This paper proposed the reclosing method in distribution system with battery energy storage system(BESS)using wavelet transform(WT).The proposed method performs the WT of load current and then calculates the absolute ...This paper proposed the reclosing method in distribution system with battery energy storage system(BESS)using wavelet transform(WT).The proposed method performs the WT of load current and then calculates the absolute value of slope of detail coefficient.The mother wavelet used is db4of level6.The fault clearing is detected using the rapid increase of this value.After the detection of fault clearing,the reclosing is performed.To verify the proposed method,various simulations according to the fault clearing times,fault resistances,and fault lengths are performed using EMTP.The simulation results show that fault clearing can be detected using proposed absolute value of slope of detail coefficient and hence the reclosing can be performed successfully.展开更多
A new type of intelligent recolser controller installed on the outdoor rod is developed, which is mainly composed of microcontroller of Intel 87C196KC 20 and CPLD devices. This controller integrates all the functions ...A new type of intelligent recolser controller installed on the outdoor rod is developed, which is mainly composed of microcontroller of Intel 87C196KC 20 and CPLD devices. This controller integrates all the functions of measuring, controlling, protection, fault diagnosis, communication, remote controlled operation and self power devices with infra red remote control devices as a unit. The controller applies the distributed structure, field concentration line and intelligent technology to seal up the synthetic servomechanisms such as the microcomputer based protection and measuring devices in the second stage of the mini out door transformer substation, which are distributed on the outdoor circuit switches on the spot and formed as a whole. Therefore, this technology can transform a large number of ordinary homemade SF 6 circuit beaker and vacuum circuit breaker into intelligent circuit recloser, thus replacing the expensive imported automatic circuit recolser.展开更多
文摘This paper proposed the reclosing method in distribution system with battery energy storage system(BESS)using wavelet transform(WT).The proposed method performs the WT of load current and then calculates the absolute value of slope of detail coefficient.The mother wavelet used is db4of level6.The fault clearing is detected using the rapid increase of this value.After the detection of fault clearing,the reclosing is performed.To verify the proposed method,various simulations according to the fault clearing times,fault resistances,and fault lengths are performed using EMTP.The simulation results show that fault clearing can be detected using proposed absolute value of slope of detail coefficient and hence the reclosing can be performed successfully.
文摘A new type of intelligent recolser controller installed on the outdoor rod is developed, which is mainly composed of microcontroller of Intel 87C196KC 20 and CPLD devices. This controller integrates all the functions of measuring, controlling, protection, fault diagnosis, communication, remote controlled operation and self power devices with infra red remote control devices as a unit. The controller applies the distributed structure, field concentration line and intelligent technology to seal up the synthetic servomechanisms such as the microcomputer based protection and measuring devices in the second stage of the mini out door transformer substation, which are distributed on the outdoor circuit switches on the spot and formed as a whole. Therefore, this technology can transform a large number of ordinary homemade SF 6 circuit beaker and vacuum circuit breaker into intelligent circuit recloser, thus replacing the expensive imported automatic circuit recolser.