The Na I(Tl) scintillation detector has a number of unique advantages, including wide use, high light yield,and its low price. It is difficult to obtain the decomposition of instrument response spectrum because of lim...The Na I(Tl) scintillation detector has a number of unique advantages, including wide use, high light yield,and its low price. It is difficult to obtain the decomposition of instrument response spectrum because of limitations associated with the Na I(Tl) scintillation detector's energy resolution. This paper, based on the physical process of c photons released from decay nuclides, generating an instrument response spectrum, uses the Monte Carlo method to simulate c photons with Na I(Tl) scintillation detector interaction. The Monte Carlo response matrix is established by different single energy γ-rays with detector effects. The Gold and the improved Boosted-Gold iterative algorithms have also been used in this paper to solve the response matrix parameters through decomposing tests,such as simulating a multi-characteristic energy c-ray spectrum and simulating synthesized overlapping peaks cray spectrum. An inversion decomposition of the c instrument response spectrum for measured samples(U series, Th series and U–Th mixed sources, among others)can be achieved under the response matrix. The decomposing spectrum can be better distinguished between the similar energy characteristic peaks, which improve the error levels of activity analysis caused by the overlapping peak with significant effects.展开更多
闪烁体探测器γ能谱测量中,闪烁光子的产生、传输及光电器件收集、倍增均对能谱的分辨有巨大影响。为了精确模拟闪烁体探测器的能量分辨,采用蒙特卡洛模拟软件GEANT4建立了一套模型,分别对Na I(TI),LaBr_3:0.5%Ce^(3+)闪烁体探测器测量...闪烁体探测器γ能谱测量中,闪烁光子的产生、传输及光电器件收集、倍增均对能谱的分辨有巨大影响。为了精确模拟闪烁体探测器的能量分辨,采用蒙特卡洛模拟软件GEANT4建立了一套模型,分别对Na I(TI),LaBr_3:0.5%Ce^(3+)闪烁体探测器测量能量为662 ke V的γ射线能谱进行模拟,获得的结果与实验测试结果能够很好的符合,验证了建立模型合理性与可靠性,为闪烁体的设计提供了一套更精确的开发工具。展开更多
This report presents a design system based on the use of CsI(TI) detectors to search for lost radioactive sources that are dangerous and harmful to individuals, including searching persons. For this purpose, the GEANT...This report presents a design system based on the use of CsI(TI) detectors to search for lost radioactive sources that are dangerous and harmful to individuals, including searching persons. For this purpose, the GEANT4 simulation toolkit was utilized to develop a system based on three detectors. Various simulated analyses were performed on the dose rates of the three detectors using different source–detector distances and detector separation. There were good agreement between the simulated results and the experimentally measured data. A new method was discussed to detect and search for radioactive sources based only on the dose rates in detectors with source activity. Numerical analyses were performed based on the measured dose rates and the difference of distances to determine the actual location of the lost single or multiple γ-ray sources at a specific angle. The detection limit was calculated from the background radiation to establish the sensitivity and capability of the proposed detector system. This system can be applied in fields in which it is necessary to locate unknown radioactive sources.展开更多
A Levenberg–Marquardt Gaussian fitting algorithm has been used for analyzing the overlap of three peaks(the 583-ke V peak of^(208)Tl, the 609-ke V peak of214 Bi, and the 662-ke V peak of^(137)Cs) using an in situ Na ...A Levenberg–Marquardt Gaussian fitting algorithm has been used for analyzing the overlap of three peaks(the 583-ke V peak of^(208)Tl, the 609-ke V peak of214 Bi, and the 662-ke V peak of^(137)Cs) using an in situ Na I(Tl) scintillation spectrometer. The algorithm, in addition,was compared with a genetic algorithm used for multiple deconvolution. The three fitted peak areas(583, 609, and662 ke V) were calculated from the measured gamma-ray spectra obtained from a simulation experiment in which a^(137) Cs source was buried at different soil depths(from 