For three phase four-wire active power filters (APFs), several typical power theories and corresponding current reference generation strategies are induced, p-q, d-q, unify power factor (UPF) and instantaneous act...For three phase four-wire active power filters (APFs), several typical power theories and corresponding current reference generation strategies are induced, p-q, d-q, unify power factor (UPF) and instantaneous active current (IAC) methods are analyzed and compared with each other. The interpretation of active and reactive currents in non-sinusoidal and unbalanced three-phase four-wire systems is given based on the generalized instantaneous reactive power theory. The performance and the characteristic are evaluated, and the application conditions of current reference generation strategies are concluded. Simulation results under different source voltages and loads verify the evaluation result.展开更多
This paper deals with power quality improvement using a three-phase active power filter(APF) connected to a PV power system. A direct power control(DPC) approach is proposed to eliminate harmonic current caused by any...This paper deals with power quality improvement using a three-phase active power filter(APF) connected to a PV power system. A direct power control(DPC) approach is proposed to eliminate harmonic current caused by any nonlinear loads and at the same time guarantees the delivery of a part of the load request from the same PV source. A boost converter is used for maximum power point(MPP) tracking purposes under various climate conditions through a fuzzy logic technique. The suggested study is tested under a MATLAB/Simulink environment. The obtained results depict the efficacy of the proposed procedures to meet the IEEE 519-1992 standard recommendation on harmonic levels.展开更多
In this paper the topology of a four-leg shunt active-power filter (APF) is given. The APF compensates har-monic and reactive power in a three-phase four-wire system. The scheme adopted for control of the four-leg act...In this paper the topology of a four-leg shunt active-power filter (APF) is given. The APF compensates har-monic and reactive power in a three-phase four-wire system. The scheme adopted for control of the four-leg active power filter,a 3-Dimensional Pulse Width Modulation (PWM) technique,is presented. The theoretical deduction of a space vector PWM (SVPWM) algorithm is given in this paper. The paper also analyzes the distribution of the volt-age-space vector of the four-leg converter in αβγ coordinates and describes methods to determine the location of the voltage-space vector and to calculate duration time. Finally,the algorithm is implemented in simulation; the results show that the total harmonic distortion (THD) of the three phase-current waveforms is reduced. The neutral wire current,after compensation,is about 0 A showing that the topology of the four-leg shunt APF is feasible and the proposed scheme is effective.展开更多
The China Fusion Engineering Test Reactor plans to build a 200 k V/25 A acceleration grid power supply(AGPS)for the negative-ion-based neutral beam injector prototype system.The AGPS uses a rectifier-inverter-isolated...The China Fusion Engineering Test Reactor plans to build a 200 k V/25 A acceleration grid power supply(AGPS)for the negative-ion-based neutral beam injector prototype system.The AGPS uses a rectifier-inverter-isolated step-up structure.There is a DC bus between the rectifier and the inverter.In order to limit DC bus voltage ripple and transient fluctuations,a large number of capacitors are used,which degrades the reliability of the power supply and occupies a large amount of space.This work finds that due to the difference in the turn-off time of the rectifier and the inverter,the capacitance mainly depends on the rectifier current when the inverter is turned off.On this basis,an active power filter(APF)scheme is proposed to absorb the current.To enhance the dynamic response ability of the APF,model predictive control is adopted.In this paper,the circuit structure of the APF is introduced,the prediction model is deduced,the corresponding control strategy and signal detection method are proposed,and the simulation and experimental results show that APF can track the transient current of the DC bus and reduce the voltage fluctuation significantly.展开更多
