Ultrafast pulse-dilation framing camera and its application for time-resolved X-ray diagnostic 被引量:2
1
作者 Hou-Zhi Cai Qiu-Yan Luo +10 位作者 Kai-Xuan Lin Xuan Deng Jun-Kai Liu Kai-Zhi Yang Dong Wang Jia-Jie Chen Jia-Heng Wang Jing-Hua Long Li-Hong Niu Yun-Fei Lei Jin-Yuan Liu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第7期101-114,共14页
An ultrafast framing camera with a pulse-dilation device,a microchannel plate(MCP)imager,and an electronic imaging system were reported.The camera achieved a temporal resolution of 10 ps by using a pulse-dilation devi... An ultrafast framing camera with a pulse-dilation device,a microchannel plate(MCP)imager,and an electronic imaging system were reported.The camera achieved a temporal resolution of 10 ps by using a pulse-dilation device and gated MCP imager,and a spatial resolution of 100μm by using an electronic imaging system comprising combined magnetic lenses.The spatial resolution characteristics of the camera were studied both theoretically and experimentally.The results showed that the camera with combined magnetic lenses reduced the field curvature and acquired a larger working area.A working area with a diameter of 53 mm was created by applying four magnetic lenses to the camera.Furthermore,the camera was used to detect the X-rays produced by the laser-targeting device.The diagnostic results indicated that the width of the X-ray pulse was approximately 18 ps. 展开更多
关键词 Inertial confinement fusion Plasma diagnostics Framing camera Combined lenses Pulse-dilation
在线阅读 下载PDF
A new Q-band comb-based multi-channel microwave Doppler backward scattering diagnostic developed on the HL-3 tokamak
2
作者 Ruihai TONG Yu ZHOU +8 位作者 Wulyu ZHONG Jie WEN Zhongbing SHI Xiaolan ZOU Anshu LIANG Zengchen YANG Min JIANG Xin YU Yuqi SHEN 《Plasma Science and Technology》 2025年第1期23-29,共7页
The Doppler backscattering(DBS)diagnostic is widely used to measure the localized density fluctuations and the propagation velocity of turbulent structures.Microwave is launched at a frequency that approaches a cutoff... The Doppler backscattering(DBS)diagnostic is widely used to measure the localized density fluctuations and the propagation velocity of turbulent structures.Microwave is launched at a frequency that approaches a cutoff layer in the plasma at an angle oblique to the cutoff layer.A new Q-band multichannel DBS system based on a comb generator has been designed and tested for application on the HL-3 tokamak.With the comb generator and heterodyne scheme,the stability and flexibility of the new DBS system are improved.The new DBS diagnostic has a high output power(~10 dBm),good power flatness(<5 dB in Q-band),and frequency stability,and the inter-frequency separation is tunable remotely.This article introduces the system design,laboratory test results,and initial experimental results from the HL-3 tokamak.With the help of the newly developed multichannel DBS,the turbulence information can be studied with high temporal and spatial resolution. 展开更多
关键词 Doppler backscattering(DBS) microwave diagnostic turbulence TOKAMAK
在线阅读 下载PDF
Soft x-ray Diode-array Diagnostic System for HT-7 Superconducting Tokamak 被引量:1
3
作者 胡立群 卫明生 +2 位作者 凌必利 方自深 曾立 《Plasma Science and Technology》 SCIE EI CAS CSCD 2000年第6期515-521,共7页
A diagnostic system of soft x-ray diode-array was set up for HT-7 superconducting tokamak. The system consists of two slot-aperture cameras and is capable of measuring the soft x-ray emission from the plasma on HT-7 d... A diagnostic system of soft x-ray diode-array was set up for HT-7 superconducting tokamak. The system consists of two slot-aperture cameras and is capable of measuring the soft x-ray emission from the plasma on HT-7 device with a high resolution in space and a high response in time. Both cameras, located separately in a horizontal port and a vertical port each with thirty-seven detectors of An-Si surface-barrier diode (SBD) can view the same toroidal cross-section of the plasma from different poloidal chords. In this paper, the structure, principle and performance of the diagnostic system are described and some experimental results observed are presented. 展开更多
