Grating-based x-ray phase contrast imaging has the potential to be applied in future medical applications as it is compatible with both laboratory and synchrotron source. However, information retrieval methods are imp...Grating-based x-ray phase contrast imaging has the potential to be applied in future medical applications as it is compatible with both laboratory and synchrotron source. However, information retrieval methods are important because acquisition speed, scanning mode, image quality, and radiation dose depend on them. Phase-stepping (PS) is a widely used method to retrieve information, while angular signal radiography (ASR) is a newly established method. In this manuscript, signal-to-noise ratios (SNRs) of ASR are compared with that of PS. Numerical experiments are performed to validate theoretical results. SNRs comparison shows that for refraction and scattering images ASR has higher SNR than PS method, while for absorption image both methods have same SNR. Therefore, our conclusions would have guideline in future preclinical and clinical applications.展开更多
An signal noise ratio( SNR) adaptive sorting algorithm using the time-frequency( TF)sparsity of frequency-hopping( FH) signal is proposed in this paper. Firstly,the Gabor transformation is used as TF transformat...An signal noise ratio( SNR) adaptive sorting algorithm using the time-frequency( TF)sparsity of frequency-hopping( FH) signal is proposed in this paper. Firstly,the Gabor transformation is used as TF transformation in the system and a sorting model is established under undetermined condition; then the SNR adaptive pivot threshold setting method is used to find the TF single source. The mixed matrix is estimated according to the TF matrix of single source. Lastly,signal sorting is realized through improved subspace projection combined with relative power deviation of source. Theoretical analysis and simulation results showthat this algorithm has good effectiveness and performance.展开更多
Stochastic resonance (SR) has been proved to be an effective approach to extract weak signals overwhelmed in noise. However, the detection effect of current SR models is still unsatisfactory. Here, a coupled tri-sta...Stochastic resonance (SR) has been proved to be an effective approach to extract weak signals overwhelmed in noise. However, the detection effect of current SR models is still unsatisfactory. Here, a coupled tri-stable stochastic resonance (CTSSR) model is proposed to further increase the output signal-to-noise ratio (SNR) and improve the detection effect of SR. The effects of parameters a, b, c, and r in the proposed resonance system on the SNR are studied, by which we determine a set of parameters that is relatively optimal to implement a comparison with other classical SR models. Numerical experiment results indicate that this proposed model performs better in weak signal detection applications than the classical ones with merits of higher output SNR and better anti-noise capability.展开更多
Signal-to-noise ratio(SNR)estimation for signal which can be modeled by Auto-regressive(AR)process is studied in this paper.First,the conventional frequency domain method is introduced to estimate the SNR for the ...Signal-to-noise ratio(SNR)estimation for signal which can be modeled by Auto-regressive(AR)process is studied in this paper.First,the conventional frequency domain method is introduced to estimate the SNR for the received signal in additive white Gauss noise(AWGN)channel.Then a parametric SNR estimation algorithm is proposed by taking advantage of the AR model information of the received signal.The simulation results show that the proposed parametric method has better performance than the conventional frequency doma in method in case of AWGN channel.展开更多
为了提高导航卫星反射信号信噪比,提出了一种基于块平均预处理(BAP)的反射信号处理方法,该方法首先以伪码周期为块尺寸对接收信号进行分块,并对各分块进行叠加、平均,然后对平均后的信号进行相关处理.在此基础上,理论分析了块平均预处...为了提高导航卫星反射信号信噪比,提出了一种基于块平均预处理(BAP)的反射信号处理方法,该方法首先以伪码周期为块尺寸对接收信号进行分块,并对各分块进行叠加、平均,然后对平均后的信号进行相关处理.在此基础上,理论分析了块平均预处理对导航反射信号的影响,推导了镜面反射点反射信号处理增益的数学表达式,以及相关处理后得到的一维相关功率,对比分析了该方法与传统处理方法的计算复杂度,分析表明该方法对反射信号具有空域滤波效果,提高了镜面反射点反射信号的信噪比且有效降低了计算复杂度.最后,基于块平均预处理的软件接收机被开发,并对课题组实采的岸基GPS数据进行了处理,结果表明:与未块平均预处理的传统方法相比,在块平均预处理时间为2、5、10、15以及20 ms时,该方法所得相关功率的峰值信噪比分别提高了约3.5、6.7、10.2、10.6和10.4 d B,且在块平均预处理时间为10 ms时,处理等长数据的时间缩短了近2.2倍.展开更多
通过考察电极长度及电极间距、检测管管径及材质、激励信号频率、电压和波形等参数对信噪比的影响,研制了一种适用于常规型离子色谱系统的电容耦合非接触式电导检测器(C^4D)。在抑制模式下,该检测器对常见无机阴离子(F^-、Cl^-、NO_2^-...通过考察电极长度及电极间距、检测管管径及材质、激励信号频率、电压和波形等参数对信噪比的影响,研制了一种适用于常规型离子色谱系统的电容耦合非接触式电导检测器(C^4D)。在抑制模式下,该检测器对常见无机阴离子(F^-、Cl^-、NO_2^-、Br^-、NO_3^-和SO_4^(2-))的检出限(信噪比=3)为0.02~0.08μmol/L;峰面积的相对标准偏差<1.8%(n=6);在0.1~10μm o l/L范围内上述6种无机阴离子线性关系良好,相关系数(R^2)>0.999。自制C4D的主要性能参数与商品化接触式电导检测器相当。该检测器具有结构简单、成本低廉、无电极污染等优点,有利于拓展离子色谱的应用范围。展开更多
