This is a review article describing some new and interesting aspects in the diagnosis and treatment in systemic vasculitis and demonstrating several cases that we have encountered.Particular emphasis will be put on Ta...This is a review article describing some new and interesting aspects in the diagnosis and treatment in systemic vasculitis and demonstrating several cases that we have encountered.Particular emphasis will be put on Takayasu arteritis(also known as aortitis syndrome)most commonly observed in Japan and other oriental countries.CT and MRI better demonstrate the vessel wall abnormality of Takayasu arteritis than angiography.Importance of plain chest radiograph should also be kept in mind;it could provide a clue in the diagnosis of Takayasu arteritis in its early stage.展开更多
The pore structure images of ore particles located at different heights of leaching column were scanned with X-ray computerized tomography (CT) scanner, the porosity and pore size distribution were calculated and the ...The pore structure images of ore particles located at different heights of leaching column were scanned with X-ray computerized tomography (CT) scanner, the porosity and pore size distribution were calculated and the geometrical shape and connectivity of pores were analyzed based on image process method, and the three dimensional reconstruction of pore structure images was realized. The results show that the porosity of ore particles bed in leaching column is 42.92%, 41.72%, 39.34% at top, middle and bottom zone, respectively. Obviously it has spatial variability and decreases appreciably along the height of the column. The overall average porosity obtained by image processing is 41.33% while the porosity gotten from general measurement method in laboratory is 42.77% showing the results of both methods are consistent well. The pore structure of ore granular media is characterized as a dynamical space network composed of interconnected pore bodies and pore throats. The ratio of throats with equivalent diameter less than 1.91 mm to the total pores is 29.31%, and that of the large pores with equivalent diameter more than 5.73 mm is 2.90%.展开更多
In order to develop the nonlinear echo image system to diagnose pathological changes in biological tissue , a simple physical model to analyse the character of nonlinear reflected wave in biological medium is postulat...In order to develop the nonlinear echo image system to diagnose pathological changes in biological tissue , a simple physical model to analyse the character of nonlinear reflected wave in biological medium is postulated . The propagation of large amplitude plane sound wave in layered biological media is analysed for the one dimensional case by the method of successive approximation and the expression for the second order wave reflected from any interface of layered biological media is obtained . The relations between the second order reflection coefficients and the nonlinear parameters of medium below the interface are studied in three layers interfaces. Finally, the second order reflection coefficients of four layered media are calculated numerically. The results indicate that the nonlinear parameter B/A of each layer of biological media can be determined by the reflection method.展开更多
A new interferometer for extreme ultraviolet (EUV) radiation with a laser produced plasma (LPP) laboratory source is under construction. The LPP source is operated with a Sn solid rod target on which pulsed YAG laser ...A new interferometer for extreme ultraviolet (EUV) radiation with a laser produced plasma (LPP) laboratory source is under construction. The LPP source is operated with a Sn solid rod target on which pulsed YAG laser is focused to produce high temperature plasma emitting EUV radiation. The source is equipped with a newly designed debris stopper protecting a condenser multilayer mirror from the particle debris of the target. The condenser mirror focuses the light onto an EUV beam-splitter to form transmitted and reflected paths for producing interference fringes of a sharing type. The optical configuration is of a common path based on a triangular path type with a focusing at the beam-splitter, which is enabled to produce fringes by a low coherence radiation with a standard optical quality beam-splitter. The fringes are recorded by an imaging plate with pixels as small as 25μm. The dynamic range of linearity in detection of the EUV light was found to be more than 10 4 with sensitivity of 10 4 photons/pixel, enough for the purpose of interferogram recording, possibly with one laser shot.展开更多
文摘This is a review article describing some new and interesting aspects in the diagnosis and treatment in systemic vasculitis and demonstrating several cases that we have encountered.Particular emphasis will be put on Takayasu arteritis(also known as aortitis syndrome)most commonly observed in Japan and other oriental countries.CT and MRI better demonstrate the vessel wall abnormality of Takayasu arteritis than angiography.Importance of plain chest radiograph should also be kept in mind;it could provide a clue in the diagnosis of Takayasu arteritis in its early stage.