关键词 LHCD Soft x-ray Diode-array diagnostic System for HT-7 Superconducting Tokamak HT SBD MODE
在线阅读 下载PDF
High-resolution x-ray monochromatic imaging for laser plasma diagnostics based on toroidal crystal 被引量:2
4
作者 司昊轩 董佳钦 +3 位作者 方智恒 蒋励 伊圣振 王占山 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第1期181-186,共6页
Monochromatic x-ray imaging is an essential method for plasma diagnostics related to density information.Large-field high-resolution monochromatic imaging of a He-like iron(Fe XXV)Kαcharacteristic line(6.701 keV)for ... Monochromatic x-ray imaging is an essential method for plasma diagnostics related to density information.Large-field high-resolution monochromatic imaging of a He-like iron(Fe XXV)Kαcharacteristic line(6.701 keV)for laser plasma diagnostics was achieved using a developed toroidal crystal x-ray imager.A high-index crystal orientation Ge(531)wafer with a Bragg angle of 75.37°and the toroidal substrate were selected to obtain sufficient diffraction efficiency and compensate for astigmatism under oblique incidence.A precise offline assembly method of the toroidal crystal imager based on energy substitution was proposed,and a spatial resolution of 3-7μm was obtained by toroidal crystal imaging of a 600 line-pairs/inch Au grid within an object field of view larger than 1.0 mm.The toroidal crystal x-ray imager has been successfully tested via side-on backlight imaging experiments of the sinusoidal modulation target and a 1000 line-pairs/inch Au grid with a linewidth of 5μm using an online alignment method based on dual positioning balls to indicate the target and backlighter.This paper describes the optical design,adjustment method,and experimental results of a toroidal crystal system in a laboratory and laser facility. 展开更多
关键词 laser plasma diagnostics toroidal crystal monochromatic x-ray imaging
在线阅读 下载PDF
A synthetic diagnostics platform for microwave imaging diagnostics in tokamaks
5
作者 李子涵 杨尚川 +5 位作者 徐新航 张立夫 渠承明 李诚普 庄革 谢锦林 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期38-45,共8页
Interpreting experimental diagnostics data in tokamaks,while considering non-ideal effects,is challenging due to the complexity of plasmas.To address this challenge,a general synthetic diagnostics(GSD)platform has bee... Interpreting experimental diagnostics data in tokamaks,while considering non-ideal effects,is challenging due to the complexity of plasmas.To address this challenge,a general synthetic diagnostics(GSD)platform has been established that facilitates microwave imaging reflectometry and electron cyclotron emission imaging.This platform utilizes plasma profiles as input and incorporates the finite-difference time domain,ray tracing and the radiative transfer equation to calculate the propagation of plasma spontaneous radiation and the external electromagnetic field in plasmas.Benchmark tests for classical cases have been conducted to verify the accuracy of every core module in the GSD platform.Finally,2D imaging of a typical electron temperature distribution is reproduced by this platform and the results are consistent with the given real experimental data.This platform also has the potential to be extended to 3D electromagnetic field simulations and other microwave diagnostics such as cross-polarization scattering. 展开更多
关键词 synthetic diagnostics tokamak plasmas microwave imaging diagnostics microwave imaging reflectometer electron cyclotron emission imaging
在线阅读 下载PDF
Polarimeter–interferometer diagnostic using terahertz solid-state sources for fluctuation measurements on Keda Torus e Xperiment(KTX)
6
作者 汪兴康 毛文哲 +17 位作者 谢锦林 兰涛 李弘 刘阿娣 周楚 温晓辉 卫子安 吴捷 陈晨 刘东宽 饶贤昊 蔡虎 邬佳仁 邓鹏 刘海庆 丁卫星 庄革 刘万东 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期61-65,共5页
A multi-channel polarimeter-interferometer has been developed on the Keda Torus eXperiment(KTX)for the study of equilibrium dynamics and internal magnetic fluctuations.A three-wave technique based on terahertz solid-s... A multi-channel polarimeter-interferometer has been developed on the Keda Torus eXperiment(KTX)for the study of equilibrium dynamics and internal magnetic fluctuations.A three-wave technique based on terahertz solid-state sources(-650 GHz)is applied for simultaneous measurements of electron density and Faraday rotation angle.The output power of the microwave source is 2 mW.Faraday rotation effect using a rotating wave plate is tested with phase noise less than 0.8°,and the density phase noise is less than 0.9°.Measurement of Faraday rotation angle and density for discharges on KTX have demonstrated high sensitivity to internal MHD activities. 展开更多
