A charged particle array named MATE-PA,which serves as an auxiliary detector system for a Multi-purpose Active-target Time projection chamber used in nuclear astrophysical and exotic beam Experiments(MATE),was constru...A charged particle array named MATE-PA,which serves as an auxiliary detector system for a Multi-purpose Active-target Time projection chamber used in nuclear astrophysical and exotic beam Experiments(MATE),was constructed.The array comprised of 20 single-sided strip-silicon detectors covering approximately 10%of the solid angle.The detectors facilitated the detection of reaction-induced charged particles that penetrate the active volume of the MATE.The performance of MATE-PA has been experimentally studied using an alpha source and a 36-MeV 14 N beam injected into the MATE chamber on the radioactive ion beam line in Lanzhou(RIBLL).The chamber was filled with a gas mixture of 95%4 He and 5%CO_(2) at a pressure of 500 mbar.The results indicated good separation of light-charged particles using the forward double-layer silicon detectors of MATE-PA.The energy resolution of the Si detectors was deduced to be approximately 1%(σ)for an energy loss of approximately 10 MeV caused by theαparticles.The inclusion of MATE-PA improves particle identification and increases the dynamic range of the kinetic energy of charged particles,particularly that of theαparticles,up to approximately 15 MeV.展开更多
The spatial resolution of a commercial two-dimensional(2D)ionization chamber(IC)array is limited by the size of the individual detector and the center-to-center distance between sensors.For dose distributions with are...The spatial resolution of a commercial two-dimensional(2D)ionization chamber(IC)array is limited by the size of the individual detector and the center-to-center distance between sensors.For dose distributions with areas of steep dose gradients,inter-detector dose values are derived by the interpolation of nearby detector readings in the conventional mathematical interpolation of 2D IC array measurements.This may introduce significant errors,particularly in proton spot scanning radiotherapy.In this study,by combining logfile-based reconstructed dose values and detector measurements with the Laplacian pyramid image blending method,a novel method is proposed to obtain a reformatted dose distribution that provides an improved estimation of the delivered dose distribution with high spatial resolution.Meanwhile,the similarity between the measured original data and the downsampled logfilebased reconstructed dose is regarded as the confidence of the reformatted dose distribution.Furthermore,we quantify the performance benefits of this new approach by directly comparing the reformatted dose distributions with 2D IC array detector mathematically interpolated measurements and original low-resolution measurements.The result shows that this new method is better than the mathematical interpolation and achieves gamma pass rates similar to those of the original low-resolution measurements.The reformatted dose distributions generally yield a confidence exceeding 95%.展开更多
A new detector array characterized by compact structure and large solid-angle coverage was designed for radioactive ion beam(RIB)experiments and measuring multi-particle correlations.A Monte Carlo simulation was perfo...A new detector array characterized by compact structure and large solid-angle coverage was designed for radioactive ion beam(RIB)experiments and measuring multi-particle correlations.A Monte Carlo simulation was performed to explore the effects of beam drifts in different directions and distances on the angular distribution of the Rutherford scattering,as measured by the detector array.The results indicate that when the beam drift distance is less than 2.0 mm,the symmetry of the detector array can maintain a count error of less than 5%.This confirms the property of the detector array for RIB experiments.Furthermore,the simulation was validated through the elastic scattering angular distributions of 6;7 Li measured by the detector array in 6;7Li t209 Bi experiments at different energies.展开更多
Total absorption gamma-ray spectroscopy(TAGS)is a powerful tool for measuring complexγ transitions,which has been effectively applied to the study of reactor decay heat.This paper presents the design of a new TAGS de...Total absorption gamma-ray spectroscopy(TAGS)is a powerful tool for measuring complexγ transitions,which has been effectively applied to the study of reactor decay heat.This paper presents the design of a new TAGS detector,the large-scale modular BGO detection array(LAMBDA),tailored for measuringβ-decay intensity distributions of fission products.The modular design allows the LAMBDA detectors to be assembled in various configurations.The final version of LAMBDA consists of 102 identical 60 mm×60 mm×120 mm BGO crystals and exhibits a high full-energy peak efficiency exceeding 80%at 0.5∼8 MeV based on a Monte Carlo simulation.Currently,approximately half of the LAMBDA modules have been manufactured.Tests usingγ-ray sources and nuclear reactions demonstrated favorable energy resolution,energy linearity,and efficiency uniformity across the modules.Forty-eight modules have been integrated into the prototype LAMBDA-I.The capability of LAMBDA-I inβ-delayedγ-decay experiments was evaluated by commissioning measurements using the ^(152)Eu source.展开更多
A particle detector array designed for light-charged particles, known as the CsI-bowl, was built for exit channel selection for in-beam γ-ray spectroscopy experiments. This device is composed of 64 CsI(Tl) detectors,...A particle detector array designed for light-charged particles, known as the CsI-bowl, was built for exit channel selection for in-beam γ-ray spectroscopy experiments. This device is composed of 64 CsI(Tl) detectors, organized in a structure reminiscent of a tea-bowl. High quantum efficiency photodiodes, characterized by their minimal mass, were employed to collect scintillation light. Its design, construction, particle identification resolution, and its effectiveness in relation to exit channel selection are described in this paper. In source tests, the optimal figure of merit for the identification of α-particles and γ-rays using the charge comparison method was found to be 3.3 and 12.1 for CsI detectors coupled to photodiodes and avalanche photodiodes, respectively. The CsI-bowl demonstrated effectiveness in identifying particles, specifically the emission of protons and α-particles in the58Ni(19F, xpyn) fusion–evaporation reaction, thereby enabling the selection of the desired exit channels.展开更多
