期刊文献+
共找到59篇文章
< 1 2 3 >
每页显示 20 50 100
Simultaneous fluorescence and Compton scattering computed tomography based on linear polarization X-ray
1
作者 Zhi-Jun Chi Hong-Ze Zhang +7 位作者 Jin Lin Xuan-Qi Zhang Hao Ding Qi-Li Tian Zhi Zhang Ying-Chao Du Wen-Hui Huang Chuan-Xiang Tang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第10期41-50,共10页
Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of th... Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of the proposed method.In the simulations,the phantom is a polytetrafluoroethylene cylinder inside which are cylindrical columns containing aluminum,water,and gold(Au)-loaded water solutions with Au concentrations ranging between 0.5 and 4.0 wt%,and a parallel-hole collimator imaging geometry was adopted.The light source was modeled based on a Thomson scattering X-ray source.The phantom images for both imaging modalities were reconstructed using a maximumlikelihood expectation maximization algorithm.Results Both the X-ray fluorescence computed tomography(XFCT)and Compton scattering computed tomography(CSCT)images of the phantom were accurately reconstructed.A similar attenuation contrast problem for the different cylindrical columns in the phantom can be resolved in the XFCT and CSCT images.The interplay between XFCT and CSCT was analyzed,and the contrast-to-noise ratio(CNR)of the reconstruction was improved by correcting for the mutual influence between the two imaging modalities.Compared with K-edge subtraction imaging,XFCT exhibits a CNR advantage for the phantom.Conclusion Simultaneous XFCT and CSCT can be realized by using linearly polarized X-rays.The synergy between the two imaging modalities would have an important application in cancer radiation therapy. 展开更多
关键词 x-ray fluorescence computed tomography Compton scattering computed tomography Linear polarization Thomson scattering x-ray source Monte Carlo simulation
在线阅读 下载PDF
Tracking the phase transformation and microstructural evolution of Sn anode using operando synchrotron X-ray energy-dispersive diffraction and X-ray tomography 被引量:1
2
作者 Kang Dong Fu Sun +4 位作者 Andre Hilger Paul H.Kamm Markus Osenberg Francisco Garcia-Moreno Ingo Manke 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2023年第1期429-437,I0011,共10页
Tin(Sn)holds great promise as an anode material for next-generation lithium(Li)ion batteries but suffers from massive volume change and poor cycling performance.To clarify the dynamic chemical and microstructural evol... Tin(Sn)holds great promise as an anode material for next-generation lithium(Li)ion batteries but suffers from massive volume change and poor cycling performance.To clarify the dynamic chemical and microstructural evolution of Sn anode during lithiation and delithiation,synchrotron X-ray energydispersive diffraction and X-ray tomography are simultaneously employed during Li/Sn cell operation.The intermediate Li-Sn alloy phases during de/lithiation are identified,and their dynamic phase transformation is unraveled which is further correlated with the volume variation of the Sn at particle-and electrode-level.Moreover,we find that the Sn particle expansion/shrinkage induced particle displacement is anisotropic:the displacement perpendicular to the electrode surface(z-axis)is more pronounced compared to the directions(x-and y-axis)along the electrode surface.This anisotropic particle displacement leads to an anisotropic volume variation at the electrode level and eventually generates a net electrode expansion towards the separator after cycling,which could be one of the root causes of mechanical detachment and delamination of electrodes during long-term operation.The unraveled chemical evolution of Li-Sn and deep insights into the microstructural evolution of Sn anode provided here could guide future design and engineering of Sn and other alloy anodes for high energy density Li-and Na-ion batteries. 展开更多
关键词 Sn anode Li-Sn phase transformation x-ray tomography Operando x-ray diffraction Anisotropic displacement Digital volume correlation(DVC)
在线阅读 下载PDF
X-ray tomography study on the structure of the granular random loose packing 被引量:1
3
作者 邢义 邱宇鹏 +2 位作者 王智 叶佳超 李向亭 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第8期215-218,共4页
Random loose packing is the minimum-density granular packing which can maintain mechanical stability. In this study, x-ray tomography is used to investigate the internal structure of an isotropically prepared random l... Random loose packing is the minimum-density granular packing which can maintain mechanical stability. In this study, x-ray tomography is used to investigate the internal structure of an isotropically prepared random loose packing through a special apparatus to minimize the effect of gravity. It is found that the minimum packing density is around 0.587. The microscopic structural analysis of the packing is also carried out. 展开更多
