Currently,three types of superconducting quadrupole magnets are used in particle accelerators:cos 2θ,CCT,and serpentine.However,all three coil configurations have complex spatial geometries,which make magnet manufact...Currently,three types of superconducting quadrupole magnets are used in particle accelerators:cos 2θ,CCT,and serpentine.However,all three coil configurations have complex spatial geometries,which make magnet manufacturing and strain-sensitive superconductor applications difficult.Compared with the three existing quadrupole coils,the racetrack quadrupole coil has a simple shape and manufacturing process,but there have been few theoretical studies.In this paper,the two-dimensional and three-dimensional analytical expressions for the magnetic field in coil-dominated racetrack superconducting quadrupole magnets are presented.The analytical expressions of the field harmonics and gradient are fully resolved and depend only on the geometric parameters of the coil and current density.Then,a genetic algorithm is applied to obtain a solution for the coil geometry parameters with field harmonics on the order of 10^(-4).Finally,considering the practical engineering needs of the accelerator interaction region,electromagnetic design examples of racetrack quadrupole magnets with high gradients,large apertures,and small apertures are described,and the application prospects of racetrack quadrupole coils are analyzed.展开更多
In this paper, an approach to the design of shielded radio-frequency (RF) phased-array coils for magnetic resonance imaging (MRI) is proposed. The target field method is used to find current densities distributed ...In this paper, an approach to the design of shielded radio-frequency (RF) phased-array coils for magnetic resonance imaging (MRI) is proposed. The target field method is used to find current densities distributed on primary and shield coils. The stream function technique is used to discretize current densities and to obtain the winding patterns of the coils. The corresponding highly ill-conditioned integral equation is solved by the Tikhonov regularization with a penalty function related to the minimum curvature. To balance the simplicity and smoothness with the homogeneity of the magnetic field of the coll's winding pattern, the selection of a penalty factor is discussed in detail.展开更多
For a superconducting magnet of magnetic resonance imaging (MRI), the novel approach presented in this paper allows the design of cylindrical gradient and shim coils of finite length. The method is based on identifi...For a superconducting magnet of magnetic resonance imaging (MRI), the novel approach presented in this paper allows the design of cylindrical gradient and shim coils of finite length. The method is based on identification of the weighting of harmonic components in the current distribution that will generate a magnetic field whose z-component follows a chosen spherical harmonic function. Mathematical expressions which relate the harmonic terms in the cylin- drical current distribution to spherical harmonic terms in the field expansion are established. Thus a simple matrix inversion approach can be used to design a shim coil of any order pure harmonic. The expressions providing a spherical harmonic decomposition of the field components produced by a particular cylindrical current distribution are novel. A stream function was applied to obtain the discrete wire distribution on the cylindrical-surface. This method does not require the setting of the target-field points. The discussion referring to matrix equations in terms of condition numbers proves that this novel approach has no ill-conditioned problems. The results also indicate that it can be used to design cylindrical-surface shim coils of finite length that will generate a field variation which follows a particular spherical harmonic over a reasonably large-sized volume.展开更多
The electromagnetic concentrative coils are indispensable in the functional magnetic stimulation and have potential applications in nondestructive testing. In this paper, we propose a figure-8-shaped coil being compos...The electromagnetic concentrative coils are indispensable in the functional magnetic stimulation and have potential applications in nondestructive testing. In this paper, we propose a figure-8-shaped coil being composed of two arbitrary oblique elliptical coils, which can change the electromagnetic concentrative region and the magnitude of eddy current density by changing the elliptical shape and/or spread angle between two elliptical coils. Pulsed current is usually the excitation source in the functional magnetic stimulation, so in this paper we derive the analytical solutions of transient pulsed eddy current field in the time domain due to the elliptical concentrative coil placed in an arbitrary position over a half-infinite plane conductor by making use of the scale-transformation, the Laplace transform and the Fourier transform are used in our derivation. Calculation results of field distributions produced by the figure-8-shaped elliptical coil show some behaviours as follows: 1) the eddy currents are focused on the conductor under the geometric symmetric centre of figure-8-shaped coil; 2) the greater the scale factor of ellipse is, the higher the eddy current density is and the wider the concentrative area of eddy current along y axis is; 3) the maximum magnitude of eddy current density increases with the increase of spread angle. When spread angle is 180°, there are two additional reverse concentrative areas on both sides of x axis.展开更多
