期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Time Dependent DD Neutrons Measurement Using a Single Crystal Chemical Vapor Deposition Diamond Detector on EAST 被引量:1
1
作者 DU Tengfei PENG Xingyu +7 位作者 CHEN Zhongjing HU Zhimeng GE Lijian HU Liqun ZHONG Guoqiang PU Neng CHEN Jinxiang FAN Tieshuan 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第9期950-953,共4页
a single crystal chemical vapor deposition (scCVD) diamond detector has been successfully employed for neutron measurements in the EAST (Experimental Advanced Superconducting Tokamak) plasmas. The seCVD diamond de... a single crystal chemical vapor deposition (scCVD) diamond detector has been successfully employed for neutron measurements in the EAST (Experimental Advanced Superconducting Tokamak) plasmas. The seCVD diamond detector coated with a 5 μm 6LiF (95% 6Li enriched) layer was placed inside a polyethylene moderator to enhance the detection efficiency. The time-dependent neutron emission from deuteron plasmas during neutral beam injection (NBI) heating was obtained. The measured results are compared with that of fission chamber detectors, which always act as standard neutron flux monitors. The scCVD diamond detector exhibits good reliability, stability and the capability to withstand harsh radiation environments despite its low detection efficiency due to the small active volume. 展开更多
关键词 scCVD diamond detector neutron measurement EAST
在线阅读 下载PDF
Fabrication of a single-crystal diamond neutron detector and its application in 14.1 MeV neutron detection in deuterium-tritium fusion experiments 被引量:1
2
作者 许平 余羿 周海洋 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第7期14-18,共5页
A single-crystal diamond detector is fabricated to diagnose 14.1 MeV deuterium-tritium(D-T)fusion neutrons.The size of its diamond film is 4.5 mm×4.5 mm×500μm.This film is sandwiched by a flat,strip-pattern... A single-crystal diamond detector is fabricated to diagnose 14.1 MeV deuterium-tritium(D-T)fusion neutrons.The size of its diamond film is 4.5 mm×4.5 mm×500μm.This film is sandwiched by a flat,strip-patterned gold electrode.The dark current of this detector is experimentally measured to be lower than 0.1 nA under an electric field of 30 kV cm^(-1).This diamond detector is used to measure D-T fusion neutrons with a flux of about 7.5×10^(5) s^(-1)cm^(-2).The pronounced peak with a central energy of 8.28 MeV characterizing the^(12)C(n,α)~9Be reaction in the neutron energy spectrum is experimentally diagnosed,and the energy resolution is better than 1.69%,which is the best result reported so far using a diamond detector.A clear peak with a central energy of 6.52 MeV characterizing the^(12)C(n,n')3αreaction is also identified with an energy resolution of better than 7.67%. 展开更多
关键词 neutron diagnostic deuterium-tritium neutron single-crystal diamond neutron detector
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部