关键词 plasma diagnostics INTERFEROMETRY TERAHERTZ POLARIMETER
在线阅读 下载PDF
Development of D_α band symmetrical visible optical diagnostic for boundary reconstruction on EAST tokamak
7
作者 陈明 沈飊 +4 位作者 Shinichiro KADO 郭笔豪 陈大龙 蔡福瑞 肖炳甲 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第2期44-53,共10页
To investigate the potential of utilizing visible spectral imaging for controlling the plasma boundary shape during stable operation of plasma in future tokamak, a D_α band symmetric visible light diagnostic system w... To investigate the potential of utilizing visible spectral imaging for controlling the plasma boundary shape during stable operation of plasma in future tokamak, a D_α band symmetric visible light diagnostic system was designed and implemented on the Experimental Advanced Superconducting Tokamak(EAST). This system leverages two symmetric optics for joint plasma imaging. The optical system exhibits a spatial resolution less than 2 mm at the poloidal cross-section, distortion within the field of view below 10%, and relative illumination of 91%.The high-quality images obtained enable clear observation of both the plasma boundary position and the characteristics of components within the vacuum vessel. Following system calibration and coordinate transformation, the image coordinate boundary features are mapped to the tokamak coordinate system. Utilizing this system, the plasma boundary was reconstructed, and the resulting representation showed alignment with the EFIT(Equilibrium Fitting) results. This underscores the system's superior performance in boundary reconstruction applications and provides a diagnostic foundation for boundary shape control based on visible spectral imaging. 展开更多
关键词 visible optical diagnostic plasma boundary reconstruction EAST
在线阅读 下载PDF
Progress of the bolometer diagnostic system on EAST
8
作者 Wen WEN Yanmin DUAN +6 位作者 Shanshan PAN Yan CHAO Songtao MAO Jing QIAN Lingyi MENG Panjun TANG Shiyao LIN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第9期125-132,共8页
Measurements of the total radiated power and its spatial distribution are crucial for fusion research.On the experimental advanced superconducting tokamak(EAST),both the metal foil resistive bolometer and the absolute... Measurements of the total radiated power and its spatial distribution are crucial for fusion research.On the experimental advanced superconducting tokamak(EAST),both the metal foil resistive bolometer and the absolute extreme ultraviolet(AXUV)photodiodes have been used to quantify the radiated power.This article introduces the latest improvement of the bolometer diagnostic system on EAST.It also details the successful design and installation of new divertor AXUV cameras,which are dedicated to the investigation of divertor physics.The shielding components of the bolometer detector have been refined,and the article provides a detailed exposition of the double shielding structures that have been verified as effective in microwave shielding.Additionally,the changes in the radiated power distribution in the divertor region during the plasma detachment process are measured using the divertor AXUV camera.Finally,the radiated power measured by the AXUV detector and metal foil resistive bolometer are compared,and different detector performances are presented. 展开更多
关键词 radiated power bolometer diagnostic microwave shielding plasma detachment sensitivity degradation
在线阅读 下载PDF
Optical design of a novel near-infrared phase contrast imaging(NI-PCI)diagnostic on the HL-2A tokamak
9
作者 徐皓 龚少博 +11 位作者 余羿 许敏 兰涛 王志斌 石中兵 聂林 赵光义 刘灏 周艺轩 袁子豪 肖晨雨 陈坚 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期31-37,共7页