ITER edge localized mode (ELM) coils are important components of the in-vessel coils (IVCs) and they are designed for mitigating or suppressing ELMs. The coils located on the vacuum vessel (VV) and behind the bl...ITER edge localized mode (ELM) coils are important components of the in-vessel coils (IVCs) and they are designed for mitigating or suppressing ELMs. The coils located on the vacuum vessel (VV) and behind the blanket are subjected to high temperature due to the nuclear heat from the plasma, the Ohmic heat induced by the working current and the thermal radiation from the environment. The water serves as coolant to remove the heat deposited into the coils. Based on the results of nuclear analysis, the thermal-hydraulic analysis is performed for the preliminary design of upper ELM coils using a rapid evaluation method based on 1D treatment. The thermal-hydraulic design and operating parameters including the water flow velocity are optimized. It is found that the rapid evaluation method based on 1D treatment is feasible and reliable. According to the rapid analysis method, the thermal hydraulic parameters of two water flow schemes are computed and proved similar to each other, providing an effective basis for the coil design. Finally, considering jointly the pressure drop requirement and the cooling capacity, the flow velocity is optimized to 5 m/s.展开更多
For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating ...For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating a SQUID magnetometer system using three orthogonal Helmholtz coils.The Tesla/volt coefficient is regarded as the magnitude of a vector pointing to the normal direction of the pickup coil.By applying magnetic fields through a three-dimensional Helmholtz coil,the Tesla/volt coefficient can be directly calculated from magnetometer responses to the three orthogonally applied magnetic fields.Calibration with alternating current(AC) field is normally used for better signal-to-noise ratio in noisy urban environments and the results are compared with the direct current(DC) calibration to avoid possible effects due to eddy current.In our experiment,a calibration relative error of about 6.89 × 10-4is obtained,and the error is mainly caused by the non-orthogonality of three axes of the Helmholtz coils.The method does not need precise alignment of the magnetometer inside the Helmholtz coil.It can be used for the multichannel magnetometer system calibration effectively and accurately.展开更多
A driver-pickup probe possesses better sensitivity and flexibility due to individual optimization of a coil.It is fre-quently observed in an eddy current(EC)array probe.In this work,a tilted non-coaxial driver-pickup ...A driver-pickup probe possesses better sensitivity and flexibility due to individual optimization of a coil.It is fre-quently observed in an eddy current(EC)array probe.In this work,a tilted non-coaxial driver-pickup probe above a multilayered conducting plate is analytically modeled with spatial transformation for eddy current nondestructive evalua-tion.Basically,the core of the formulation is to obtain the projection of magnetic vector potential(MVP)from the driver coil onto the vector along the tilted pickup coil,which is divided into two key steps.The first step is to make a projection of MVP along the pickup coil onto a horizontal plane,and the second one is to build the relationship between the pr,ojected MVP and the MVP along the driver coil.Afterwards,an analytical model for the case of a layered plate is established with the reflection and transmission theory of electromagnetic fields.The calculated values from the resulting model indicate good agreement with those from the finite element model(FEM)and experiments,which validates the developed analytical model.展开更多
The HT-7U tokamak is a magnetically-confined full superconducting fusion device, consisting of superconducting toroidal field (TF) coils and superconducting poloidal field (PF) coils. These coils are wound with cable-...The HT-7U tokamak is a magnetically-confined full superconducting fusion device, consisting of superconducting toroidal field (TF) coils and superconducting poloidal field (PF) coils. These coils are wound with cable-in-conductor (CICC) which is based on UNK NbTi wires made in Russian '. A single D-shaped toroidal field magnet coil will be tested for large and expensive magnets systems before assembling them in the toroidal configuration. This paper describes the layout of the instrumentation for a superconducting test facility based on the results of a finite element modeling of the single coil of toroidal magnetic field (TF) coils in HT-7U tokamak device. At the same time, the design of coil support structure in the test facility is particularly discussed in some detail.展开更多
Magnetic coils for specific requirements are widely used in modern quantum physics. In this study, a general analytical method of designing the shielded coils for generating an arbitrary axial magnetic field is propos...Magnetic coils for specific requirements are widely used in modern quantum physics. In this study, a general analytical method of designing the shielded coils for generating an arbitrary axial magnetic field is proposed. The theoretical formula for an axial magnetic field generated by a single shielded coil is obtained and used to construct specific coils. The structural parameters of these coils are determined by fitting the theoretical formula with their specific requirements. The feasibility of this method is proved by realizing four concrete kinds of coils: uniform magnetic field generating coils, gradient magnetic field generating coils, asymmetrical uniform magnetic field generating coils, and parabolic magnetic field generating coils. The correctness of these theoretical results is demonstrated by both the finite element simulations and the relevant experimental results. Furthermore, the application of this method is of great significance for developing the quantum physics and quantum devices in future.展开更多
This paper is devoted to predict AC loss of cable in conduit conductor (CICC) which is of importance in the design of conductors. The consideration for the conductor's design and main parameters for the magnets are...This paper is devoted to predict AC loss of cable in conduit conductor (CICC) which is of importance in the design of conductors. The consideration for the conductor's design and main parameters for the magnets are introduced. In order to attain a good accuracy in the calculation of AC losses, the field distribution within superconducting outsert should be considered. Calculation of the AC losses, including hysteresis losses and coupling losses, is conducted. An emphasis is put on the hysteresis loss during the ramp up of the current to the operational current (15.3 kA) and the coupling loss of the conductor in a power-down condition for insert. The results are obtained to be 74.9 kJ and 950 J for 40 T hybrid magnets, respectively. Based on the calculation, a brief analysis of losses effect on the conductor design and the operation of magnet is given for the purpose that the capacity of the cryogenertor can be evaluated and the stability regime can be improved in our future work on the hybrid magnets.展开更多
