In order to realize the elevation angle estimation for low-altitude targets at a low computational cost, a generalized multiple signal classification (GMUSIC) algorithm based on unitary transform is proposed, i.e., ...In order to realize the elevation angle estimation for low-altitude targets at a low computational cost, a generalized multiple signal classification (GMUSIC) algorithm based on unitary transform is proposed, i.e., the DU-GMUSlC algorithm. Firstly, the covariance matrix of received data is used to construct the Centro- Hermitian matrix. Then, the real-domain GMUSIC algorithm is used to implement the initial angle estimation, and the multipath attenuation coefficient is calculated in succession. Finally, the attenuation coefficient is taken into account in the GMUSIC method to carry out the secondary angle estimation which is beneficial to further improvement of the angle estimation accuracy. This method can meet requirements of low-angle accuracy as well as lower computational burden. Simulation results prove the correctness and effectiveness of the proposed algorithm. Moreover, field experiment data are used to further validate the effectiveness of this method.展开更多
In this study,we aimed to determine the radiation parameters of some potential bioactive compounds.1-Aryl-3-dibenzylamino-propane-1-on hydrochloride type Mannich bases were synthesized via classical conventional heati...In this study,we aimed to determine the radiation parameters of some potential bioactive compounds.1-Aryl-3-dibenzylamino-propane-1-on hydrochloride type Mannich bases were synthesized via classical conventional heating method.Aryl part was changed as phenyl(C6H5),4-methylphenyl(4-CH3C6H4),4-fluorophenyl(4-FC6H4),4-nitrophenyl(4-NO2C6H4),4-chlorophenyl(4-ClC6H4),4-bromophenyl(4-BrC6H4),and 2-thienyl(C4H3S-2-yl).Mass attenuation coefficient(μm),effective atomic number(Zeff)and effective electron density(Nel)of compounds were determined experimentally and theoretically for at 8.040,8.910,13.40,14.96,17.48,19.61,22.16,24.94,32.19,36.38,44.48,50.38and 59.54keV photon energies by using an HPGe detector with a resolution of 182eV at 5.9keV.Radiation parameters of these compounds which can be anti-cancer drug candidate were given in the tables.The results show that phenyl ring behave like thiophene ring in terms of radiation absorption.It is thought that the results of study may drive allow the development of drug candidate new compounds in medical oncology.展开更多
基金supported by the National Natural Science Foundation of China(61101224)the Research on the Altitude Measurement Method for VHF Radar under the Complicated Environment
文摘In order to realize the elevation angle estimation for low-altitude targets at a low computational cost, a generalized multiple signal classification (GMUSIC) algorithm based on unitary transform is proposed, i.e., the DU-GMUSlC algorithm. Firstly, the covariance matrix of received data is used to construct the Centro- Hermitian matrix. Then, the real-domain GMUSIC algorithm is used to implement the initial angle estimation, and the multipath attenuation coefficient is calculated in succession. Finally, the attenuation coefficient is taken into account in the GMUSIC method to carry out the secondary angle estimation which is beneficial to further improvement of the angle estimation accuracy. This method can meet requirements of low-angle accuracy as well as lower computational burden. Simulation results prove the correctness and effectiveness of the proposed algorithm. Moreover, field experiment data are used to further validate the effectiveness of this method.
文摘In this study,we aimed to determine the radiation parameters of some potential bioactive compounds.1-Aryl-3-dibenzylamino-propane-1-on hydrochloride type Mannich bases were synthesized via classical conventional heating method.Aryl part was changed as phenyl(C6H5),4-methylphenyl(4-CH3C6H4),4-fluorophenyl(4-FC6H4),4-nitrophenyl(4-NO2C6H4),4-chlorophenyl(4-ClC6H4),4-bromophenyl(4-BrC6H4),and 2-thienyl(C4H3S-2-yl).Mass attenuation coefficient(μm),effective atomic number(Zeff)and effective electron density(Nel)of compounds were determined experimentally and theoretically for at 8.040,8.910,13.40,14.96,17.48,19.61,22.16,24.94,32.19,36.38,44.48,50.38and 59.54keV photon energies by using an HPGe detector with a resolution of 182eV at 5.9keV.Radiation parameters of these compounds which can be anti-cancer drug candidate were given in the tables.The results show that phenyl ring behave like thiophene ring in terms of radiation absorption.It is thought that the results of study may drive allow the development of drug candidate new compounds in medical oncology.