The diode infrared focal plane array uses the silicon diodes as a sensitive device for infrared signal measurement. By the infrared radiation, the infrared focal plane can produces small voltage signals. For the tradi...The diode infrared focal plane array uses the silicon diodes as a sensitive device for infrared signal measurement. By the infrared radiation, the infrared focal plane can produces small voltage signals. For the traditional readout circuit structures are designed to process current signals, they cannot be applied to it. In this paper, a new readout circuit for the diode un-cooled infrared focal plane array is developed. The principle of detector array signal readout and small signal amplification is given in detail. The readout circuit is designed and simulated by using the Central Semiconductor Manufacturing Corporation (CSMC) 0.5 μm complementary metal-oxide-semiconductor transistor (CMOS) technology library. Cadence Spectre simulation results show that the scheme can be applied to the CMOS readout integrated circuit (ROIC) with a larger array, such as 320×240 size array.展开更多
The prompt fission neutron spectrum(PFNS)is a key nuclear data quantity that is of particular interest and plays a crucial role in understanding and modeling fission processes.An array comprising 48 liquid scintillati...The prompt fission neutron spectrum(PFNS)is a key nuclear data quantity that is of particular interest and plays a crucial role in understanding and modeling fission processes.An array comprising 48 liquid scintillation detectors and a parallelplate avalanche counter(PPAC)was developed at the China Institute of Atomic Energy(CIAE)to measure the PFNS of actinide nuclei.Efficiency and energy calibrations were performed for all the liquid scintillators,and their efficiencies were consistently found to be better than 5%.The time resolutions of the PPAC and liquid scintillators were measured to be 1.08 ns and 1.16 ns using~(252)Cf and~(207)Bi sources,respectively.The pulse shape discrimination of the liquid scintillator was utilized to identify neutron andγsignals on an event-by-event basis,and the figure of merit was deduced as 1.12 at a 200 ke Vee threshold.The contribution to the PFNS from multiple scattered neutrons was evaluated via Geant4 simulations,and those originating from the environment were found to be comparable to the crosstalk between the detectors.The neutron efficiency of the entire detection array was calibrated using a~(252)Cf spontaneous fission source and was demonstrated to be consistent with the Geant4 simulation results,which verified the reliability of the detection array.展开更多
Multi-element array photoelectric detector is the core devices to form a photoelectric detection target with a large field of view.This photoelectric detection target brings about the problem of uneven detection sensi...Multi-element array photoelectric detector is the core devices to form a photoelectric detection target with a large field of view.This photoelectric detection target brings about the problem of uneven detection sensitivity distribution in the detection screen.To improve the uneven detection sensitivity of this photoelectric detection target,this paper analyzes the distribution law of the uneven detection sensitivity of the photoelectric detection target using the multi-element array photoelectric detector,dissects the main factors affecting the detection sensitivity according to the photoelectric detection principle,establishes the calculation model of detection sensitivity of the photoelectric detection target in the different detection areas and proposes a method to improve the detection sensitivity by compensating the gain of each unit photoelectric detector.The analysis of simulation and experimental results show that the proposed method of photoelectric detection target can effectively improve the output signal amplitude of the projectile under the certain detection distance,in particular,the output signal amplitude of the projectile is significantly increased when the projectile passes through the detection blind area.The experimental results are consistent with the simulation results,which verify the effectiveness of the proposed improvement method.展开更多
基金supported by the National Natural Science Foundation of China(Nos.12175280 and 12250610193)the National Key R&D Program of China(No.2016YFA0400500)+1 种基金the support of the CAS“Light of West China”Programthe support of the Natural Science Foundation of Gansu(No.23JRRA676)。
文摘A charged particle array named MATE-PA,which serves as an auxiliary detector system for a Multi-purpose Active-target Time projection chamber used in nuclear astrophysical and exotic beam Experiments(MATE),was constructed.The array comprised of 20 single-sided strip-silicon detectors covering approximately 10%of the solid angle.The detectors facilitated the detection of reaction-induced charged particles that penetrate the active volume of the MATE.The performance of MATE-PA has been experimentally studied using an alpha source and a 36-MeV 14 N beam injected into the MATE chamber on the radioactive ion beam line in Lanzhou(RIBLL).The chamber was filled with a gas mixture of 95%4 He and 5%CO_(2) at a pressure of 500 mbar.The results indicated good separation of light-charged particles using the forward double-layer silicon detectors of MATE-PA.The energy resolution of the Si detectors was deduced to be approximately 1%(σ)for an energy loss of approximately 10 MeV caused by theαparticles.The inclusion of MATE-PA improves particle identification and increases the dynamic range of the kinetic energy of charged particles,particularly that of theαparticles,up to approximately 15 MeV.
