Objective To explore the contrast-enhanced ultrasonographic features for quantitative assessment of hepatic fibrosis. Methods 86 patients with chronic viral hepatitis B were enrolled in this study from March 2007 to A...Objective To explore the contrast-enhanced ultrasonographic features for quantitative assessment of hepatic fibrosis. Methods 86 patients with chronic viral hepatitis B were enrolled in this study from March 2007 to August 2009. The patients were classified into 5 groups (S0-S4) according to fibrosis stage evaluated with ultrasound guided liver biopsy. New contrast-enhanced ultrasonography (CEUS) features including area under the time-intensity curve (TIC) of portal venous phase/hepatic arterial phase (Qp/Qa) and intensity of portal venous phase/hepatic arterial phase (Ip/Ia) were used to detect the blood supply ratio (portal vein/hepatic artery) in each group. Arrival time of portal vein trunk (Tp) and decreasing rate of TIC (β ) were also analyzed. Results Qp/Qa and Ip/Ia decreased from S0 to S4, while Tp and β increased. These 4 features were significantly correlated with the degree of fibrosis (P<0.001) and were significantly different among the five groups (P<0.001). Sensitivity and specificity of Ip/Ia were 80% and 86% for groups ≥S1, 75% and 86% for groups ≥ S2, 71% and 84% for groups ≥ S3, and 76% and 80% for group S4, respectively. Sensitivity and specificity of Qp/Qa were 70% and 88% for groups ≥ S1, 80% and 76% for groups ≥ S2, 74% and 70% for groups ≥ S3, and 81% and 95% for group S4, respectively. Conclusion Ip/Ia and Qp/Qa could be adopted as reliable, non-invasive features for quantitative assessment of hepatic fibrosis.展开更多
Objective:To introduce a new better contrast-enhanced MR angiographic metnod, named 3D time-resolved imaging of contrast kinetics (3D-TRICKS). Methods: TRICKS is a high temporal resolution (2-6 s) MR angiographi...Objective:To introduce a new better contrast-enhanced MR angiographic metnod, named 3D time-resolved imaging of contrast kinetics (3D-TRICKS). Methods: TRICKS is a high temporal resolution (2-6 s) MR angiographic technique using a short TR(4 ms) and TE(1.5 ms), partial echo sampling, in which central part of k-space is updated more frequently than the peripheral part. TRICKS pre-contrast mask 3D images are firstly scanned, and then the bolus injecting of Gd-DTPA, 15-20 sequential 3D images are acquired. The reconstructed 3D images, subtraction of contrast 3D images with mask images, are conceptually similar to a catheter-based intra-arterial digital subtraction angiographic series (DSA). Thirty patients underwent contrast-enhanced MR angiography using 3D-TRICKS. Results: Totally 12 vertebral arteries were well displayed on TRICKS, in which 7 were normal, 1 demonstrated bilateral vertebral artery stenosis, 4 had unilateral vertebral artery stenosis and 1 was accompanied with the same lateral carotid artery bifurcation stenosis. Four cases of bilateral renal arteries were normal, 1 transplanted kidney artery showed as normal and 1 transplanted kidney artery showed stenosis. 2 cerebral arteries were normal, 1 had sagittal sinus thrombosis and 1 displayed intracranial arteriovenous malformation. 3 pulmonary arteries were normal, 1 showed pulmonary artery thrombosis and 1 revealed pulmonary sequestration's abnormal feeding artery and draining vein. One left lower limb fibrolipoma showed feeding artery. One displayed radial-ulnar artery artificial fistula stenosis. One revealed left antebrachium hemangioma. Conclusion: TRICKS can clearly delineate most body vascular system and reveal most vascular abnormality. It possesses convenience and high successful rate, which make it the first choice of displaying most vascular abnormality.展开更多
