A multiplexed white light interferometric fiber optic twin-sensor-array was designed to monitor the structural health of large buildings.In this sensing system,based on a Michelson interferometer,an optical path match...A multiplexed white light interferometric fiber optic twin-sensor-array was designed to monitor the structural health of large buildings.In this sensing system,based on a Michelson interferometer,an optical path matching technique is used to demodulate each twin-sensor.Each twin-sensor-array consists of a 2×N sensing element linked by a 3 dB coupler.When one of the twin-sensor is used to measure strain,variations caused by temperature can be compensated for by referencing the other twin-sensor.The multiplexing capacity of the sensing scheme has been analyzed and experimental results with a 2×3 twin-sensor-array are given.展开更多
The Allan variance analysis method is used to identify the stochastic noise in the stray current sensor. The stray current characteristic is firstly introduced. Then the optical configuration and the signal processing...The Allan variance analysis method is used to identify the stochastic noise in the stray current sensor. The stray current characteristic is firstly introduced. Then the optical configuration and the signal processing method of the stray current sensor are illustrated. Moreover, the cause of the stochastic noise in the stray current sensor is analyzed. The calculation method of the stochastic noise coefficient is presented in detail. And the feasibility of the stochastic noise identification with the Allan variance analysis method is evaluated. Furthermore, the zero-drift signal acquisition experiment is conducted to identify the stochastic noise in the stray current sensor. According to the experimental result, the bias instability noise, the quantization noise and the white noise are identified as the major stochastic noise. Finally, the experiment on the direct-current signal acquisitions is conducted, whose results indicate that the signal drift of the measured direct-current is mainly caused by the major stochastic noise. And the suppression methods of the major stochastic noise are proposed.展开更多
基金National Natural Science Foundation of China(60577005)Specialized Research Fund for the Doctoral Program of Higher Education Institute of MOE,China,to Harbin Engineering University
文摘A multiplexed white light interferometric fiber optic twin-sensor-array was designed to monitor the structural health of large buildings.In this sensing system,based on a Michelson interferometer,an optical path matching technique is used to demodulate each twin-sensor.Each twin-sensor-array consists of a 2×N sensing element linked by a 3 dB coupler.When one of the twin-sensor is used to measure strain,variations caused by temperature can be compensated for by referencing the other twin-sensor.The multiplexing capacity of the sensing scheme has been analyzed and experimental results with a 2×3 twin-sensor-array are given.
基金Project(2017QNA13)supported by Fundamental Research Funds for the Central Universities,ChinaProject(PAPD)supported by Priority Academic Program Development of Jiangsu Higher Education Institutions,China
文摘The Allan variance analysis method is used to identify the stochastic noise in the stray current sensor. The stray current characteristic is firstly introduced. Then the optical configuration and the signal processing method of the stray current sensor are illustrated. Moreover, the cause of the stochastic noise in the stray current sensor is analyzed. The calculation method of the stochastic noise coefficient is presented in detail. And the feasibility of the stochastic noise identification with the Allan variance analysis method is evaluated. Furthermore, the zero-drift signal acquisition experiment is conducted to identify the stochastic noise in the stray current sensor. According to the experimental result, the bias instability noise, the quantization noise and the white noise are identified as the major stochastic noise. Finally, the experiment on the direct-current signal acquisitions is conducted, whose results indicate that the signal drift of the measured direct-current is mainly caused by the major stochastic noise. And the suppression methods of the major stochastic noise are proposed.