The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is...The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is focused on the parameters acquisition and operation analysis of the GSHP system in Tangshan. Results show the average COPs(coefficient of performance) are2.85 and 2.70 in summer and winter, respectively, and heat(cold) unbalance underground existed after whole year operation. The analysis of data also indicates that the direct borehole air-conditioning saved some power consumption obviously in the early stage of summer and energy saving of the GSHP system depended remarkably on its operation and management level. Besides the observation points of ground temperature are laid for a large-scale GSHP system, and the hydraulic balance of the pipes group needs to be concerned specially in safeguarding better reliability.展开更多
Initiated three decades ago,integrated design of controllers and fault detectors has continuously attracted research attention.The recent development of the unified control and detection framework with an observer-bas...Initiated three decades ago,integrated design of controllers and fault detectors has continuously attracted research attention.The recent development of the unified control and detection framework with an observer-based residual generator in its core gives a more general form of the previous works.Its applications to residual centred modelling of uncertain control systems,fault detection in feedback control systems with uncertainties,fault-tolerant control(FTC)as well as control performance degradation monitoring,detection and recovery are introduced.In conclusion,some future perspectives are proposed.展开更多
基金Project(2012BAJ06B04)supported by"12th Five-Year Plan"National science and Technology,ChinaProject(2014-228)supported by Department of Housing and Urban Rural Development of Hebei,China
文摘The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is focused on the parameters acquisition and operation analysis of the GSHP system in Tangshan. Results show the average COPs(coefficient of performance) are2.85 and 2.70 in summer and winter, respectively, and heat(cold) unbalance underground existed after whole year operation. The analysis of data also indicates that the direct borehole air-conditioning saved some power consumption obviously in the early stage of summer and energy saving of the GSHP system depended remarkably on its operation and management level. Besides the observation points of ground temperature are laid for a large-scale GSHP system, and the hydraulic balance of the pipes group needs to be concerned specially in safeguarding better reliability.
基金This work was supported by the National Natural Science Foundation of China(62020106003,62073029)the Beijing Natural Science Foundation(4202045)the Fundamental Research Funds for the Central Universities(FRF-TP-20-012A3).
文摘Initiated three decades ago,integrated design of controllers and fault detectors has continuously attracted research attention.The recent development of the unified control and detection framework with an observer-based residual generator in its core gives a more general form of the previous works.Its applications to residual centred modelling of uncertain control systems,fault detection in feedback control systems with uncertainties,fault-tolerant control(FTC)as well as control performance degradation monitoring,detection and recovery are introduced.In conclusion,some future perspectives are proposed.