含分布式电源(distributed generation,DG)的双极直流配电系统是未来配电网发展的重要形态之一,但由于DG接入方式、数量、容量、位置以及系统正负极负荷不平衡对系统静暂态电压稳定性影响不同,目前相关研究尚缺乏对此问题的分析。该文...含分布式电源(distributed generation,DG)的双极直流配电系统是未来配电网发展的重要形态之一,但由于DG接入方式、数量、容量、位置以及系统正负极负荷不平衡对系统静暂态电压稳定性影响不同,目前相关研究尚缺乏对此问题的分析。该文首先将DG等效为受控电流源,推导分析了DG接入方式、容量及负荷不平衡度对系统静态下电压不平衡度的影响;其次,基于单极故障下光伏型DG与交流电网暂态放电情况,推导分析了DG接入方式、位置、容量与系统暂态电压稳定性的关系;再者,基于多目标蜣螂优化算法提出以系统静暂态电压稳定性与DG接入成本为目标的DG接入方案规划方法,采用熵权逼近理想解排序法(technique for order preference by similarity to ideal solution,TOPSIS)法筛选出DG接入的最佳折中方案。最后在Matlab/Simulink仿真平台搭建改进IEEE14、IEEE33双极直流配电系统验证该文所提优化方法的普适性和有效性。展开更多
The characteristics of induction generator based fixed-speed wind turbines(FSWT)are investigated.The impacts of different execution time in protective operations are studied under different fault duration and various ...The characteristics of induction generator based fixed-speed wind turbines(FSWT)are investigated.The impacts of different execution time in protective operations are studied under different fault duration and various wind velocity situations,e.g.,FSWT stabilities of load shedding in distribution systems.Based on this research,a dynamic protective control strategy for a distributed generation system(DGS)with FSWT is proposed.Finally,simulation results demonstrate the effectiveness of the strategy.展开更多
Owing to the wide range of applications in various fields,generative models have become increasingly popular.However,they do not handle spatio-temporal features well.Inspired by the recent advances in these models,thi...Owing to the wide range of applications in various fields,generative models have become increasingly popular.However,they do not handle spatio-temporal features well.Inspired by the recent advances in these models,this paper designs a distributed spatio-temporal generative adversarial network(STGAN-D)that,given some initial data and random noise,generates a consecutive sequence of spatio-temporal samples which have a logical relationship.This paper builds a spatio-temporal discriminator to distinguish whether the samples generated by the generator meet the requirements for time and space coherence,and builds a controller for distributed training of the network gradient updated to separate the model training and parameter updating,to improve the network training rate.The model is trained on the skeletal dataset and the traffic dataset.In contrast to traditional generative adversarial networks(GANs),the proposed STGAN-D can generate logically coherent samples with the corresponding spatial and temporal features while avoiding mode collapse.In addition,this paper shows that the proposed model can generate different styles of spatio-temporal samples given different random noise inputs,and the controller can improve the network training rate.This model will extend the potential range of applications of GANs to areas such as traffic information simulation and multiagent adversarial simulation.展开更多
The distributed generator over the last 30years has posed several challenges when they are connected to a distributed network.The most immediate problem is to change the voltage at the connection point depending on th...The distributed generator over the last 30years has posed several challenges when they are connected to a distributed network.The most immediate problem is to change the voltage at the connection point depending on the power supplied to the network and may cause it to exceed statutory limits.This paper describes a new control scheme for a distributed generator for supporting the voltage control in the network,thus ensuring the distributed generator to contribute to network voltage management.The scheme performance is demonstrated by a model for a distributed generator connected to a distribution network.The result shows that using the new control scheme,the distribution network voltage constraints are maintained while maximizing the active power delivered by distributed generators.展开更多
The estimation of generalized exponential distribution based on progressive censoring with binomial removals is presented, where the number of units removed at each failure time follows a binomial distribution. Maximu...The estimation of generalized exponential distribution based on progressive censoring with binomial removals is presented, where the number of units removed at each failure time follows a binomial distribution. Maximum likelihood estimators of the parameters and their confidence intervals are derived. The expected time required to complete the life test under this censoring scheme is investigated. Finally, the numerical examples are given to illustrate some theoretical results by means of Monte-Carlo simulation.展开更多
In distribution systems,network reconfiguration and capacitor placement are commonly used to diminish power losses and keep voltage profiles within acceptable limits.Moreover,the problem of DG allocation and sizing is...In distribution systems,network reconfiguration and capacitor placement are commonly used to diminish power losses and keep voltage profiles within acceptable limits.Moreover,the problem of DG allocation and sizing is great important.In this work,a combination of a fuzzy multi-objective approach and bacterial foraging optimization(BFO) as a meta-heuristic algorithm is used to solve the simultaneous reconfiguration and optimal sizing of DGs and shunt capacitors in a distribution system.Each objective is transferred into fuzzy domain using its membership function.Then,the overall fuzzy satisfaction function is formed and considered a fitness function inasmuch as the value of this function has to be maximized to gain the optimal solution.The numerical results show that the presented algorithm improves the performance much more than other meta-heuristic algorithms.Simulation results found that simultaneous reconfiguration with DG and shunt capacitors allocation(case 5) has 77.41%,42.15%,and 56.14%improvements in power loss reduction,load balancing,and voltage profile indices,respectively in 33-bus test system.This result found 87.27%,35.82%,and 54.34%improvements of mentioned indices respectively for 69-bus system.展开更多
