Numerical analysis of high‑speed railway slab tracks using calibrated and validated 3D time‑domain modelling
1
作者 A.F.Esen O.Laghrouche +4 位作者 P.K.Woodward D.Medina‑Pineda Q.Corbisez J.Y.Shih D.P.Connolly 《Railway Engineering Science》 EI 2024年第1期36-58,共23页
Concrete slabs are widely used in modern railways to increase the inherent resilient quality of the tracks,provide safe and smooth rides,and reduce the maintenance frequency.In this paper,the elastic performance of a ... Concrete slabs are widely used in modern railways to increase the inherent resilient quality of the tracks,provide safe and smooth rides,and reduce the maintenance frequency.In this paper,the elastic performance of a novel slab trackform for high-speed railways is investigated using three-dimensional finite element modelling in Abaqus.It is then compared to the performance of a ballasted track.First,slab and ballasted track models are developed to replicate the full-scale testing of track sections.Once the models are calibrated with the experimental results,the novel slab model is developed and compared against the calibrated slab track results.The slab and ballasted track models are then extended to create linear dynamic models,considering the track geodynamics,and simulating train passages at various speeds,for which the Ledsgard documented case was used to validate the models.Trains travelling at low and high speeds are analysed to investigate the track deflections and the wave propagation in the soil,considering the issues associated with critical speeds.Various train loading methods are discussed,and the most practical approach is retained and described.Moreover,correlations are made between the geotechnical parameters of modern high-speed rail and conventional standards.It is found that considering the same ground condition,the slab track deflections are considerably smaller than those of the ballasted track at high speeds,while they show similar behaviour at low speeds. 展开更多
关键词 High-speed railways Slab track New ballastless track Ballasted track Critical speeds Finite element modelling Calibration of numerical models
在线阅读 下载PDF
A Log-Penalty-Based Method for Multi-Parameters Estimation with Partly Calibrated COLD Array
2
作者 Yudi Qin Xiaoying Sun 《China Communications》 SCIE CSCD 2021年第8期271-278,共8页
In this paper,we focus on the problem of joint estimation of DOA,power and polarization angle from sparse reconstruction perspective with array gain-phase errors,where a partly calibrated cocentered orthogonal loop an... In this paper,we focus on the problem of joint estimation of DOA,power and polarization angle from sparse reconstruction perspective with array gain-phase errors,where a partly calibrated cocentered orthogonal loop and dipole(COLD)array is utilized.In detailed implementations,we first combine the output of loop and dipole in second-order statistics domain to receive the source signals completely,and then we use continuous multiplication operator to achieve gain-phase errors calibration.After compensating the gain-phase errors,we construct a log-penalty-based optimization problem to approximate`0 norm and further exploit difference of convex(DC)functions decomposition to achieve DOA.With the aid of the estimated DOAs,the power and polarization angle estimation are obtained by the least squares(LS)method.By conducting numerical simulations,we show the effectiveness and superiorities of the proposed method. 展开更多
关键词 multi-parameters estimation log penalty DC functions decomposition partly calibrated COLD array gain-phase errors
在线阅读 下载PDF
Digitally calibrated broadband dual-comb gases absorption spectral measurements
3
