In the printing industry,vacuum pumps play a critical role in sheet feeding and gripping processes.In order to improve the efficiency of vacuum pumps,By analyzing the internal flow field of the vane type vacuum pump,t...In the printing industry,vacuum pumps play a critical role in sheet feeding and gripping processes.In order to improve the efficiency of vacuum pumps,By analyzing the internal flow field of the vane type vacuum pump,the CFD method was used to simulate the internal flow field of the air pump,and it was found that a main vortex was formed near the rotor of the trailing blade.Based on this observation,a new rotor shape design was proposed in this study,which design places arc-shaped depressed on the circumference of the rotor where the main vortex forms.The existence of the depression facilitated forward motion of the main airflow and thus effectively restricting reverse flow.Simulation results demonstrated that the proposed design is able to decrease pressure-induced torque load on the pump,and the reduction increases for an increasing operating speed.For all three operating speeds tested,the reduction in pressure-induced torque ranges from 5%to up to 10%comparing to the original pump.展开更多
Every year in China,a significant number of mines are closed or abandoned.The pumped hydroelectric storage(PHS)and geothermal utilization are vital means to efficiently repurpose resources in abandoned mine.In this wo...Every year in China,a significant number of mines are closed or abandoned.The pumped hydroelectric storage(PHS)and geothermal utilization are vital means to efficiently repurpose resources in abandoned mine.In this work,the development potentials of the PHS and geothermal utilization systems were evaluated.Considering the geological conditions and meteorological data available of Jiahe abandoned mine,a simple evaluation model for PHS and geothermal utilization was established.The average efficiency of the PHS system exceeds 70%and the regulatable energy of a unit volume is over 1.53 kW·h/m^(3).The PHS system achieves optimal performance when the wind/solar power ratio reaches 0.6 and 0.3 in daily and year scale,respectively.In the geothermal utilization system,the outlet temperature and heat production are significantly affected by the injection flow rate.The heat production performance is more stable at lower rate flow,and the proportion of heat production is higher in the initial stage at greater flow rate.As the operating time increases,the proportion of heat production gradually decreases.The cyclic heat storage status has obvious advantages in heat generation and cooling.Furthermore,the energy-saving and emission reduction benefits of PHS and geothermal utilization systems were calculated.展开更多
Within the framework of achieving carbon neutrality,various industries are confronted with fresh challenges.The ongoing process of downsizing coal industry operations has evolved into a new phase,with the burgeoning p...Within the framework of achieving carbon neutrality,various industries are confronted with fresh challenges.The ongoing process of downsizing coal industry operations has evolved into a new phase,with the burgeoning proliferation of abandoned mines posing a persistent issue.Addressing the challenges and opportunities presented by these abandoned mines,this paper advocates for a scientific approach centered on the advancement of pumped storage energy alongside gas-oil complementary energy.Leveraging abandoned mine tunnels to establish pumped storage power stations holds significant ecological and economic importance for repurposing these sites.This initiative not only serves as an effective means to restore the ecological balance in mining regions but also provides an environmentally friendly approach to repurposing abandoned mine tunnels,offering a blueprint for economically viable pumped storage power stations.This article delineates five crucial scientific considerations and outlines seven primary models for the utilization of abandoned mine sites,delineating a novel,comprehensive pathway for energy and power development that emphasizes multi-energy complementarity and synergistic optimization within abandoned mines.展开更多
The pump performance parameters,such as pump pressure,plunger friction and pump valve resistance,are fundamental parameters of optimal design of pump efficiency and sucker rod pumping system (SRPS).In this paper,consi...The pump performance parameters,such as pump pressure,plunger friction and pump valve resistance,are fundamental parameters of optimal design of pump efficiency and sucker rod pumping system (SRPS).In this paper,considering the characteristic of geometrical nonlinear and rheology property of multiphase fluid,the pump performance parameters are studied.Firstly,a dynamics model of annular fluid flow is built.In the detail,a partial differential equation of annular fluid is established and a computing model of fluid pressure gradient is built.Secondly,the simulation models of plunger friction and hydraulic resistance of pump valve are built.Finally,a novel simulation method of fluid pressure in annular space is proposed with software ANSYS.In order to check up the correction of models proposed in this paper,the comparison curves of experiment and simulation results are given.Based on above model,the whole simulation model of plunger pump is simulated with Visual Basic 6.0.The results show that the fluid friction of pump plunger and instantaneous resistance of pump valve are nonlinear.The impact factors of pump performance parameters are analyzed,and their characteristic curves are given,which can help to optimize the pump motion parameters and pump structural.展开更多
