期刊文献+
共找到49篇文章
< 1 2 3 >
每页显示 20 50 100
Optimizing neon-based gas mixtures for two-stage amplification fast-timing Micromegas detectors
1
作者 Yue Meng Xu Wang +3 位作者 Jianbei Liu Ming Shao Zhiyong Zhang Yi Zhou 《中国科学技术大学学报》 北大核心 2025年第4期59-66,58,I0002,共10页
The PICOSEC Micromegas(MM)is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure.It features a two-stage amplification process th... The PICOSEC Micromegas(MM)is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure.It features a two-stage amplification process that leads to a significant deterioration of non-uniformity when scaling up to larger areas.Since the performance of gaseous detectors is highly dependent on the choice of working gas,optimizing the gas mixture offers a promising solution to improve the uniformity performance.This paper addresses these challenges through a combined approach of simulation based on Garfield++and experimental studies.The simulation investigates the properties of different mixing fractions of gas mixtures and their impact on detector performance,including gain uniformity and time resolution.To verify the simulation results,experimental tests were conducted using a multi-channel PICOSEC MM prototype with different gas mixtures.The experimental results are consistent with the findings of the simulation,indicating that a higher concentration of neon significantly improves the detector’s gain uniformity.Furthermore,the influence of gas mixtures on time resolution was explored as a critical performance indicator.The study presented in this paper offers valuable insights for improving uniformity in large-area PICOSEC MM detectors and optimizing overall performance. 展开更多
关键词 gaseous detectors MICROMEGAS timing detectors fast-timing Micromegas Monte Carlo simulation gain uniformity
在线阅读 下载PDF
Advances in integrated polarization detectors with innovative features
2
作者 BU Yong-Hao ZHOU Jing +8 位作者 DENG Jie WANG Ruo-Wen YE Tao SHI Meng-Die HUANG Jun-Wei ZHANG Yu-Jie NING Jun LU Wei CHEN Xiao-Shuang 《红外与毫米波学报》 北大核心 2025年第3期371-383,共13页
The polarization properties of light are widely applied in imaging,communications,materials analy⁃sis,and life sciences.Various methods have been developed that can measure the polarization information of a target.How... The polarization properties of light are widely applied in imaging,communications,materials analy⁃sis,and life sciences.Various methods have been developed that can measure the polarization information of a target.However,conventional polarization detection systems are often bulky and complex,limiting their poten⁃tial for broader applications.To address the challenges of miniaturization,integrated polarization detectors have been extensively explored in recent years,achieving significant advancements in performance and functionality.In this review,we focus mainly on integrated polarization detectors with innovative features,including infinitely high polarization discrimination,ultrahigh sensitivity to polarization state change,full Stokes parameters measure⁃ment,and simultaneous perception of polarization and other key properties of light.Lastly,we discuss the oppor⁃tunities and challenges for the future development of integrated polarization photodetectors. 展开更多
