This study established a novel method for the simultaneous detection of two-component gases.Radio frequency(RF)white noise disturbance laser current and wavelength modulation were simultaneously used to improve the of...This study established a novel method for the simultaneous detection of two-component gases.Radio frequency(RF)white noise disturbance laser current and wavelength modulation were simultaneously used to improve the off-axis integrated cavity output spectroscopy technique,and a high-precision dual modulation OA-ICOS(RF-WM-OA-ICOS)system was established.The two laser beams were coupled into one laser beam that was applied incident to the cavity of RF-WM-OA-ICOS system.The second harmonic signals of CH_(4)and CO_(2)gas simultaneously appeared in the rising or falling edge of a triangular wave.This method was used to measure CH_(4)and CO_(2)with different concentrations.The results indicated that the proposed system has high stability and can accurately and simultaneously measure the concentrations of CH_(4)and CO_(2),with an optimal integration time of 220 s.The minimum detection limit was 10 ppb for CH_(4)and 1.5 ppm for CO_(2).The corresponding noise equivalent absorption sensitivity values were calculated as 2.67×10^(-13)cm^(-1)·Hz^(-1/2)and 5.18×10^(-11)cm^(-1)·Hz^(-1/2),respectively.The proposed dual-component gas simultaneous detection method can also be used for high-precision simultaneous detection of other gases.Therefore,this study may serve as a reference for developing portable multicomponent gas analyzers.展开更多
Integrated cavity output spectroscopy(ICOS) is an effective technique in trace gase detection.The strong absorption due to the long optical path of this method makes it challenging in the application scenes that have ...Integrated cavity output spectroscopy(ICOS) is an effective technique in trace gase detection.The strong absorption due to the long optical path of this method makes it challenging in the application scenes that have large gas concentration fluctuation,especially when the gas concentration is high.In this paper,we demonstrate an extension of the dynamic range of ICOS by using a detuned laser combined with an off-axis integrating cavity.With this,we improve the upper limit of the dynamic detection range from 0.1%(1000 ppm) to 20% of the gas concentration.This method provides a way of using ICOS in the applications with unpredictable gas concentrations such as gas leak detection,ocean acidification,carbon sequestration,etc.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant Nos.62005108 and 62205134)the National Key Research and Development Program of China(Grant No.2022YFC2807701)the Natural Science Foundation of the Higher Education Institutions of Jiangsu Province,China(Grant Nos.20KJB140009 and 21KJB140008)。
文摘This study established a novel method for the simultaneous detection of two-component gases.Radio frequency(RF)white noise disturbance laser current and wavelength modulation were simultaneously used to improve the off-axis integrated cavity output spectroscopy technique,and a high-precision dual modulation OA-ICOS(RF-WM-OA-ICOS)system was established.The two laser beams were coupled into one laser beam that was applied incident to the cavity of RF-WM-OA-ICOS system.The second harmonic signals of CH_(4)and CO_(2)gas simultaneously appeared in the rising or falling edge of a triangular wave.This method was used to measure CH_(4)and CO_(2)with different concentrations.The results indicated that the proposed system has high stability and can accurately and simultaneously measure the concentrations of CH_(4)and CO_(2),with an optimal integration time of 220 s.The minimum detection limit was 10 ppb for CH_(4)and 1.5 ppm for CO_(2).The corresponding noise equivalent absorption sensitivity values were calculated as 2.67×10^(-13)cm^(-1)·Hz^(-1/2)and 5.18×10^(-11)cm^(-1)·Hz^(-1/2),respectively.The proposed dual-component gas simultaneous detection method can also be used for high-precision simultaneous detection of other gases.Therefore,this study may serve as a reference for developing portable multicomponent gas analyzers.
基金Project supported by the National Key Research and Development Program of China(Grant No.2017YFC0209700)the National Natural Science Foundation of China(Grant No.41730103)。
文摘Integrated cavity output spectroscopy(ICOS) is an effective technique in trace gase detection.The strong absorption due to the long optical path of this method makes it challenging in the application scenes that have large gas concentration fluctuation,especially when the gas concentration is high.In this paper,we demonstrate an extension of the dynamic range of ICOS by using a detuned laser combined with an off-axis integrating cavity.With this,we improve the upper limit of the dynamic detection range from 0.1%(1000 ppm) to 20% of the gas concentration.This method provides a way of using ICOS in the applications with unpredictable gas concentrations such as gas leak detection,ocean acidification,carbon sequestration,etc.