作者 Xinyi Chen Weipeng Zhang +1 位作者 Haoyun Wei Yan Li 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第6期114-120,共7页
From the perspective of error compensation in the sampling process, a digital calibration algorithm was studied for the processing of spectral data in dual-comb spectroscopy. In this algorithm, dynamic adaptation to p... From the perspective of error compensation in the sampling process, a digital calibration algorithm was studied for the processing of spectral data in dual-comb spectroscopy. In this algorithm, dynamic adaptation to phase fluctuations maintained constant measurement results of spectral line positions and intensities. A mode-resolved broadband absorption spectrum was obtained over the full-spectral range of the comb with a Hertz linewidth of radio frequency comb mode.The measured spectrum spanned over 10 THz, which covered the multiplexed absorption regions of mixed gases, such as CO2 and N2 O. The calibrated interferograms were also capable of direct coherent averaging in the time domain. The transmittance obtained deviated from the theoretical calculation by no more than 2% in the whole spectral span. 展开更多
关键词 dual-comb SPECTROSCOPY digital calibration
在线阅读 下载PDF
A real-time calibration method based on time-to-digital converter for accelerator timing system
4
作者 Qi-Hao Duan Liang Ge +2 位作者 Yan-Hao Jia Jie-Yu Zhu Wei Zhang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第9期127-140,共14页
The high-intensity heavy-ion accelerator facility(HIAF)is a scientific research facility complex composed of multiple cas-cade accelerators of different types,which pose a scheduling problem for devices distributed ov... The high-intensity heavy-ion accelerator facility(HIAF)is a scientific research facility complex composed of multiple cas-cade accelerators of different types,which pose a scheduling problem for devices distributed over a certain range of 2 km,involving over a hundred devices.The white rabbit,a technology-enhancing Gigabit Ethernet,has shown the capability of scheduling distributed timing devices but still faces the challenge of obtaining real-time synchronization calibration param-eters with high precision.This study presents a calibration system based on a time-to-digital converter implemented on an ARM-based System-on-Chip(SoC).The system consists of four multi-sample delay lines,a bubble-proof encoder,an edge controller for managing data from different channels,and a highly effective calibration module that benefits from the SoC architecture.The performance was evaluated with an average RMS precision of 5.51 ps by measuring the time intervals from 0 to 24,000 ps with 120,000 data for every test.The design presented in this study refines the calibration precision of the HIAF timing system.This eliminates the errors caused by manual calibration without efficiency loss and provides data support for fault diagnosis.It can also be easily tailored or ported to other devices for specific applications and provides more space for developing timing systems for particle accelerators,such as white rabbits on HIAF. 展开更多
关键词 HIAF White rabbit Calibration system Time-to-digital converter(TDC)
在线阅读 下载PDF
Pressure generation under deformation in a large-volume press
5
作者 Saisai Wang Xinyu Zhao +8 位作者 Kuo Hu Bingtao Feng Xuyuan Hou Yiming Zhang Shucheng Liu Yuchen Shang Zhaodong Liu Mingguang Yao Bingbing Liu 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第9期622-626,共5页
