Monitoring the service condition of concrete structures requires the quantitative assessment of properties and corrosion rate of structural steels surrounded by concrete.A multi-cell sensor system that included a refe...Monitoring the service condition of concrete structures requires the quantitative assessment of properties and corrosion rate of structural steels surrounded by concrete.A multi-cell sensor system that included a reference electrode,a chloride content sensor,a macrocell current unit and an electrical resistance measurement unit was developed.This system provided the following important electrochemical data in the cover-zone concrete on site:open circuit potential,macrocell current from anodes to cathode,chloride profile,concrete resistance and corrosion rate of built-in anodes.The experimental results show that the macrocell current increases when the chloride content in concrete is higher.Thus,monitoring the chloride content is a good method for monitoring the corrosion state.The chloride ion content and cover depth are the key factors that affect the electrical resistance of concrete.Without considering the temperature and time,a simplified model of the instantaneous corrosion rate of steel rebar in a concrete structure based on the measured chloride contents and concrete resistance was proposed.The test results further prove the reliability of this simplified predicting model.展开更多
Chloride-induced corrosion of the reinforcement is considered as one of the major mechanisms resulting in the reduction of structural resistance of reinforced concrete structural elements located in marine and other a...Chloride-induced corrosion of the reinforcement is considered as one of the major mechanisms resulting in the reduction of structural resistance of reinforced concrete structural elements located in marine and other aggressive environments. A study of reinforced concrete structures located at the Fangcheng dock in the Beibu Gulf port, China, was present. The result from field survey indicates that the concrete cover depth and chloride diffusion coefficient fit best normal distribution and lognormal distribution, respectively. The service life of structure is about 55 a, while initiation time is 45 a. Sensitivity analysis indicates that the most influential factor of the structure service life prediction is concrete cover, followed by diffusion coefficient, diffusion decay index, critical chloride concentration, surface chloride concentration, current density and localized pitting corrosion. Finally, the effects of diffusion decay index and critical chloride concentration on structure service life prediction are discussed.展开更多
Reinforced concrete(RC) load bearing wall is widely used in high-rise and mid-rise buildings. Due to the number of walls in plan and reduction in lateral force portion, this system is not only stronger against earthqu...Reinforced concrete(RC) load bearing wall is widely used in high-rise and mid-rise buildings. Due to the number of walls in plan and reduction in lateral force portion, this system is not only stronger against earthquakes, but also more economical. The effect of progressive collapse caused by removal of load bearing elements, in various positions in plan and stories of the RC load bearing wall system was evaluated by nonlinear dynamic and static analyses. For this purpose, three-dimensional model of 10-story structure was selected. The analysis results indicated stability, strength and stiffness of the RC load-bearing wall system against progressive collapse. It was observed that the most critical condition for removal of load bearing walls was the instantaneous removal of the surrounding walls located at the corners of the building where the sections of the load bearing elements were changed. In this case, the maximum vertical displacement was limited to 6.3 mm and the structure failed after applying the load of 10 times the axial load bored by removed elements. Comparison between the results of the nonlinear dynamic and static analyses demonstrated that the "load factor" parameter was a reasonable criterion to evaluate the progressive collapse potential of the structure.展开更多
In this study,a nonlinear three-dimensional hydrocode numerical simulation was carried out using AUTODYN-3D to investigate the effect of blasting of a high explosive material(TNT)against several configurations of the ...In this study,a nonlinear three-dimensional hydrocode numerical simulation was carried out using AUTODYN-3D to investigate the effect of blasting of a high explosive material(TNT)against several configurations of the composite structure.Several numerical models were carried out to study the effect of varying the thickness of the walls and the effect of adding an air layer or aluminum foam layer inside two layers of concrete in mitigating the effect of blast waves on the structure walls.The results showed that increasing the thickness of walls has a good effect on mitigating the effect of blast waves.When a layer of air was added,the effect of blast waves was exaggerated,while when a layer of aluminum foam was added the blast wave effects were mitigated with a reasonable percentage.展开更多
The reinforcement corrosion is the pitting corrosion of chloride corrosion.Hence,in this study,the variations of reinforcement tensile strength due to stress concentration of pitting corrosion are analyzed.The stress ...The reinforcement corrosion is the pitting corrosion of chloride corrosion.Hence,in this study,the variations of reinforcement tensile strength due to stress concentration of pitting corrosion are analyzed.The stress concentration consequence of corrosion on the reinforcement tensile capacity is studied utilizing tension tests and creating different ABAQUS software models.According to the modelling in various corrosion depths,strength reduction is less than 5%in corrosion with pit radius to reinforcement diameter ratio up to 0.3 and for corrosions higher than 0.4,the measure of capacity reduction is increased more to 30%.展开更多
A nonlinear finite element model of the nut post reinforced concrete (RC) structure of the safety mechanism in the Three Gorges Project (TGP) ship lift was built by ANSYS software. Some irregular structures such a...A nonlinear finite element model of the nut post reinforced concrete (RC) structure of the safety mechanism in the Three Gorges Project (TGP) ship lift was built by ANSYS software. Some irregular structures such as the nut post and the rotary rod were divided by curved surface into a series of regular parts, and the structures were all meshed to hexahedron. Constraint equations were defined between two interfaces with different element sizes and mesh patterns. PRETS179 elements were used to simulate the preload in the tendons and the pre-stressed screws, and the loss of prestressing force was calculated. Five extreme load cases were analyzed. The stress of each part in the structure was obtained. The results indicate that the maximum compressive stress of concrete C35 is 24.13 MPa, so the concrete may be partially crushed; the maximum tensile stress of the grouting motar is 6.73 MPa, so the grouting motar may partially fracture; the maximum yon Mises stress of the rotary rod is 648.70 MPa, therefore the rotary rod may partially yield.展开更多
基金Project(200632800003-11) supported by Western Communications Construction Scientific and Technological Project in China
文摘Monitoring the service condition of concrete structures requires the quantitative assessment of properties and corrosion rate of structural steels surrounded by concrete.A multi-cell sensor system that included a reference electrode,a chloride content sensor,a macrocell current unit and an electrical resistance measurement unit was developed.This system provided the following important electrochemical data in the cover-zone concrete on site:open circuit potential,macrocell current from anodes to cathode,chloride profile,concrete resistance and corrosion rate of built-in anodes.The experimental results show that the macrocell current increases when the chloride content in concrete is higher.Thus,monitoring the chloride content is a good method for monitoring the corrosion state.The chloride ion content and cover depth are the key factors that affect the electrical resistance of concrete.Without considering the temperature and time,a simplified model of the instantaneous corrosion rate of steel rebar in a concrete structure based on the measured chloride contents and concrete resistance was proposed.The test results further prove the reliability of this simplified predicting model.