China has embarked on an extensive and sustained endeavor to harness its coal resources for a substantial period.However,the depletion of coal reserves in mining regions has necessitated the closure or abandonment of ...China has embarked on an extensive and sustained endeavor to harness its coal resources for a substantial period.However,the depletion of coal reserves in mining regions has necessitated the closure or abandonment of numerous mines,resulting in a marked increase in the number of such facilities.Parallel to this,China is vigorously advancing the development of a novel energy power system,aimed at transitioning the power sector from a high-carbon,fossil fuel-dependent paradigm to a low-carbon,clean energy footing.展开更多
During the construction and operation of the abandoned mine pumped storage power station,the underground space surrounding rock body faces the complex stress environment under the action of mining disturbance,frequent...During the construction and operation of the abandoned mine pumped storage power station,the underground space surrounding rock body faces the complex stress environment under the action of mining disturbance,frequent pumping,water storage and other dynamic disturbances.The stability of the abandoned mine surrounding rock body is the basis for guaranteeing the safety and effectiveness of water storage in the underground space of the abandoned mine.By considering the two main factors of different stress levels and disturbance amplitudes,the mechanical properties,damage characteristics and acoustic emission characteristics of the abandoned mine perimeter rock body under dynamic disturbance were investigated using a creep-disturbed dynamic impact loading system.The experimental results show that:1)The stress level is considered to be the major contributing factor of the failure of muddy sandstone,followed by the amplitude of the disturbances;2)The time required for the destruction of muddy sandstone decreases with the increase of amplitude.When the stress level is 80%,the sandstone specimens have a decreasing number of cycles as the disturbance amplitude increases.The disturbance amplitude is sequentially increased from 4 MPa to 5,6,7,and 8 MPa,the number of cycles required for specimen destruction decreases significantly by 96.71%,99.13%,99.60%,and 99.93%,respectively;3)Disturbance amplitude and stress level have a significant effect on muddy sandstone damage and damage occurs only after a certain threshold is reached.With the increase of stress level and disturbance amplitude,the macroscopic damage of muddy sandstone is mainly conical,with obvious flake spalling and poor damage integrity;4)According to the time-dependent changes in AE energy and ringing counts,the acoustic emission activity during the failure process could be divided into three phases,namely,weakening period,smooth period,and surge period,corresponding to the compaction phase,elastic rise phase and post-peak damage phase.The research results are of reference significance for the damage evolution analysis of muddy sandstone under dynamic disturbance and the safety and stability of abandoned mine perimeter rock body.展开更多
An LD directly-pumped solid-state laser is considered to be one of the most promising mid-infrared light sources because of its simple principle,small size,and compact structure for the generation of mid-infrared(MIR)...An LD directly-pumped solid-state laser is considered to be one of the most promising mid-infrared light sources because of its simple principle,small size,and compact structure for the generation of mid-infrared(MIR)lasers in the 3-5µm band.However,the quantum defect of LD directly-pumped MIR solid-state lasers will be much larger than that of ordinary near-infrared LD pumped solid-state lasers,which may lead to thermal damage and limit their development.In order to solve this problem,the methods of reducing the specific surface area of the crystal and improving the thermal energy released by the crystal structure are discussed,and the opti⁃mal length of the laser crystal is determined.The cooling structures of barium yttrium fluoride laser crystals(Ho^(3+):BY_(2)F_(8))of different lengths were studied by thermal simulation using COMSOL software.The experimen⁃tal results show that the output power can be increased and the thermal stress in the laser crystal can be alleviated by using the laser crystal whose length is slightly shorter than that of the cooler.The final experiment shows that when the pump repetition rate is 15 Hz and the pulse width is 90µs,the single pulse energy is 7.28 mJ at the out⁃put wavelength of 3.9µm,which is about 3 times as large as that of the crystal with the length of 10 mm(2.81 mJ).Such results should be another breakthrough of our team since the first directly-pumped solid-state MIR laser was realized more than a year ago.It might pave the way for the construction of a feasible MIR laser in the near future.展开更多