关键词 granular systems random loose packing x-ray tomography
在线阅读 下载PDF
In situ compression and X-ray computed tomography of flow battery electrodes 被引量:1
4
作者 Rhodri Jervis Matt D.R.Kok +6 位作者 Tobias P.Neville Quentin Meyer Leon D.Brown Francesco Iacoviello Jeff T.Gostick Dan J.L.Brett Paul R.Shearing 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2018年第5期1353-1361,共9页
Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised... Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised due to cost and performance issues, many of which are linked to the microstructure of the porous carbon electrodes used. Here, for the first time, we offer a detailed study of the in situ effects of compression on a commercially available carbon felt electrode. Visualisation of electrode structure us- ing X-ray computed tomography shows the non-linear way that these materials compress and various metrics are used to elucidate the changes in porosity, pore size distribution and tortuosity factor under compressions from 0%-90%. 展开更多
关键词 Redox flow battery x-ray computed tomography Compression Carbon felt RFB
在线阅读 下载PDF
Fast synchrotron X-ray tomography study of the packing structures of rods with different aspect ratios 被引量:1
5
作者 张晓丹 夏成杰 +1 位作者 肖相辉 王宇杰 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第4期373-376,共4页
We present a fast synchrotron X-ray tomography study of the packing structures of rods with different aspect ratios. Utilizing the high flux of the X-rays generated from the third-generation synchrotron source, we can... We present a fast synchrotron X-ray tomography study of the packing structures of rods with different aspect ratios. Utilizing the high flux of the X-rays generated from the third-generation synchrotron source, we can complete a high- resolution tomography scan within a short period of time, after which the three-dimensional (3D) packing structure can be obtained for the subsequent structural analysis. The image phase-retrieval procedure has been implemented to enhance the image contrast. We systematically investigated the effects of particle shape and aspect ratio on the structural properties including packing density and contact number. It turns out that large aspect ratio rod packings will have wider distributions of free volume fraction and larger mean contact numbers. 展开更多
关键词 synchrotron x-ray imaging tomography rod packing structure
在线阅读 下载PDF
Seeing through Materials:X-Ray Imaging Using Computed Tomography 被引量:1
6
作者 Yisheng Miao Chengpeng Xue +2 位作者 Xuelong Wu Zhongyao Li Junsheng Wang 《Journal of Beijing Institute of Technology》 EI CAS 2023年第4期494-516,共23页
X-ray computed tomography(XCT)has recently emerged as a powerful tool for characterizing the evolution of microstructure during phase transformation in three dimensional(3D)such as dendritic solidification of alloys.T... X-ray computed tomography(XCT)has recently emerged as a powerful tool for characterizing the evolution of microstructure during phase transformation in three dimensional(3D)such as dendritic solidification of alloys.This paper briefly reviews the recent advances in the in-situ observation of aluminium alloys,magnesium alloys and nickel-based superalloys during solidification using laboratory XCT and synchrotron X-ray sources.The focus is on the growth kinetics of dendrites,porosity and secondary phases.In addition,in-situ characterization during the loading and corrosion process is also discussed. 展开更多
关键词 x-ray computed tomography(XCT) SYNCHROTRON DENDRITE POROSITY ALLOYS
在线阅读 下载PDF
Study of sawtooth oscillations on the HT-7 tokamak using 2D tomography of soft x-ray signal 被引量:1
7
作者 马天鹏 胡立群 +8 位作者 万宝年 阮怀林 高翔 甄香君 周立武 孙有文 陈忠勇 林士耀 孔伟 《Chinese Physics B》 SCIE EI CAS CSCD 2005年第10期2061-2067,共7页