High vacuum is required for Vacuum Pressure Impregnation (VPI) process of large coils used in cryogenic. The defects such as dry spots and over rich resins should be minimized in large superconducting coils used. Both...High vacuum is required for Vacuum Pressure Impregnation (VPI) process of large coils used in cryogenic. The defects such as dry spots and over rich resins should be minimized in large superconducting coils used. Both sealing problems associated with the mold and over rich resin problems are eliminated by using vacuum bag mold method with which we can simplify the design of vacuum mold.展开更多
A set of in-vessel resonant magnetic perturbation (RMP) coils for MHD instability suppression is proposed for the design of a HL-2M tokamak. Each coil is to be fed with a current of up to 5 kA, operated in a frequen...A set of in-vessel resonant magnetic perturbation (RMP) coils for MHD instability suppression is proposed for the design of a HL-2M tokamak. Each coil is to be fed with a current of up to 5 kA, operated in a frequency range from DC to about I kHz. Stainless steel (SS) jacketed mineral insulated cables are proposed for the conductor of the coils. In-vessel coils must withstand large electromagnetic (EM) and thermal loads. The support, insulation and vacuum sealing in a very limited space are crucial issues for engineering design. Hence finite element calculations are performed to verify the design, optimize the support by minimizing stress caused by EM forces on the coil conductors and work out the temperature rise occurring on the coil in different working conditions, the corresponding thermal stress caused by the thermal expansion of materials is evaluated to be allowable. The techniques to develop the in-vessel RMP coils, such as support, insulation and cooling, are discussed.展开更多
A set of four in-vessel saddle coils was designed to generate a helical field on the J- TEXT tokamak to study the influences of the external perturbation field on plasma. The coils are fed with alternating current up ...A set of four in-vessel saddle coils was designed to generate a helical field on the J- TEXT tokamak to study the influences of the external perturbation field on plasma. The coils are fed with alternating current up to 10 kA at frequency up to 10 kHz. Due to the special structure, complex thermal environment and limited space in the vacuum chamber, Jt is very important to make sure that the coils will not be damaged when undergoing the huge electromagnetic forces in the strong toroidal field, and that their temperatures don't rise too much and destroy the in- sulation. A 3D finite element model is developed in this paper using the ANSYS code, stresses are analyzed to find the worst condition, and a mounting method is then established. The results of the stress and modal analyses show that the mounting method meets the strength requirements. Finally, a thermal analysis is performed to study the cooling process and the temperature distribution of the coils.展开更多
The relatively fragile low-temperature stability of cryogen-free superconducting magnetic resonance imaging(MRI)magnets requires the careful management of exogenous heat sources.A strongly shielded gradient magnetic f...The relatively fragile low-temperature stability of cryogen-free superconducting magnetic resonance imaging(MRI)magnets requires the careful management of exogenous heat sources.A strongly shielded gradient magnetic field is important for the optimal operation of cryogen-free MRI systems.In this study,we present an enhanced shielding method incorporating a regionalized stray field constraining strategy.By optimizing the constraint parameters,we could develop engineering-feasible gradient coil schemes without increasing system complexity but with the stray field intensity reduced by half.In real measurement in an integrated MRI system,the developed gradient assembly demonstrated good performance and supported to output images of excellent quality.Our findings suggested that the proposed method could potentially form a useful design paradigm for cryogen-free MRI magnets.展开更多
Polygonal coil systems are designed for increasing and more kinds of sensors and electromagnetic systems.This paper presents a method for calculating mutual inductance between polygonal coils including irregular polyg...Polygonal coil systems are designed for increasing and more kinds of sensors and electromagnetic systems.This paper presents a method for calculating mutual inductance between polygonal coils including irregular polygons.Based on the Biot-Savart law,the method calculates mutual inductance by dividing a polygonal coil into finite wires,and expresses the magnetic induction intensity generated by the excitation coil as a function of the spatial position of each vertex of the coil.The calculation method of the feasible region of the objective function is updated and the calculation process is simplified,so the calculation accuracy is improved.For octagon coils arbitrarily positioned in space,the accuracy of the algorithm is verified by the simulation and experiment.展开更多