Based on the state-of-the-art studies of solar-soil source heat pump compound system, operation patterns of solar-soil compound system were analyzed, particularly the advantages of parallel operation pattern. It is fo...Based on the state-of-the-art studies of solar-soil source heat pump compound system, operation patterns of solar-soil compound system were analyzed, particularly the advantages of parallel operation pattern. It is found that parallel operation pattern is better for solar-soil compound system. Furthermore, the heat balance issue of solar-soil compound system was emphatically analyzed from four aspects, which were annual analysis of heating and cooling load, the heat exchange of ground heat exchanger, capacity determination of solar-assisted heat sottrce and heat balance calculation of solar-soil compound system. Moreover, annual rate of heat balance in a solar-soil source heat pump compound system was calculated with a case study. It is shown that the annual heat unbalance ratio is 19%, which is less than 20%. As a result, the practical solar-soil compound system can basically maintain the heat balance of soil.展开更多
For the purpose of improving efficiency and realizing start–stop function, an electric oil pump(EOP) is integrated into an 8-speed automatic transmission(AT). A mathematical model is built to calculate the transmissi...For the purpose of improving efficiency and realizing start–stop function, an electric oil pump(EOP) is integrated into an 8-speed automatic transmission(AT). A mathematical model is built to calculate the transmission power loss and the hydraulic system leakage. Based on this model, a flow-based control strategy is developed for EOP to satisfy the system flow requirement. This control strategy is verified through the forward driving simulation. The results indicate that there is a best combination for the size of mechanical oil pump(MOP) and EOP in terms of minimum energy consumption. In order to get a quick and smooth starting process, control strategies of the EOP and the on-coming clutch are proposed. The test environment on a prototype vehicle is built to verify the feasibility of the integrated EOP and its control strategies. The results show that the selected EOP can satisfy the flow requirement and a quick and smooth starting performance is achieved in the start–stop function. This research has a high value for the forward design of EOP in automatic transmissions with respect to efficiency improvement and start–stop function.展开更多
The size of impeller reflux holes for centrifugal pump has influence on the pressure distribution of front and rear shrouds and rear pump chamber, as well as energy characteristics of whole pump and axial force. Low s...The size of impeller reflux holes for centrifugal pump has influence on the pressure distribution of front and rear shrouds and rear pump chamber, as well as energy characteristics of whole pump and axial force. Low specific-speed centrifugal pump with Q=12.5 m3/h, H=60 m, n=2950 r/min was selected to be designed with eight axial reflux balance holes with 4.5 mm in diameter. The simulated Q-H curve and net positive suction head(NPSH) were in good agreement with experimental results, which illustrated that centrifugal pump with axial reflux balance holes was superior in the cavitation characteristic; however, it showed to little superiority in head and efficiency. The pressure in rear pump chamber at 0.6 times rate flow is 29.36% of pressure difference between outlet and inlet, which reduces to 29.10% at rate flow and 28.33% at 1.4 times rate flow. As the whole, the pressure distribution on front and rear shrouds from simulation results is not a standard parabola, and axial force decreases as flow rate increases. Radical reflux balance holes chosen to be 5.2 mm and 5.9 mm in diameter were further designed with other hydraulic parts unchanged. With structural grids adopted for total flow field, contrast numerical simulation on internal flow characteristics was conducted based on momentum equations and standard turbulence model(κ-ε). It is found that axial force of pump with radical reflux balance holes of5.2 mm and 5.9 mm in diameter is significantly less than that with radical reflux balance holes of 4.5 mm in diameter. Better axial force balance is obtained as the ratio of area of reflux balance holes and area of sealing ring exceeds 6.展开更多
Based on RNG k-ε turbulence model and sliding grid technique, solid-liquid two-phase three-dimensional(3-D) unsteady turbulence of full passage in slurry pump was simulated by means of Fluent software. The effects of...Based on RNG k-ε turbulence model and sliding grid technique, solid-liquid two-phase three-dimensional(3-D) unsteady turbulence of full passage in slurry pump was simulated by means of Fluent software. The effects of unsteady flow characteristics on solid-liquid two-phase flow and pump performance were researched under design condition. The results show that clocking effect has a significant influence on the flow in pump, and the fluctuation of flow velocity and pressure is obvious, particularly near the volute tongue, at the position of small sections of volute and within diffuser. Clocking effect has a more influence on liquid-phase than on solid-phase, and the wake-jet structure of relative velocity of solid-phase is less obvious than liquid-phase near the volute tongue and the impeller passage outlet. The fluctuation of relative velocity of solid-phase flow is 7.6% smaller than liquid-phase flow at the impeller outlet on circular path. Head and radial forces of the impeller are 8.1% and 85.7% of fluctuation, respectively. The results provide a theoretical basis for further research for turbulence, improving efficient, reducing the hydraulic losses and wear. Finally, field tests were carried out to verify the operation and wear of slurry pump.展开更多