Deformation can change the transition pathway of materials under high pressure,thus significantly affects physical and chemical properties of matters.However,accurate pressure calibration under deformation is challeng... Deformation can change the transition pathway of materials under high pressure,thus significantly affects physical and chemical properties of matters.However,accurate pressure calibration under deformation is challenging and thereby causes relatively large pressure uncertainties in deformation experiments,resulting in the synthesis of complex multiphase materials.Here,pressure generations of three types of deformation assemblies were well calibrated in a Walker-type largevolume press(LVP)by electrical resistance measurements combined with finite element simulations(FESs).Hard Al_(2)O_(3) or diamond pistons in shear and uniaxial deformation assemblies significantly increase the efficiency of pressure generation compared with the conventional quasi-hydrostatic assembly.The uniaxial deformation assembly using flat diamond pistons possesses the highest efficiency in these deformation assemblies.This finding is further confirmed by stress distribution analysis based on FESs.With this deformation assembly,we found shear can effectively promote the transformation of C60 into diamond under high pressure and realized the synthesis of phase-pure diamond at relatively moderate pressure and temperature conditions.The present developed techniques will help improve pressure efficiencies in LVP and explore the new physical and chemical properties of materials under deformation in both science and technology. 展开更多
关键词 shear/uniaxial deformation pressure calibration finite element simulations large-volume press high pressure
在线阅读 下载PDF
Wavelength calibration and spectral analysis of vacuum ultraviolet spectroscopy in EAST
6
作者 计华健 张洪明 +6 位作者 吕波 Cheonho BAE 何梁 林子超 尹相辉 沈永才 戴舒宇 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第8期37-43,共7页
A vacuum ultraviolet(VUV)spectroscopy with a focal length of 1 m has been engineered specifically for observing edge impurity emissions in Experimental Advanced Superconducting Tokamak(EAST).In this study,wavelength c... A vacuum ultraviolet(VUV)spectroscopy with a focal length of 1 m has been engineered specifically for observing edge impurity emissions in Experimental Advanced Superconducting Tokamak(EAST).In this study,wavelength calibration for the VUV spectroscopy is achieved utilizing a zinc lamp.The grating angle and charge-coupled device(CCD)position are carefully calibrated for different wavelength positions.The wavelength calibration of the VUV spectroscopy is crucial for improving the accuracy of impurity spectral data,and is required to identify more impurity spectral lines for impurity transport research.Impurity spectra of EAST plasmas have also been obtained in the wavelength range of 50–300 nm with relatively high spectral resolution.It is found that the impurity emissions in the edge region are still dominated by low-Z impurities,such as carbon,oxygen,and nitrogen,albeit with the application of fulltungsten divertors on the EAST tokamak. 展开更多
关键词 vacuum ultraviolet spectroscopy wavelength calibration impurity spectra
在线阅读 下载PDF
Error Analysis and Compensation of Strapdown Inertial Navigation System 被引量:16
7
作者 刘勤 刘莉 祁载康 《Journal of Beijing Institute of Technology》 EI CAS 2002年第2期117-120,共4页
Based on error analysis, the influence of error sources on strapdown inertial navigation systems is discussed. And the maximum permissible component tolerances are established. In order to achieve the desired accuracy... Based on error analysis, the influence of error sources on strapdown inertial navigation systems is discussed. And the maximum permissible component tolerances are established. In order to achieve the desired accuracy (defined by circular error probability), the types of appropriate sensors are chosen. The inertial measurement unit (IMU) is composed of those sensors. It is necessary to calibrate the sensors to obtain their error model coefficients of IMU. After calibration tests, the accuracy is calculated by uniform design method and it is proved that the accuracy of IMU is satisfied for the desired goal. 展开更多