Improvement of measurement precision and repeatability is one of the issues currently faced by the laser-induced breakdown spectroscopy (LIBS) technique, which is expected to be capable of precise and accurate quant...Improvement of measurement precision and repeatability is one of the issues currently faced by the laser-induced breakdown spectroscopy (LIBS) technique, which is expected to be capable of precise and accurate quantitative analysis. It was found that there was great potential to improve the signal quality and repeatability by reducing the laser beam divergence angle using a suitable beam expander (BE). In the present work, the influences of several experimental parameters for the case with BE are studied in order to optimize the analytical performances: the signal to noise ratio (SNR) and the relative standard deviation (RSD). We demonstrate that by selecting the optimal experimental parameters, the BE-included LIBS setup can give higher SNR and lower RSD values of the line intensity normalized by the whole spectrum area. For validation purposes, support vector machine (SVM) regression combined with principal component analysis (PCA) was used to establish a calibration model to realize the quantitative analysis of the ash content. Good agreement has been found between the laboratory measurement results from the LIBS method and those from the traditional method. The measurement accuracy presented here for ash content analysis is estimated to be 0.31%, while the average relative error is 2.36%.展开更多
基金Project supported by the National Research and Development Project for Key Scientific Instruments(Grant No.CZBZDYZ20140002)the National Natural Science Foundation of China(Grant Nos.11535015,11305173,and 11375225)+2 种基金the project supported by Institute of High Energy Physics,Chinese Academy of Sciences(Grant No.Y4545320Y2)the Fundamental Research Funds for the Central Universities(Grant No.WK2310000065)Wali Faiz,acknowledges and wishes to thank the Chinese Academy of Sciences and The World Academy of Sciences(CAS-TWAS)President’s Fellowship Program for generous financial support
文摘Grating-based x-ray phase contrast imaging has the potential to be applied in future medical applications as it is compatible with both laboratory and synchrotron source. However, information retrieval methods are important because acquisition speed, scanning mode, image quality, and radiation dose depend on them. Phase-stepping (PS) is a widely used method to retrieve information, while angular signal radiography (ASR) is a newly established method. In this manuscript, signal-to-noise ratios (SNRs) of ASR are compared with that of PS. Numerical experiments are performed to validate theoretical results. SNRs comparison shows that for refraction and scattering images ASR has higher SNR than PS method, while for absorption image both methods have same SNR. Therefore, our conclusions would have guideline in future preclinical and clinical applications.
基金Supported by the National Natural Science Foundation of China(64601500)
文摘An signal noise ratio( SNR) adaptive sorting algorithm using the time-frequency( TF)sparsity of frequency-hopping( FH) signal is proposed in this paper. Firstly,the Gabor transformation is used as TF transformation in the system and a sorting model is established under undetermined condition; then the SNR adaptive pivot threshold setting method is used to find the TF single source. The mixed matrix is estimated according to the TF matrix of single source. Lastly,signal sorting is realized through improved subspace projection combined with relative power deviation of source. Theoretical analysis and simulation results showthat this algorithm has good effectiveness and performance.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.61071025 and 61502538)
文摘Stochastic resonance (SR) has been proved to be an effective approach to extract weak signals overwhelmed in noise. However, the detection effect of current SR models is still unsatisfactory. Here, a coupled tri-stable stochastic resonance (CTSSR) model is proposed to further increase the output signal-to-noise ratio (SNR) and improve the detection effect of SR. The effects of parameters a, b, c, and r in the proposed resonance system on the SNR are studied, by which we determine a set of parameters that is relatively optimal to implement a comparison with other classical SR models. Numerical experiment results indicate that this proposed model performs better in weak signal detection applications than the classical ones with merits of higher output SNR and better anti-noise capability.