Objective. To compare the embolization effects of intracranial aneurysms with mechanical detachable spirals (MDS) and with Guglielmi detachable coils (GDC).Methods. One hundred and twenty cases with 125 intracranial a...Objective. To compare the embolization effects of intracranial aneurysms with mechanical detachable spirals (MDS) and with Guglielmi detachable coils (GDC).Methods. One hundred and twenty cases with 125 intracranial aneurysms were embolized in Beijing Hospital from March 1995 to July 1999. Sixty - six aneurysms in 64 cases were embolized with MDS, 51 in 48 with GDC, and 8 in 8 with both MDS and GDC. Clinical data including sex, age, subarachnoid hemorrhage (SAH), Hunt & Hess grading, diameter and neck width of aneurysms, number and length of coils used per aneurysm, occlusive ratio, and complications were compared between MDS and GDC groups.Results. MDS and GDC groups were comparable (t-test or x2 -test, all P value > 0. 10) in terms of age, sex, diameter of aneurysms [ (8. 46 ± 3. 42) mm vs. (7. 38 ± 3. 45) mm], neck width [ (3. 49 ± 1. 50) mm vs. (3. 26 ± 1. 52) mm], coils number[ (4. 65 ± 3. 01) vs. (4. 24 ± 2. 65) ] and their length[ (460. 2 ± 398. 5) mm vs. (422. 9 ±387. 1) mm] used per aneurysm, occlusive ratio in aneurysms embolized ≥80% [ (95. 00% ± 6. 32% ) vs. (94. 19% ± 7. 63% ) ], mortality and permanent complications (7. 8% vs. 4. 2% ).Conclusions. MDS and GDC are all materials for embolization of intracranial aneurysms. MDS is less expensive, but more difficult to control and of propensity to complications while GDC is more compliant, easier to be used, safer, and have many alternative types for use as well as more extensive indications.展开更多
Electrolytic detachable coils (EDC) have been the main embolic materi als for intracranial aneurysms. Liquid aneurysmal embolic materials represented by cellulose acetate polymer (CAP) are still in controversy. In thi...Electrolytic detachable coils (EDC) have been the main embolic materi als for intracranial aneurysms. Liquid aneurysmal embolic materials represented by cellulose acetate polymer (CAP) are still in controversy. In this research, t he embolization results and pathological reactions after embolization of canine aneurysmal models with EDC or CAP were observed and compared. Methods. The canine aneurysmal models constructed by anastomosis of venous pouch es were randomly grouped. The aneurysms were respectively occluded with CAP and electrolytic detachable coils that was named by Wu electrolytic detachable coil (WEDC) and made by us. Angiogram follow ups were performed at 24 hour, 2 week , and 2 month after embolization. The occluded aneurysms were dissected in each stage for light microscopic, electron microscopic, and histochemical research. Results. The effect of embolization was significantly better with WEDC than that with CAP . Post embolized complications such as aneurysm rupture and stenosis of parent arteries could only be found in CAP group. Pathol ogical research showed that CAP mass could packed the aneurysms more densely tha n coils. Acute chemical damage of aneurysmal wall and inflammatory cell infiltra tion was prominently found in early stage after CAP embolization. Organization of thrombus inside aneurysms and formation of endothelial tissue over the orific es of aneurysmal necks could be found in both groups 2 months after embolization . But parts of coils might be exposed outside endothelial layer. Conclusions. EDC are still the most safe, efficient, and reliable instruments to embolize aneurysm. CAP should be improved further to solve the problem of stron g chemical corrosion and difficulty in control before it is widely used.展开更多
A topology optimization method based on the solid isotropic material with penalization interpolation scheme is utilized for designing gradient coils for use in magnetic resonance microscopy.Unlike the popular stream f...A topology optimization method based on the solid isotropic material with penalization interpolation scheme is utilized for designing gradient coils for use in magnetic resonance microscopy.Unlike the popular stream function method,the proposed method has design variables that are the distribution of conductive material.A voltage-driven transverse gradient coil is proposed to be used as micro-scale magnetic resonance imaging(MRI)gradient coils,thus avoiding introducing a coil-winding pattern and simplifying the coil configuration.The proposed method avoids post-processing errors that occur when the continuous current density is approximated by discrete wires in the stream function approach.The feasibility and accuracy of the method are verified through designing the z-gradient and y-gradient coils on a cylindrical surface.Numerical design results show that the proposed method can provide a new coil layout in a compact design space.展开更多
The resonant magnetic perturbation(RMP)system is a powerful auxiliary system on tokamaks.On the J-TEXT tokamak,a set of new in-vessel coils is designed to enhance the amplitude of the RMP.The new coils are designed to...The resonant magnetic perturbation(RMP)system is a powerful auxiliary system on tokamaks.On the J-TEXT tokamak,a set of new in-vessel coils is designed to enhance the amplitude of the RMP.The new coils are designed to be two-turn saddle coils.These two-turn saddle coils have been optimized in terms of their structure,support,and protection components to overcome the limitations of the narrow in-vessel space,resulting in a compact coil module that can be accommodated in the vessel.To verify the feasibility of this design,an electromagnetic simulation is performed to investigate the electrical parameters and the generated field of the coils.A multi-field coupled simulation is performed to investigate the capacity of heat dissipation.As a result of these efforts,the new RMP coils have been successfully installed on the J-TEXT tokamak.It has significantly enhanced the RMP amplitude and been widely applied in experiments.展开更多
Laser-induced breakdown spectroscopy(LIBS)is a powerful technique for elemental analysis,offering rapid analysis,minimal sample preparation,wide elemental coverage,and portability.To enhance the detection sensitivity ...Laser-induced breakdown spectroscopy(LIBS)is a powerful technique for elemental analysis,offering rapid analysis,minimal sample preparation,wide elemental coverage,and portability.To enhance the detection sensitivity of LIBS,increasing the spectral emission intensity is crucial.This paper explores the use of Tesla coil(TC)discharge as an alternative to spark discharge in silicon LIBS.The study examines the influence of TC discharge on both time-integrated and timeresolved spectra,with and without TC discharge;the corresponding electron temperature and density are obtained.The results show that TC discharge significantly amplifies the spectral intensity,improving signal sensitivity in LIBS analysis.Specifically,in the laser energy range from 7.4 to 24.0 mJ,TC discharge increased the average spectral line intensities of Si(II)385.60 nm and Si(I)390.55 nm by factors of 8.4 and 5.1,respectively.Additionally,the average electron temperature and density were enhanced by approximately 3.2%and 4.2%,respectively,under TC discharge.The advantages of TC discharge include higher energy deposition,extended discharge duration,reduced electrode erosion,and enhanced safety.This research contributes to advancing LIBS technology and expanding its applications in various fields.展开更多