The growing problems of harmonic pollution on coal mine power lines caused by high-power DC drive systems has increased the use of active power filters.We analyzed compensation errors caused by the time lag in the det...The growing problems of harmonic pollution on coal mine power lines caused by high-power DC drive systems has increased the use of active power filters.We analyzed compensation errors caused by the time lag in the detecting circuits of an active power filter based on DSP control.We derived a mathematical model for the compensation error starting from the error estimation when a single distortion frequency is present.This model was then extended to the case where multiple frequencies are present in the distortion.A formula for a general theory of compensation error with fixed load and fixed lag time is presented.The theoretical analysis and experimental results show that the delay time of an active power filter mainly arises from the sampling time.Lower sampling frequencies introduce larger compensation errors in the active power filter reference current.展开更多
随着电力电子变频器装置以及各种非线性负载的大量使用,地铁供电系统的谐波也随之增多。地铁牵引变电所采用24脉波整流机组进行整流极大地降低了牵引供电系统的低次谐波。但这主动式谐波治理方案并不能有效减少地铁低压供配电系统谐波...随着电力电子变频器装置以及各种非线性负载的大量使用,地铁供电系统的谐波也随之增多。地铁牵引变电所采用24脉波整流机组进行整流极大地降低了牵引供电系统的低次谐波。但这主动式谐波治理方案并不能有效减少地铁低压供配电系统谐波含量。为进一步减少供电系统的谐波,提出在降压变电所0.4 k V侧安装有源电力滤波器(active power filter,APF)以对低压侧谐波进行有效治理。阐述了24脉波整流机组以及APF的工作原理;在基于瞬时无功功率理论的ip-iq法的基础上引入平均电流控制器和PI调节器替代低通滤波器,提出一种改进型的谐波电流检测方法并在此基础上对APF的控制策略进行分析;最后在Matlab/Simulink平台构建仿真模型进行验证,仿真结果表明所提出的基于谐波电流检测算法改进型的地铁供电系统APF对谐波抑制的有效性。展开更多
针对并联型有源电力滤波器(active power filter,APF)谐波检测环节的延时和谐波电流跟踪环节的鲁棒性差、跟踪精度不高的问题,建立了系统解耦后的数学模型,提出了基于递归最小二乘(recursive least squares,RLS)算法的并联型APF全局积...针对并联型有源电力滤波器(active power filter,APF)谐波检测环节的延时和谐波电流跟踪环节的鲁棒性差、跟踪精度不高的问题,建立了系统解耦后的数学模型,提出了基于递归最小二乘(recursive least squares,RLS)算法的并联型APF全局积分滑模变结构控制策略。谐波检测环节采用改进的瞬时无功功率理论的id-iq法,用RLS自适应滤波器替换传统的Butterworth低通滤波器,解决了传统的Butterworth低通滤波器因延时而导致的一个基波周期(20 ms)内检测盲区问题。谐波电流跟踪环节采用全局积分滑模变结构控制方法,引入了全局积分滑模面,运用Lyapunov稳定性理论导出的控制律兼顾了全局滑模的快速性和积分滑模的准确性。在解决了谐波检测环节延时的情况下,将全局积分滑模控制策略与传统的PI控制和滞环控制对比,仿真实验结果表明:全局积分滑模控制对指令电流具有更高的跟踪精度,且具有更低的电网侧电流总谐波畸变率(total harmonic distortion,THD)。展开更多
文摘For three phase four-wire active power filters (APFs), several typical power theories and corresponding current reference generation strategies are induced, p-q, d-q, unify power factor (UPF) and instantaneous active current (IAC) methods are analyzed and compared with each other. The interpretation of active and reactive currents in non-sinusoidal and unbalanced three-phase four-wire systems is given based on the generalized instantaneous reactive power theory. The performance and the characteristic are evaluated, and the application conditions of current reference generation strategies are concluded. Simulation results under different source voltages and loads verify the evaluation result.
文摘This paper deals with power quality improvement using a three-phase active power filter(APF) connected to a PV power system. A direct power control(DPC) approach is proposed to eliminate harmonic current caused by any nonlinear loads and at the same time guarantees the delivery of a part of the load request from the same PV source. A boost converter is used for maximum power point(MPP) tracking purposes under various climate conditions through a fuzzy logic technique. The suggested study is tested under a MATLAB/Simulink environment. The obtained results depict the efficacy of the proposed procedures to meet the IEEE 519-1992 standard recommendation on harmonic levels.