The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of tr... The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of traditional phase contrast technology.This diagnostic can work as a keen tool to measure plasma wavenumber spectra by inferring string-integrated plasma density fluctuations.Design of both the front optical path which is the path before the laser transmitting into the tokamak plasma and the rear optics which is the path after the laser passing through the plasma is detailed.The 1550 nm laser is chosen as the probe beam and highprecision optical components are designed to fit the laser beam,in which a phase plate with a 194-nm-deep silver groove is the key.Compared with the conventional 10.6μm laser-based PCI system on HL-2A,NI-PCI significantly overcomes the unwanted phase scintillation effect and promotes the measurement capability of high-wavenumber turbulence with an increased maximal measurable wavenumber from 15 cm^(-1)to 32.6 cm^(-1). 展开更多
关键词 phase contrast imaging near infrared laser plasma laser diagnostic
在线阅读 下载PDF
Diagnostic Accuracy of Computerized Bowel Sound Analysis with Non-Invasive Devices for Irritable Bowel Syndrome:A Systematic Review and Meta-Analysis
10
作者 Xia-Xiao Yan Yue-Lun Zhang +2 位作者 Yu-Pei Zhang Ying-Yun Yang Dong Wu 《Chinese Medical Sciences Journal》 CAS CSCD 2024年第2期122-130,共9页
Objective To assess the diagnostic accuracy of bowel sound analysis for irritable bowel syndrome(IBS)with a systematic review and meta-analysis.Methods We searched MEDLINE,Embase,the Cochrane Library,Web of Science,an... Objective To assess the diagnostic accuracy of bowel sound analysis for irritable bowel syndrome(IBS)with a systematic review and meta-analysis.Methods We searched MEDLINE,Embase,the Cochrane Library,Web of Science,and IEEE Xplore databases until September 2023.Cross-sectional and case-control studies on diagnostic accuracy of bowel sound analysis for IBS were identified.We estimated the pooled sensitivity,specificity,positive likelihood ratio,negative likeli-hood ratio,and diagnostic odds ratio with a 95% confidence interval(CI),and plotted a summary receiver operat-ing characteristic curve and evaluated the area under the curve.Results Four studies were included.The pooled diagnostic sensitivity,specificity,positive likelihood ratio,nega-tive likelihood ratio,and diagnostic odds ratio were 0.94(95%CI,0.87‒0.97),0.89(95%CI,0.81‒0.94),8.43(95%CI,4.81‒14.78),0.07(95%CI,0.03‒0.15),and 118.86(95%CI,44.18‒319.75),respectively,with an area under the curve of 0.97(95%CI,0.95‒0.98).Conclusions Computerized bowel sound analysis is a promising tool for IBS.However,limited high-quality data make the results'validity and applicability questionable.There is a need for more diagnostic test accuracy studies and better wearable devices for monitoring and analysis of IBS. 展开更多
关键词 irritable bowel syndrome bowel sound analysis diagnostic accuracy systematic review META-ANALYSIS
在线阅读 下载PDF
Design of Time-Resolved Shifted Dual Transmission Grating Spectrometer for the X-Ray Spectrum Diagnostics 被引量:1
11
作者 王保清 易涛 +6 位作者 王传珂 朱效立 李廷帅 李晋 刘慎业 江少恩 丁永坤 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第7期781-785,共5页
A new time-resolved shifted dual transmission grating spectrometer (SDTGS) is designed and fabricated in this work. This SDTGS uses a new shifted dual transmission grating (SDTG) as its dispersive component, which... A new time-resolved shifted dual transmission grating spectrometer (SDTGS) is designed and fabricated in this work. This SDTGS uses a new shifted dual transmission grating (SDTG) as its dispersive component, which has two sub transmission gratings with different line densities, of 2000 lines/mm and 5000 lines/mm. The axes of the two sub transmission gratings in SDTG are horizontally and vertically shifted a certain distance to measure a broad range of 0.1-5 keV time-resolved X-ray spectra. The SDTG has been calibrated with a soft X-ray beam of the synchrotron radiation facility and its diffraction efficiency is also measured. The designed SDTGS can take full use of the space on a record panel and improve the precision for measuring spatial and temporal spectrum simultaneously. It will be a promising application for accurate diagnosis of the soft X-ray spectrum in inertial confinement fusion. 展开更多
关键词 shifted dual transmission grating spectrometer GRATING x-ray spectra diag-nosis of the soft x-ray spectrum