基金Project(2004CB619205) supported by the National Key Fundamental Research and Development Program of ChinaProject(50325415) supported by the National Science Fund for Distinguished Young ScholarsProject(50574099) supported by the National Natural Science Foundation of China
文摘The pore structure images of ore particles located at different heights of leaching column were scanned with X-ray computerized tomography (CT) scanner, the porosity and pore size distribution were calculated and the geometrical shape and connectivity of pores were analyzed based on image process method, and the three dimensional reconstruction of pore structure images was realized. The results show that the porosity of ore particles bed in leaching column is 42.92%, 41.72%, 39.34% at top, middle and bottom zone, respectively. Obviously it has spatial variability and decreases appreciably along the height of the column. The overall average porosity obtained by image processing is 41.33% while the porosity gotten from general measurement method in laboratory is 42.77% showing the results of both methods are consistent well. The pore structure of ore granular media is characterized as a dynamical space network composed of interconnected pore bodies and pore throats. The ratio of throats with equivalent diameter less than 1.91 mm to the total pores is 29.31%, and that of the large pores with equivalent diameter more than 5.73 mm is 2.90%.
文摘In order to develop the nonlinear echo image system to diagnose pathological changes in biological tissue , a simple physical model to analyse the character of nonlinear reflected wave in biological medium is postulated . The propagation of large amplitude plane sound wave in layered biological media is analysed for the one dimensional case by the method of successive approximation and the expression for the second order wave reflected from any interface of layered biological media is obtained . The relations between the second order reflection coefficients and the nonlinear parameters of medium below the interface are studied in three layers interfaces. Finally, the second order reflection coefficients of four layered media are calculated numerically. The results indicate that the nonlinear parameter B/A of each layer of biological media can be determined by the reflection method.
文摘A new interferometer for extreme ultraviolet (EUV) radiation with a laser produced plasma (LPP) laboratory source is under construction. The LPP source is operated with a Sn solid rod target on which pulsed YAG laser is focused to produce high temperature plasma emitting EUV radiation. The source is equipped with a newly designed debris stopper protecting a condenser multilayer mirror from the particle debris of the target. The condenser mirror focuses the light onto an EUV beam-splitter to form transmitted and reflected paths for producing interference fringes of a sharing type. The optical configuration is of a common path based on a triangular path type with a focusing at the beam-splitter, which is enabled to produce fringes by a low coherence radiation with a standard optical quality beam-splitter. The fringes are recorded by an imaging plate with pixels as small as 25μm. The dynamic range of linearity in detection of the EUV light was found to be more than 10 4 with sensitivity of 10 4 photons/pixel, enough for the purpose of interferogram recording, possibly with one laser shot.
文摘目的探讨增强T2^(*)加权血管成像(enhanced T2 star-weighted angiography,ESWAN)序列中R2^(*)值、相位值、幅度值在T2WI低信号肾脏病变良恶性鉴别诊断中的可行性。材料与方法回顾性收集行ESWAN检查、经病理组织学证实的145例T2WI低信号肾脏病变患者(共145个病灶,恶性病变112个,良性病变33个)的术前MRI图像。在肿瘤最大面积的层面上绘制肿瘤T2WI低信号的感兴趣区。通过Kruskal-Wallis检验、卡方检验对参数进行比较,将有统计学意义的参数进行联合,通过多变量logistic回归建立模型,分析差异有统计学意义的参数,并且绘制其鉴别T2WI低信号肾脏病变良恶性的受试者工作特征(receiver operating characteristic,ROC)曲线,采用DeLong检验评价其诊断效能。结果R2^(*)值和幅度值鉴别T2WI低信号肾脏病变良恶性差异具有统计学意义(P=0.001)。R2^(*)值的ROC曲线下面积(area under the curve,AUC)为0.891[95%置信区间(confidence interval,CI):0.829~0.937,P<0.001],敏感度、特异度分别为97.3%、72.7%;幅度值的AUC为0.869(95%CI:0.803~0.920,P<0.001),敏感度、特异度分别为86.6%、81.8%;相位值的AUC为0.563(95%CI:0.478~0.645,P=0.249),敏感度、特异度分别为67.9%、54.6%;R2^(*)值联合幅度值的AUC为0.886(95%CI:0.823~0.933,P<0.001),敏感度、特异度分别为97.3%、72.7%;R2^(*)值联合病变长径的AUC为0.894(95%CI:0.832~0.939,P<0.001),敏感度、特异度分别为92.0%、81.8%;幅度值联合病变长径的AUC为0.858(95%CI:0.790~0.910,P<0.001),敏感度、特异度分别为75.9%、90.9%。结论R2^(*)值、R2^(*)值联合病变长径、R2^(*)值联合幅度值是鉴别T2WI低信号肾脏病变良恶性的有效方法,R2^(*)值联合病变长径具有更好的诊断性能。