50% at least.
基金Project(2014BAF12B01)supported by the Key Projects in the National Science&Technology Pillar Program during the Twelfth Five-year Plan Period,ChinaProject(51405520)supported by the National Natural Science Foundation of ChinaProject(2012CB619505)supported by National Basic Research Program of China
文摘Three differential equations based on different definitions of current density are compared. Formulation I is based on an incomplete equation for total current density (TCD). Formulations II and {I1 are based on incomplete and complete equations for source current density (SCD), respectively. Using the weak form of finite element method (FEM), three formulations were applied in a spiral coil electromagnetic acoustic transducer (EMAT) example to solve magnetic vector potential (MVP). The input impedances calculated by Formulation III are in excellent agreement with the experimental measurements. Results show that the errors for Formulations I & II vary with coil diameter, coil spacing, lift-off distance and external excitation frequency, for the existence of eddy-current and skin & proximity effects. And the current distribution across the coil conductor also follows the same trend. It is better to choose Formulation I instead of Formulation Ili to solve MVP when the coil diameter is less than twice the skin depth for Formulation I is a low cost and high efficiency calculation method.
文摘针对先进高性能飞行器对高精度大气数据的测控需求,研发设计了一套适用于亚声速飞行器的嵌入式大气数据传感(flush air data sensing,FADS)系统。该系统首先基于数值建模技术建立了FADS系统模型的压力数据库,并针对建模数据精度及风洞试验校准数据分析了Ma=0.2~0.4对应的压力误差限;其次,开发了攻角实时解算算法,并集成到工程原理样机中;最后基于风洞试验和飞行试验对FADS系统的实时解算算法及样机进行了系统评估,并通过事后模型算法对攻角进行重新解算以评估攻角实时解算算法的可靠性。结果表明:(1)与机载惯性导航系统等其他独立测试系统解算的数据相比,飞行试验中FADS系统采用的攻角实时解算方法精度整体较好,攻角误差小于1°,在关键段小于0.5°;基于不同模型建立的FADS系统攻角解算方法得到的攻角数值基本一致,证实了开发的实时解算算法的可靠性。(2)基于风洞试验及飞行试验数据对算法误差限的考核结果显示,飞行试验初始阶段实时解算的攻角值产生波动是压力输入波动误差限较大造成的,高空低速时的压力波动幅值大是实时解算攻角值偏差较大的主要原因;建立的FADS系统的攻角解算方法在算法误差限范围内的压力波动对攻角解算值影响较小,但超过算法误差限的压力波动对攻角解算值影响显著。高空低速飞行器FADS系统对测压传感器精度水平及工程实施水平要求较高,在实际工程应用中应尽量保证测压传感器的精度水平。