在线阅读 下载PDF
Nanoarchitectonics of point-of-care diagnostics for sweat biomarkers analysis
12
作者 Xuan Lin Arya Vasanth +8 位作者 Aditya Ashok Hoang-Phuong Phan Kevin M.Koo Mohammed A.Amin Yusuf Valentino Kaneti Carlos Salomon Md Shahriar A.Hossain Yusuke Yamauchi Mostafa Kamal Masud 《Nano Materials Science》 CSCD 2024年第6期647-671,共25页
Sweat contains numerous vital biomarkers such as metabolites,electrolytes,proteins,nucleic acids and antigens that reflect hydration status,exhaustion,nutrition,and physiological changes.Conventional healthcare diagno... Sweat contains numerous vital biomarkers such as metabolites,electrolytes,proteins,nucleic acids and antigens that reflect hydration status,exhaustion,nutrition,and physiological changes.Conventional healthcare diagnosis relies on disease diagnostics in sophisticated centralized laboratories with invasive sample collection(e.g.,chemical analyses,plasma separation via centrifugation,tissue biopsy,etc.).Cutting-edge point-of-care diagnostics for sweat biomarker analysis allow for non-invasive monitoring of physiologically related biomarkers in sweat and real-time health status tracking.Moreover,using advanced nanoarchitectures,including nanostructured platforms and nanoparticles,can enhance the specificity,sensitivity,wearability and widen the sensing modality of sweat biosensors.Herein,we comprehensively review the secretory mechanisms,clinical uses of sweat biomarkers,and the design,principle,and latest technologies of sweat biosensors.With an emphasis on cutting-edge technologies for sweat biomarker analysis,this review chronicles the issues associated with the current sweat biomarkers analysis of sweat biomarkers and provides insights into strategies for enhancing the translation of such biosensors into routine clinical practice. 展开更多
关键词 Sweat biomarker Nanoarchitectonics NANOSTRUCTURES Sweat biosensor Point-of-care diagnostics Wearable sweat sensor
在线阅读 下载PDF
Metabolomic profiling of cerebrospinal fluid in neurosyphilis:identification of potential diagnostic biomarkers
13
作者 HE Yuanyuan WU Jiaxin +3 位作者 CHEN Zhaoqi DENG Ziliang WANG Haiying KE Wujian 《皮肤性病诊疗学杂志》 2024年第12期801-809,共9页
Objective This study aims to analyze metabolites in the cerebrospinal fluid(CSF)of neurosyphilis patients to identify potential diagnostic markers.Methods Untargeted metabolomics by liquid chromatography-mass spectrom... Objective This study aims to analyze metabolites in the cerebrospinal fluid(CSF)of neurosyphilis patients to identify potential diagnostic markers.Methods Untargeted metabolomics by liquid chromatography-mass spectrometry was used to analyze metabolites in CSF samples from five neurosyphilis and five syphilis/non-neurosyphilis patients.After quality control and normalization,data analyses(principal component analysis,orthogonal partial least squares-discriminant analysis,hierarchical clustering)were conducted to identify differential metabolites.Results The content of metabolites(Pro-leu,nudifloramide,N-oleoyl glycine,DMP 777,(±)-propionylcarnitine,and 3β-hydroxy-5-cholenoic acid)in neurosyphilis patients was 1.7-to 4.5-fold of that in the non-neurosyphilis patients.Conclusions The metabolites,particularly nudifloramide and N-oleoyl glycine,which have been implicated in other neurological disorders,warrant further investigation into their roles in the pathogenesis of neurosyphilis. 展开更多
关键词 NEUROSYPHILIS metabolomic profiling cerebrospinal fluid diagnostic biomarkers
在线阅读 下载PDF
Soft X-ray PHA Diagnostic for the Electron Ternperature Measurements on EAST
14
作者 许平 林士耀 +2 位作者 胡立群 段艳敏 张继宗 《Plasma Science and Technology》 SCIE EI CAS CSCD 2009年第4期468-471,共4页
Two soft X-ray pulse height analysis (PHA) systems, based on silicon drift detec- tor (SDD), were established on the experimental advanced superconducting tokamak (EAST) to measure spectrum of soft X-ray emissio... Two soft X-ray pulse height analysis (PHA) systems, based on silicon drift detec- tor (SDD), were established on the experimental advanced superconducting tokamak (EAST) to measure spectrum of soft X-ray emission. In this paper, the soft X-ray PHA systems on EAST are introduced and some experimental results of electron temperature in EAST obtained from the soft X-ray PHA diagnostic are presented. 展开更多