A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coeff...A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coefficient of performance decreases and the temperature difference between the hot and cold sides becomes larger with the increase of the operating voltage,but the heating time becomes short.The higher the temperature of water,the greater the temperature difference between the hot and cold sides,leading to a smaller coefficient of performance.Under an exhaust temperature of 36 ℃,the coefficient of performance decreases from 1.66 to 1.22 when the temperature of water increases from 28 ℃ to 46 ℃ with operating voltage 16 V.Performance tests illustrate that,compared with the conventional electrical water heaters,the new kind of thermoelectric heat pump water heater is more coefficient.展开更多
In order to investigate the effect of sampling frequency and time on pressure fluctuations, the three-dimensional unsteady numerical simulations were conducted in a circulating water pump. Through comparison of turbul...In order to investigate the effect of sampling frequency and time on pressure fluctuations, the three-dimensional unsteady numerical simulations were conducted in a circulating water pump. Through comparison of turbulence models with hydraulic performance experiment, SST k-co model was confirmed to study the rational determination of sampling frequency and time better. The Fast Fourier Transform (FFT) technology was then adopted to process those fluctuating pressure signals obtained. On these bases, the characteristics of pressure fluctuations acting on the tongue were discussed. It is found that aliasing errors decrease at higher sampling frequency of 17 640 Hz, but not at a lower sampling frequency of 1 764 Hz. Correspondingly, an output frequency range ten-times wider is obtained at 17 640 Hz. Compared with 8R, when the sampling time is shorter, the amplitudes may be overvalued, and the frequencies and amplitudes of low-frequency fluctuations can not be well predicted. The frequencies at the tongue are in good agreement with the values calculated by formula and the frequency compositions less than the blade passing frequency are accurately predicted.展开更多
Based on the characteristics of large flow rate , low head , short annual operation time , and high reliability of the city flood-control pumping stations , a new-type shaft tubular pumping system featuring a shaft su...Based on the characteristics of large flow rate , low head , short annual operation time , and high reliability of the city flood-control pumping stations , a new-type shaft tubular pumping system featuring a shaft suction box and a siphon-type discharge passage with a vacuum breaker as the cutoff device was developed , which possesses such advantages as simple structure , reliable cutoff , and high energy performance.Taking some pumping stations as the case studies , in the light of the specified operation conditions , the hydraulic optimal design of the shaft-type tubular pumping system was determined and the optimized shape of the system was recommended.The performance prediction based on the computational fluid dynamics methodology was determined and the model test verification was conducted.The results show that the predicted data agree with the experimental head and efficiency so that both methods can be used to determine the performance of a real pumping station.Finally , the in-situ measurements of a pumping station during the commissioning period further verified that the shaft-type tubular pumping station with a siphon discharge passage is of higher efficiency , more reliable and stable.展开更多
文摘In the printing industry,vacuum pumps play a critical role in sheet feeding and gripping processes.In order to improve the efficiency of vacuum pumps,By analyzing the internal flow field of the vane type vacuum pump,the CFD method was used to simulate the internal flow field of the air pump,and it was found that a main vortex was formed near the rotor of the trailing blade.Based on this observation,a new rotor shape design was proposed in this study,which design places arc-shaped depressed on the circumference of the rotor where the main vortex forms.The existence of the depression facilitated forward motion of the main airflow and thus effectively restricting reverse flow.Simulation results demonstrated that the proposed design is able to decrease pressure-induced torque load on the pump,and the reduction increases for an increasing operating speed.For all three operating speeds tested,the reduction in pressure-induced torque ranges from 5%to up to 10%comparing to the original pump.