关键词 integrated polarization detector infinite polarization extinction ratio polarization state change detection full-Stokes multidimensional detection
在线阅读 下载PDF
Structural design of mid-infrared waveguide detectors based on InAs/GaAsSb superlattice
3
作者 PEI Jin-Di CHAI Xu-Liang +1 位作者 WANG Yu-Peng ZHOU Yi 《红外与毫米波学报》 SCIE EI CAS CSCD 北大核心 2024年第4期457-463,共7页
In the realm of near-infrared spectroscopy,the detection of molecules has been achieved using on-chip waveguides and resonators.In the mid-infrared band,the integration and sensitivity of chemical sensing chips are of... In the realm of near-infrared spectroscopy,the detection of molecules has been achieved using on-chip waveguides and resonators.In the mid-infrared band,the integration and sensitivity of chemical sensing chips are often constrained by the reliance on off-chip light sources and detectors.In this study,we demonstrate an InAs/GaAsSb superlattice mid-infrared waveguide integrated detector.The GaAsSb waveguide layer and the InAs/GaAsSb superlattice absorbing layer are connected through evanescent coupling,facilitating efficient and highquality detection of mid-infrared light with minimal loss.We conducted a simulation to analyze the photoelectric characteristics of the device.Additionally,we investigated the factors that affect the integration of the InAs/GaAs⁃Sb superlattice photodetector and the GaAsSb waveguide.Optimal thicknesses and lengths for the absorption lay⁃er are determined.When the absorption layer has a thickness of 0.3μm and a length of 50μm,the noise equiva⁃lent power reaches its minimum value,and the quantum efficiency can achieve a value of 68.9%.The utilization of waveguide detectors constructed with Ⅲ-Ⅴ materials offers a more convenient means of integrating mid-infra⁃red light sources and achieving photoelectric detection chips. 展开更多
关键词 InAs/GaAsSb superlattice waveguide detector evanescent coupling GaAsSb waveguide
在线阅读 下载PDF
Development of High-energy Particle Detectors for Space Exploration
4
作者 YANG Zhe SHEN Guohong JING Tao 《空间科学学报》 CAS CSCD 北大核心 2022年第6期1171-1184,共14页
Space environment exploration is a hot topic globally.The scope of space exploration ranges from near-Earth space to the moon,other planets in the solar system,and even the heliosphere and interplanetary space.It is u... Space environment exploration is a hot topic globally.The scope of space exploration ranges from near-Earth space to the moon,other planets in the solar system,and even the heliosphere and interplanetary space.It is used for various crucial applications,including aerospace technology development,space weather research,understanding the origin and evolution of the universe,searching for extraterrestrial life,and finding human livable places.Although China’s space environment exploration started late,its progress has been rapid.China is gradually narrowing the gap with advanced countries and may eventually lead the world in space research.This article briefly reviews the development history of China’s space environmental detectors. 展开更多
关键词 High-energy particle detectors Near-Earth space exploration Lunar exploration Space environment
在线阅读 下载PDF
High-resolution forward-looking imaging algorithm for missile-borne detectors 被引量:2
5