关键词 EAST soft x-ray PHA silicon driR detector (SDD) electron temperature(To)
在线阅读 下载PDF
Research on the X-ray polarization deconstruction method based on hexagonal convolutional neural network
15
作者 Ya-Nan Li Jia-Huan Zhu +5 位作者 Huai-Zhong Gao Hong Li Ji-Rong Cang Zhi Zeng Hua Feng Ming Zeng 《Nuclear Science and Techniques》 2025年第2期49-61,共13页
Track reconstruction algorithms are critical for polarization measurements.Convolutional neural networks(CNNs)are a promising alternative to traditional moment-based track reconstruction approaches.However,the hexagon... Track reconstruction algorithms are critical for polarization measurements.Convolutional neural networks(CNNs)are a promising alternative to traditional moment-based track reconstruction approaches.However,the hexagonal grid track images obtained using gas pixel detectors(GPDs)for better anisotropy do not match the classical rectangle-based CNN,and converting the track images from hexagonal to square results in a loss of information.We developed a new hexagonal CNN algorithm for track reconstruction and polarization estimation in X-ray polarimeters,which was used to extract the emission angles and absorption points from photoelectron track images and predict the uncer-tainty of the predicted emission angles.The simulated data from the PolarLight test were used to train and test the hexagonal CNN models.For individual energies,the hexagonal CNN algorithm produced 15%-30%improvements in the modulation factor compared to the moment analysis method for 100%polarized data,and its performance was comparable to that of the rectangle-based CNN algorithm that was recently developed by the Imaging X-ray Polarimetry Explorer team,but at a lower computational and storage cost for preprocessing. 展开更多
关键词 x-ray polarization Track reconstruction Deep learning Hexagonal conventional neural network
在线阅读 下载PDF
CMOS direct conversion X-ray detector coupled with fluorinated liquid
16
作者 Shi-Hua Liu Chao-Song Gao +5 位作者 Xin Zhang Xiang-Ming Sun Meng Wu Zhi-Hui Han Tong Wan Yong-Shuai Ge 《Nuclear Science and Techniques》 2025年第1期59-68,共10页
X-ray detectors show potential applications in medical imaging,materials science,and nuclear energy.To achieve high detection efficiency and spatial resolution,many conventional semiconductor materials,such as amorpho... X-ray detectors show potential applications in medical imaging,materials science,and nuclear energy.To achieve high detection efficiency and spatial resolution,many conventional semiconductor materials,such as amorphous selenium,cadmium telluride zinc,and perovskites,have been utilized in direct conversion X-ray detectors.However,these semiconductor materials are susceptible to temperature-induced performance degradation,crystallization,delamination,uneven lattice growth,radiation damage,and high dark current.This study explores a new approach by coupling an FC40 electronic fluorinated liquid with a specialized high-resolution and high-readout-speed complementary metal-oxide-semiconductor(CMOS)pixel array,specifically the Topmetal II−chip,to fabricate a direct conversion X-ray detector.The fluorinated liquid FC40(molecular formula:C_(21)F_(48)N_(2))is an electronic medium that is minimally affected by temperature and displays no issues with uniform conductivity.It exhibits a low dark current and minimal radiation damage and enables customizable thickness in X-ray absorption.This addresses the limitations inherent in conventional semiconductor-based detectors.In this study,simple X-ray detector imaging tests were conducted,demonstrating the excellent coupling capability between FC40 electronic fluorinated liquid and CMOS chips by the X-ray detector.A spatial resolution of 4.0 lp/mm was measured using a striped line par card,and a relatively clear image of a cockroach was displayed in the digital radiography imaging results.Preliminary test results indicated the feasibility of fabricating an X-ray detector by combining FC40 electronic fluorinated liquid and CMOS chips.Owing to the absence of issues related to chip-material coupling,a high spatial resolution could be achieved by reducing the chip pixel size.This method presents a new avenue for studies on novel liquid-based direct conversion X-ray detectors. 展开更多