基金Project(8212033)supported by the Natural Science Foundation of Beijing,ChinaProject(BBJ2023051)supported by the Fundamental Research Funds of China University of Mining and Technology-BeijingProject(SKLGDUEK202221)supported by the Innovation Fund Research Project,China。
文摘Every year in China,a significant number of mines are closed or abandoned.The pumped hydroelectric storage(PHS)and geothermal utilization are vital means to efficiently repurpose resources in abandoned mine.In this work,the development potentials of the PHS and geothermal utilization systems were evaluated.Considering the geological conditions and meteorological data available of Jiahe abandoned mine,a simple evaluation model for PHS and geothermal utilization was established.The average efficiency of the PHS system exceeds 70%and the regulatable energy of a unit volume is over 1.53 kW·h/m^(3).The PHS system achieves optimal performance when the wind/solar power ratio reaches 0.6 and 0.3 in daily and year scale,respectively.In the geothermal utilization system,the outlet temperature and heat production are significantly affected by the injection flow rate.The heat production performance is more stable at lower rate flow,and the proportion of heat production is higher in the initial stage at greater flow rate.As the operating time increases,the proportion of heat production gradually decreases.The cyclic heat storage status has obvious advantages in heat generation and cooling.Furthermore,the energy-saving and emission reduction benefits of PHS and geothermal utilization systems were calculated.
基金Project(202208340045)supported by the China Scholarship Council FundProject(U21A20110)supported by the Regional Innovation and Development Joint Fund of National Natural Science Foundation of China+1 种基金Project(EUCMR202201)supported by the Open Project Program of Anhui Engineering Research Center of Exploitation and Utilization of Closed/abandoned Mine Resources,ChinaProject(2023cxcyzx063)supported by the Anhui Province New Era Talent Education Project,China。
文摘Within the framework of achieving carbon neutrality,various industries are confronted with fresh challenges.The ongoing process of downsizing coal industry operations has evolved into a new phase,with the burgeoning proliferation of abandoned mines posing a persistent issue.Addressing the challenges and opportunities presented by these abandoned mines,this paper advocates for a scientific approach centered on the advancement of pumped storage energy alongside gas-oil complementary energy.Leveraging abandoned mine tunnels to establish pumped storage power stations holds significant ecological and economic importance for repurposing these sites.This initiative not only serves as an effective means to restore the ecological balance in mining regions but also provides an environmentally friendly approach to repurposing abandoned mine tunnels,offering a blueprint for economically viable pumped storage power stations.This article delineates five crucial scientific considerations and outlines seven primary models for the utilization of abandoned mine sites,delineating a novel,comprehensive pathway for energy and power development that emphasizes multi-energy complementarity and synergistic optimization within abandoned mines.
基金Projects(ZR2017LEE002,ZR2016HB59)supported by the Natural Science Foundation of Shandong Province,ChinaProject(LYDX2016BS032)supported by the Scientific Research Starting Foundation of Linyi University,China+1 种基金Project(2017YF012)supported by Shandong Agricultural Machinery Equipment Research and Development Innovation,ChinaProjects(201801219003,201802026003)supported by Collaborative Education Project of Industry-Education Cooperation of National Education Ministry,China
文摘The pump performance parameters,such as pump pressure,plunger friction and pump valve resistance,are fundamental parameters of optimal design of pump efficiency and sucker rod pumping system (SRPS).In this paper,considering the characteristic of geometrical nonlinear and rheology property of multiphase fluid,the pump performance parameters are studied.Firstly,a dynamics model of annular fluid flow is built.In the detail,a partial differential equation of annular fluid is established and a computing model of fluid pressure gradient is built.Secondly,the simulation models of plunger friction and hydraulic resistance of pump valve are built.Finally,a novel simulation method of fluid pressure in annular space is proposed with software ANSYS.In order to check up the correction of models proposed in this paper,the comparison curves of experiment and simulation results are given.Based on above model,the whole simulation model of plunger pump is simulated with Visual Basic 6.0.The results show that the fluid friction of pump plunger and instantaneous resistance of pump valve are nonlinear.The impact factors of pump performance parameters are analyzed,and their characteristic curves are given,which can help to optimize the pump motion parameters and pump structural.