Objective To investigate diagnostic efficacy of transvaginal three-dimensional hysterosalpingo-contrast sonography(3D-Hy Co Sy) in assessing tubal patency with chromolaporoscopy. Methods A total of 157 infertile women...Objective To investigate diagnostic efficacy of transvaginal three-dimensional hysterosalpingo-contrast sonography(3D-Hy Co Sy) in assessing tubal patency with chromolaporoscopy. Methods A total of 157 infertile women underwent 3D-Hy Co Sy to evaluate tubal patency. Among these patients, 39 patients were also examined by chromolaporoscopy. The concordance of the two clinical assessment methods was analyzed by the Kappa coefficient test. Results Among the 306 oviducts examined by 3D-Hy Co Sy, 99(32.4%) were patent, 126(41.2%) partially obstructed, and 81(26.5%) completely obstructed. Diagnostic results with 3D-Hy Co Sy were not statistically different from those obtained in the 39 women(78 oviducts) who also underwent chromolaporoscopy, and the two methods showed a high concordance(κ=0.747, P=0.000). The 3D-Hy Co Sy procedure had a sensitivity of 84.8%(28/33), a specificity of 96.2%(25/26), and positive and negative predictive values of 93.3%(28/30) and 86.2%(25/29) respectively. Conclusion Transvaginal 3D-Hy Co Sy can accurately reveal the spatial path and morphology of the oviduct and is a safe and effective method to evaluate tubal patency.展开更多
In this paper we report on a high-contrast top-emitting organic light-emitting device utilizing a moderate-reflection contrast-enhancement stack and a high refractive index anti-reflection layer.The contrast-enhanceme...In this paper we report on a high-contrast top-emitting organic light-emitting device utilizing a moderate-reflection contrast-enhancement stack and a high refractive index anti-reflection layer.The contrast-enhancement stack consists of a thin metal anode layer,a dielectric bilayer,and a thick metal underlayer.The resulting device,with the optimized contrast-enhancement stack thicknesses of Ni(30 nm)/MgF 2(62 nm)/ZnS(16 nm)/Ni(20 nm) and the 25-nm-thick ZnS anti-reflection layer,achieves a luminous reflectance of 4.01% in the visible region and a maximum current efficiency of 0.99 cd/A(at 62.3 mA/cm 2) together with a very stable chromaticity.The contrast ratio reaches 561:1 at an on-state brightness of 1000 cd/m^2 under an ambient illumination of 140 lx.In addition,the anti-reflection layer can also enhance the transmissivity of the cathode and improve light out-coupling by the effective restraint of microcavity effects.展开更多
基金Supported by PhD Programs Foundation of Ministry of Education of China (No. 20090001110092)
文摘Objective To explore the contrast-enhanced ultrasonographic features for quantitative assessment of hepatic fibrosis. Methods 86 patients with chronic viral hepatitis B were enrolled in this study from March 2007 to August 2009. The patients were classified into 5 groups (S0-S4) according to fibrosis stage evaluated with ultrasound guided liver biopsy. New contrast-enhanced ultrasonography (CEUS) features including area under the time-intensity curve (TIC) of portal venous phase/hepatic arterial phase (Qp/Qa) and intensity of portal venous phase/hepatic arterial phase (Ip/Ia) were used to detect the blood supply ratio (portal vein/hepatic artery) in each group. Arrival time of portal vein trunk (Tp) and decreasing rate of TIC (β ) were also analyzed. Results Qp/Qa and Ip/Ia decreased from S0 to S4, while Tp and β increased. These 4 features were significantly correlated with the degree of fibrosis (P<0.001) and were significantly different among the five groups (P<0.001). Sensitivity and specificity of Ip/Ia were 80% and 86% for groups ≥S1, 75% and 86% for groups ≥ S2, 71% and 84% for groups ≥ S3, and 76% and 80% for group S4, respectively. Sensitivity and specificity of Qp/Qa were 70% and 88% for groups ≥ S1, 80% and 76% for groups ≥ S2, 74% and 70% for groups ≥ S3, and 81% and 95% for group S4, respectively. Conclusion Ip/Ia and Qp/Qa could be adopted as reliable, non-invasive features for quantitative assessment of hepatic fibrosis.
