A heterodyne collective scattering system has been designed and developed to investigate the turbulent transport of core plasma on J-TEXT.A dual-HCN laser which consists of two separately pumped HCN gas lasers at 337...A heterodyne collective scattering system has been designed and developed to investigate the turbulent transport of core plasma on J-TEXT.A dual-HCN laser which consists of two separately pumped HCN gas lasers at 337μm has been developed as the laser source of the scattering system.The intermediate frequency(IF)is~1 MHz when there is a 4μm cavity length difference and capable to maintain stability more than 5 h without manual operation.Detection channels at three different angles(2≤k_(⊥)≤12 cm^(-1))have been installed with Schottky barrier diode mixers of 893 GHz.The sampling frequency of the acquisition system is6 MHz to observe low-frequency density fluctuations.Initial experimental results have been detected and more results can be expected in future experiments.展开更多
A CW CO2 laser collective Thomson scattering diagnostics was developed to measure plasma density fluctuations on the HT-7 tokamak. The design and construction of CO2 laser scattering apparatus is described. The laser ...A CW CO2 laser collective Thomson scattering diagnostics was developed to measure plasma density fluctuations on the HT-7 tokamak. The design and construction of CO2 laser scattering apparatus is described. The laser source is a continuous-wave CO2 laser with a cavity length of 1.9 m and a power output of about 10 W at 10.6 μm. The k-resolution of the system is △k ≈ 3.2 cm-1. The preliminary data from the diagnostic is presented.展开更多
基金the National Key R&D Program of China(Nos.2017YFE0302000,2018YFE0310300 and 2018YFE0309101)National Natural Science Foundation of China(Nos.51821005 and 11905080)。
文摘A heterodyne collective scattering system has been designed and developed to investigate the turbulent transport of core plasma on J-TEXT.A dual-HCN laser which consists of two separately pumped HCN gas lasers at 337μm has been developed as the laser source of the scattering system.The intermediate frequency(IF)is~1 MHz when there is a 4μm cavity length difference and capable to maintain stability more than 5 h without manual operation.Detection channels at three different angles(2≤k_(⊥)≤12 cm^(-1))have been installed with Schottky barrier diode mixers of 893 GHz.The sampling frequency of the acquisition system is6 MHz to observe low-frequency density fluctuations.Initial experimental results have been detected and more results can be expected in future experiments.
文摘A CW CO2 laser collective Thomson scattering diagnostics was developed to measure plasma density fluctuations on the HT-7 tokamak. The design and construction of CO2 laser scattering apparatus is described. The laser source is a continuous-wave CO2 laser with a cavity length of 1.9 m and a power output of about 10 W at 10.6 μm. The k-resolution of the system is △k ≈ 3.2 cm-1. The preliminary data from the diagnostic is presented.