It is the first time so far as we know that two arrays of multi-channel soft x-ray detectors are used to generate twodimensional (2D) images of sawtooth oscillation on the HT-7 tokamak using the Fourier-Bessel harmo... It is the first time so far as we know that two arrays of multi-channel soft x-ray detectors are used to generate twodimensional (2D) images of sawtooth oscillation on the HT-7 tokamak using the Fourier-Bessel harmonic reconstruction method, and using the singular value decomposition to analyse the data from soft x-ray cameras. By these two arrays, 2D image reconstruction of soft x-ray emissivity can be obtained without assumption of plasma rigid rotation. Tomographic reconstruction of the m=1 mode structure is obtained during the precursor oscillation of the sawtooth crash. The crescent-shaped mode structure appearing on the contour map of the soft x-ray emissivity is consistent with the quasiinterchange mode. The characteristics of the m=1/n=1 mode structure observed in the soft x-ray tomography are as follows: the magnetic surface is made up of the crescent-shaped “hot core” and the circular “cold bubble”. The structure of the magnetic surface rotates in the direction of the electron diamagnetic drift and the rotation frequency is the oscillation frequency of soft x-ray signals. 展开更多
关键词 soft x-ray tomography sawtooth oscillation singular value decomposition (SVD)
在线阅读 下载PDF
Soft X-ray Tomography on HT-7
8
作者 陈开云 胡立群 +2 位作者 丁玥 马天鹏 段艳敏 《Plasma Science and Technology》 SCIE EI CAS CSCD 2009年第4期472-476,共5页
The soft X-ray imaging system on HT-7 is introduced. Fourier-Bessel expansion method is used to reconstruct the soft X-ray emission distribution. Simulation results show that the inversion accuracy is associated with ... The soft X-ray imaging system on HT-7 is introduced. Fourier-Bessel expansion method is used to reconstruct the soft X-ray emission distribution. Simulation results show that the inversion accuracy is associated with the angular expansion limit and the hot core displacement. In addition, tomographic results of sawtooth oscillations in a typical low hybrid current drive (LHCD) plasma are presented. It is shown that the reconstructions are reliable to analyze the perturbative mode and the evolution. 展开更多
关键词 tomography SAWTOOTH soft x-ray
在线阅读 下载PDF
New flexible CsPbBr_(3)-based scintillator for X-ray tomography
9
作者 Zhi-Wei Lü Gong-Xiang Wei +6 位作者 Han-Qiu Wang Yu Guan Ning Jiang Yun-Yan Liu Zhao Li Hua Qin Hui-Qiang Liu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第8期34-44,共11页
The evolution of lead halide perovskites used for X-ray imaging scintillators has been facilitated by the development of solution-processable semiconductors characterized by large-area,flexible,fast photoresponse.The ... The evolution of lead halide perovskites used for X-ray imaging scintillators has been facilitated by the development of solution-processable semiconductors characterized by large-area,flexible,fast photoresponse.The stability and durability of these new perovskites are insufficient to achieve extended computed tomography scanning times with hard X-rays.In this study,we fabricated a self-assembled CsPbBr_(3)-based scintillator film with a flexible large-area uniform thickness using a new roomtemperature solution-processable method.The sensitivity and responsivity of X-ray photon conversion were quantitatively measured and showed a good linear response relationship suitable for X-ray imaging.We also demonstrated,for the first time,that the self-assembled CsPbBr_(3)-based scintillator has good stability for hard X-ray microtomography.Therefore,such an inexpensive solution-processed semiconductor easily prepared at room temperature can be used as a hard X-ray scintillator and equipped with flexible CsPbBr3-based X-ray detectors.It has great potential in three-dimensional high-resolution phase-contrast X-ray-imaging applications in biomedicine and material science because of its heavy Pb and Br atoms. 展开更多
关键词 x-ray scintillator x-ray illumination Computed tomography CsPbBr_(3)-based film perovskite Solution-processable semiconductor
在线阅读 下载PDF
Investigation of noise properties in grating-based x-ray phase tomography with reverse projection method
10
作者 鲍园 王研 +3 位作者 高昆 王志立 朱佩平 吴自玉 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第10期622-628,共7页
The relationship between noise variance and spatial resolution in grating-based x-ray phase computed tomography(PCT) imaging is investigated with reverse projection extraction method, and the noise variances of the ... The relationship between noise variance and spatial resolution in grating-based x-ray phase computed tomography(PCT) imaging is investigated with reverse projection extraction method, and the noise variances of the reconstructed absorption coefficient and refractive index decrement are compared. For the differential phase contrast method, the noise variance in the differential projection images follows the same inverse-square law with spatial resolution as in conventional absorption-based x-ray imaging projections. However, both theoretical analysis and simulations demonstrate that in PCT the noise variance of the reconstructed refractive index decrement scales with spatial resolution follows an inverse linear relationship at fixed slice thickness, while the noise variance of the reconstructed absorption coefficient conforms with the inverse cubic law. The results indicate that, for the same noise variance level, PCT imaging may enable higher spatial resolution than conventional absorption computed tomography(ACT), while ACT benefits more from degraded spatial resolution. This could be a useful guidance in imaging the inner structure of the sample in higher spatial resolution. 展开更多
