We report here the observation result of joint observation of long period tremor signals with broadband seismome-ter,tiltmeter and gravimeter at the HUST(Huazhong University of Science and Technology)station.The obser...We report here the observation result of joint observation of long period tremor signals with broadband seismome-ter,tiltmeter and gravimeter at the HUST(Huazhong University of Science and Technology)station.The observed data were compared and analyzed.Since 2005,the several tens of abnormal tremor signals which are weak,com-plex and duration of 2 to 3 days have been synchronously recorded by the different instruments.The tremor signals have the periodic domain in the range of 3 to 5 minutes,20 to 30 minutes and even more than 1 hour.The observa-tion shows such tremors are a physical existence.The analysis indicates that a part of the tremors caused by the typhoon from the western Pacific Ocean.These tremors have a close relationship with wind velocity of typhoon and distance between the typhoon center and the station.Except these,the cause of others is still unclear.展开更多
The effect of external vibration on the velocity uniformity of the moving mechanism of the angular mir⁃ror translational Fourier transform interferometer(hereinafter referred to as interferometer)can be quantitatively...The effect of external vibration on the velocity uniformity of the moving mechanism of the angular mir⁃ror translational Fourier transform interferometer(hereinafter referred to as interferometer)can be quantitatively analysed by the interferometer optical range difference velocity stability.The article proposes a more comprehen⁃sive method of analysing the optical range difference velocity uniformity for the reliability of the interferometer ki⁃nematic mechanism under the influence of on-orbit microvibration in the process of space spectroscopy detection.The method incorporates the structural response of the interferometer caused by external excitation into the stabili⁃ty analysis as one of the influencing factors,so as to reflect the reliability of the interferometer in orbit more realis⁃tically,and judge the microvibration criticality that the interferometer can withstand more accurately.At the same time,an optical surface model of the interferometer is established to further theoretically characterise the effect of microvibration on the homogeneity of the interferometric mechanism.The method discussed in the article pro⁃vides a way of thinking for the judgement of the reliability of the mechanism movement under the external excita⁃tion perturbation as well as the research on the optimisation of the mechanism control.展开更多
文摘We report here the observation result of joint observation of long period tremor signals with broadband seismome-ter,tiltmeter and gravimeter at the HUST(Huazhong University of Science and Technology)station.The observed data were compared and analyzed.Since 2005,the several tens of abnormal tremor signals which are weak,com-plex and duration of 2 to 3 days have been synchronously recorded by the different instruments.The tremor signals have the periodic domain in the range of 3 to 5 minutes,20 to 30 minutes and even more than 1 hour.The observa-tion shows such tremors are a physical existence.The analysis indicates that a part of the tremors caused by the typhoon from the western Pacific Ocean.These tremors have a close relationship with wind velocity of typhoon and distance between the typhoon center and the station.Except these,the cause of others is still unclear.
文摘The effect of external vibration on the velocity uniformity of the moving mechanism of the angular mir⁃ror translational Fourier transform interferometer(hereinafter referred to as interferometer)can be quantitatively analysed by the interferometer optical range difference velocity stability.The article proposes a more comprehen⁃sive method of analysing the optical range difference velocity uniformity for the reliability of the interferometer ki⁃nematic mechanism under the influence of on-orbit microvibration in the process of space spectroscopy detection.The method incorporates the structural response of the interferometer caused by external excitation into the stabili⁃ty analysis as one of the influencing factors,so as to reflect the reliability of the interferometer in orbit more realis⁃tically,and judge the microvibration criticality that the interferometer can withstand more accurately.At the same time,an optical surface model of the interferometer is established to further theoretically characterise the effect of microvibration on the homogeneity of the interferometric mechanism.The method discussed in the article pro⁃vides a way of thinking for the judgement of the reliability of the mechanism movement under the external excita⁃tion perturbation as well as the research on the optimisation of the mechanism control.