文摘China has embarked on an extensive and sustained endeavor to harness its coal resources for a substantial period.However,the depletion of coal reserves in mining regions has necessitated the closure or abandonment of numerous mines,resulting in a marked increase in the number of such facilities.Parallel to this,China is vigorously advancing the development of a novel energy power system,aimed at transitioning the power sector from a high-carbon,fossil fuel-dependent paradigm to a low-carbon,clean energy footing.
基金Project(52204101)supported by the National Natural Science Foundation of ChinaProject(ZR2022QE137)supported by the Natural Science Foundation of Shandong Province,ChinaProject(SKLGDUEK2023)supported by the Open Project of State Key Laboratory for Geomechanics and Deep Underground Engineering in China University of Mining&Technology,Beijing,China。
文摘During the construction and operation of the abandoned mine pumped storage power station,the underground space surrounding rock body faces the complex stress environment under the action of mining disturbance,frequent pumping,water storage and other dynamic disturbances.The stability of the abandoned mine surrounding rock body is the basis for guaranteeing the safety and effectiveness of water storage in the underground space of the abandoned mine.By considering the two main factors of different stress levels and disturbance amplitudes,the mechanical properties,damage characteristics and acoustic emission characteristics of the abandoned mine perimeter rock body under dynamic disturbance were investigated using a creep-disturbed dynamic impact loading system.The experimental results show that:1)The stress level is considered to be the major contributing factor of the failure of muddy sandstone,followed by the amplitude of the disturbances;2)The time required for the destruction of muddy sandstone decreases with the increase of amplitude.When the stress level is 80%,the sandstone specimens have a decreasing number of cycles as the disturbance amplitude increases.The disturbance amplitude is sequentially increased from 4 MPa to 5,6,7,and 8 MPa,the number of cycles required for specimen destruction decreases significantly by 96.71%,99.13%,99.60%,and 99.93%,respectively;3)Disturbance amplitude and stress level have a significant effect on muddy sandstone damage and damage occurs only after a certain threshold is reached.With the increase of stress level and disturbance amplitude,the macroscopic damage of muddy sandstone is mainly conical,with obvious flake spalling and poor damage integrity;4)According to the time-dependent changes in AE energy and ringing counts,the acoustic emission activity during the failure process could be divided into three phases,namely,weakening period,smooth period,and surge period,corresponding to the compaction phase,elastic rise phase and post-peak damage phase.The research results are of reference significance for the damage evolution analysis of muddy sandstone under dynamic disturbance and the safety and stability of abandoned mine perimeter rock body.
基金Supported by the National Key Research and Development Program of China(2021YFA0718803)。
文摘An LD directly-pumped solid-state laser is considered to be one of the most promising mid-infrared light sources because of its simple principle,small size,and compact structure for the generation of mid-infrared(MIR)lasers in the 3-5µm band.However,the quantum defect of LD directly-pumped MIR solid-state lasers will be much larger than that of ordinary near-infrared LD pumped solid-state lasers,which may lead to thermal damage and limit their development.In order to solve this problem,the methods of reducing the specific surface area of the crystal and improving the thermal energy released by the crystal structure are discussed,and the opti⁃mal length of the laser crystal is determined.The cooling structures of barium yttrium fluoride laser crystals(Ho^(3+):BY_(2)F_(8))of different lengths were studied by thermal simulation using COMSOL software.The experimen⁃tal results show that the output power can be increased and the thermal stress in the laser crystal can be alleviated by using the laser crystal whose length is slightly shorter than that of the cooler.The final experiment shows that when the pump repetition rate is 15 Hz and the pulse width is 90µs,the single pulse energy is 7.28 mJ at the out⁃put wavelength of 3.9µm,which is about 3 times as large as that of the crystal with the length of 10 mm(2.81 mJ).Such results should be another breakthrough of our team since the first directly-pumped solid-state MIR laser was realized more than a year ago.It might pave the way for the construction of a feasible MIR laser in the near future.