18 to38 cm). The application of the Levenberg–Marquardt algorithm yielded similar results compared to the genetic algorithm. A lack-of-fit test showed that the fitting is good when the instrumental noise levels were estimated from replicated analyses. The relative fitting error of the total net area and the residual standard deviation were within 5 %and 0.04, respectively, and the goodness of the fitting was better than 0.98. While the methods used in this paper give high performance, the results may lead to incorrect estimation when the signal-to-noise ratio is smaller than-30 d B. This study is useful for the determination of radioactive specific activity of^(137) Cs by in situ spectrometry.展开更多
The GECAM series of satellites utilizes LaBr_(3)(Ce),LaBr_(3)(Ce,Sr),and NaI(Tl)crystals as sensitive materials for gamma-ray detectors(GRDs).To investigate the nonlinearity in the detection of low-energy gamma rays a...The GECAM series of satellites utilizes LaBr_(3)(Ce),LaBr_(3)(Ce,Sr),and NaI(Tl)crystals as sensitive materials for gamma-ray detectors(GRDs).To investigate the nonlinearity in the detection of low-energy gamma rays and address the errors in the calibration of the E-C relationship,comprehensive tests and comparative studies of the three aforementioned crystals were conducted using Compton electrons,radioactive sources,and mono-energetic X-rays.The nonlinearity test results of the Compton electrons and X-rays demonstrated substantial differences,with all three crystals presenting a higher nonlinearity for X/-rays than for Compton electrons.Despite the LaBr_(3)(Ce)and LaBr_(3)(Ce,Sr)crystals having higher absolute light yields,they exhibited a noticeable nonlinear decrease in the light yield,especially at energies below 400 keV.The NaI(Tl)crystal demonstrated an"excess"light output in the 6-200 keV range,reaching a maximum"excess"of 9.2%at 30 keV in the X-ray testing and up to 15.5%at 14 keV during Compton electron testing,indicating a significant advantage in the detection of low-energy gamma rays.Furthermore,we explored the underlying causes of the observed nonlinearity in these crystals.This study not only elucidates the detector responses of GECAM,but also initiates a comprehensive investigation of the nonlinearity of domestically produced lanthanum bromide and sodium iodide crystals.展开更多
基金supported by National Natural Science Foundation of China(No.11365001)National Major Scientific Equipment Development Projects(No.041514065)+1 种基金Natural Science Foundation of Jiangxi(No.20161BAB201035)Fundamental Science on Radioactive Geology and Exploration Technology Laboratory,East China Institute of Technology(No.RGET1316)
文摘The Na I(Tl) scintillation detector has a number of unique advantages, including wide use, high light yield,and its low price. It is difficult to obtain the decomposition of instrument response spectrum because of limitations associated with the Na I(Tl) scintillation detector's energy resolution. This paper, based on the physical process of c photons released from decay nuclides, generating an instrument response spectrum, uses the Monte Carlo method to simulate c photons with Na I(Tl) scintillation detector interaction. The Monte Carlo response matrix is established by different single energy γ-rays with detector effects. The Gold and the improved Boosted-Gold iterative algorithms have also been used in this paper to solve the response matrix parameters through decomposing tests,such as simulating a multi-characteristic energy c-ray spectrum and simulating synthesized overlapping peaks cray spectrum. An inversion decomposition of the c instrument response spectrum for measured samples(U series, Th series and U–Th mixed sources, among others)can be achieved under the response matrix. The decomposing spectrum can be better distinguished between the similar energy characteristic peaks, which improve the error levels of activity analysis caused by the overlapping peak with significant effects.