关键词 FC40 electronic fluorinated liquid CMOS pixel chip x-ray detector Spatial resolution
在线阅读 下载PDF
Diagnostic Utility of Interferon-Gamma Release Assay in Tuberculous Lymphadenitis 被引量:2
17
作者 刘昕超 叶素素 +8 位作者 王文泽 张月秋 张丽帆 潘晓承 周子月 张妙颜 刘江浩 梁智勇 刘晓清 《Chinese Medical Sciences Journal》 CAS CSCD 2019年第4期233-240,共8页
Objective The aim of this study was to evaluate the diagnostic performance of T-SPOT.TB for tuberculous lymphadenitis.Methods Suspected tuberculous lymphadenitis patients between September 2010 and September 2018 who ... Objective The aim of this study was to evaluate the diagnostic performance of T-SPOT.TB for tuberculous lymphadenitis.Methods Suspected tuberculous lymphadenitis patients between September 2010 and September 2018 who had both peripheral blood T-SPOT.TB test and lymph node biopsy were retrospectively enrolled in this study.The cutoff value of T-SPOT.TB test for peripheral blood was set as 24 spot forming cell(SFC)/106 periphreral blood monocyte cell(PBMC)according to the instruction of testing kits.The gold standard for diagnosis of TBL was the combination of microbiology results,histopathology results and patient's response to anti-TB treatment.Diagnostic efficacy of T-SPOT.TB was evaluated,including sensitivity,specificity,accuracy,predictive values,and likelihood ratio.Results Among 91 patients who met the inclusion criteria,we excluded 8 cases with incomplete clinical information and 6 cases who lost to follow-up.According to the gold standard,there were 37 cases of true TBL(9 confirmed TBL and 28 probable TBL),30 cases of non-TBL,and 10 cases of clinically indeterminate diagnosis who were excluded from the final analyses.The T-SPOT.TB tests yielded 43 cases of positive response and 24 cases of negative response.The sensitivity,specificity,accuracy,positive predictive value(PPV),negative predictive value(NPV),positive likelihood ratio(PLR)and negative likelihood ratio(NLR)of peripheral blood T-SPOT.TB for diagnosing TBL were 89.2%,66.7%,79.1%,76.7%,83.3%,2.68 and 0.16,respectively.The number of SFCs of T-SPOT.TB in TBL patients[432(134-1264)/106 PBMCs]was higher than that in non-TBL patients[0(0-30)/106 PBMCs]with a significant difference(Z=-5.306,P<0.001).Conclusion T-SPOT.TB is a rapid and simple diagnostic test for TBL with a high sensitivity and negative predictive value. 展开更多
关键词 Tuberculous lymphadenitis(TBL) T-SPOT.TB diagnostic test sensitivity SPECIFICITY
在线阅读 下载PDF
Optimized online filter stack spectrometer for ultrashort X-ray pulses
18
作者 Jia-Xing Wen Ge Ma +17 位作者 Ming-Hai Yu Yu-Chi Wu Yong-Hong Yan Shao-Yi Wang Huai-Zhong Gao Lu-Shan Wang Yu-Gang Zhou Qiang Li Yue Yang Fang Tan Xiao-Hui Zhang Jie Zhang Wen-Bo Mo Jing-Qin Su Wei-Min Zhou Yu-Qiu Gu Ming Zeng Zong-Qing Zhao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第5期85-98,共14页
Currently,with the advent of high-repetition-rate laser-plasma experiments,the demand for online diagnosis for the X-ray spectrum is increasing because the laser-plasma-generated X-ray spectrum is very important for c... Currently,with the advent of high-repetition-rate laser-plasma experiments,the demand for online diagnosis for the X-ray spectrum is increasing because the laser-plasma-generated X-ray spectrum is very important for characterizing electron dynamics and applications.In this study,scintillators and silicon PIN(P-type–intrinsic-N-type semiconductor)diodes were used to construct a wideband online filter stack spectrometer.The X-ray sensor and filter arrangement was optimized using a genetic algorithm to minimize the condition number of the response matrix.Consequently,the unfolding error was significantly reduced based on numerical experiments.The detector responses were quantitatively calibrated by irradiating the scintillator and PIN diode with various nuclides and comparing the measuredγ-ray peaks.A prototype 15-channel spectrometer was developed by integrating an X-ray detector with front-and back-end electronics.The prototype spectrometer could record X-ray pulse signals at a repetition rate of 1 kHz.Furthermore,an optimized spectrometer was employed to record the real-time spectra of laser-driven bremsstrahlung sources.This optimized spectrometer offers a compact solution for spectrum diagnostics of ultrashort X-ray pulses,exhibiting improved accuracy in terms of spectrum measurements and repetition rates,and could be widely used in next-generation high-repetition-rate high-power laser facilities. 展开更多