关键词 x-ray imaging noise variance spatial resolution computed tomography (CT)
在线阅读 下载PDF
Soft X-ray Tomography and Sawtooth Oscillations during IBW in HT-7 Tokamak
11
作者 阮怀林 万宝年 +1 位作者 鲍抑 胡立群 《Plasma Science and Technology》 SCIE EI CAS CSCD 2001年第4期851-858,共8页
Tomographic reconstructions of soft x-ray emissivity in the HT-7 tokamak have been obtained using 86 miniature soft-x-ray detectors. Because there are two-detector arrays which are distributed in horizontal and vertic... Tomographic reconstructions of soft x-ray emissivity in the HT-7 tokamak have been obtained using 86 miniature soft-x-ray detectors. Because there are two-detector arrays which are distributed in horizontal and vertical directions on one poloidal plane, two-dimensional images of x-ray emissivity are obtained without having resort to a rotational model. The algorithm of Fourier-Bessel expansion was employed. The data analysed so far have been used principally to study MHD instabilities, and the illustrative examples of the sawtooth crash in IBW-heated plasma are described. 展开更多
关键词 Soft x-ray tomography and Sawtooth Oscillations during IBW in HT-7 Tokamak HT MODE
在线阅读 下载PDF
NON-INVASIVE IMAGING OF CORONARY ARTERY WITH 16-SLICE SPIRAL COMPUTED TOMOGRAPHY 被引量:6
12
作者 Zhu-huaZhang Zheng-yuJin +14 位作者 Dong-jingLi Song-baiLin Shu-yangZhang Ling-yanKong YunWang Lin-huiWang Wen-minZhao Wen-binMou Li-RenZhang Wen-lingZhu ChaoNi HuaRen Hong-quanYu QiMiao QiFang 《Chinese Medical Sciences Journal》 CAS CSCD 2004年第3期174-179,共6页
To evaluate the value of 16-slice spiral CT in the demonstration of coronary artery and in the diagnose of coronary artery stenosis. Methods Plain and enhanced CT scans were performed with a 16-slice CT scanner (Sensa... To evaluate the value of 16-slice spiral CT in the demonstration of coronary artery and in the diagnose of coronary artery stenosis. Methods Plain and enhanced CT scans were performed with a 16-slice CT scanner (Sensation 16, Siemens, Germany) in 230 patients with suspected coronary heart disease (CHD). Parameters of the plain scan were: 120 kV, 133 mA, slice col-limation 16 mm×1.5 mm, rotation time 0.42 seconds, increment 1.5 mm, and slice width 3 mm. Parameters of the enhanced scan were: 120 kV, 500 mA, slice collimation 16 mm×0.75 mm, rotation time 0.42 seconds, increment 0.5 mm, and slice width 1 mm. Enhanced CT scan was performed with a rapid intravenous injection of 100 mL iothalamate meglumine (Ultravist) (370 mgI/mL) or Omnipaque (350 mgI/mL) and 30 mL 0.9% NaCl chaser bolus at a flow rate of 3.5 mL/s. Calcium scoring with plain scan images and two and three dimensional reconstruction with enhanced scan images were made in all cases, among which 30 cases underwent conventional coronary angiography. Demonstration of coronary arteries and their stenosis were evaluated and the factors that might influence the image quality were analyzed. Results Coronary calcium scores were calculated and coronary artery was demonstrated in our study. In the evaluationof image quality with volume rendering technique (VRT) images, 78.3% of the images were of the first class, 12.2% the sec-ond class, and 9.6% the third class. Multi-planar reconstruction (MPR) and maximal intensity projection (MIP) were better than VRT in the demonstration of small branches. The image quality was related to the heart rate, with or without arrhythmia, and breath-hold ability of patients. Comparative study of the stenosis of coronary arteries in 30 cases showed that the sensi-tivity and specificity of 16-slice coronary CT angiography (CTA) to diagnose significant stenosis were 95.8% and 94.8% resp-ectively. Conclusion As a non-invasive and quick method, 16-slice coronary CTA is sensitive and specific to diagnose the stenosis of coronary arteries and can be used as a screening method in the diagnosis of CHD. 展开更多
关键词 ANGIOGRAPHY tomography x-ray computed coronary artery
在线阅读 下载PDF
Three-dimensional visualization of soil pore structure using computed tomography 被引量:1
13