作者 CHENG Cheng GAO Min ZHOU Xiaodong 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2019年第3期456-466,共11页
Aiming at a novel missile-borne detector in the optional burst height proximity fuze, a self-adaptive high-resolution forward-looking imaging algorithm (SAHRFL-IA) is presented. The echo data are captured by the missi... Aiming at a novel missile-borne detector in the optional burst height proximity fuze, a self-adaptive high-resolution forward-looking imaging algorithm (SAHRFL-IA) is presented. The echo data are captured by the missile-borne detector in the target regions;thereby the azimuth angulation accuracy at the same distance dimension is improved dynamically. Thus, azimuth information of the targets in the detection area may be obtained accurately. The proposed imaging algorithm breaks through the conventional misconception of merely using azimuth discrimination curves under ideal conditions during monopulse angulation. The real-time echo data from the target region are used to perform error correction for this discrimination curve, and finally the accuracy of the azimuth angulation may reach the optimum at the same distance dimension. A series of experiments demonstrate the validity, reliability and high performance of the proposed imaging algorithm. Azimuth angulation accuracy may reach ten times that of the detection beam width. Meanwhile, the running time of this algorithm satisfies the requirements of missile-borne platforms. 展开更多
关键词 FORWARD-LOOKING imaging HIGH-RESOLUTION missileborne detector SELF-ADAPTIVE radio PROXIMITY FUZE
在线阅读 下载PDF
RAA-DETECTOR布鲁氏菌核酸快速检测方法的建立及应用
6
作者 张雲龙 王靖雷 +8 位作者 朱亚杰 张明洁 康澳 周翔 魏凯 曹洪防 李强 王勇 苏峰 《畜牧兽医学报》 北大核心 2025年第10期5115-5124,共10页
本研究旨在建立不依赖于专业设备的布鲁氏菌病高效快速检测体系,实现临床样本40 min内快速检测。首先比对不同布鲁氏菌的基因组,找到布鲁氏菌的核心共有序列,以布鲁氏菌S2菌株基因SEQ NO.6(CN 105018489A)为模板构建阳性质粒,用于后续试... 本研究旨在建立不依赖于专业设备的布鲁氏菌病高效快速检测体系,实现临床样本40 min内快速检测。首先比对不同布鲁氏菌的基因组,找到布鲁氏菌的核心共有序列,以布鲁氏菌S2菌株基因SEQ NO.6(CN 105018489A)为模板构建阳性质粒,用于后续试验;通过原核表达的方法分别表达CRISPR/AsCas12a和LwaCas13a蛋白;通过重组酶介导的等温核酸扩增技术(RAA)、体外表达技术结合AsCas12a/LwaCas13a的DETECTOR系统,优化高效检测体系、通过无限稀释法等进行检测。结果发现,设计的RAA引物能够有效扩增样本中的DNA片段,DETECTOR得到最佳反应的AsCas12a浓度为200 nmol·L^(-1),gRNA为200 nmol·L^(-1);Cas13a浓度为300 nmol·L^(-1),crRNA浓度为400 nmol·L^(-1);RAA-AsCas12a和RAA-LwaCas13a的检测体系的最佳反应时间为35 min,侧平流式纸条的最佳检测时间为20 min,细菌最低检测浓度为10 Copies·μL^(-1),且具有较好的检测特异性,临床样本的检测试验表明两种方法均有较好的重复性和检测精度,但LwaCas13a的精测精度更高,但二者无显著差异。该研究建立了2种RAA-CRISPR/Cas布鲁氏菌核酸快速检测体系,在临床上可获得较好的应用,RAA-LwaCas13a的检测方法精度更高。 展开更多
关键词 布鲁氏菌 RAA DETECTOR系统 SHERLOCK系统 AsCas12a LwaLwaCas13a
在线阅读 下载PDF
Unbiased test of the hyperon CP violation in terms of detector resolution at STCF
7
作者 Ming Xu Liang Liu +2 位作者 Yupeng Pei Xiaorong Zhou Yingchun Zhu 《中国科学技术大学学报》 北大核心 2025年第4期41-47,40,I0002,共9页
The study of the charge conjugation and parity(CP)violation of hyperon is the precision frontier for probing possible new CP violation sources beyond the standard model(SM).With the large number of quantum entangled h... The study of the charge conjugation and parity(CP)violation of hyperon is the precision frontier for probing possible new CP violation sources beyond the standard model(SM).With the large number of quantum entangled hyperonantihyperon pairs to be produced at Super Tau-Charm Facility(STCF),the CP asymmetry of hyperon is expected to be tested with a statistical sensitivity of 10^(−4) or even better.To cope with the statistical precision,the systematic effects from various aspects are critical and need to be studied in detail.In this paper,the sensitivity effects on the CP violation parameters associated with the detector resolution,including those of the position and momentum,are studied and discussed in detail.The results provide valuable guidance for the design of STCF detector. 展开更多