基金supported in part by the National Key Research and Development Program of China(No.2022YFA1603402)in part by the National Natural Science Foundation of China(No.11875272)。
文摘Currently,three types of superconducting quadrupole magnets are used in particle accelerators:cos 2θ,CCT,and serpentine.However,all three coil configurations have complex spatial geometries,which make magnet manufacturing and strain-sensitive superconductor applications difficult.Compared with the three existing quadrupole coils,the racetrack quadrupole coil has a simple shape and manufacturing process,but there have been few theoretical studies.In this paper,the two-dimensional and three-dimensional analytical expressions for the magnetic field in coil-dominated racetrack superconducting quadrupole magnets are presented.The analytical expressions of the field harmonics and gradient are fully resolved and depend only on the geometric parameters of the coil and current density.Then,a genetic algorithm is applied to obtain a solution for the coil geometry parameters with field harmonics on the order of 10^(-4).Finally,considering the practical engineering needs of the accelerator interaction region,electromagnetic design examples of racetrack quadrupole magnets with high gradients,large apertures,and small apertures are described,and the application prospects of racetrack quadrupole coils are analyzed.
基金Project supported by the National Nature Science Foundation of China (Grant No. 30900332)Grant of General Administration of Quality Supervision Inspection and Quarantine of China (Grant No. 201210079)+1 种基金the Program for Science and Technology Department of Zhejiang Province, China (Grant Nos. 2010C14010 and 2010C33172)the Natural Science Foundation of Zhejiang Province, China (Grant No. Y2090966)
文摘In this paper, an approach to the design of shielded radio-frequency (RF) phased-array coils for magnetic resonance imaging (MRI) is proposed. The target field method is used to find current densities distributed on primary and shield coils. The stream function technique is used to discretize current densities and to obtain the winding patterns of the coils. The corresponding highly ill-conditioned integral equation is solved by the Tikhonov regularization with a penalty function related to the minimum curvature. To balance the simplicity and smoothness with the homogeneity of the magnetic field of the coll's winding pattern, the selection of a penalty factor is discussed in detail.
基金Project supported by the National Natural Science Foundation of China (Grant No. 60871001)
文摘For a superconducting magnet of magnetic resonance imaging (MRI), the novel approach presented in this paper allows the design of cylindrical gradient and shim coils of finite length. The method is based on identification of the weighting of harmonic components in the current distribution that will generate a magnetic field whose z-component follows a chosen spherical harmonic function. Mathematical expressions which relate the harmonic terms in the cylin- drical current distribution to spherical harmonic terms in the field expansion are established. Thus a simple matrix inversion approach can be used to design a shim coil of any order pure harmonic. The expressions providing a spherical harmonic decomposition of the field components produced by a particular cylindrical current distribution are novel. A stream function was applied to obtain the discrete wire distribution on the cylindrical-surface. This method does not require the setting of the target-field points. The discussion referring to matrix equations in terms of condition numbers proves that this novel approach has no ill-conditioned problems. The results also indicate that it can be used to design cylindrical-surface shim coils of finite length that will generate a field variation which follows a particular spherical harmonic over a reasonably large-sized volume.
基金Project supported by the National Natural Science Foundation of China (Grant No. 50807001)
文摘The electromagnetic concentrative coils are indispensable in the functional magnetic stimulation and have potential applications in nondestructive testing. In this paper, we propose a figure-8-shaped coil being composed of two arbitrary oblique elliptical coils, which can change the electromagnetic concentrative region and the magnitude of eddy current density by changing the elliptical shape and/or spread angle between two elliptical coils. Pulsed current is usually the excitation source in the functional magnetic stimulation, so in this paper we derive the analytical solutions of transient pulsed eddy current field in the time domain due to the elliptical concentrative coil placed in an arbitrary position over a half-infinite plane conductor by making use of the scale-transformation, the Laplace transform and the Fourier transform are used in our derivation. Calculation results of field distributions produced by the figure-8-shaped elliptical coil show some behaviours as follows: 1) the eddy currents are focused on the conductor under the geometric symmetric centre of figure-8-shaped coil; 2) the greater the scale factor of ellipse is, the higher the eddy current density is and the wider the concentrative area of eddy current along y axis is; 3) the maximum magnitude of eddy current density increases with the increase of spread angle. When spread angle is 180°, there are two additional reverse concentrative areas on both sides of x axis.
