A Levenberg–Marquardt Gaussian fitting algorithm has been used for analyzing the overlap of three peaks(the 583-ke V peak of^(208)Tl, the 609-ke V peak of214 Bi, and the 662-ke V peak of^(137)Cs) using an in situ Na ...A Levenberg–Marquardt Gaussian fitting algorithm has been used for analyzing the overlap of three peaks(the 583-ke V peak of^(208)Tl, the 609-ke V peak of214 Bi, and the 662-ke V peak of^(137)Cs) using an in situ Na I(Tl) scintillation spectrometer. The algorithm, in addition,was compared with a genetic algorithm used for multiple deconvolution. The three fitted peak areas(583, 609, and662 ke V) were calculated from the measured gamma-ray spectra obtained from a simulation experiment in which a^(137) Cs source was buried at different soil depths(from 18 to38 cm). The application of the Levenberg–Marquardt algorithm yielded similar results compared to the genetic algorithm. A lack-of-fit test showed that the fitting is good when the instrumental noise levels were estimated from replicated analyses. The relative fitting error of the total net area and the residual standard deviation were within 5 %and 0.04, respectively, and the goodness of the fitting was better than 0.98. While the methods used in this paper give high performance, the results may lead to incorrect estimation when the signal-to-noise ratio is smaller than-30 d B. This study is useful for the determination of radioactive specific activity of^(137) Cs by in situ spectrometry.展开更多
The Na I:Tl scintillator is an innovative material for dual-gamma-ray and neutron detection with a low ^(6)Li concentration.To achieve real-time n/γ discrimination,a zero-crossing time comparison algorithm based on t...The Na I:Tl scintillator is an innovative material for dual-gamma-ray and neutron detection with a low ^(6)Li concentration.To achieve real-time n/γ discrimination,a zero-crossing time comparison algorithm based on trapezoidal pulse shaping was developed.The algorithm can operate efficiently at low sampling rates and was implemented on a single-probe portable digital n/γ discriminator based on a field-programmable gate array.The discriminator and Na I:Tl,^(6)Li detector were tested in a neutron-gamma mixed field produced by an ^(241)Am-Be neutron source to evaluate the performance of the algorithm.The figure of merits was measured as 2.88 at a sampling rate of 50 MHz,indicating that the discriminator with its embedded algorithm has a promising n/γ discrimination capability.Efficient discrimination at sampling rates of 40 and 25 MHz demonstrates that the capability of this method is not limited by low sampling rates.展开更多
基金supported by the National Natural Science Foundation of China(No.41474107)
文摘A Levenberg–Marquardt Gaussian fitting algorithm has been used for analyzing the overlap of three peaks(the 583-ke V peak of^(208)Tl, the 609-ke V peak of214 Bi, and the 662-ke V peak of^(137)Cs) using an in situ Na I(Tl) scintillation spectrometer. The algorithm, in addition,was compared with a genetic algorithm used for multiple deconvolution. The three fitted peak areas(583, 609, and662 ke V) were calculated from the measured gamma-ray spectra obtained from a simulation experiment in which a^(137) Cs source was buried at different soil depths(from 18 to38 cm). The application of the Levenberg–Marquardt algorithm yielded similar results compared to the genetic algorithm. A lack-of-fit test showed that the fitting is good when the instrumental noise levels were estimated from replicated analyses. The relative fitting error of the total net area and the residual standard deviation were within 5 %and 0.04, respectively, and the goodness of the fitting was better than 0.98. While the methods used in this paper give high performance, the results may lead to incorrect estimation when the signal-to-noise ratio is smaller than-30 d B. This study is useful for the determination of radioactive specific activity of^(137) Cs by in situ spectrometry.
基金This work was supported by the National Natural Science Foundation of China(NSFC)(No.12075308).
文摘The Na I:Tl scintillator is an innovative material for dual-gamma-ray and neutron detection with a low ^(6)Li concentration.To achieve real-time n/γ discrimination,a zero-crossing time comparison algorithm based on trapezoidal pulse shaping was developed.The algorithm can operate efficiently at low sampling rates and was implemented on a single-probe portable digital n/γ discriminator based on a field-programmable gate array.The discriminator and Na I:Tl,^(6)Li detector were tested in a neutron-gamma mixed field produced by an ^(241)Am-Be neutron source to evaluate the performance of the algorithm.The figure of merits was measured as 2.88 at a sampling rate of 50 MHz,indicating that the discriminator with its embedded algorithm has a promising n/γ discrimination capability.Efficient discrimination at sampling rates of 40 and 25 MHz demonstrates that the capability of this method is not limited by low sampling rates.