关键词 BESIII experiment STCF hyperon CP violation detector resolution unbiased test
在线阅读 下载PDF
Study of bonding layer for integrated structure of space gravitational wave detector telescope
8
作者 ZHAO Hong-chao LIU Chang +2 位作者 ZHOU Wen-ke ZHU Han-bin CHEN Wen-duo 《中国光学(中英文)》 北大核心 2025年第3期715-724,共10页
To detect space gravitational waves in the extremely low-frequency band,the telescope and optic-al platform require high stability and reliability.However,the cantilevered design presents challenges,espe-cially in the... To detect space gravitational waves in the extremely low-frequency band,the telescope and optic-al platform require high stability and reliability.However,the cantilevered design presents challenges,espe-cially in the glass-metal hetero-bonding process.This study focuses on the analysis and experimental re-search of the bonding layer in the integrated structure.By optimizing the structural configuration and select-ing suitable bonding processes,the reliability of the telescope system is enhanced.The research indicates that using J-133 adhesive achieves the best performance,with a bonding layer thickness of 0.30 mm and a metal substrate surface roughness of Ra 0.8.These findings significantly enhance the reliability of the optical sys-tem while minimizing potential risks. 展开更多
关键词 space gravitational-wave detector integrated structure glass-metal hetero-bonding
在线阅读 下载PDF
Flatness detection method of splicing detector based on channel spectral dispersion
9
作者 ZHAO Hong-chao ZHANG Xiao-qian AN Qi-chang 《中国光学(中英文)》 北大核心 2025年第4期889-898,共10页
For segmented detectors,surface flatness is critical as it directly influences both energy resolution and image clarity.Additionally,the limited adjustment range of the segmented detectors necessitates precise benchma... For segmented detectors,surface flatness is critical as it directly influences both energy resolution and image clarity.Additionally,the limited adjustment range of the segmented detectors necessitates precise benchmark construction.This paper proposes an architecture for detecting detector flatness based on channel spectral dispersion.By measuring the dispersion fringes for coplanar adjustment,the final adjustment residual is improved to better than 300 nm.This result validates the feasibility of the proposed technology and provides significant technical support for the development of next-generation large-aperture sky survey equipment. 展开更多
关键词 large aperture telescope segmented detector surface wavefront detection channel spectral dispersion
在线阅读 下载PDF
Robust adaptive radar beamforming based on iterative training sample selection using kurtosis of generalized inner product statistics 被引量:2
10
作者 TIAN Jing ZHANG Wei 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2024年第1期24-30,共7页