文摘ITER edge localized mode (ELM) coils are important components of the in-vessel coils (IVCs) and they are designed for mitigating or suppressing ELMs. The coils located on the vacuum vessel (VV) and behind the blanket are subjected to high temperature due to the nuclear heat from the plasma, the Ohmic heat induced by the working current and the thermal radiation from the environment. The water serves as coolant to remove the heat deposited into the coils. Based on the results of nuclear analysis, the thermal-hydraulic analysis is performed for the preliminary design of upper ELM coils using a rapid evaluation method based on 1D treatment. The thermal-hydraulic design and operating parameters including the water flow velocity are optimized. It is found that the rapid evaluation method based on 1D treatment is feasible and reliable. According to the rapid analysis method, the thermal hydraulic parameters of two water flow schemes are computed and proved similar to each other, providing an effective basis for the coil design. Finally, considering jointly the pressure drop requirement and the cooling capacity, the flow velocity is optimized to 5 m/s.
基金Project supported by the“Strategic Priority Research Program(B)”of the Chinese Academy of Sciences(Grant No.XDB04020200)the Shanghai Municipal Science and Technology Commission Project,China(Grant No.15DZ1940902)
文摘For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating a SQUID magnetometer system using three orthogonal Helmholtz coils.The Tesla/volt coefficient is regarded as the magnitude of a vector pointing to the normal direction of the pickup coil.By applying magnetic fields through a three-dimensional Helmholtz coil,the Tesla/volt coefficient can be directly calculated from magnetometer responses to the three orthogonally applied magnetic fields.Calibration with alternating current(AC) field is normally used for better signal-to-noise ratio in noisy urban environments and the results are compared with the direct current(DC) calibration to avoid possible effects due to eddy current.In our experiment,a calibration relative error of about 6.89 × 10-4is obtained,and the error is mainly caused by the non-orthogonality of three axes of the Helmholtz coils.The method does not need precise alignment of the magnetometer inside the Helmholtz coil.It can be used for the multichannel magnetometer system calibration effectively and accurately.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.61701500,51677187,and 51465024)
文摘A driver-pickup probe possesses better sensitivity and flexibility due to individual optimization of a coil.It is fre-quently observed in an eddy current(EC)array probe.In this work,a tilted non-coaxial driver-pickup probe above a multilayered conducting plate is analytically modeled with spatial transformation for eddy current nondestructive evalua-tion.Basically,the core of the formulation is to obtain the projection of magnetic vector potential(MVP)from the driver coil onto the vector along the tilted pickup coil,which is divided into two key steps.The first step is to make a projection of MVP along the pickup coil onto a horizontal plane,and the second one is to build the relationship between the pr,ojected MVP and the MVP along the driver coil.Afterwards,an analytical model for the case of a layered plate is established with the reflection and transmission theory of electromagnetic fields.The calculated values from the resulting model indicate good agreement with those from the finite element model(FEM)and experiments,which validates the developed analytical model.
基金The project supported by the National Meg-Science Enineering Project of Chinese Government
文摘The HT-7U tokamak is a magnetically-confined full superconducting fusion device, consisting of superconducting toroidal field (TF) coils and superconducting poloidal field (PF) coils. These coils are wound with cable-in-conductor (CICC) which is based on UNK NbTi wires made in Russian '. A single D-shaped toroidal field magnet coil will be tested for large and expensive magnets systems before assembling them in the toroidal configuration. This paper describes the layout of the instrumentation for a superconducting test facility based on the results of a finite element modeling of the single coil of toroidal magnetic field (TF) coils in HT-7U tokamak device. At the same time, the design of coil support structure in the test facility is particularly discussed in some detail.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.61701515 and 61671458)the Postdoctoral Science Foundation,China(Grant No.2017M613367)+1 种基金the Natural Science Foundation of Hunan Province,China(Grant No.2018JJ3608)the Research Project of National University of Defense Technology,China(Grant No.ZK170204)
文摘Magnetic coils for specific requirements are widely used in modern quantum physics. In this study, a general analytical method of designing the shielded coils for generating an arbitrary axial magnetic field is proposed. The theoretical formula for an axial magnetic field generated by a single shielded coil is obtained and used to construct specific coils. The structural parameters of these coils are determined by fitting the theoretical formula with their specific requirements. The feasibility of this method is proved by realizing four concrete kinds of coils: uniform magnetic field generating coils, gradient magnetic field generating coils, asymmetrical uniform magnetic field generating coils, and parabolic magnetic field generating coils. The correctness of these theoretical results is demonstrated by both the finite element simulations and the relevant experimental results. Furthermore, the application of this method is of great significance for developing the quantum physics and quantum devices in future.
文摘This paper is devoted to predict AC loss of cable in conduit conductor (CICC) which is of importance in the design of conductors. The consideration for the conductor's design and main parameters for the magnets are introduced. In order to attain a good accuracy in the calculation of AC losses, the field distribution within superconducting outsert should be considered. Calculation of the AC losses, including hysteresis losses and coupling losses, is conducted. An emphasis is put on the hysteresis loss during the ramp up of the current to the operational current (15.3 kA) and the coupling loss of the conductor in a power-down condition for insert. The results are obtained to be 74.9 kJ and 950 J for 40 T hybrid magnets, respectively. Based on the calculation, a brief analysis of losses effect on the conductor design and the operation of magnet is given for the purpose that the capacity of the cryogenertor can be evaluated and the stability regime can be improved in our future work on the hybrid magnets.
