On the basis of practical projects in Chongqing,the thermal performance of heat exchangers (single U-tube type and double U-tube type) of the ground-source heat pump (GSHP) system in the hot summer was obtained and an...On the basis of practical projects in Chongqing,the thermal performance of heat exchangers (single U-tube type and double U-tube type) of the ground-source heat pump (GSHP) system in the hot summer was obtained and analyzed. The data obtained from test could match with the result deduced from theoretical calculation. From the test results,the cooling capacity of double U-tube is 1.6 times that of single U-tube. Taking cost per depth per watt Clq as the evaluation standard,Clq of single U-tube is 4.69 RMB$/W,and Clq of double U-tube is 3.14 RMB$/W. The double U-tube heat exchangers usage should be prioritized.展开更多
In this research,the thermal performance of a single U-tube vertical ground heat exchanger is evaluated numerically as a function of the most influential flow parameters,namely,the soil porosity,volumetric heat capaci...In this research,the thermal performance of a single U-tube vertical ground heat exchanger is evaluated numerically as a function of the most influential flow parameters,namely,the soil porosity,volumetric heat capacity,and thermal conductivity of the backfill material,inlet volume flow rate,and inlet fluid temperature.The results are discussed in terms of the variations of the heat exchange rate,the effective thermal resistance,and the effectiveness of the ground heat exchanger.They show that the inlet volume flow rate,inlet fluid temperature,and backfill material thermal conductivity have significant effects on the thermal performance of the ground heat exchanger,such that by decreasing the inlet volume flow rate and increasing the backfill material thermal conductivity and inlet fluid temperature,the outlet fluid temperature decreases considerably.On the contrary,the soil porosity and backfill material volumetric heat capacity have negligible effects on the studied ground heat exchanger’s thermal performance.The lowest inlet fluid temperature reaches a the maximum effective thermal resistance of borehole and soil,and consequently the minimum heat transfer rate and effectiveness.Also,multilinear regression analyses are performed to determine the most feasible models able to predict the thermal properties of the single U-tube ground heat exchanger.展开更多
Heat exchange performance of vertical U-tube heat exchanger was studied with two different borehole fill materials and CFD software. Borehole surface temperature and water temperature distribution were simulated on th...Heat exchange performance of vertical U-tube heat exchanger was studied with two different borehole fill materials and CFD software. Borehole surface temperature and water temperature distribution were simulated on the condition of continuous operation for 8 h in winter with inlet water temperature being 10℃. The results show that there is no obvious difference on heat exchanger performance between the two different borehole fill materials.展开更多
In order to increase the efficiency of solar collector, a methodology is proposed based on the analysis of its influencing factors, such as thermal conductivity of filled layer, structure forms of filled layer and hea...In order to increase the efficiency of solar collector, a methodology is proposed based on the analysis of its influencing factors, such as thermal conductivity of filled layer, structure forms of filled layer and heat loss coefficient. The results of analysis show that the heat transfer between pipes in evacuated tube is one of the most important factors, which can lead to the decrease of the outlet temperature of working fluid. In order to eliminate the negative influence of the heat transfer between pipes, the hollow filled-type evacuated tube with U-tube(HUFET) was developed, and the heat transfer characteristics of HUFET were analyzed by theoretical and experimental studies. The results show that the thermal resistances decrease with the increase of the thermal conductivity of filled layer. When the thermal conductivity is over 10 W/(m·K), the change of thermal resistances is very little.Furthermore, the larger the thermal conductivity of filled layer, the less the rate of the energy transfer between the two pipes to the total energy transfer, which is between the absorber tube and the working fluid. There is a little difference between the efficiencies of HUFET and UFET, with the efficiency of HUFET 2.4% higher than that of UFET. Meanwhile, the validation of the model developed was confirmed by the experiment.展开更多
文摘On the basis of practical projects in Chongqing,the thermal performance of heat exchangers (single U-tube type and double U-tube type) of the ground-source heat pump (GSHP) system in the hot summer was obtained and analyzed. The data obtained from test could match with the result deduced from theoretical calculation. From the test results,the cooling capacity of double U-tube is 1.6 times that of single U-tube. Taking cost per depth per watt Clq as the evaluation standard,Clq of single U-tube is 4.69 RMB$/W,and Clq of double U-tube is 3.14 RMB$/W. The double U-tube heat exchangers usage should be prioritized.
文摘In this research,the thermal performance of a single U-tube vertical ground heat exchanger is evaluated numerically as a function of the most influential flow parameters,namely,the soil porosity,volumetric heat capacity,and thermal conductivity of the backfill material,inlet volume flow rate,and inlet fluid temperature.The results are discussed in terms of the variations of the heat exchange rate,the effective thermal resistance,and the effectiveness of the ground heat exchanger.They show that the inlet volume flow rate,inlet fluid temperature,and backfill material thermal conductivity have significant effects on the thermal performance of the ground heat exchanger,such that by decreasing the inlet volume flow rate and increasing the backfill material thermal conductivity and inlet fluid temperature,the outlet fluid temperature decreases considerably.On the contrary,the soil porosity and backfill material volumetric heat capacity have negligible effects on the studied ground heat exchanger’s thermal performance.The lowest inlet fluid temperature reaches a the maximum effective thermal resistance of borehole and soil,and consequently the minimum heat transfer rate and effectiveness.Also,multilinear regression analyses are performed to determine the most feasible models able to predict the thermal properties of the single U-tube ground heat exchanger.
基金Project(CSTC 2004AA7008 2 2) supported by Key Technologies for Development of Small Cities of ChongqingMunicipality
文摘Heat exchange performance of vertical U-tube heat exchanger was studied with two different borehole fill materials and CFD software. Borehole surface temperature and water temperature distribution were simulated on the condition of continuous operation for 8 h in winter with inlet water temperature being 10℃. The results show that there is no obvious difference on heat exchanger performance between the two different borehole fill materials.
基金Projects(2011BAJ03B12-3,2013BAJ10B02-03) supported by the National Science and Technology Program during the 12th Five-year Plan Period,ChinaProject(51378005) supported by the National Natural Science Foundation,China+1 种基金Projects(DUT14RC(3)123,DUT14RC(3)129) supported by Fundamental Research Funds for the Dalian University of Tecnology,ChinaProject(DUT14ZD210) supported by the Fundamental Research Funds for the Central Universities of China
文摘In order to increase the efficiency of solar collector, a methodology is proposed based on the analysis of its influencing factors, such as thermal conductivity of filled layer, structure forms of filled layer and heat loss coefficient. The results of analysis show that the heat transfer between pipes in evacuated tube is one of the most important factors, which can lead to the decrease of the outlet temperature of working fluid. In order to eliminate the negative influence of the heat transfer between pipes, the hollow filled-type evacuated tube with U-tube(HUFET) was developed, and the heat transfer characteristics of HUFET were analyzed by theoretical and experimental studies. The results show that the thermal resistances decrease with the increase of the thermal conductivity of filled layer. When the thermal conductivity is over 10 W/(m·K), the change of thermal resistances is very little.Furthermore, the larger the thermal conductivity of filled layer, the less the rate of the energy transfer between the two pipes to the total energy transfer, which is between the absorber tube and the working fluid. There is a little difference between the efficiencies of HUFET and UFET, with the efficiency of HUFET 2.4% higher than that of UFET. Meanwhile, the validation of the model developed was confirmed by the experiment.