In engineering application,there is only one adaptive weights estimated by most of traditional early warning radars for adaptive interference suppression in a pulse reputation interval(PRI).Therefore,if the training s... In engineering application,there is only one adaptive weights estimated by most of traditional early warning radars for adaptive interference suppression in a pulse reputation interval(PRI).Therefore,if the training samples used to calculate the weight vector does not contain the jamming,then the jamming cannot be removed by adaptive spatial filtering.If the weight vector is constantly updated in the range dimension,the training data may contain target echo signals,resulting in signal cancellation effect.To cope with the situation that the training samples are contaminated by target signal,an iterative training sample selection method based on non-homogeneous detector(NHD)is proposed in this paper for updating the weight vector in entire range dimension.The principle is presented,and the validity is proven by simulation results. 展开更多
关键词 adaptive radar beamforming training sample selection non-homogeneous detector electronic jamming jamming suppression
在线阅读 下载PDF
Advantages of QWIP technology in infrared thermal cameras 被引量:1
11
作者 Eric Belhaire Regis Pichon 《应用光学》 CAS CSCD 北大核心 2017年第2期298-303,共6页
Standard GaAs/AlGaAs quantum well infrared photodetectors(QWIP)have been seriously considered as atechnological choice for the 3^(rd) generation of thermal imagers in the long wave infrared band(LWIR)for some time.Alt... Standard GaAs/AlGaAs quantum well infrared photodetectors(QWIP)have been seriously considered as atechnological choice for the 3^(rd) generation of thermal imagers in the long wave infrared band(LWIR)for some time.Alternative technology like MCT(HgCdTe)was the technology choice of the 2^(nd) generation because of its high quantum efficiency.In the paper,measurements on the QWIP technology will be presented and a comparison with alternative technology will be done. 展开更多
关键词 infrared detectors image sensors quantum well infrared photodetectors(QWIP)
在线阅读 下载PDF
基于特征匹配的亚像素级全景图像配准算法 被引量:5
12
作者 王丙勤 郭立 郑迈 《计算机工程与应用》 CSCD 北大核心 2008年第17期191-194,200,共5页
为了提高全景图全自动拼接中图像配准的速度和匹配稳健性,提出了一种基于相对距离法去除外点的亚像素级图像配准算法,并给出了分析和实验结果,亚像素级像素定位误差在0.01~0.1之内。在对12组图像匹配的实验结果表明,该匹配算法的匹配... 为了提高全景图全自动拼接中图像配准的速度和匹配稳健性,提出了一种基于相对距离法去除外点的亚像素级图像配准算法,并给出了分析和实验结果,亚像素级像素定位误差在0.01~0.1之内。在对12组图像匹配的实验结果表明,该匹配算法的匹配正确率达到100%,且匹配的时间小于目前通用的RANSAC匹配算法。 展开更多
关键词 HARRIS CORNER Detector 相互关系算法 特征匹配 全景图 亚像素
在线阅读 下载PDF
基于特征融合的SSD视觉小目标检测 被引量:12
13
作者 王冬丽 廖春江 +1 位作者 牟金震 周彦 《计算机工程与应用》 CSCD 北大核心 2020年第16期31-36,共6页
针对SSD算法在检测目标过程中对小目标检测效果差的缺陷,提出了特征融合的SSD方法。该方法充分融合深浅层特征信息以提升网络模型对小目标的检测能力,为更好地检测小目标,将先验框尺寸相对原图比列进行调整,同时对SSD模型相应超参数值... 针对SSD算法在检测目标过程中对小目标检测效果差的缺陷,提出了特征融合的SSD方法。该方法充分融合深浅层特征信息以提升网络模型对小目标的检测能力,为更好地检测小目标,将先验框尺寸相对原图比列进行调整,同时对SSD模型相应超参数值进行调整。实验结果表明,检测精度mAP较SSD提高3.4个百分点,对小目标Bottle、Chair、Plant检测精度分别提升8.7个百分点、3.4个百分点和7.1个百分点。检测精度mAP较当前一系列性能优异的目标检测算法有显著提高。通过拓展实验进一步证明改进算法成功检测到了大多数SSD算法没有检测到的小目标,提高了平均检测准确率。 展开更多
关键词 小目标检测 特征融合 SSD(Single Shot Multibox Detector) 特征增强 PASCAL VOC2007
在线阅读 下载PDF
基于V-detector算法的滚动轴承故障诊断方法 被引量:2
14
作者 杨先勇 周晓军 +2 位作者 林勇 张文斌 沈路 《浙江大学学报(工学版)》 EI CAS CSCD 北大核心 2010年第9期1805-1810,共6页