文摘In this paper the topology of a four-leg shunt active-power filter (APF) is given. The APF compensates har-monic and reactive power in a three-phase four-wire system. The scheme adopted for control of the four-leg active power filter,a 3-Dimensional Pulse Width Modulation (PWM) technique,is presented. The theoretical deduction of a space vector PWM (SVPWM) algorithm is given in this paper. The paper also analyzes the distribution of the volt-age-space vector of the four-leg converter in αβγ coordinates and describes methods to determine the location of the voltage-space vector and to calculate duration time. Finally,the algorithm is implemented in simulation; the results show that the total harmonic distortion (THD) of the three phase-current waveforms is reduced. The neutral wire current,after compensation,is about 0 A showing that the topology of the four-leg shunt APF is feasible and the proposed scheme is effective.
基金supported in part by the National Key Research and Development Program of China(No.2017YFE0300104)in part by National Natural Science Foundation of China(No.51821005)。
文摘The China Fusion Engineering Test Reactor plans to build a 200 k V/25 A acceleration grid power supply(AGPS)for the negative-ion-based neutral beam injector prototype system.The AGPS uses a rectifier-inverter-isolated step-up structure.There is a DC bus between the rectifier and the inverter.In order to limit DC bus voltage ripple and transient fluctuations,a large number of capacitors are used,which degrades the reliability of the power supply and occupies a large amount of space.This work finds that due to the difference in the turn-off time of the rectifier and the inverter,the capacitance mainly depends on the rectifier current when the inverter is turned off.On this basis,an active power filter(APF)scheme is proposed to absorb the current.To enhance the dynamic response ability of the APF,model predictive control is adopted.In this paper,the circuit structure of the APF is introduced,the prediction model is deduced,the corresponding control strategy and signal detection method are proposed,and the simulation and experimental results show that APF can track the transient current of the DC bus and reduce the voltage fluctuation significantly.
基金provided by the National Basic Research Program of China (No.2005CB221505)
文摘The growing problems of harmonic pollution on coal mine power lines caused by high-power DC drive systems has increased the use of active power filters.We analyzed compensation errors caused by the time lag in the detecting circuits of an active power filter based on DSP control.We derived a mathematical model for the compensation error starting from the error estimation when a single distortion frequency is present.This model was then extended to the case where multiple frequencies are present in the distortion.A formula for a general theory of compensation error with fixed load and fixed lag time is presented.The theoretical analysis and experimental results show that the delay time of an active power filter mainly arises from the sampling time.Lower sampling frequencies introduce larger compensation errors in the active power filter reference current.
文摘随着电力电子变频器装置以及各种非线性负载的大量使用,地铁供电系统的谐波也随之增多。地铁牵引变电所采用24脉波整流机组进行整流极大地降低了牵引供电系统的低次谐波。但这主动式谐波治理方案并不能有效减少地铁低压供配电系统谐波含量。为进一步减少供电系统的谐波,提出在降压变电所0.4 k V侧安装有源电力滤波器(active power filter,APF)以对低压侧谐波进行有效治理。阐述了24脉波整流机组以及APF的工作原理;在基于瞬时无功功率理论的ip-iq法的基础上引入平均电流控制器和PI调节器替代低通滤波器,提出一种改进型的谐波电流检测方法并在此基础上对APF的控制策略进行分析;最后在Matlab/Simulink平台构建仿真模型进行验证,仿真结果表明所提出的基于谐波电流检测算法改进型的地铁供电系统APF对谐波抑制的有效性。
文摘针对并联型有源电力滤波器(active power filter,APF)谐波检测环节的延时和谐波电流跟踪环节的鲁棒性差、跟踪精度不高的问题,建立了系统解耦后的数学模型,提出了基于递归最小二乘(recursive least squares,RLS)算法的并联型APF全局积分滑模变结构控制策略。谐波检测环节采用改进的瞬时无功功率理论的id-iq法,用RLS自适应滤波器替换传统的Butterworth低通滤波器,解决了传统的Butterworth低通滤波器因延时而导致的一个基波周期(20 ms)内检测盲区问题。谐波电流跟踪环节采用全局积分滑模变结构控制方法,引入了全局积分滑模面,运用Lyapunov稳定性理论导出的控制律兼顾了全局滑模的快速性和积分滑模的准确性。在解决了谐波检测环节延时的情况下,将全局积分滑模控制策略与传统的PI控制和滞环控制对比,仿真实验结果表明:全局积分滑模控制对指令电流具有更高的跟踪精度,且具有更低的电网侧电流总谐波畸变率(total harmonic distortion,THD)。