关键词 error analysis strapdown inertial navigation system uniform design method calibration test
在线阅读 下载PDF
多通道双混频时差测量系统的实现 被引量:6
8
作者 张爱敏 高小殉 +5 位作者 宁大愚 王伟波 苏志强 杜向伟 冯卫 Ai-min Xiao-xun Da-yu Wei-bo Zhi-qiang Xiang-wei 《计量学报》 CSCD 北大核心 2009年第6期-,共4页
基于双混频时差技术设计研制了8通道的频率稳定度测量系统,实现了对8路5 MHz或10 MHz频率标准的测量.当频率为10 MHz取样时间为1 s时,系统噪声本底优于2.0 X 10^(-13),取样时间为1000 s时,系统噪声本底优于2.5×10^(-16).不但可以... 基于双混频时差技术设计研制了8通道的频率稳定度测量系统,实现了对8路5 MHz或10 MHz频率标准的测量.当频率为10 MHz取样时间为1 s时,系统噪声本底优于2.0 X 10^(-13),取样时间为1000 s时,系统噪声本底优于2.5×10^(-16).不但可以满足原子时标基准原子钟组的内部比对,也可实现对一般频率标准的检定和校准. Abstract: Based on the technique of Dual Mixer Time Difference (DMTD), an 8-channel frequency stabilitymeasurement system has been developed. It realized the measurement of 8-channel 5 MHz and 10 MHz frequencystandards. For 10 MHz frequency, the noise floor is better than 2.0 ×10^(-13)/1 s, 2.5× 10^(-16)/1000 s. It can not only satisfy the internal comparison of time scale ensemble, but also can realize the calibration of normal frequency standards. 展开更多
关键词 多通道 混频 时差 测量系统 Measurement System 系统噪声 取样时间 频率标准 TIME Difference calibration 频率稳定度 TIME scale comparison 原子时标 设计研制 本底 原子钟 better Mixer Based
在线阅读 下载PDF
目标函数对HEC-HMS模型参数率定的影响研究 被引量:15
9
作者 邓霞 董晓华 薄会娟 《水电能源科学》 北大核心 2010年第8期17-19,共3页
以清江流域(渔峡口以上)为例,采用分布式水文模型HEC-HMS研究了模型参数自动率定功能,并选取参数优化的目标函数,以探讨目标函数的选取对模型模拟结果的影响,并分析其原因。结果表明,峰值加权均方根误差目标函数的模拟效果最佳,为选取... 以清江流域(渔峡口以上)为例,采用分布式水文模型HEC-HMS研究了模型参数自动率定功能,并选取参数优化的目标函数,以探讨目标函数的选取对模型模拟结果的影响,并分析其原因。结果表明,峰值加权均方根误差目标函数的模拟效果最佳,为选取其他洪水模拟参数优化目标函数提供了理论依据。 展开更多
关键词 优化目标函数 HEC-HMS 分布式水文模型 参数率定 影响研究 CALIBRATION Model Objective FUNCTION Influence 参数优化 模拟结果 均方根误差 效果最佳 清江流域 模型参数 模拟参数 理论依据 自动 峡口 加权
在线阅读 下载PDF
用于激光尾波场中电子束电荷测量的积分束流仪标定 被引量:2
10
作者 董克攻 朱斌 +4 位作者 吴玉迟 苏春晓 于瑞珍 谷渝秋 王晓方 《强激光与粒子束》 EI CAS CSCD 北大核心 2010年第12期2819-2823,共5页
利用数字信号发生器及示波器对积分束流仪(ICT)的输入输出特性进行了标定,给出了不同脉冲宽度及幅度的输入信号与ICT输出结果的电荷量比值关系、输入脉冲对ICT的输出脉冲宽度的影响以及ICT对连续脉冲信号的输出响应等。标定结果显示:IC... 利用数字信号发生器及示波器对积分束流仪(ICT)的输入输出特性进行了标定,给出了不同脉冲宽度及幅度的输入信号与ICT输出结果的电荷量比值关系、输入脉冲对ICT的输出脉冲宽度的影响以及ICT对连续脉冲信号的输出响应等。标定结果显示:ICT的输入输出满足很好的线性关系;当输入连续脉冲的间隔小于一定程度时,ICT将会视为一个信号输出;ICT的输出脉冲形状及脉冲宽度与输入信号的形状及幅度无关。 展开更多
关键词 激光尾波场 电子束 电荷测量 积分 束流 标定 electron beam charge measurement calibration 输入输出特性 输入信号 脉冲宽度 ICT 连续脉冲 数字信号发生器 信号输出 线性关系 输出响应 输出结果 脉冲形状
在线阅读 下载PDF
GYRO BIAS ON-ORBIT CALIBRATION FOR MICRO SATELLITES 被引量:1
11
作者 郁丰 刘建业 熊智 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2007年第4期300-304,共5页
According to gyro application in micro-satellites, a new gyro bias real-time on-orbit calibration technology is presented and it is independent of any other sensors. The approach relies on gyro on-orbit measurements r... According to gyro application in micro-satellites, a new gyro bias real-time on-orbit calibration technology is presented and it is independent of any other sensors. The approach relies on gyro on-orbit measurements restricted by satellite attitude dynamics and estimates the gyro bias generated when the gyro is electrified. Observability of the calibration model is analyzed and applicable conditions of the technology are derived. Simulation results indicate that the calibration algorithm is accurate and robust at gyro sampling rate, and its convergence speed is fast. Within the given attitude dynamics model error, the convergence time is less than 100 s and the convergence accuracy is about 1.0 (°)/h. Calibration performance can meet requirements of spacecraft operations. 展开更多
关键词 on-orbit calibration gyro bias Kalman filter micro satellite
在线阅读 下载PDF
Fast estimation of Michaelis-Menten constant of arylesterase with a pair of medium concentrations of substrate 被引量:4