针对实值阴性选择(RNS)算法的检测器尺寸不能自适应变化的问题,提出基于变检测半径的RNS算法(V-detector)的轴承故障诊断方法.将计算轴承振动信号局域波分解后各基本模式分量的关联维数作为特征向量,并根据故障模式将其划分为多个自体... 针对实值阴性选择(RNS)算法的检测器尺寸不能自适应变化的问题,提出基于变检测半径的RNS算法(V-detector)的轴承故障诊断方法.将计算轴承振动信号局域波分解后各基本模式分量的关联维数作为特征向量,并根据故障模式将其划分为多个自体样本集,采用V-detector算法训练多个检测器集,用其对轴承故障进行诊断.结果表明:自体半径过小则误诊率高,自体半径过大则检测器灵敏度低,这都将导致准确率减小;覆盖率越高,则准确率越高、计算花费越大,当覆盖率≥95%时,覆盖率对准确率的影响远小于其对计算花费的影响;相对于基于RNS的诊断方法,V-detector算法具有同样高的准确率,且计算花费显著减小、稳定性更高,可有效地识别轴承故障. 展开更多
关键词 滚动轴承 故障诊断 V—detector算法 人工免疫系统 局域波分解
在线阅读 下载PDF
Detector729在放射治疗剂量学中的应用研究 被引量:1
15
作者 翟贺争 刘辉 +4 位作者 丁艳秋 李卫星 李明生 陈雪 王小春 《重庆医科大学学报》 CAS CSCD 北大核心 2014年第10期1474-1477,共4页
目的:探讨二维电离室矩阵探测器Detector729剂量测量的准确性及其在放射治疗质量控制中的应用。方法:采用0.6 cm3的参考电离室在X射线下对Detector729进行剂量刻度,然后两者进行剂量和输出因子测量比对,最后应用Detector729对调强放射治... 目的:探讨二维电离室矩阵探测器Detector729剂量测量的准确性及其在放射治疗质量控制中的应用。方法:采用0.6 cm3的参考电离室在X射线下对Detector729进行剂量刻度,然后两者进行剂量和输出因子测量比对,最后应用Detector729对调强放射治疗(intensity modulated radiation therapy,IMRT)治疗计划进行实际机架角剂量验证。结果:参考电离室对Detector729电离室的刻度因子是0.991,两者测量结果比对相对测量偏差≤0.57%,在4 cm×4 cm^20 cm×20 cm不同方形野下输出因子测量结果基本一致,应用Detector729对IMRT剂量验证的γ通过率均>90%。结论:应用Detector729进行放疗剂量测量和质量控制工作,结果具有较高的准确度和可信度,可为规范我国放疗剂量测量工具的使用提供理论依据。 展开更多
关键词 Detector729 剂量验证 剂量比对 输出因子
在线阅读 下载PDF
知识辅助的机载MIMO雷达STAP非均匀样本检测方法 被引量:3
16
作者 王珽 赵拥军 《系统工程与电子技术》 EI CSCD 北大核心 2015年第10期2260-2265,共6页
针对样本协方差矩阵受干扰目标污染时机载多输入多输出(multiple-input multiple-output,MIMO)雷达空时自适应处理(space-time adaptive processing,STAP)目标检测性能下降的不足,提出一种知识辅助(knowledge-aided,KA)的广义内积非均... 针对样本协方差矩阵受干扰目标污染时机载多输入多输出(multiple-input multiple-output,MIMO)雷达空时自适应处理(space-time adaptive processing,STAP)目标检测性能下降的不足,提出一种知识辅助(knowledge-aided,KA)的广义内积非均匀样本检测方法。首先利用扁长椭球波函数估计的杂波子空间知识,离线构造杂波协方差矩阵,然后与广义内积非均匀检测器(generalized inner product non-homogeneity detector,GIP NHD)结合,实现对训练样本的有效选择,使目标检测不受训练样本中干扰目标的影响。仿真结果表明,相对于常规GIP方法,KA-GIP方法能够对存在干扰目标的样本进行更加有效地剔除,并且机载MIMO雷达STAP的目标检测性能得到显著提升,因此更有利于实际工程应用。 展开更多
关键词 机载多输入多输出雷达 空时自适应处理 知识辅助 广义内积非均匀检测器 干扰目标 SPACE-TIME adaptive processing (STAP) knowledge-aid (KA) generalized inner product non-homogeneity detector (GIP NHD)
在线阅读 下载PDF
Structural adaptive and optimal speckle filtering in multilook full polarimetric SAR images
17
作者 Sun Nan Zhang Bingchen Wang Yanfei 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2007年第2期217-222,共6页
A novel approach is proposed for speckle reduction in multilook full polarimetric SAR images. In contrast to others, this approach adopts an enhanced structure detection method to estimate the parameters of the polari... A novel approach is proposed for speckle reduction in multilook full polarimetric SAR images. In contrast to others, this approach adopts an enhanced structure detection method to estimate the parameters of the polarimetric covariance matrix for the multilook polarimetric whitening filtering (MPWF) algorithm and thus a structural adaptive and optimal speckle filter is developed. To evaluate the present approach, NASA SIR-C/X- SAR, L band, four-look processed polarimetric SAR data of the Tian-Mountain Forest is used for simulation. Experimental results demonstrate the effectiveness of this novel filtering algorithm in case of both speckle reduction and preservation of texture information. Comparisons with other methods are also made. 展开更多
关键词 MPWF Geometrical-ratio detectors ESDMPWF SPECKLE Multilook polarimetric SAR.
