With the rapid development of the nuclear power industry on a global scale,the discharge of radioactive e uents from nuclear power plants and their impact on the environment have become important issues in radioactive...With the rapid development of the nuclear power industry on a global scale,the discharge of radioactive e uents from nuclear power plants and their impact on the environment have become important issues in radioactive waste management,radiation protection,and environmental impact assessments.-detection of nuclides requires tedious processes,such as waiting for the radioactive balance of the sample and pretreatment separation,and there is an urgent need for a method specifically designed for mixing rapid energy spectrum measurement method for nuclide samples.The analysis of hybrid-energy spectrum is proposed in this study as a new algorithm,which takes advantage of the spectral analysis of-logarithmic energy spectrum and fitting ability of Fourier series.The logarithmic energy spectrum is obtained by logarithmic conversion of the hybrid linear energy spectrum.The Fourier fitting interpolation method is used to fit the logarithmic energy spectrum numerically.Next,the interpolation points for the‘e ective high-energy window’and‘e ective low-energy window’corresponding to the highest E_(m)nuclide in the hybrid logarithmic fitted energy spectrum are set,and spline interpolation is performed three times to obtain the logarithmic fitted energy spectrum of the highest E_(m)nuclide.Finally,the logarithmic fitted spectrum of the highest E_(m)nuclide is subtracted from the hybrid logarithmic fitted spectrum to obtain a logarithmic fitted spectrum comprised of the remaining lower E_(m)nuclides.The aforementioned process is iterated in a loop to resolve the logarithmic spectra of each nuclide in the original hybrid logarithmic spectra.Then,the radioactivity of E_(m)nuclides to be measured is calculated.In the experimental tests,^(14)C,^(90)Sr,and ^(90)Y spectra,which are obtained using the Fourier fitting interpolation method are compared with the original simulated ^(14)C,^(90)Sr,and ^(90)Y spectra of GEANT4.The measured liquid scintillator data of ^(90)Sr∕^(90)Y sample source and simulated data from GEANT4 are then analyzed.Analysis of the experimental results indicates that the Fourier fitting interpolation method accurately solves ^(14)C,^(90)Sr,and ^(90)Y energy spectra,which is in good agreement with the original GEANT4 simulation.The error in ^(90)Y activity,calculated using the actual detection e ciency,is less than 10%and less than 5%when using the simulated full-spectrum detection e ciency,satisfying the experimental expectations.展开更多
文摘在电力设计中,电气设备和载流导体的选择必须进行短路电流的计算.针对通常计算短路电流是以手工形式进行的问题,提出了短路电流的计算机算法.该算法根据电力网络特点及同步电机过渡过程理论,采用导纳矩阵法,推导出求解转移阻抗的数学模型,经换算进一步得到电源的运算阻抗,再用插值法查取存入计算机中的相应的运算曲线,以代替人工查'运算曲线数字表',从而自动实现短路电流的求解,算法简单可行.根据该算法编写的程序,可计算具有1 000个节点、2 000条支路、300台发电机和150个故障点的网络的三相短路电流计算.程序中插值法计算结果的小数点后3~4位有效数字与'运算曲线数字表'一致.对于具有20个节点的小型电力网络系统来说手工计算需要2 d,而通过计算机计算只需10 min.
基金supported by the National Natural Science Foundation of China(No.12005026)。
文摘With the rapid development of the nuclear power industry on a global scale,the discharge of radioactive e uents from nuclear power plants and their impact on the environment have become important issues in radioactive waste management,radiation protection,and environmental impact assessments.-detection of nuclides requires tedious processes,such as waiting for the radioactive balance of the sample and pretreatment separation,and there is an urgent need for a method specifically designed for mixing rapid energy spectrum measurement method for nuclide samples.The analysis of hybrid-energy spectrum is proposed in this study as a new algorithm,which takes advantage of the spectral analysis of-logarithmic energy spectrum and fitting ability of Fourier series.The logarithmic energy spectrum is obtained by logarithmic conversion of the hybrid linear energy spectrum.The Fourier fitting interpolation method is used to fit the logarithmic energy spectrum numerically.Next,the interpolation points for the‘e ective high-energy window’and‘e ective low-energy window’corresponding to the highest E_(m)nuclide in the hybrid logarithmic fitted energy spectrum are set,and spline interpolation is performed three times to obtain the logarithmic fitted energy spectrum of the highest E_(m)nuclide.Finally,the logarithmic fitted spectrum of the highest E_(m)nuclide is subtracted from the hybrid logarithmic fitted spectrum to obtain a logarithmic fitted spectrum comprised of the remaining lower E_(m)nuclides.The aforementioned process is iterated in a loop to resolve the logarithmic spectra of each nuclide in the original hybrid logarithmic spectra.Then,the radioactivity of E_(m)nuclides to be measured is calculated.In the experimental tests,^(14)C,^(90)Sr,and ^(90)Y spectra,which are obtained using the Fourier fitting interpolation method are compared with the original simulated ^(14)C,^(90)Sr,and ^(90)Y spectra of GEANT4.The measured liquid scintillator data of ^(90)Sr∕^(90)Y sample source and simulated data from GEANT4 are then analyzed.Analysis of the experimental results indicates that the Fourier fitting interpolation method accurately solves ^(14)C,^(90)Sr,and ^(90)Y energy spectra,which is in good agreement with the original GEANT4 simulation.The error in ^(90)Y activity,calculated using the actual detection e ciency,is less than 10%and less than 5%when using the simulated full-spectrum detection e ciency,satisfying the experimental expectations.