文摘High vacuum is required for Vacuum Pressure Impregnation (VPI) process of large coils used in cryogenic. The defects such as dry spots and over rich resins should be minimized in large superconducting coils used. Both sealing problems associated with the mold and over rich resin problems are eliminated by using vacuum bag mold method with which we can simplify the design of vacuum mold.
基金supported by National Magnetic Confinement Fusion Science Program of China(No.2009GB101005)
文摘A set of in-vessel resonant magnetic perturbation (RMP) coils for MHD instability suppression is proposed for the design of a HL-2M tokamak. Each coil is to be fed with a current of up to 5 kA, operated in a frequency range from DC to about I kHz. Stainless steel (SS) jacketed mineral insulated cables are proposed for the conductor of the coils. In-vessel coils must withstand large electromagnetic (EM) and thermal loads. The support, insulation and vacuum sealing in a very limited space are crucial issues for engineering design. Hence finite element calculations are performed to verify the design, optimize the support by minimizing stress caused by EM forces on the coil conductors and work out the temperature rise occurring on the coil in different working conditions, the corresponding thermal stress caused by the thermal expansion of materials is evaluated to be allowable. The techniques to develop the in-vessel RMP coils, such as support, insulation and cooling, are discussed.
基金supported by the ITER Project Funds of China (No.2010GB107004)National Natural Science Funds of China (No.50907029)
文摘A set of four in-vessel saddle coils was designed to generate a helical field on the J- TEXT tokamak to study the influences of the external perturbation field on plasma. The coils are fed with alternating current up to 10 kA at frequency up to 10 kHz. Due to the special structure, complex thermal environment and limited space in the vacuum chamber, Jt is very important to make sure that the coils will not be damaged when undergoing the huge electromagnetic forces in the strong toroidal field, and that their temperatures don't rise too much and destroy the in- sulation. A 3D finite element model is developed in this paper using the ANSYS code, stresses are analyzed to find the worst condition, and a mounting method is then established. The results of the stress and modal analyses show that the mounting method meets the strength requirements. Finally, a thermal analysis is performed to study the cooling process and the temperature distribution of the coils.
基金This work is funded by the Magnetic Resonance Union of the Chinese Academy of Sciences(Grant No.2021gzl002)the International Partnership Program of Chinese Academy of Sciences(Grant No.182111KYSB20210014)+1 种基金the National Science Foundation of China(Grant No.52293423,Grant No.52277031)the Research and Development of Key Technologies and Equipment for Major Science and Technology Infrastructure of Development and Reform Commission of Shenzhen Municipality,China(Grant No.ZDKJ20190305002).
文摘The relatively fragile low-temperature stability of cryogen-free superconducting magnetic resonance imaging(MRI)magnets requires the careful management of exogenous heat sources.A strongly shielded gradient magnetic field is important for the optimal operation of cryogen-free MRI systems.In this study,we present an enhanced shielding method incorporating a regionalized stray field constraining strategy.By optimizing the constraint parameters,we could develop engineering-feasible gradient coil schemes without increasing system complexity but with the stray field intensity reduced by half.In real measurement in an integrated MRI system,the developed gradient assembly demonstrated good performance and supported to output images of excellent quality.Our findings suggested that the proposed method could potentially form a useful design paradigm for cryogen-free MRI magnets.
文摘Polygonal coil systems are designed for increasing and more kinds of sensors and electromagnetic systems.This paper presents a method for calculating mutual inductance between polygonal coils including irregular polygons.Based on the Biot-Savart law,the method calculates mutual inductance by dividing a polygonal coil into finite wires,and expresses the magnetic induction intensity generated by the excitation coil as a function of the spatial position of each vertex of the coil.The calculation method of the feasible region of the objective function is updated and the calculation process is simplified,so the calculation accuracy is improved.For octagon coils arbitrarily positioned in space,the accuracy of the algorithm is verified by the simulation and experiment.
基金This work was originally published in the Chinese Journal of Neuro-surgery (2001 17(2): 87-90) in Chinese.
文摘Objective. To compare the embolization effects of intracranial aneurysms with mechanical detachable spirals (MDS) and with Guglielmi detachable coils (GDC).Methods. One hundred and twenty cases with 125 intracranial aneurysms were embolized in Beijing Hospital from March 1995 to July 1999. Sixty - six aneurysms in 64 cases were embolized with MDS, 51 in 48 with GDC, and 8 in 8 with both MDS and GDC. Clinical data including sex, age, subarachnoid hemorrhage (SAH), Hunt & Hess grading, diameter and neck width of aneurysms, number and length of coils used per aneurysm, occlusive ratio, and complications were compared between MDS and GDC groups.Results. MDS and GDC groups were comparable (t-test or x2 -test, all P value > 0. 10) in terms of age, sex, diameter of aneurysms [ (8. 46 ± 3. 42) mm vs. (7. 38 ± 3. 45) mm], neck width [ (3. 49 ± 1. 50) mm vs. (3. 26 ± 1. 52) mm], coils number[ (4. 65 ± 3. 01) vs. (4. 24 ± 2. 65) ] and their length[ (460. 2 ± 398. 5) mm vs. (422. 9 ±387. 1) mm] used per aneurysm, occlusive ratio in aneurysms embolized ≥80% [ (95. 00% ± 6. 32% ) vs. (94. 19% ± 7. 63% ) ], mortality and permanent complications (7. 8% vs. 4. 2% ).Conclusions. MDS and GDC are all materials for embolization of intracranial aneurysms. MDS is less expensive, but more difficult to control and of propensity to complications while GDC is more compliant, easier to be used, safer, and have many alternative types for use as well as more extensive indications.
