The AERORail, a new aerial transport platform, was chosen as the object of this work. Following a review of the literature on static behaviors, model tests on the basic dynamic mechanical characteristics were conducte...The AERORail, a new aerial transport platform, was chosen as the object of this work. Following a review of the literature on static behaviors, model tests on the basic dynamic mechanical characteristics were conducted. A series of 90 tests were completed with different factors, including tension force, vehicle load and vehicle speed. With regard to the proper tension and vehicle load, at a certain speed range, the tension increments of the rail's cable were proved relatively small. It can be assumed that the change of tension is small and can be reasonably ignored when the tension of an entire span is under a dynamic load. When the tension reaches a certain range, the calculation of the cable track structure using classical cable theory is acceptable. The tests prove that the average maximum dynamic amplification factor of the deflection is small, generally no more than 1.2. However, when the vehicle speed reaches a certain value, the amplified factor will reach 2.0. If the moving loads increase, the dynamic amplification factor of dynamic deflection will also increase. The tension will change the rigidity of the structure and the vibration frequency; furthermore, the resonance speed will change at a certain tension. The vibration is noticeable when vehicles pass through at the resonance speed, and this negative impact on driving comfort requires the right velocity to avoid the resonance. The results demonstrate that more design details are required for the AERORail structure.展开更多
Based on our previous pulsed current and internal overvoltage test data and the experience of common commercial high power cables,a 100 kA coaxial pulsed power cable is designed and manufactured to adapt the coaxial e...Based on our previous pulsed current and internal overvoltage test data and the experience of common commercial high power cables,a 100 kA coaxial pulsed power cable is designed and manufactured to adapt the coaxial electric energy breech transmission between the plasma generator and the pulsed power supply(PPS) in electrothermal-chemical(ETC) guns.The index parameters are analyzed and determined.Semi-conductor layers and a shield stiffener are introduced to prevent the deformation and burst of the pulsed power cable structurally.The semi-conductor layer can eliminate the air gap and balance the electric field in the cable.The shield stiffener can multiply the mechanical strength to restrain the strong electrodynamic force produced by the core dislocation of the outer conductor.The multi-coupling of electromagnetic field,stress field and thermal field analysis are established to assist in aided design of electrical strength,mechanical strength and temperature rise characteristics.Both a DC voltage withstand test and pulsed discharge tests are introduced to verify and inspect the performance and dynamic response of the pulsed power cable.The 25 kV/5 min DC voltage withstand test result shows that the sample leakage current is nearly 3 μA and no abnormal phenomena of the pulsed power cable sample occurred.The pulsed discharge tests show that the sample can sustain the 100 kA peak current.Furthermore,this 100 kA coaxial pulsed power cable can satisfy the ETC test requirements.展开更多
基金Projects(50708072,51378385)supported by the National Natural Science Foundation of China
文摘The AERORail, a new aerial transport platform, was chosen as the object of this work. Following a review of the literature on static behaviors, model tests on the basic dynamic mechanical characteristics were conducted. A series of 90 tests were completed with different factors, including tension force, vehicle load and vehicle speed. With regard to the proper tension and vehicle load, at a certain speed range, the tension increments of the rail's cable were proved relatively small. It can be assumed that the change of tension is small and can be reasonably ignored when the tension of an entire span is under a dynamic load. When the tension reaches a certain range, the calculation of the cable track structure using classical cable theory is acceptable. The tests prove that the average maximum dynamic amplification factor of the deflection is small, generally no more than 1.2. However, when the vehicle speed reaches a certain value, the amplified factor will reach 2.0. If the moving loads increase, the dynamic amplification factor of dynamic deflection will also increase. The tension will change the rigidity of the structure and the vibration frequency; furthermore, the resonance speed will change at a certain tension. The vibration is noticeable when vehicles pass through at the resonance speed, and this negative impact on driving comfort requires the right velocity to avoid the resonance. The results demonstrate that more design details are required for the AERORail structure.
基金supported by the United Foundation of China Ordnance Industry(Grant No.6141B010220)
文摘Based on our previous pulsed current and internal overvoltage test data and the experience of common commercial high power cables,a 100 kA coaxial pulsed power cable is designed and manufactured to adapt the coaxial electric energy breech transmission between the plasma generator and the pulsed power supply(PPS) in electrothermal-chemical(ETC) guns.The index parameters are analyzed and determined.Semi-conductor layers and a shield stiffener are introduced to prevent the deformation and burst of the pulsed power cable structurally.The semi-conductor layer can eliminate the air gap and balance the electric field in the cable.The shield stiffener can multiply the mechanical strength to restrain the strong electrodynamic force produced by the core dislocation of the outer conductor.The multi-coupling of electromagnetic field,stress field and thermal field analysis are established to assist in aided design of electrical strength,mechanical strength and temperature rise characteristics.Both a DC voltage withstand test and pulsed discharge tests are introduced to verify and inspect the performance and dynamic response of the pulsed power cable.The 25 kV/5 min DC voltage withstand test result shows that the sample leakage current is nearly 3 μA and no abnormal phenomena of the pulsed power cable sample occurred.The pulsed discharge tests show that the sample can sustain the 100 kA peak current.Furthermore,this 100 kA coaxial pulsed power cable can satisfy the ETC test requirements.