基金Project(50838009) supported by the National Natural Science Foundation of ChinaProject(2010DFA72740-05) supported by the International Science & Technology Cooperation Program of China
文摘Based on the state-of-the-art studies of solar-soil source heat pump compound system, operation patterns of solar-soil compound system were analyzed, particularly the advantages of parallel operation pattern. It is found that parallel operation pattern is better for solar-soil compound system. Furthermore, the heat balance issue of solar-soil compound system was emphatically analyzed from four aspects, which were annual analysis of heating and cooling load, the heat exchange of ground heat exchanger, capacity determination of solar-assisted heat sottrce and heat balance calculation of solar-soil compound system. Moreover, annual rate of heat balance in a solar-soil source heat pump compound system was calculated with a case study. It is shown that the annual heat unbalance ratio is 19%, which is less than 20%. As a result, the practical solar-soil compound system can basically maintain the heat balance of soil.
基金Project(51405010)supported by the National Natural Science Foundation of ChinaProject(2011BAG09B00)supported by the National Science and Technology Support Program of China
文摘For the purpose of improving efficiency and realizing start–stop function, an electric oil pump(EOP) is integrated into an 8-speed automatic transmission(AT). A mathematical model is built to calculate the transmission power loss and the hydraulic system leakage. Based on this model, a flow-based control strategy is developed for EOP to satisfy the system flow requirement. This control strategy is verified through the forward driving simulation. The results indicate that there is a best combination for the size of mechanical oil pump(MOP) and EOP in terms of minimum energy consumption. In order to get a quick and smooth starting process, control strategies of the EOP and the on-coming clutch are proposed. The test environment on a prototype vehicle is built to verify the feasibility of the integrated EOP and its control strategies. The results show that the selected EOP can satisfy the flow requirement and a quick and smooth starting performance is achieved in the start–stop function. This research has a high value for the forward design of EOP in automatic transmissions with respect to efficiency improvement and start–stop function.
基金Project(51179075)supported by the National Natural Science Foundation of ChinaProject(BK20131256)supported by the Natural Science Funds of Jiangsu Province,ChinaProject supported by the Priority Academic Program Development of Jiangsu High Education Institutions,China
文摘The size of impeller reflux holes for centrifugal pump has influence on the pressure distribution of front and rear shrouds and rear pump chamber, as well as energy characteristics of whole pump and axial force. Low specific-speed centrifugal pump with Q=12.5 m3/h, H=60 m, n=2950 r/min was selected to be designed with eight axial reflux balance holes with 4.5 mm in diameter. The simulated Q-H curve and net positive suction head(NPSH) were in good agreement with experimental results, which illustrated that centrifugal pump with axial reflux balance holes was superior in the cavitation characteristic; however, it showed to little superiority in head and efficiency. The pressure in rear pump chamber at 0.6 times rate flow is 29.36% of pressure difference between outlet and inlet, which reduces to 29.10% at rate flow and 28.33% at 1.4 times rate flow. As the whole, the pressure distribution on front and rear shrouds from simulation results is not a standard parabola, and axial force decreases as flow rate increases. Radical reflux balance holes chosen to be 5.2 mm and 5.9 mm in diameter were further designed with other hydraulic parts unchanged. With structural grids adopted for total flow field, contrast numerical simulation on internal flow characteristics was conducted based on momentum equations and standard turbulence model(κ-ε). It is found that axial force of pump with radical reflux balance holes of5.2 mm and 5.9 mm in diameter is significantly less than that with radical reflux balance holes of 4.5 mm in diameter. Better axial force balance is obtained as the ratio of area of reflux balance holes and area of sealing ring exceeds 6.