作者 Qiaoling Han Xibo Zhou +2 位作者 Lei Liu Yandong Zhao Yue Zhao 《Journal of Forestry Research》 SCIE CAS CSCD 2019年第3期1053-1061,共9页
The geometric and spatial characteristics of pore structures determine the permeability and water retention of soils, which have important effects on soil functional diversity and ecological restoration. Until recentl... The geometric and spatial characteristics of pore structures determine the permeability and water retention of soils, which have important effects on soil functional diversity and ecological restoration. Until recently, there have not been tools and methods to visually and quantitatively describe the characteristics of soil pores. To solve this problem, this research reconstructs the geometry and spatial distribution of soil pores by the marching cubes method, texture mapping method and the ray casting method widely used in literature. The objectives were to explore an optimal method for three-dimensional visualization of soil pore structure by comparing the robustness of the three methods on soil CT images with single pore structure and porosity ranging from low (2–5%) to high (12–18%), and to evaluate the reconstruction performance of the three methods with different geometric features. The results demonstrate that there are aliases (jagged edges) and deficiency at the boundaries of the model reconstructed by the marching cubes method and pore volumes are smaller than the ground truth, whereas the results of the texture mapping method lack the details of pore structures. For all the soil images, the ray casting method is preferable since it better preserves the pore characteristics of the ground truth. Furthermore, the ray casting method produced the best soil pore model with higher rendering speed and lower memory consumption. Therefore, the ray casting method provides a more advanced method for visualization of pore structures and provides an optional technique for the study of the transport of moisture and the exchange of air in soil. 展开更多
关键词 Soil PORE STRUCTURE x-ray COMPUTED tomography Three-dimensional reconstruction PORE VISUALIZATION
在线阅读 下载PDF
Cosine fitting radiography and computed tomography
14
作者 李盼云 张凯 +5 位作者 黄万霞 袁清习 王研 鞠在强 吴自玉 朱佩平 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第6期679-686,共8页
A new method in diffraction-enhanced imaging computed tomography (DEI-CT) that follows the idea developed by Chapman et al. [Chapman D, Thomlinson W, Johnston R E, Washburn D, Pisano E, Gmur N, Zhong Z, Menk R, Arfe... A new method in diffraction-enhanced imaging computed tomography (DEI-CT) that follows the idea developed by Chapman et al. [Chapman D, Thomlinson W, Johnston R E, Washburn D, Pisano E, Gmur N, Zhong Z, Menk R, Arfelli F and Sayers D 1997 Phys. Med. BioL 42 2015] in 1997 is proposed in this paper. Merged with a "reverse projections" algorithm, only two sets of projection datasets at two defined orientations of the analyzer crystal are needed to reconstruct the linear absorption coefficient, the decrement of the real part of the refractive index and the linear scattering coefficient of the sample. Not only does this method reduce the delivered dose to the sample without degrading the image quality, but, compared with the existing DEI-CT approaches, it simplifies data-acquisition procedures. Experimental results confirm the reliability of this new method for DEI-CT applications. 展开更多
关键词 x-ray imaging diffraction-enhanced imaging phase contrast computed tomography
在线阅读 下载PDF
Soft x-ray tomographic reconstruction of Heliotron J plasma for the study of magnetohydrodynamic equilibrium and stability
15
作者 S PUROHIT Y SUZUKI +1 位作者 S OHDACHI S YAMAMOTO 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第6期72-78,共7页
The preparation for an experimental soft x-ray tomography study on the Heliotron J (H-J) machine is carried out,with the objectives of evaluating the capability of the current soft x-ray tomographic system in terms of... The preparation for an experimental soft x-ray tomography study on the Heliotron J (H-J) machine is carried out,with the objectives of evaluating the capability of the current soft x-ray tomographic system in terms of the identification of different mode structures and their poloidal rotation,and the axis shift with different plasma and machine parameters,and fixing the physics goals for the experimental study.These preparations were carried out via a simulated soft x-ray data set arising from different plasma conditions,such as magnetic islands,low beta and high beta.Soft x-ray tomography (SXT) is performed by the discrete pixel method including singular value