在线阅读 下载PDF
A high performance waveform and a new ranging method for the proximity detector
18
作者 Qi-le Chen Xin-hong Hao +1 位作者 Xiao-peng Yan Ping Li 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2020年第4期834-845,共12页
Signal modulation is an essential design factor for proximity detectors and directly affects the system's potential performance.In order to achieve the advantages of chaotic codes bi-phase modulation(CCBPM)and lin... Signal modulation is an essential design factor for proximity detectors and directly affects the system's potential performance.In order to achieve the advantages of chaotic codes bi-phase modulation(CCBPM)and linear frequency modulation(LFM) simultaneously,this paper designed a waveform which combined chaotic codes bi-phase modulation and linear frequency modulation(CCBPM-LFM) for proximity detectors.The CCBPM-LFM waveform was analyzed in the aspect of time delay resolution(TDR) and Doppler tolerance(DT) based on ambiguity function(AF).Then,a ranging method,which we called instant correlation harmonic demodulation(ICHD),was presented for the detector using the CCBPM-LFM waveform.By combining time domain instant correlation with harmonic demodulation,the ICHD solved the problem caused by combination modulation and made the most of the linear frequency modulation(LFM) harmonics and the correlation of chaotic codes.Finally,a prototype was implemented and ranging experiments were carried out.From the theoretical analysis and experimental results,the proximity detector used the CCBPM-LFM waveform has an outstanding detection performance. 展开更多
关键词 Proximity detectors Detection performance Combination modulation Chaotic codes bi-phase modulation Linear frequency modulation
在线阅读 下载PDF
On the Small SNR Processing Ability of IR Point Target Detection
19
作者 Song, Liuping Sun, Zhongkang 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 1993年第3期28-36,共9页
Three-dimensional (3-D) matched filtering has been suggested as a powerful processing technique for detecting weak, moving IR point target immersed in a noisy field. Based on the theory of the 3-D matched filtering an... Three-dimensional (3-D) matched filtering has been suggested as a powerful processing technique for detecting weak, moving IR point target immersed in a noisy field. Based on the theory of the 3-D matched filtering and the optimal linear processing, the optimal point target detector is being analyzed in this paper. The performance of the detector is introduced in detail. The results provide a standard reference to evaluate the performance of any other point target detection algorithms. 展开更多
关键词 ALGORITHMS Correlation detectors Digital signal processing Image processing Signal detection Signal to noise ratio Systems analysis Three dimensional
在线阅读 下载PDF
加速器质谱法测量99Tc 被引量:1
20
作者 彭博 何明 +6 位作者 丁艳秋 管永精 武绍勇 董克君 李世红 阮向东 姜山 《质谱学报》 EI CAS CSCD 2005年第z1期69-70,共2页
99Tc is a fission product, and it has high fission yield (6%) and very long half-life (2.1×105 a). With the movement of nucleus, the concentration of 99Tc is increasing in the circumstance. So it's important ... 99Tc is a fission product, and it has high fission yield (6%) and very long half-life (2.1×105 a). With the movement of nucleus, the concentration of 99Tc is increasing in the circumstance. So it's important to measure the concentration of 99Tc in the circumstance, and accelerator mass spectrometry (AMS) might be the best method for 99Tc measurement. The 93Nb is used for AMS instrument normalization, sample matrix. And we used the difference of energy loss and deducting the isotope to measure the 99Tc in a series of standard samples. And the results show that the AMS is the feasible measurement method. 展开更多
关键词 99Tc ACCELERATOR mass SPECTROMETRY deduct the ISOTOPE gas IONISATION DETECTOR
在线阅读 下载PDF
上一页 1 2 3 下一页 到第