文摘Objective:To introduce a new better contrast-enhanced MR angiographic metnod, named 3D time-resolved imaging of contrast kinetics (3D-TRICKS). Methods: TRICKS is a high temporal resolution (2-6 s) MR angiographic technique using a short TR(4 ms) and TE(1.5 ms), partial echo sampling, in which central part of k-space is updated more frequently than the peripheral part. TRICKS pre-contrast mask 3D images are firstly scanned, and then the bolus injecting of Gd-DTPA, 15-20 sequential 3D images are acquired. The reconstructed 3D images, subtraction of contrast 3D images with mask images, are conceptually similar to a catheter-based intra-arterial digital subtraction angiographic series (DSA). Thirty patients underwent contrast-enhanced MR angiography using 3D-TRICKS. Results: Totally 12 vertebral arteries were well displayed on TRICKS, in which 7 were normal, 1 demonstrated bilateral vertebral artery stenosis, 4 had unilateral vertebral artery stenosis and 1 was accompanied with the same lateral carotid artery bifurcation stenosis. Four cases of bilateral renal arteries were normal, 1 transplanted kidney artery showed as normal and 1 transplanted kidney artery showed stenosis. 2 cerebral arteries were normal, 1 had sagittal sinus thrombosis and 1 displayed intracranial arteriovenous malformation. 3 pulmonary arteries were normal, 1 showed pulmonary artery thrombosis and 1 revealed pulmonary sequestration's abnormal feeding artery and draining vein. One left lower limb fibrolipoma showed feeding artery. One displayed radial-ulnar artery artificial fistula stenosis. One revealed left antebrachium hemangioma. Conclusion: TRICKS can clearly delineate most body vascular system and reveal most vascular abnormality. It possesses convenience and high successful rate, which make it the first choice of displaying most vascular abnormality.
基金Supported by the Health Department of Guangdong Province(B2011259)
文摘Objective To investigate diagnostic efficacy of transvaginal three-dimensional hysterosalpingo-contrast sonography(3D-Hy Co Sy) in assessing tubal patency with chromolaporoscopy. Methods A total of 157 infertile women underwent 3D-Hy Co Sy to evaluate tubal patency. Among these patients, 39 patients were also examined by chromolaporoscopy. The concordance of the two clinical assessment methods was analyzed by the Kappa coefficient test. Results Among the 306 oviducts examined by 3D-Hy Co Sy, 99(32.4%) were patent, 126(41.2%) partially obstructed, and 81(26.5%) completely obstructed. Diagnostic results with 3D-Hy Co Sy were not statistically different from those obtained in the 39 women(78 oviducts) who also underwent chromolaporoscopy, and the two methods showed a high concordance(κ=0.747, P=0.000). The 3D-Hy Co Sy procedure had a sensitivity of 84.8%(28/33), a specificity of 96.2%(25/26), and positive and negative predictive values of 93.3%(28/30) and 86.2%(25/29) respectively. Conclusion Transvaginal 3D-Hy Co Sy can accurately reveal the spatial path and morphology of the oviduct and is a safe and effective method to evaluate tubal patency.
基金Project supported by the State Key Development Program for Basic Research of China (Grant No. 2009CB930600)the National Natural Science Foundation of China (Grant Nos. 60907047,61274065,60977024,21101095,20974046,21003076,51173081,and 61136003)+3 种基金the Specialized Research Foundation for the Doctoral Program of Higher Education,China (Grant No. 20093223120003)the Natural Science Foundation of Institutions of Higher Education of Jiangsu Province,China (Grant Nos. SJ209003,09KJB150009,10KJB510013,and TJ209035)the "Qing Lan" Program of Jiangsu Province,Chinathe Program of Nanjing University of Posts and Telecommunications,China (Grant Nos. NY210015,NY211069,and NY210040)
文摘In this paper we report on a high-contrast top-emitting organic light-emitting device utilizing a moderate-reflection contrast-enhancement stack and a high refractive index anti-reflection layer.The contrast-enhancement stack consists of a thin metal anode layer,a dielectric bilayer,and a thick metal underlayer.The resulting device,with the optimized contrast-enhancement stack thicknesses of Ni(30 nm)/MgF 2(62 nm)/ZnS(16 nm)/Ni(20 nm) and the 25-nm-thick ZnS anti-reflection layer,achieves a luminous reflectance of 4.01% in the visible region and a maximum current efficiency of 0.99 cd/A(at 62.3 mA/cm 2) together with a very stable chromaticity.The contrast ratio reaches 561:1 at an on-state brightness of 1000 cd/m^2 under an ambient illumination of 140 lx.In addition,the anti-reflection layer can also enhance the transmissivity of the cathode and improve light out-coupling by the effective restraint of microcavity effects.