Polychromatic reconstruction(PCR) is a novel nondestructive readout method that utilizes a spectrally broad light source for the probe beam. The stored image can be completely reconstructed even though the probe wavel...Polychromatic reconstruction(PCR) is a novel nondestructive readout method that utilizes a spectrally broad light source for the probe beam. The stored image can be completely reconstructed even though the probe wavelength is very different from the recording one. The large spectral width of the polychromatic probe beam also causes adverse effect on the storage density. But this can be overcomed if an additional optical component is inserted in the imaging system. Therefore, PCR has a great potential to achieve nondestructive readout and large storage density simultaneously. In addition, PCR enables us to design a simple memory system because its readout tolerance is quite large as compared to the conventional monochromatic readout. Unique and attractive features of the polychromatic reconstruction method was theoretically and experimentally demonstrated.展开更多
Readout electronics is developed for a prototype spectrometer for in situ measurement of low-energy ions of30 e V/e–20 ke V/e in the solar wind plasma.A low-noise preamplifier/discriminator(A111F) is employed for eac...Readout electronics is developed for a prototype spectrometer for in situ measurement of low-energy ions of30 e V/e–20 ke V/e in the solar wind plasma.A low-noise preamplifier/discriminator(A111F) is employed for each channel to process the signal from micro-channel plate(MCP) detectors.A high-voltage(HV) supply solution based on a HV module and a HV optocoupler is adopted to generate a fast sweeping HV and a fixed HV.Due to limitation of telemetry bandwidth in space communication,an algorithm is implemented in an FPGA(field programmable gate array) to compress the raw data.Test results show that the electronics achieves a 1 MHz event rate and a large input dynamic range of 95 p C.A slew rate of 0.8 V/ls and an integral nonlinearity of 0.7-LSB for the sweeping HV,and a precision of less than 0.8 % for the fixed HV are obtained.A vacuum beam test shows an energy resolution of 12 ± 0.7 % full width at half maximum(FWHM) is achieved,and noise counts are less than10/sec,indicating that the performance meets the physical requirement.展开更多
Four different states of Si15Sb85 and Ge2Sb2Te5 phase change memory thin films are obtained by crystallization degree modulation through laser initialization at different powers or annealing at different temperatures....Four different states of Si15Sb85 and Ge2Sb2Te5 phase change memory thin films are obtained by crystallization degree modulation through laser initialization at different powers or annealing at different temperatures. The polarization characteristics of these two four-level phase change recording media are analyzed systematically. A simple and effective readout scheme is then proposed, and the readout signal is numerically simulated. The results show that a high-contrast polarization readout can be obtained in an extensive wavelength range for the four-level phase change recording media using common phase change materials. This study will help in-depth understanding of the physical mechanisms and provide technical approaches to multilevel phase change recording.展开更多
本文针对大规模高帧频读出电路的数字信号输出建立了高速数据传输模型。首先由集总参数模型得到传输电路3 d B带宽及响应时间常数与各器件参数之间的关系,指明了输出级MOS管的尺寸及传输线负载是决定高速时域响应特性的关键参数。进一...本文针对大规模高帧频读出电路的数字信号输出建立了高速数据传输模型。首先由集总参数模型得到传输电路3 d B带宽及响应时间常数与各器件参数之间的关系,指明了输出级MOS管的尺寸及传输线负载是决定高速时域响应特性的关键参数。进一步采用分布参数模型,利用Elmore延时模型更精确地确定了响应时间常数的数学解析式,获得了可使带宽最大化的输出级尺寸的最优设计。仿真结果表明,在典型的64×64面阵功耗和面积约束条件下,优化后传输门和复合逻辑门两种三态传输电路的输出3 dB带宽分别可达293 MHz和395 MHz。展开更多
文摘Polychromatic reconstruction(PCR) is a novel nondestructive readout method that utilizes a spectrally broad light source for the probe beam. The stored image can be completely reconstructed even though the probe wavelength is very different from the recording one. The large spectral width of the polychromatic probe beam also causes adverse effect on the storage density. But this can be overcomed if an additional optical component is inserted in the imaging system. Therefore, PCR has a great potential to achieve nondestructive readout and large storage density simultaneously. In addition, PCR enables us to design a simple memory system because its readout tolerance is quite large as compared to the conventional monochromatic readout. Unique and attractive features of the polychromatic reconstruction method was theoretically and experimentally demonstrated.
基金supported by the National Key Scientific Instrument and Equipment Development Projects of the National Natural Science Foundation of China(No.41327802)the Fundamental Research Funds for the Central Universities(WK2030040066)
文摘Readout electronics is developed for a prototype spectrometer for in situ measurement of low-energy ions of30 e V/e–20 ke V/e in the solar wind plasma.A low-noise preamplifier/discriminator(A111F) is employed for each channel to process the signal from micro-channel plate(MCP) detectors.A high-voltage(HV) supply solution based on a HV module and a HV optocoupler is adopted to generate a fast sweeping HV and a fixed HV.Due to limitation of telemetry bandwidth in space communication,an algorithm is implemented in an FPGA(field programmable gate array) to compress the raw data.Test results show that the electronics achieves a 1 MHz event rate and a large input dynamic range of 95 p C.A slew rate of 0.8 V/ls and an integral nonlinearity of 0.7-LSB for the sweeping HV,and a precision of less than 0.8 % for the fixed HV are obtained.A vacuum beam test shows an energy resolution of 12 ± 0.7 % full width at half maximum(FWHM) is achieved,and noise counts are less than10/sec,indicating that the performance meets the physical requirement.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.61178059 and 61137002)the Key Program of the Science and Technology Commission of Shanghai Municipality,China(Grant No.11jc1413300)
文摘Four different states of Si15Sb85 and Ge2Sb2Te5 phase change memory thin films are obtained by crystallization degree modulation through laser initialization at different powers or annealing at different temperatures. The polarization characteristics of these two four-level phase change recording media are analyzed systematically. A simple and effective readout scheme is then proposed, and the readout signal is numerically simulated. The results show that a high-contrast polarization readout can be obtained in an extensive wavelength range for the four-level phase change recording media using common phase change materials. This study will help in-depth understanding of the physical mechanisms and provide technical approaches to multilevel phase change recording.