12
作者 廖飞 杨晓 +2 位作者 周岐新 曾昭淳 左渝萍 《Journal of Medical Colleges of PLA(China)》 CAS 2003年第5期312-316,共5页
Objective: To investigate the reliability for fast estimation of Michaelis-Menten constant (Km) with calibrated specific activity at only two medium concentrations of substrate by both simulation and experimentation w... Objective: To investigate the reliability for fast estimation of Michaelis-Menten constant (Km) with calibrated specific activity at only two medium concentrations of substrate by both simulation and experimentation with arylesterase (ArE)as model. Methods: Initial rates were simulated by randomly inserting uniform absolute error, and the experimental initial rates of ArE were determined by measuring the increaser of product absorbance. Calibrated specific activities at two substrate concentrations were obtained by regression analysis, and Km was calculated according to Michaelis-Menten equation. Results: By simulation with calibrated specific activities at two medium substrate concentrations, Km could be calculated according to Michaelis-Menten equation with reasonable precision and accuracy. By experimentation with substrates of 2-naphthyl acetate, phenyl acetate, and p-nitrophenyl acetate, there were no differences between the mean and SD of Km of ArE for either substrate by this linear kinetic method and the Lineweaver-Burk plot. Conclusion: This linear kinetic method was reliable for fast estimation of the Km of some specified enzyme on its substrate of lower solubility or lower sensitivity for quantification by common methods. 展开更多
关键词 Michaelis-Menten constant linear kinetic method calibrated specific activity simulation ARYLESTERASE
在线阅读 下载PDF
某飞行器三角翼动力学有限元模型与试验数据相关分析原理及实现 被引量:2
13
作者 李双 荣克林 高庆 《强度与环境》 2006年第4期1-7,共7页
试验数据和有限元数据相关分析修改有限元模型是工程界不断追求的技术,以解决模型简化存在的误差问题。目前存在着频率、振型、频响函数相关的几种方法,本文对试验数据和有限元分析数据相关的理论方法进行简要介绍,对CAE Calibrator软... 试验数据和有限元数据相关分析修改有限元模型是工程界不断追求的技术,以解决模型简化存在的误差问题。目前存在着频率、振型、频响函数相关的几种方法,本文对试验数据和有限元分析数据相关的理论方法进行简要介绍,对CAE Calibrator软件的使用方法也进行了说明。并进行了某飞行器机翼的有限元模态计算和模态试验,着重用CAE Calibrator软件进行有限元分析模型与试验数据(频率和振型)相关性分析,修改了有限元模型,修改的设计变量合理,修改后的计算结果与试验结果(频率、振型)符合很好。 展开更多
关键词 CAE calibrator有限元模型 模态数据 相关性
在线阅读 下载PDF
用Calibre工具对FFT芯片进行物理验证 被引量:1
14
作者 王仁平 于映 《电子科技》 2008年第3期16-20,共5页
FFT芯片在Astro工具中版图设计一旦完成,必须进行设计规则检查以确保版图设计的正确性。违反规则的版图设计将成为电路生产的隐患,因此,必须在sign-off之前检查出并改正。介绍了如何使用Mentor公司Calibre工具对Astro工具导出FFT芯片的... FFT芯片在Astro工具中版图设计一旦完成,必须进行设计规则检查以确保版图设计的正确性。违反规则的版图设计将成为电路生产的隐患,因此,必须在sign-off之前检查出并改正。介绍了如何使用Mentor公司Calibre工具对Astro工具导出FFT芯片的GDSⅡ文件进行设计规则检查、天线规则检查、电学规则检查和版图与电路图一致性检查,并对检查中出现的问题提出相应的解决办法。 展开更多
关键词 Calibre 物理验证 设计规则检查 版图与原理图一致性检查
在线阅读 下载PDF
Calibration Scheme Under Spherical Coordinates for Magnetic Tracker Used in VR System
15
作者 徐彤 刘莉萍 +1 位作者 刘越 王涌天 《Journal of Beijing Institute of Technology》 EI CAS 2002年第3期256-258,共3页
A calibration scheme under spherical coordinates is described for a magnetic tracker used in VR (virtual reality) system. A look up table containing data of tracked values for certain positions in the working space, ... A calibration scheme under spherical coordinates is described for a magnetic tracker used in VR (virtual reality) system. A look up table containing data of tracked values for certain positions in the working space, spe cified in spherical coordinates, is generated first, which is then used to calibrate the tracking results by a two dimensional interpolation. The scheme can effectively correct the static errors in the magnetic tracking system. The employment of spherical coordinates significantly reduces the calculation complexity in calibration. 展开更多
关键词 CALIBRATION magnetic tracking virtual reality
在线阅读 下载PDF
利用恒星辐射测量整层大气透过率的多目标星定标 被引量:6
16