文摘研究了封装反射层材料对GAGG:Ce探测器光收集的影响,同时与Na I(TI)闪烁体探测器进行了详细的对比性实验,用137Cs、60Co标准源测量了γ能谱,对GAGG:Ce与Na I(TI)闪烁体探测器的温漂、能量线性及能量分辨率等性能指标重点进行了讨论。结果表明:GAGG:Ce探测器随温度漂移变化程度较大;能量线性好,线性相关度r为0.9999;对662 ke V的γ射线能量分辨率为7.8~8.0%。
文摘闪烁体探测器γ能谱测量中,闪烁光子的产生、传输及光电器件收集、倍增均对能谱的分辨有巨大影响。为了精确模拟闪烁体探测器的能量分辨,采用蒙特卡洛模拟软件GEANT4建立了一套模型,分别对Na I(TI),LaBr_3:0.5%Ce^(3+)闪烁体探测器测量能量为662 ke V的γ射线能谱进行模拟,获得的结果与实验测试结果能够很好的符合,验证了建立模型合理性与可靠性,为闪烁体的设计提供了一套更精确的开发工具。
基金Xi’an Jiaotong University and was fully supported by key research and development plan of Shandong Province(No.2017CXGC0916)and the Chinese government
文摘This report presents a design system based on the use of CsI(TI) detectors to search for lost radioactive sources that are dangerous and harmful to individuals, including searching persons. For this purpose, the GEANT4 simulation toolkit was utilized to develop a system based on three detectors. Various simulated analyses were performed on the dose rates of the three detectors using different source–detector distances and detector separation. There were good agreement between the simulated results and the experimentally measured data. A new method was discussed to detect and search for radioactive sources based only on the dose rates in detectors with source activity. Numerical analyses were performed based on the measured dose rates and the difference of distances to determine the actual location of the lost single or multiple γ-ray sources at a specific angle. The detection limit was calculated from the background radiation to establish the sensitivity and capability of the proposed detector system. This system can be applied in fields in which it is necessary to locate unknown radioactive sources.
基金supported by the National Natural Science Foundation of China(No.41474107)
文摘A Levenberg–Marquardt Gaussian fitting algorithm has been used for analyzing the overlap of three peaks(the 583-ke V peak of^(208)Tl, the 609-ke V peak of214 Bi, and the 662-ke V peak of^(137)Cs) using an in situ Na I(Tl) scintillation spectrometer. The algorithm, in addition,was compared with a genetic algorithm used for multiple deconvolution. The three fitted peak areas(583, 609, and662 ke V) were calculated from the measured gamma-ray spectra obtained from a simulation experiment in which a^(137) Cs source was buried at different soil depths(from 18 to38 cm). The application of the Levenberg–Marquardt algorithm yielded similar results compared to the genetic algorithm. A lack-of-fit test showed that the fitting is good when the instrumental noise levels were estimated from replicated analyses. The relative fitting error of the total net area and the residual standard deviation were within 5 %and 0.04, respectively, and the goodness of the fitting was better than 0.98. While the methods used in this paper give high performance, the results may lead to incorrect estimation when the signal-to-noise ratio is smaller than-30 d B. This study is useful for the determination of radioactive specific activity of^(137) Cs by in situ spectrometry.
基金This work was supported by the National Key Research and Development Program(Nos.2022YFB3503600 and 2021YFA0718500)Strategic Priority Research Program of the Chinese Academy of Sciences(Nos.XDA15360102)National Natural Science Foundation of China(Nos.12273042 and 12075258).
文摘The GECAM series of satellites utilizes LaBr_(3)(Ce),LaBr_(3)(Ce,Sr),and NaI(Tl)crystals as sensitive materials for gamma-ray detectors(GRDs).To investigate the nonlinearity in the detection of low-energy gamma rays and address the errors in the calibration of the E-C relationship,comprehensive tests and comparative studies of the three aforementioned crystals were conducted using Compton electrons,radioactive sources,and mono-energetic X-rays.The nonlinearity test results of the Compton electrons and X-rays demonstrated substantial differences,with all three crystals presenting a higher nonlinearity for X/-rays than for Compton electrons.Despite the LaBr_(3)(Ce)and LaBr_(3)(Ce,Sr)crystals having higher absolute light yields,they exhibited a noticeable nonlinear decrease in the light yield,especially at energies below 400 keV.The NaI(Tl)crystal demonstrated an"excess"light output in the 6-200 keV range,reaching a maximum"excess"of 9.2%at 30 keV in the X-ray testing and up to 15.5%at 14 keV during Compton electron testing,indicating a significant advantage in the detection of low-energy gamma rays.Furthermore,we explored the underlying causes of the observed nonlinearity in these crystals.This study not only elucidates the detector responses of GECAM,but also initiates a comprehensive investigation of the nonlinearity of domestically produced lanthanum bromide and sodium iodide crystals.