decomposition and Phillips-Tikhonov regularization,to obtain clear and smooth images.The H-J soft x-ray tomography results from simulated soft x-rays for the equilibrium H-J plasma sensed the magnetic axis shift clearly and an estimate was also achieved.Successful reconstruction for mode structure m =1/n =1 was obtained along with the realization of the poloidal rotation of the structure.The reconstruction for the m =2/n =1 mode was not very clear for the current soft x-ray diagnostic design.Effective mode identification was not possible due to the lack of measurements.The SXT from the current soft x-ray diagnostic on H-J,the magnetic axis shift can be estimated and the m =1/n =1 mode can be studied.Study of higher poloidal modes is difficult with the current design. 展开更多
关键词 HELIOTRON J tomography SOFT x-ray MAGNETOHYDRODYNAMICS
在线阅读 下载PDF
Insights into the hydrogen evolution reaction in vanadium redox flow batteries:A synchrotron radiation based X-ray imaging study
16
作者 Kerstin Köble Alexey Ershov +7 位作者 Kangjun Duan Monja Schilling Alexander Rampf Angelica Cecilia TomášFaragó Marcus Zuber Tilo Baumbach Roswitha Zeis 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第4期132-144,共13页
The parasitic hydrogen evolution reaction(HER)in the negative half-cell of vanadium redox flow batteries(VRFBs)causes severe efficiency losses.Thus,a deeper understanding of this process and the accompanying bubble fo... The parasitic hydrogen evolution reaction(HER)in the negative half-cell of vanadium redox flow batteries(VRFBs)causes severe efficiency losses.Thus,a deeper understanding of this process and the accompanying bubble formation is crucial.This benchmarking study locally analyzes the bubble distribution in thick,porous electrodes for the first time using deep learning-based image segmentation of synchrotron X-ray micro-tomograms.Each large three-dimensional data set was processed precisely in less than one minute while minimizing human errors and pointing out areas of increased HER activity in VRFBs.The study systematically varies the electrode potential and material,concluding that more negative electrode potentials of-200 m V vs.reversible hydrogen electrode(RHE)and lower cause more substantial bubble formation,resulting in bubble fractions of around 15%–20%in carbon felt electrodes.Contrarily,the bubble fractions stay only around 2%in an electrode combining carbon felt and carbon paper.The detected areas with high HER activity,such as the border subregion with more than 30%bubble fraction in carbon felt electrodes,the cutting edges,and preferential spots in the electrode bulk,are potential-independent and suggest that larger electrodes with a higher bulk-to-border ratio might reduce HER-related performance losses.The described combination of electrochemical measurements,local X-ray microtomography,AI-based segmentation,and 3D morphometric analysis is a powerful and novel approach for local bubble analysis in three-dimensional porous electrodes,providing an essential toolkit for a broad community working on bubble-generating electrochemical systems. 展开更多
关键词 Vanadium redox flow battery Synchrotron x-ray imaging tomography Hydrogen evolution reaction Gas bubbles Deep learning
在线阅读 下载PDF
Penetrating view of nano-structures in Aleochara verna spermatheca and flagellum by hard X-ray microscopy 被引量:2
17
作者 张凯 李德娥 +6 位作者 洪友丽 朱佩平 袁清习 黄万霞 高昆 周红章 吴自玉 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第7期410-414,共5页
A penetrating view of the three-dimensional nanostructure of female spermatheca and male flagellum in the species Aleochara verna is obtained with 100-nm resolution using a hard X-ray microscope, which provides a fast... A penetrating view of the three-dimensional nanostructure of female spermatheca and male flagellum in the species Aleochara verna is obtained with 100-nm resolution using a hard X-ray microscope, which provides a fast noninvasive imaging technology for insect morphology. Through introducing Zernike phase contrast and heavy metal staining, images taken at 8 keV displayed sufficient contrast for observing nanoscale fine structures, such as the spermatheca cochleate duct and the subapex of the flagellum, which have some implications for the study of the sperm transfer process and genital evolution in insects. This work shows that both the spatial resolution and the contrast characteristic of hard X-ray microscopy are quite promising for insect morphology studies and, particularly, provide an attractive alternative to the destructive techniques used for investigating internal soft tissues. 展开更多