作者 朱明 詹杰 《强激光与粒子束》 EI CAS CSCD 北大核心 2010年第12期2843-2847,共5页
介绍了整层大气透过率测量仪及其测量原理和Langley-Plot定标方法,提出了基于恒星整层大气透过率仪测量大气透过率的多目标星定标方法,并分别进行了K,A光谱类型恒星定标试验,得到了基于K,A两种光谱类型恒星辐射的定标值。对多目标星定... 介绍了整层大气透过率测量仪及其测量原理和Langley-Plot定标方法,提出了基于恒星整层大气透过率仪测量大气透过率的多目标星定标方法,并分别进行了K,A光谱类型恒星定标试验,得到了基于K,A两种光谱类型恒星辐射的定标值。对多目标星定标方法与单颗恒星的Langley-Plot定标方法进行了对比实验,验证了多目标星定标方法的合理性与准确性。当实时测量同类型的恒星辐射整层大气透过率时,就可以根据对应的定标参数进行测量研究。 展开更多
关键词 恒星 辐射测量 大气透过率 多目标 定标方法 TOTAL study CALIBRATION 光谱类型 实时测量 对比实验 测量原理 测量研究 准确性 合理性 测量仪 验证 试验 参数
在线阅读 下载PDF
A commentary review on the use of normalized diff erence vegetation index(NDVI)in the era of popular remote sensing 被引量:30
17
作者 Sha Huang Lina Tang +2 位作者 Joseph P.Hupy Yang Wang Guofan Shao 《Journal of Forestry Research》 SCIE CAS CSCD 2021年第1期1-6,共6页
The Normalized Diff erence Vegetation Index(NDVI),one of the earliest remote sensing analytical products used to simplify the complexities of multi-spectral imagery,is now the most popular index used for vegetation as... The Normalized Diff erence Vegetation Index(NDVI),one of the earliest remote sensing analytical products used to simplify the complexities of multi-spectral imagery,is now the most popular index used for vegetation assessment.This popularity and widespread use relate to how an NDVI can be calculated with any multispectral sensor with a visible and a near-IR band.Increasingly low costs and weights of multispectral sensors mean they can be mounted on satellite,aerial,and increasingly—Unmanned Aerial Systems(UAS).While studies have found that the NDVI is effective for expressing vegetation status andquantified vegetation attributes,its widespread use and popularity,especially in UAS applications,carry inherent risks of misuse with end users who received little to no remote sensing education.This article summarizes the progress of NDVI acquisition,highlights the areas of NDVI application,and addresses the critical problems and considerations in using NDVI.Detailed discussion mainly covers three aspects:atmospheric eff ect,saturation phenomenon,and sensor factors.The use of NDVI can be highly eff ective as long as its limitations and capabilities are understood.This consideration is particularly important to the UAS user community. 展开更多
关键词 NDVI Atmospheric eff ect Saturation phenomenon Calibration MULTISPECTRAL Near infrared UAS Drone remote sensing
在线阅读 下载PDF
Performances of different efficiency calibration methods of high-purity-germanium gamma-ray spectrometry in an inter-comparison exercise 被引量:7
18
作者 Bao-Lu Yang Qiang Zhou +4 位作者 Jing Zhang Shuai-Mo Yao Ze-Shu Li Wen-Hong Li Fei Tuo 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第3期9-14,共6页
This study reports the performances of efficiency calibrations for high-purity-germanium gamma-ray spectrometry using the source-, Laboratory Sourceless Object Calibration Software(LabSOCS)-and ANGLE-based methods in ... This study reports the performances of efficiency calibrations for high-purity-germanium gamma-ray spectrometry using the source-, Laboratory Sourceless Object Calibration Software(LabSOCS)-and ANGLE-based methods in an inter-comparison exercise. Although the results of LabSOCS and ANGLE for ^(241)Am emitting lowenergy gamma rays were not very satisfactory, all of the three efficiency calibration methods passed acceptance criteria. The results confirmed the reliability of the calculation codes ANGLE and LabSOCS as alternative efficiency calibration methods in high-purity-germanium gamma spectrometry. This study is likely to promote the further application of the ANGLE and LabSOCS calculation codes in radioactivity measurements. 展开更多
关键词 EFFICIENCY CALIBRATION ANGLE Laboratory Sourceless Object CALIBRATION Software (LabSOCS) GAMMA-RAY SPECTROMETRY