文摘Electrolytic detachable coils (EDC) have been the main embolic materi als for intracranial aneurysms. Liquid aneurysmal embolic materials represented by cellulose acetate polymer (CAP) are still in controversy. In this research, t he embolization results and pathological reactions after embolization of canine aneurysmal models with EDC or CAP were observed and compared. Methods. The canine aneurysmal models constructed by anastomosis of venous pouch es were randomly grouped. The aneurysms were respectively occluded with CAP and electrolytic detachable coils that was named by Wu electrolytic detachable coil (WEDC) and made by us. Angiogram follow ups were performed at 24 hour, 2 week , and 2 month after embolization. The occluded aneurysms were dissected in each stage for light microscopic, electron microscopic, and histochemical research. Results. The effect of embolization was significantly better with WEDC than that with CAP . Post embolized complications such as aneurysm rupture and stenosis of parent arteries could only be found in CAP group. Pathol ogical research showed that CAP mass could packed the aneurysms more densely tha n coils. Acute chemical damage of aneurysmal wall and inflammatory cell infiltra tion was prominently found in early stage after CAP embolization. Organization of thrombus inside aneurysms and formation of endothelial tissue over the orific es of aneurysmal necks could be found in both groups 2 months after embolization . But parts of coils might be exposed outside endothelial layer. Conclusions. EDC are still the most safe, efficient, and reliable instruments to embolize aneurysm. CAP should be improved further to solve the problem of stron g chemical corrosion and difficulty in control before it is widely used.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.51675506 and 51275504)the German Research Foundation(DFG)(Grant Nos.#ZA 422/5-1 and#ZA 422/6-1)
文摘A topology optimization method based on the solid isotropic material with penalization interpolation scheme is utilized for designing gradient coils for use in magnetic resonance microscopy.Unlike the popular stream function method,the proposed method has design variables that are the distribution of conductive material.A voltage-driven transverse gradient coil is proposed to be used as micro-scale magnetic resonance imaging(MRI)gradient coils,thus avoiding introducing a coil-winding pattern and simplifying the coil configuration.The proposed method avoids post-processing errors that occur when the continuous current density is approximated by discrete wires in the stream function approach.The feasibility and accuracy of the method are verified through designing the z-gradient and y-gradient coils on a cylindrical surface.Numerical design results show that the proposed method can provide a new coil layout in a compact design space.
基金supported by Hubei Provincial Natural Science Foundation of China(No.BZQ22006)Fundamental Research Funds for the Central Universities(No.CZY20028)+1 种基金National Magnetic Confinement Fusion Energy R&D Program of China(No.2018YFE0309102)National Natural Science Foundation of China(No.51821005)。
文摘The resonant magnetic perturbation(RMP)system is a powerful auxiliary system on tokamaks.On the J-TEXT tokamak,a set of new in-vessel coils is designed to enhance the amplitude of the RMP.The new coils are designed to be two-turn saddle coils.These two-turn saddle coils have been optimized in terms of their structure,support,and protection components to overcome the limitations of the narrow in-vessel space,resulting in a compact coil module that can be accommodated in the vessel.To verify the feasibility of this design,an electromagnetic simulation is performed to investigate the electrical parameters and the generated field of the coils.A multi-field coupled simulation is performed to investigate the capacity of heat dissipation.As a result of these efforts,the new RMP coils have been successfully installed on the J-TEXT tokamak.It has significantly enhanced the RMP amplitude and been widely applied in experiments.
基金the support by the National Key Research and Development Program of China(No.2019YFA0307701)National Natural Science Foundation of China(Nos.11674128,11674124 and 11974138)。
文摘Laser-induced breakdown spectroscopy(LIBS)is a powerful technique for elemental analysis,offering rapid analysis,minimal sample preparation,wide elemental coverage,and portability.To enhance the detection sensitivity of LIBS,increasing the spectral emission intensity is crucial.This paper explores the use of Tesla coil(TC)discharge as an alternative to spark discharge in silicon LIBS.The study examines the influence of TC discharge on both time-integrated and timeresolved spectra,with and without TC discharge;the corresponding electron temperature and density are obtained.The results show that TC discharge significantly amplifies the spectral intensity,improving signal sensitivity in LIBS analysis.Specifically,in the laser energy range from 7.4 to 24.0 mJ,TC discharge increased the average spectral line intensities of Si(II)385.60 nm and Si(I)390.55 nm by factors of 8.4 and 5.1,respectively.Additionally,the average electron temperature and density were enhanced by approximately 3.2%and 4.2%,respectively,under TC discharge.The advantages of TC discharge include higher energy deposition,extended discharge duration,reduced electrode erosion,and enhanced safety.This research contributes to advancing LIBS technology and expanding its applications in various fields.