基金supported by the National Natural Science Foundation of China under Grant No. 60372022Program for New Century Excellent Talentsin University under Grant No. NCET-05-0806
文摘Signal-to-noise ratio(SNR)estimation for signal which can be modeled by Auto-regressive(AR)process is studied in this paper.First,the conventional frequency domain method is introduced to estimate the SNR for the received signal in additive white Gauss noise(AWGN)channel.Then a parametric SNR estimation algorithm is proposed by taking advantage of the AR model information of the received signal.The simulation results show that the proposed parametric method has better performance than the conventional frequency doma in method in case of AWGN channel.
文摘为了提高导航卫星反射信号信噪比,提出了一种基于块平均预处理(BAP)的反射信号处理方法,该方法首先以伪码周期为块尺寸对接收信号进行分块,并对各分块进行叠加、平均,然后对平均后的信号进行相关处理.在此基础上,理论分析了块平均预处理对导航反射信号的影响,推导了镜面反射点反射信号处理增益的数学表达式,以及相关处理后得到的一维相关功率,对比分析了该方法与传统处理方法的计算复杂度,分析表明该方法对反射信号具有空域滤波效果,提高了镜面反射点反射信号的信噪比且有效降低了计算复杂度.最后,基于块平均预处理的软件接收机被开发,并对课题组实采的岸基GPS数据进行了处理,结果表明:与未块平均预处理的传统方法相比,在块平均预处理时间为2、5、10、15以及20 ms时,该方法所得相关功率的峰值信噪比分别提高了约3.5、6.7、10.2、10.6和10.4 d B,且在块平均预处理时间为10 ms时,处理等长数据的时间缩短了近2.2倍.
文摘通过考察电极长度及电极间距、检测管管径及材质、激励信号频率、电压和波形等参数对信噪比的影响,研制了一种适用于常规型离子色谱系统的电容耦合非接触式电导检测器(C^4D)。在抑制模式下,该检测器对常见无机阴离子(F^-、Cl^-、NO_2^-、Br^-、NO_3^-和SO_4^(2-))的检出限(信噪比=3)为0.02~0.08μmol/L;峰面积的相对标准偏差<1.8%(n=6);在0.1~10μm o l/L范围内上述6种无机阴离子线性关系良好,相关系数(R^2)>0.999。自制C4D的主要性能参数与商品化接触式电导检测器相当。该检测器具有结构简单、成本低廉、无电极污染等优点,有利于拓展离子色谱的应用范围。
基金supported by the 973 Program of China(No.2012CB921603)National Natural Science Foundation of China(Nos.61475093,61127017,61178009,61108030,61378047,61275213,61475093,and 61205216)+3 种基金the National Key Technology R&D Program of China(No.2013BAC14B01)the Shanxi Natural Science Foundation(Nos.2013021004-1 and 2012021022-1)the Shanxi Scholarship Council of China(Nos.2013-011 and 2013-01)the Program for the Outstanding Innovative Teams of Higher Learning Institutions of Shanxi,China
文摘Improvement of measurement precision and repeatability is one of the issues currently faced by the laser-induced breakdown spectroscopy (LIBS) technique, which is expected to be capable of precise and accurate quantitative analysis. It was found that there was great potential to improve the signal quality and repeatability by reducing the laser beam divergence angle using a suitable beam expander (BE). In the present work, the influences of several experimental parameters for the case with BE are studied in order to optimize the analytical performances: the signal to noise ratio (SNR) and the relative standard deviation (RSD). We demonstrate that by selecting the optimal experimental parameters, the BE-included LIBS setup can give higher SNR and lower RSD values of the line intensity normalized by the whole spectrum area. For validation purposes, support vector machine (SVM) regression combined with principal component analysis (PCA) was used to establish a calibration model to realize the quantitative analysis of the ash content. Good agreement has been found between the laboratory measurement results from the LIBS method and those from the traditional method. The measurement accuracy presented here for ash content analysis is estimated to be 0.31%, while the average relative error is 2.36%.