基金Project(51375498)supported by the National Natural Science Foundation of China
文摘Based on RNG k-ε turbulence model and sliding grid technique, solid-liquid two-phase three-dimensional(3-D) unsteady turbulence of full passage in slurry pump was simulated by means of Fluent software. The effects of unsteady flow characteristics on solid-liquid two-phase flow and pump performance were researched under design condition. The results show that clocking effect has a significant influence on the flow in pump, and the fluctuation of flow velocity and pressure is obvious, particularly near the volute tongue, at the position of small sections of volute and within diffuser. Clocking effect has a more influence on liquid-phase than on solid-phase, and the wake-jet structure of relative velocity of solid-phase is less obvious than liquid-phase near the volute tongue and the impeller passage outlet. The fluctuation of relative velocity of solid-phase flow is 7.6% smaller than liquid-phase flow at the impeller outlet on circular path. Head and radial forces of the impeller are 8.1% and 85.7% of fluctuation, respectively. The results provide a theoretical basis for further research for turbulence, improving efficient, reducing the hydraulic losses and wear. Finally, field tests were carried out to verify the operation and wear of slurry pump.
基金Supported by Hunan Science and Technology Office(06wk3023)National High Technology Research and Development Program of China(2006AA05Z229)Project-sponsored by SRFfor ROCS,SEM
文摘A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coefficient of performance decreases and the temperature difference between the hot and cold sides becomes larger with the increase of the operating voltage,but the heating time becomes short.The higher the temperature of water,the greater the temperature difference between the hot and cold sides,leading to a smaller coefficient of performance.Under an exhaust temperature of 36 ℃,the coefficient of performance decreases from 1.66 to 1.22 when the temperature of water increases from 28 ℃ to 46 ℃ with operating voltage 16 V.Performance tests illustrate that,compared with the conventional electrical water heaters,the new kind of thermoelectric heat pump water heater is more coefficient.
基金Project supported by the Priority Academic Development Program of Jiangsu Higher Education Institutions, ChinaProject(CXZZ12_0680) supported by Postgraduate Innovation Foundation of Jiangsu Province, ChinaProject(12JDG082) supported by the Advanced Talent Foundation of Jiangsu University, China
文摘In order to investigate the effect of sampling frequency and time on pressure fluctuations, the three-dimensional unsteady numerical simulations were conducted in a circulating water pump. Through comparison of turbulence models with hydraulic performance experiment, SST k-co model was confirmed to study the rational determination of sampling frequency and time better. The Fast Fourier Transform (FFT) technology was then adopted to process those fluctuating pressure signals obtained. On these bases, the characteristics of pressure fluctuations acting on the tongue were discussed. It is found that aliasing errors decrease at higher sampling frequency of 17 640 Hz, but not at a lower sampling frequency of 1 764 Hz. Correspondingly, an output frequency range ten-times wider is obtained at 17 640 Hz. Compared with 8R, when the sampling time is shorter, the amplitudes may be overvalued, and the frequencies and amplitudes of low-frequency fluctuations can not be well predicted. The frequencies at the tongue are in good agreement with the values calculated by formula and the frequency compositions less than the blade passing frequency are accurately predicted.
基金support by the 11th Five Year Key Project of China’s National Scientific Supporting Plan(Grant No.2006BAB04A03)the Hydraulic Engineering Project from the Water Resources Department of Jiangsu Province(Grant No.2010023)
文摘Based on the characteristics of large flow rate , low head , short annual operation time , and high reliability of the city flood-control pumping stations , a new-type shaft tubular pumping system featuring a shaft suction box and a siphon-type discharge passage with a vacuum breaker as the cutoff device was developed , which possesses such advantages as simple structure , reliable cutoff , and high energy performance.Taking some pumping stations as the case studies , in the light of the specified operation conditions , the hydraulic optimal design of the shaft-type tubular pumping system was determined and the optimized shape of the system was recommended.The performance prediction based on the computational fluid dynamics methodology was determined and the model test verification was conducted.The results show that the predicted data agree with the experimental head and efficiency so that both methods can be used to determine the performance of a real pumping station.Finally , the in-situ measurements of a pumping station during the commissioning period further verified that the shaft-type tubular pumping station with a siphon discharge passage is of higher efficiency , more reliable and stable.