As an advanced 4^(th) generation synchrotron radiation facility,the Shenzhen Innovation Light-source Facility(SILF)storage ring is based on multi-bend achromat(MBA)lattices,enabling one to two orders of magnitude redu...As an advanced 4^(th) generation synchrotron radiation facility,the Shenzhen Innovation Light-source Facility(SILF)storage ring is based on multi-bend achromat(MBA)lattices,enabling one to two orders of magnitude reduction in beam emittance compared to the 3^(rd) generation storage ring.This significantly enhance the radiation brightness and coherence.The multipole magnets of many types for SILF storage ring are under preliminary design,which require high integral field homogeneity.As a result,a dedicated pole tip optimization procedure with high efficiency is developed for quadrupole and sextupole magnets with Opera-2D^(■)python script.The procedure considers also the 3D field effect which makes the optimization more straightforward.In this paper,the design of the quadrupole and sextupole magnets for SILF storage ring is first presented,followed by a detailed description of the implemented pole shape optimization method.展开更多
A new method was developed for the simultaneous analysis of 12 pesticide residues in onion and fennel by gas chromatography(GC)-triple quadrupole mass spectrometry(MS/MS)-electron impact ion source(EI)-select reaction...A new method was developed for the simultaneous analysis of 12 pesticide residues in onion and fennel by gas chromatography(GC)-triple quadrupole mass spectrometry(MS/MS)-electron impact ion source(EI)-select reaction monitoring mode(SRM).The 12 pesticide includes fungicide,acaricide,carbamate and plant growth regulator pesticide.The complicated matrix samples of onion and fennel were extracted by acetonitrile,cleaned up by solid phase extraction of Carb/PSA.By optimizing the GC-MS/MS-SRM parameters,the interference from clean-up procedure was further removed and 12 pesticide residues were determined accurately.The average recoveries for most pesticides(at the spiked level of 0.05-0.20 mg/kg) were between 114%-156%,the relative standard deviation(RSD) of the method was less than 20%,and the limit of detection were 0.5-5 μg/kg.展开更多
The international monitoring system (IMS) station transport noble gas sample is analyzed by quadrupole mass spectrometer. The sample is composed by absolute majority of xenon and nitrogen, therefore, it can be calcula...The international monitoring system (IMS) station transport noble gas sample is analyzed by quadrupole mass spectrometer. The sample is composed by absolute majority of xenon and nitrogen, therefore, it can be calculated by the method of equation of state of ideal gas (PTV). The relatively expanded uncertainty of the xenon quantity is 4.5% in 95% confidence level.展开更多
Using quadrupole mass spectrometer,calibration gas PFTBA was turned on in constant flow to get the signal intensity,and off to get the noise value.Different scan time and dwell time was used separately for full scan m...Using quadrupole mass spectrometer,calibration gas PFTBA was turned on in constant flow to get the signal intensity,and off to get the noise value.Different scan time and dwell time was used separately for full scan mode and SIM to find out the effect of scan rate on signal intensity and noise.展开更多
To find out the effect of scan rate on sensitivity in quadrupole mass spectrometer,DDV and 11 common hypnotic drugs were chosen for GC-MS analysis.Different scan time and dwell time was used separately for full scan m...To find out the effect of scan rate on sensitivity in quadrupole mass spectrometer,DDV and 11 common hypnotic drugs were chosen for GC-MS analysis.Different scan time and dwell time was used separately for full scan mode and SIM.Then charasteristic ions were extracted to calculate signal to noise values.展开更多
文摘As an advanced 4^(th) generation synchrotron radiation facility,the Shenzhen Innovation Light-source Facility(SILF)storage ring is based on multi-bend achromat(MBA)lattices,enabling one to two orders of magnitude reduction in beam emittance compared to the 3^(rd) generation storage ring.This significantly enhance the radiation brightness and coherence.The multipole magnets of many types for SILF storage ring are under preliminary design,which require high integral field homogeneity.As a result,a dedicated pole tip optimization procedure with high efficiency is developed for quadrupole and sextupole magnets with Opera-2D^(■)python script.The procedure considers also the 3D field effect which makes the optimization more straightforward.In this paper,the design of the quadrupole and sextupole magnets for SILF storage ring is first presented,followed by a detailed description of the implemented pole shape optimization method.
文摘A new method was developed for the simultaneous analysis of 12 pesticide residues in onion and fennel by gas chromatography(GC)-triple quadrupole mass spectrometry(MS/MS)-electron impact ion source(EI)-select reaction monitoring mode(SRM).The 12 pesticide includes fungicide,acaricide,carbamate and plant growth regulator pesticide.The complicated matrix samples of onion and fennel were extracted by acetonitrile,cleaned up by solid phase extraction of Carb/PSA.By optimizing the GC-MS/MS-SRM parameters,the interference from clean-up procedure was further removed and 12 pesticide residues were determined accurately.The average recoveries for most pesticides(at the spiked level of 0.05-0.20 mg/kg) were between 114%-156%,the relative standard deviation(RSD) of the method was less than 20%,and the limit of detection were 0.5-5 μg/kg.
文摘The international monitoring system (IMS) station transport noble gas sample is analyzed by quadrupole mass spectrometer. The sample is composed by absolute majority of xenon and nitrogen, therefore, it can be calculated by the method of equation of state of ideal gas (PTV). The relatively expanded uncertainty of the xenon quantity is 4.5% in 95% confidence level.
文摘Using quadrupole mass spectrometer,calibration gas PFTBA was turned on in constant flow to get the signal intensity,and off to get the noise value.Different scan time and dwell time was used separately for full scan mode and SIM to find out the effect of scan rate on signal intensity and noise.
文摘To find out the effect of scan rate on sensitivity in quadrupole mass spectrometer,DDV and 11 common hypnotic drugs were chosen for GC-MS analysis.Different scan time and dwell time was used separately for full scan mode and SIM.Then charasteristic ions were extracted to calculate signal to noise values.