基金Project(41274012) supported by the National Natural Science Foundation of China
文摘Chloride-induced corrosion of the reinforcement is considered as one of the major mechanisms resulting in the reduction of structural resistance of reinforced concrete structural elements located in marine and other aggressive environments. A study of reinforced concrete structures located at the Fangcheng dock in the Beibu Gulf port, China, was present. The result from field survey indicates that the concrete cover depth and chloride diffusion coefficient fit best normal distribution and lognormal distribution, respectively. The service life of structure is about 55 a, while initiation time is 45 a. Sensitivity analysis indicates that the most influential factor of the structure service life prediction is concrete cover, followed by diffusion coefficient, diffusion decay index, critical chloride concentration, surface chloride concentration, current density and localized pitting corrosion. Finally, the effects of diffusion decay index and critical chloride concentration on structure service life prediction are discussed.
文摘Reinforced concrete(RC) load bearing wall is widely used in high-rise and mid-rise buildings. Due to the number of walls in plan and reduction in lateral force portion, this system is not only stronger against earthquakes, but also more economical. The effect of progressive collapse caused by removal of load bearing elements, in various positions in plan and stories of the RC load bearing wall system was evaluated by nonlinear dynamic and static analyses. For this purpose, three-dimensional model of 10-story structure was selected. The analysis results indicated stability, strength and stiffness of the RC load-bearing wall system against progressive collapse. It was observed that the most critical condition for removal of load bearing walls was the instantaneous removal of the surrounding walls located at the corners of the building where the sections of the load bearing elements were changed. In this case, the maximum vertical displacement was limited to 6.3 mm and the structure failed after applying the load of 10 times the axial load bored by removed elements. Comparison between the results of the nonlinear dynamic and static analyses demonstrated that the "load factor" parameter was a reasonable criterion to evaluate the progressive collapse potential of the structure.
文摘In this study,a nonlinear three-dimensional hydrocode numerical simulation was carried out using AUTODYN-3D to investigate the effect of blasting of a high explosive material(TNT)against several configurations of the composite structure.Several numerical models were carried out to study the effect of varying the thickness of the walls and the effect of adding an air layer or aluminum foam layer inside two layers of concrete in mitigating the effect of blast waves on the structure walls.The results showed that increasing the thickness of walls has a good effect on mitigating the effect of blast waves.When a layer of air was added,the effect of blast waves was exaggerated,while when a layer of aluminum foam was added the blast wave effects were mitigated with a reasonable percentage.
文摘The reinforcement corrosion is the pitting corrosion of chloride corrosion.Hence,in this study,the variations of reinforcement tensile strength due to stress concentration of pitting corrosion are analyzed.The stress concentration consequence of corrosion on the reinforcement tensile capacity is studied utilizing tension tests and creating different ABAQUS software models.According to the modelling in various corrosion depths,strength reduction is less than 5%in corrosion with pit radius to reinforcement diameter ratio up to 0.3 and for corrosions higher than 0.4,the measure of capacity reduction is increased more to 30%.
基金Project (SPKJ 016-06) supported by the Key Research Project of State Power CorporationProject (2004AC101D31) supported the Key Scientific Research Project of Hubei Province, China
文摘A nonlinear finite element model of the nut post reinforced concrete (RC) structure of the safety mechanism in the Three Gorges Project (TGP) ship lift was built by ANSYS software. Some irregular structures such as the nut post and the rotary rod were divided by curved surface into a series of regular parts, and the structures were all meshed to hexahedron. Constraint equations were defined between two interfaces with different element sizes and mesh patterns. PRETS179 elements were used to simulate the preload in the tendons and the pre-stressed screws, and the loss of prestressing force was calculated. Five extreme load cases were analyzed. The stress of each part in the structure was obtained. The results indicate that the maximum compressive stress of concrete C35 is 24.13 MPa, so the concrete may be partially crushed; the maximum tensile stress of the grouting motar is 6.73 MPa, so the grouting motar may partially fracture; the maximum yon Mises stress of the rotary rod is 648.70 MPa, therefore the rotary rod may partially yield.