关键词 Filter stack spectrometer Laser plasma diagnostics x-ray diagnostics Scintillator PIN diode
在线阅读 下载PDF
A Self-Powered Breath Analyzer Based on PANI/PVDF Piezo-Gas-Sensing Arrays for Potential Diagnostics Application 被引量:8
19
作者 Yongming Fu Haoxuan He +6 位作者 Tianming Zhao Yitong Dai Wuxiao Han Jie Ma Lili Xing Yan Zhang Xinyu Xue 《Nano-Micro Letters》 SCIE EI CAS 2018年第4期354-365,共12页
The increasing morbidity of internal diseases poses serious threats to human health and quality of life.Exhaled breath analysis is a noninvasive and convenient diagnostic method to improve the cure rate of patients. I... The increasing morbidity of internal diseases poses serious threats to human health and quality of life.Exhaled breath analysis is a noninvasive and convenient diagnostic method to improve the cure rate of patients. In this study, a self-powered breath analyzer based on polyaniline/polyvinylidene fluoride(PANI/PVDF) piezogas-sensing arrays has been developed for potential detection of several internal diseases. The device works by converting exhaled breath energy into piezoelectric gassensing signals without any external power sources. The five sensing units in the device have different sensitivities to various gas markers with concentrations ranging from 0 to 600 ppm. The working principle can be attributed to the coupling of the in-pipe gas-flow-induced piezoelectric effect of PVDF and gas-sensing properties of PANI electrodes. In addition, the device demonstrates its use as an ethanol analyzer to roughly mimic fatty liver diagnosis.This new approach can be applied to fabricating new exhaled breath analyzers and promoting the development of self-powered systems. 展开更多
关键词 Polyaniline Polyvinylidene fluoride Piezoelectric Sensor array diagnosticS Breath analyzer
在线阅读 下载PDF
Plasma diagnostics by optical emission spectroscopy on manganese ore in conjunction with XRD, XRF and SEM-EDS 被引量:4
20
作者 Muhammad FAHAD Sajad ALI Yaseen IQBAL 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第8期103-110,共8页
Manganese(Mn) is an important industrial mineral.Information about the chemical and phase constitution along with the concentration of impurities presented in Mn ore is compulsory in assessing its suitability for diff... Manganese(Mn) is an important industrial mineral.Information about the chemical and phase constitution along with the concentration of impurities presented in Mn ore is compulsory in assessing its suitability for different applications.We performed the qualitative and quantitative analysis of low-grade Mn ore(LGMO) using laser-induced breakdown spectroscopy(LIBS) in conjunction with x-ray diffraction(XRD), x-ray fluorescence(XRF) and scanning electron microscopy(SEM) coupled with energy dispersive x-ray electron spectroscopy(EDS).The optical emission spectra of the LGMO sample displayed the presence of Mn, Si, Ca, Fe, Al, Mg,V, Ti, Sr, Ni, Na, Ba and Li.The plasma parameters, electron temperature and number density were estimated using the Boltzmann plot and Stark broadening line profile methods and were found to be 7500 K±750 K and 8.18±0.8×1017 cm-3, respectively.Quantitative analysis was performed using the calibration-free LIBS(CF-LIBS) method and its outcome along with XRD, XRF and SEM-EDS data showed almost analogous elemental composition, while the LIBS method gave acceptably precise elemental analysis by detecting the low atomic number element Li besides V and Sr.The results obtained using LIBS for the LGMO exhibited its ability as a powerful analytical tool and XRF, XRD and SEM-EDS as complementary methods for the compositional analysis of complex low-grade mineral ore. 展开更多
关键词 plasma diagnostic optical emission SPECTROSCOPY spectrochemical analysis LASER-INDUCED BREAKDOWN SPECTROSCOPY SEM-EDS
在线阅读 下载PDF