文摘The spatial resolution of a commercial two-dimensional(2D)ionization chamber(IC)array is limited by the size of the individual detector and the center-to-center distance between sensors.For dose distributions with areas of steep dose gradients,inter-detector dose values are derived by the interpolation of nearby detector readings in the conventional mathematical interpolation of 2D IC array measurements.This may introduce significant errors,particularly in proton spot scanning radiotherapy.In this study,by combining logfile-based reconstructed dose values and detector measurements with the Laplacian pyramid image blending method,a novel method is proposed to obtain a reformatted dose distribution that provides an improved estimation of the delivered dose distribution with high spatial resolution.Meanwhile,the similarity between the measured original data and the downsampled logfilebased reconstructed dose is regarded as the confidence of the reformatted dose distribution.Furthermore,we quantify the performance benefits of this new approach by directly comparing the reformatted dose distributions with 2D IC array detector mathematically interpolated measurements and original low-resolution measurements.The result shows that this new method is better than the mathematical interpolation and achieves gamma pass rates similar to those of the original low-resolution measurements.The reformatted dose distributions generally yield a confidence exceeding 95%.
基金the National Natural Science Foundation of China(Nos.11635015,U1832130,and 11975040)the State Key Laboratory of Software Development Environment(SKLSDE-2020ZX-16)+1 种基金the Continuous Basic Scientific Research Project(No.WDJC-2019-13)the Leading Innovation Project(Nos.LC192209000701 and LC202309000201).
文摘A new detector array characterized by compact structure and large solid-angle coverage was designed for radioactive ion beam(RIB)experiments and measuring multi-particle correlations.A Monte Carlo simulation was performed to explore the effects of beam drifts in different directions and distances on the angular distribution of the Rutherford scattering,as measured by the detector array.The results indicate that when the beam drift distance is less than 2.0 mm,the symmetry of the detector array can maintain a count error of less than 5%.This confirms the property of the detector array for RIB experiments.Furthermore,the simulation was validated through the elastic scattering angular distributions of 6;7 Li measured by the detector array in 6;7Li t209 Bi experiments at different energies.
基金supported by the National Key R&D Program of China (Nos. 2022YFA1603300, 2018YFA0404401, 2023YFA1606701, and 2022YFA1602301)National Natural Science Foundation of China (Nos. U1867211, 12275026, and 12222514)the CAS Light of West China Program (No. 2020-82)
文摘Total absorption gamma-ray spectroscopy(TAGS)is a powerful tool for measuring complexγ transitions,which has been effectively applied to the study of reactor decay heat.This paper presents the design of a new TAGS detector,the large-scale modular BGO detection array(LAMBDA),tailored for measuringβ-decay intensity distributions of fission products.The modular design allows the LAMBDA detectors to be assembled in various configurations.The final version of LAMBDA consists of 102 identical 60 mm×60 mm×120 mm BGO crystals and exhibits a high full-energy peak efficiency exceeding 80%at 0.5∼8 MeV based on a Monte Carlo simulation.Currently,approximately half of the LAMBDA modules have been manufactured.Tests usingγ-ray sources and nuclear reactions demonstrated favorable energy resolution,energy linearity,and efficiency uniformity across the modules.Forty-eight modules have been integrated into the prototype LAMBDA-I.The capability of LAMBDA-I inβ-delayedγ-decay experiments was evaluated by commissioning measurements using the ^(152)Eu source.
