Capillary columns are used in both capillary liquid chromatography and capillary electrochromatography. The design for capillary liquid chromatography is discussed in comparison with capillary gas chromatography. The ...Capillary columns are used in both capillary liquid chromatography and capillary electrochromatography. The design for capillary liquid chromatography is discussed in comparison with capillary gas chromatography. The difference of diffusion coefficient in gas and liquid phase is a key role. The study for obtaining a high performance capillary liquid chromatography is discussed. Capillary electrochromatography is recently interesting for its instinct ability to realize a high performance chromatography. Capillary electrochromatography with and without pressurized flow is reviewed briefly. Instrumentation for capillary electrochromatography with pressurized flow is discussed. The port of splitting, and gradient elution of both solution and potential are described. The new findings of both the variation of column resistance and capacity factor according to the value of applied electric voltage are also discussed.展开更多
The chemiluminescence (CL) generated from the hydrogen peroxide oxided by periodate could be enhanced differently by polyhydrophenols, such as pyrogallol, phloroglucinol, pyrocatechol, resorcinol and parodioxybenzene....The chemiluminescence (CL) generated from the hydrogen peroxide oxided by periodate could be enhanced differently by polyhydrophenols, such as pyrogallol, phloroglucinol, pyrocatechol, resorcinol and parodioxybenzene. Furthermore, the CL could be improved in the presence of the trace non-polar organic solvent, the possible mechanism was proposed. Based on which a sensitive CL method for polyhydrophenols has been built. The linear ranges of determination for pyrogallol, phloroglucinol, pyrocatechol, resorcinol and parodioxybenzene were 1×10-5~2×10-7 mol/L, 1×10-3~1×10-5 mol/L, 1×10-4~6×10-6 mol/L, 1×10-3~2×10-5 mol/L and 1×10-3~6×10-5 mol/L, respectively, and their detection limits were 7.2×10-8 mol/L, 6.8×10-6 mol/L, 2.1×10-6 mol/L , 7.1×10-6 mol/L and 2.2×10-5 mol/L respectively.展开更多
文摘Capillary columns are used in both capillary liquid chromatography and capillary electrochromatography. The design for capillary liquid chromatography is discussed in comparison with capillary gas chromatography. The difference of diffusion coefficient in gas and liquid phase is a key role. The study for obtaining a high performance capillary liquid chromatography is discussed. Capillary electrochromatography is recently interesting for its instinct ability to realize a high performance chromatography. Capillary electrochromatography with and without pressurized flow is reviewed briefly. Instrumentation for capillary electrochromatography with pressurized flow is discussed. The port of splitting, and gradient elution of both solution and potential are described. The new findings of both the variation of column resistance and capacity factor according to the value of applied electric voltage are also discussed.
文摘The chemiluminescence (CL) generated from the hydrogen peroxide oxided by periodate could be enhanced differently by polyhydrophenols, such as pyrogallol, phloroglucinol, pyrocatechol, resorcinol and parodioxybenzene. Furthermore, the CL could be improved in the presence of the trace non-polar organic solvent, the possible mechanism was proposed. Based on which a sensitive CL method for polyhydrophenols has been built. The linear ranges of determination for pyrogallol, phloroglucinol, pyrocatechol, resorcinol and parodioxybenzene were 1×10-5~2×10-7 mol/L, 1×10-3~1×10-5 mol/L, 1×10-4~6×10-6 mol/L, 1×10-3~2×10-5 mol/L and 1×10-3~6×10-5 mol/L, respectively, and their detection limits were 7.2×10-8 mol/L, 6.8×10-6 mol/L, 2.1×10-6 mol/L , 7.1×10-6 mol/L and 2.2×10-5 mol/L respectively.