关键词 x-ray microscopy computed tomography synchrotron radiation source morphology
在线阅读 下载PDF
Tomographic analysis of the central magnetohydrodynamic oscillations on the HT-7 tokamak 被引量:2
18
作者 马天鹏 阮怀林 +9 位作者 胡立群 万宝年 高翔 甄香君 周立武 孙有文 高伟 陈忠勇 林士耀 孔伟 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第3期593-599,共7页
Multi-channel soft x-ray (SX) detectors are applied to generate images of magnetohydrodynamic (MHD) oscillation on the HT-7 tokamak, and the data from SX cameras are analysed by using the Fourier-Bessel harmonic r... Multi-channel soft x-ray (SX) detectors are applied to generate images of magnetohydrodynamic (MHD) oscillation on the HT-7 tokamak, and the data from SX cameras are analysed by using the Fourier-Bessel harmonic reconstruction method and the singular value decomposition. The image reconstruction of SX emissivity is obtained on the assumption of plasma rigid rotation, One of the important phenomena in the HT-7 discharge is the transition from the sawtooth oscillations to the MHD oscillations when the plasma density grows higher. The MHD structure observed in the SX tomography is featured as follows: the magnetic surface of MHD structure is made up of the crescent-shaped "hot core" and the circular "cold bubble". The structure of the magnetic surface is relatively stable. It rotates in the direction of the electron diamagnetic drift at a frequency being the oscillation frequency of the MHD oscillations. 展开更多
关键词 soft x-ray tomography magnetohydrodynamic oscillation singular value decomposition
在线阅读 下载PDF
Application of Computed Tomographic Colonography in Diagnosis of Colonic Polyps 被引量:1
19
作者 Ming-wei Qin Wei-dong Pan Guan-ning Cong Yun Wang Yun-qing Zhang Ji-xiang Liang 《Chinese Medical Sciences Journal》 CAS CSCD 2009年第1期36-40,共5页
Objective To assess the clinical values of computed tomographic colonography (CTC) in diagnosis of colonic polyps. Methods Forty-two patients who were clinically suspicious of colonic polyps or underwent colonic po... Objective To assess the clinical values of computed tomographic colonography (CTC) in diagnosis of colonic polyps. Methods Forty-two patients who were clinically suspicious of colonic polyps or underwent colonic polyps screening received examinations with both CTC and conventional colonoscopy. Sixteen- or 64-slice spiral computed tomography and professional imaging processing techniques were used for evaluation. Per-polyp and per-patient results were analyzed. Those by per-polyp were subsequently divided into ≥10 mm group, 5-10 mm group, and ≤5 mm group. Sensitivity, positive predictive value (PPV), specificity, negative predictive value (NPV), and accuracy were calculated using statistical method for diagnostic studies, with conventional colonoscopy as a gold standard. Results Ninety and 61 polyps were found by CTC and conventional colonoscopy, respectively. The per-polyp sensitivity/PPV were 80.3%/55.6% in total, and 100%/92.9%, 93.8%/65.2%, and 68.8%/ 41.5% in the ≥10 mm group, 5-10 mm group, and ≤5 turn group, respectively. The per-patient sensitivity, PPV, specificity, NPV, and accuracy were 97.1%, 89.5%, 42.9%, 75.0%, and 88.1%, respectively. Conclusion CTC can clearly reveal the morphology of colonic polyps and be used as a routine monitoring method for the clinical diagnosis of polyps. 展开更多
关键词 colonic polyp x-ray computed tomography COLONOSCOPY
在线阅读 下载PDF
New tomographic reconstruction technique based on Laplacian eigenfunction
20
作者 Yasuhiro SUZUKI Shishir PUROHIT +2 位作者 Satoshi OHDACHI Satoshi YAMAMOTO Kazunobu NAGASAKI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2020年第10期5-9,共5页
This letter proposes a new tomographic reconstruction procedure based on the Laplacian eigenfunction(LEF) patterns, which are independent of the plasma cross-section and do not require the flux surface information. Th... This letter proposes a new tomographic reconstruction procedure based on the Laplacian eigenfunction(LEF) patterns, which are independent of the plasma cross-section and do not require the flux surface information. The process is benchmarked for the experimental data of Heliotron J plasma and the results are compared with the least-squares approximation by a Phillips–Tikhonov(PT)-type regularization, which is widely used as the standard technique for tomographic reconstruction. The reconstruction based on the LEF is found to be capable of determining the magnetic axis at different time locations efficiently in comparison with the PT-type regularization. 展开更多
关键词 tomography Laplacian eigenfunction Heliotron J soft x-ray
在线阅读 下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部