基金supported by the Major program of Natural Science Foundation of Shandong Province(No.ZR2020ZD30)the National Natural Science Foundation of China(Nos.11775133,U2167202,U1432119).
文摘A particle detector array designed for light-charged particles, known as the CsI-bowl, was built for exit channel selection for in-beam γ-ray spectroscopy experiments. This device is composed of 64 CsI(Tl) detectors, organized in a structure reminiscent of a tea-bowl. High quantum efficiency photodiodes, characterized by their minimal mass, were employed to collect scintillation light. Its design, construction, particle identification resolution, and its effectiveness in relation to exit channel selection are described in this paper. In source tests, the optimal figure of merit for the identification of α-particles and γ-rays using the charge comparison method was found to be 3.3 and 12.1 for CsI detectors coupled to photodiodes and avalanche photodiodes, respectively. The CsI-bowl demonstrated effectiveness in identifying particles, specifically the emission of protons and α-particles in the58Ni(19F, xpyn) fusion–evaporation reaction, thereby enabling the selection of the desired exit channels.
基金supported by the Fundamental Research Funds for the Central Universities under Grant No. 2009JBM001
文摘The diode infrared focal plane array uses the silicon diodes as a sensitive device for infrared signal measurement. By the infrared radiation, the infrared focal plane can produces small voltage signals. For the traditional readout circuit structures are designed to process current signals, they cannot be applied to it. In this paper, a new readout circuit for the diode un-cooled infrared focal plane array is developed. The principle of detector array signal readout and small signal amplification is given in detail. The readout circuit is designed and simulated by using the Central Semiconductor Manufacturing Corporation (CSMC) 0.5 μm complementary metal-oxide-semiconductor transistor (CMOS) technology library. Cadence Spectre simulation results show that the scheme can be applied to the CMOS readout integrated circuit (ROIC) with a larger array, such as 320×240 size array.
基金supported by Continuous-Support Basic Scientific Research Project(No.BJ010261223282)the National Natural Science Foundation of China(Nos.U2167201,11975318)+2 种基金the State Key Laboratory of Nuclear Physics and TechnologyPeking University(No.NPT2023KFY01)the Research and Development Project of China National Nuclear Corporation。
文摘The prompt fission neutron spectrum(PFNS)is a key nuclear data quantity that is of particular interest and plays a crucial role in understanding and modeling fission processes.An array comprising 48 liquid scintillation detectors and a parallelplate avalanche counter(PPAC)was developed at the China Institute of Atomic Energy(CIAE)to measure the PFNS of actinide nuclei.Efficiency and energy calibrations were performed for all the liquid scintillators,and their efficiencies were consistently found to be better than 5%.The time resolutions of the PPAC and liquid scintillators were measured to be 1.08 ns and 1.16 ns using~(252)Cf and~(207)Bi sources,respectively.The pulse shape discrimination of the liquid scintillator was utilized to identify neutron andγsignals on an event-by-event basis,and the figure of merit was deduced as 1.12 at a 200 ke Vee threshold.The contribution to the PFNS from multiple scattered neutrons was evaluated via Geant4 simulations,and those originating from the environment were found to be comparable to the crosstalk between the detectors.The neutron efficiency of the entire detection array was calibrated using a~(252)Cf spontaneous fission source and was demonstrated to be consistent with the Geant4 simulation results,which verified the reliability of the detection array.
基金supported by Project of the Xi’an Science and Technology Innovation talent service enterprise project(No.2020KJRC0041)National Natural Science Foundation of China(No.62073256)Key Programs of Shaanxi Science and Technology Department(No.2020GY-125)。
文摘Multi-element array photoelectric detector is the core devices to form a photoelectric detection target with a large field of view.This photoelectric detection target brings about the problem of uneven detection sensitivity distribution in the detection screen.To improve the uneven detection sensitivity of this photoelectric detection target,this paper analyzes the distribution law of the uneven detection sensitivity of the photoelectric detection target using the multi-element array photoelectric detector,dissects the main factors affecting the detection sensitivity according to the photoelectric detection principle,establishes the calculation model of detection sensitivity of the photoelectric detection target in the different detection areas and proposes a method to improve the detection sensitivity by compensating the gain of each unit photoelectric detector.The analysis of simulation and experimental results show that the proposed method of photoelectric detection target can effectively improve the output signal amplitude of the projectile under the certain detection distance,in particular,the output signal amplitude of the projectile is significantly increased when the projectile passes through the detection blind area.The experimental results are consistent with the simulation results,which verify the effectiveness of the proposed improvement method.