在线阅读 下载PDF
Unfolding analysis of LaBr3:Ce gamma spectrum with a detector response matrix constructing algorithm based on energy resolution calibration 被引量:12
19
作者 Rui Shi Xian-Guo Tuo +4 位作者 Huai-Liang Li Yang-Yang Xu Fan-Rong Shi Jian-Bo Yang Yong Luo 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第1期23-31,共9页
With respect to the gamma spectrum, the energy resolution improves with increase in energy. The counts of full energy peak change with energy, and this approximately complies with the Gaussian distribution. This study... With respect to the gamma spectrum, the energy resolution improves with increase in energy. The counts of full energy peak change with energy, and this approximately complies with the Gaussian distribution. This study mainly examines a method to deconvolve the LaBr_3:Ce gamma spectrum with a detector response matrix constructing algorithm based on energy resolution calibration.In the algorithm, the full width at half maximum(FWHM)of full energy peak was calculated by the cubic spline interpolation algorithm and calibrated by a square root of a quadratic function that changes with the energy. Additionally, the detector response matrix was constructed to deconvolve the gamma spectrum. Furthermore, an improved SNIP algorithm was proposed to eliminate the background. In the experiment, several independent peaks of ^(152)Eu,^(137)Cs, and ^(60)Co sources were detected by a LaBr_3:Ce scintillator that were selected to calibrate the energy resolution. The Boosted Gold algorithm was applied to deconvolve the gamma spectrum. The results showed that the peak position difference between the experiment and the deconvolution was within ± 2 channels and the relative error of peak area was approximately within 0.96–6.74%. Finally, a ^(133) Ba spectrum was deconvolved to verify the efficiency and accuracy of the algorithm in unfolding the overlapped peaks. 展开更多
关键词 Detector response MATRIX Energy resolution CALIBRATION LaBr3:Ce scintillator SNIP background elimination Boosted Gold DECONVOLUTION ALGORITHM
在线阅读 下载PDF
Mixed-effects modeling for tree height prediction models of Oriental beech in the Hyrcanian forests 被引量:8
20
作者 Siavash Kalbi Asghar Fallah +2 位作者 Pete Bettinger Shaban Shataee Rassoul Yousefpour 《Journal of Forestry Research》 SCIE CAS CSCD 2018年第5期1195-1204,共10页
Height–diameter relationships are essential elements of forest assessment and modeling efforts.In this work,two linear and eighteen nonlinear height–diameter equations were evaluated to find a local model for Orient... Height–diameter relationships are essential elements of forest assessment and modeling efforts.In this work,two linear and eighteen nonlinear height–diameter equations were evaluated to find a local model for Oriental beech(Fagus orientalis Lipsky) in the Hyrcanian Forest in Iran.The predictive performance of these models was first assessed by different evaluation criteria: adjusted R^2(R^2_(adj)),root mean square error(RMSE),relative RMSE(%RMSE),bias,and relative bias(%bias) criteria.The best model was selected for use as the base mixed-effects model.Random parameters for test plots were estimated with different tree selection options.Results show that the Chapman–Richards model had better predictive ability in terms of adj R^2(0.81),RMSE(3.7 m),%RMSE(12.9),bias(0.8),%Bias(2.79) than the other models.Furthermore,the calibration response,based on a selection of four trees from the sample plots,resulted in a reduction percentage for bias and RMSE of about 1.6–2.7%.Our results indicate that the calibrated model produced the most accurate results. 展开更多
关键词 Random effects Tree height CALIBRATION Sangdeh forest Chapman–Richards model Oriental beech
在线阅读 下载PDF