To study the effects of wind generators on distribution system protection,the short-circuit current(SCC) characteristics of wind generators is important.Although there are many researches on the issue,a clear agreemen...To study the effects of wind generators on distribution system protection,the short-circuit current(SCC) characteristics of wind generators is important.Although there are many researches on the issue,a clear agreement has not been reached so far.The SCC characteristics for different wind generators are studied.PSCAD simulation is performed in the same system integrated with different kinds of wind generators,and their results are compared with those reported in IEEE papers.The detection possibility by overcurrent relay(OCR)is discussed based on the simulation results.展开更多
文摘含分布式电源(distributed generation,DG)的双极直流配电系统是未来配电网发展的重要形态之一,但由于DG接入方式、数量、容量、位置以及系统正负极负荷不平衡对系统静暂态电压稳定性影响不同,目前相关研究尚缺乏对此问题的分析。该文首先将DG等效为受控电流源,推导分析了DG接入方式、容量及负荷不平衡度对系统静态下电压不平衡度的影响;其次,基于单极故障下光伏型DG与交流电网暂态放电情况,推导分析了DG接入方式、位置、容量与系统暂态电压稳定性的关系;再者,基于多目标蜣螂优化算法提出以系统静暂态电压稳定性与DG接入成本为目标的DG接入方案规划方法,采用熵权逼近理想解排序法(technique for order preference by similarity to ideal solution,TOPSIS)法筛选出DG接入的最佳折中方案。最后在Matlab/Simulink仿真平台搭建改进IEEE14、IEEE33双极直流配电系统验证该文所提优化方法的普适性和有效性。
基金supported by the Danish Academy of Wind Energy(DAWE)
文摘The characteristics of induction generator based fixed-speed wind turbines(FSWT)are investigated.The impacts of different execution time in protective operations are studied under different fault duration and various wind velocity situations,e.g.,FSWT stabilities of load shedding in distribution systems.Based on this research,a dynamic protective control strategy for a distributed generation system(DGS)with FSWT is proposed.Finally,simulation results demonstrate the effectiveness of the strategy.
基金the National Natural Science Foundation of China(61573285).
文摘Owing to the wide range of applications in various fields,generative models have become increasingly popular.However,they do not handle spatio-temporal features well.Inspired by the recent advances in these models,this paper designs a distributed spatio-temporal generative adversarial network(STGAN-D)that,given some initial data and random noise,generates a consecutive sequence of spatio-temporal samples which have a logical relationship.This paper builds a spatio-temporal discriminator to distinguish whether the samples generated by the generator meet the requirements for time and space coherence,and builds a controller for distributed training of the network gradient updated to separate the model training and parameter updating,to improve the network training rate.The model is trained on the skeletal dataset and the traffic dataset.In contrast to traditional generative adversarial networks(GANs),the proposed STGAN-D can generate logically coherent samples with the corresponding spatial and temporal features while avoiding mode collapse.In addition,this paper shows that the proposed model can generate different styles of spatio-temporal samples given different random noise inputs,and the controller can improve the network training rate.This model will extend the potential range of applications of GANs to areas such as traffic information simulation and multiagent adversarial simulation.
基金supported by EPSRC SUPERGEN 1 Renewal Core-FlexNet:Renewal of the Supergen Consortium on Future Network Technologies.EPSRC GRANT Reference EP/E4011X/1
文摘The distributed generator over the last 30years has posed several challenges when they are connected to a distributed network.The most immediate problem is to change the voltage at the connection point depending on the power supplied to the network and may cause it to exceed statutory limits.This paper describes a new control scheme for a distributed generator for supporting the voltage control in the network,thus ensuring the distributed generator to contribute to network voltage management.The scheme performance is demonstrated by a model for a distributed generator connected to a distribution network.The result shows that using the new control scheme,the distribution network voltage constraints are maintained while maximizing the active power delivered by distributed generators.
基金supported by the National Natural Science Foundation of China(70471057)
文摘The estimation of generalized exponential distribution based on progressive censoring with binomial removals is presented, where the number of units removed at each failure time follows a binomial distribution. Maximum likelihood estimators of the parameters and their confidence intervals are derived. The expected time required to complete the life test under this censoring scheme is investigated. Finally, the numerical examples are given to illustrate some theoretical results by means of Monte-Carlo simulation.
文摘In distribution systems,network reconfiguration and capacitor placement are commonly used to diminish power losses and keep voltage profiles within acceptable limits.Moreover,the problem of DG allocation and sizing is great important.In this work,a combination of a fuzzy multi-objective approach and bacterial foraging optimization(BFO) as a meta-heuristic algorithm is used to solve the simultaneous reconfiguration and optimal sizing of DGs and shunt capacitors in a distribution system.Each objective is transferred into fuzzy domain using its membership function.Then,the overall fuzzy satisfaction function is formed and considered a fitness function inasmuch as the value of this function has to be maximized to gain the optimal solution.The numerical results show that the presented algorithm improves the performance much more than other meta-heuristic algorithms.Simulation results found that simultaneous reconfiguration with DG and shunt capacitors allocation(case 5) has 77.41%,42.15%,and 56.14%improvements in power loss reduction,load balancing,and voltage profile indices,respectively in 33-bus test system.This result found 87.27%,35.82%,and 54.34%improvements of mentioned indices respectively for 69-bus system.
基金supported by the Power Generation & Electricity Delivery of the Korea Institute of Energy Technology and Planning(KETEP)grant funded by the Korea Government Ministry of Knowledge Economy(No.2009T100200067)
文摘To study the effects of wind generators on distribution system protection,the short-circuit current(SCC) characteristics of wind generators is important.Although there are many researches on the issue,a clear agreement has not been reached so far.The SCC characteristics for different wind generators are studied.PSCAD simulation is performed in the same system integrated with different kinds of wind generators,and their results are compared with those reported in IEEE papers.The detection possibility by overcurrent relay(OCR)is discussed based on the simulation results.