Corrosion behaviour and biofouling characteristics of mild steel in three different coastal locations in the Gulf of Mannar,India have been studied over a period of 24 months.Oyster fouling was predominant at Open sea...Corrosion behaviour and biofouling characteristics of mild steel in three different coastal locations in the Gulf of Mannar,India have been studied over a period of 24 months.Oyster fouling was predominant at Open sea-Tuticorin,while barnacle fouling was dominant at both Mandapam and Harbour-Tuticorin.The rate of corrosion for 24 months exposure period was highest at Mandapam,where fouling was minimal.The surface of the mild steel was characterized by etchings&crevices beneath the hard foulers attached on it,at all the test locations.The depth of crevice caused by hard foulers was higher at Open sea-Tuticorin followed by Harbour-Tuticorin and Mandapam.The loss in ultimate tensile strength was more in Open sea-Tuticorin than the other two locations.Corrosion behaviour of mild steel is discussed based on the variation in the biofouling assemblage at the three test locations.展开更多
Membrane fouling is the main problem of membrane bioreactors (MBR), which seriously influ- ences its wastewater treatment effect and running. The characteristics of microbiology and hydrodynamics concerning membrane f...Membrane fouling is the main problem of membrane bioreactors (MBR), which seriously influ- ences its wastewater treatment effect and running. The characteristics of microbiology and hydrodynamics concerning membrane fouling were investigated and the measure was put forward for optimum operation of MBR. The measure is that 1) the parameters of activated sludge concentration (X) and membrane flux should be lower than the critical values of X and membrane flux respectively, and 2) the activated sludge should be discharged periodically. The experimental results show that the combination backwashing of gas and perme- ated effluent is better than single gas backwashing or single permeated effluent backwashing. This technique can remove the cake layer deposited on the membrane surface, decrease the membrane fouling, and recover the membrane flux effectively. So it is effective for prevention of membrane fouling.展开更多
High-alkali species in coal are notorious for causing ash slagging and fouling incidents.In this paper,four high-alkali coals were individually subject to hydrothermal pretreatment(HTP),within a batch-type autoclave a...High-alkali species in coal are notorious for causing ash slagging and fouling incidents.In this paper,four high-alkali coals were individually subject to hydrothermal pretreatment(HTP),within a batch-type autoclave at 300 -C for 1 h,and the treated coals were analyzed,along with the oxygen-containing functional groups determined by Fourier transform infrared spectrometer(FT-IR).Then the alkali species and other components in the coal ash were quantified by X-ray fluorescence(XRF)for evaluating the ash slagging and fouling tendency.Apart from this,FactSage was adopted to simulate the occurrence and transformation of alkali species during coal thermal conversion ending at various temperatures.The findings indicate that the treated coals are superior to the parent ones in terms of certain remarkable changes via HTP.The moisture,oxygen and sulfur of the hydrothermally treated coals decline obviously,while the calorific value rises sharply.HTP could reduce the alkali species to less than 2%(%,by weight,equivalent to Na2O in dry ash),with a maximum removal ratio of 88.9%,lowering the ash slagging and fouling tendency.The proposed mechanism of HTP was that the alkali species in coal matrix became released due to the breakage of the coal functional groups and micropores during HTP.展开更多
The characteristics of membrane fouling and cleaning, in a hybrid MBR process, was investigated. Under the condition of sub-critical flux operation, a characteristic three-stage trans-membrane pressure (TMP) profile...The characteristics of membrane fouling and cleaning, in a hybrid MBR process, was investigated. Under the condition of sub-critical flux operation, a characteristic three-stage trans-membrane pressure (TMP) profile is observed as time passes. The initially extended period of slow pressure rise, followed by a somewhat faster rise, is then sup- planted by a sudden transition to rapid pressure rise. Membrane cleaning experiments and SEM examination make it apparent that the rapid TMP rise is mainly caused by the accumulation of a surface cake layer, which is a reversible fouling that can be removed by tap water washing. Fouling caused by a gel layer, which is an irreversible fouling, can be removed efficiently by chemical cleaning. NaC10 can oxidize the gel layer, which is formed mainly of macromo-lecular organic substances. The HC1 can remove inorganic particles formed by Ca^2+, Mg^2+ ions etc. The sequence of chemicals used in membrane cleaning has an influence on the cleaning result. The effect of the NaC1O+HC1 cleaning procedure is superior to that of the HCI+NaC1O one. Particle size distribution measurements (PSD) reveal that fine particles are inclined to deposit or attach on the membrane surface, or in the membrane pores, and caused rapid fouling.展开更多
A study on heat transfer performance by thermal fluid coupling simulation for the fouling in a shell-tube heat exchanger used in engineering was presented. The coupling simulation was performed in a fluid and solid do...A study on heat transfer performance by thermal fluid coupling simulation for the fouling in a shell-tube heat exchanger used in engineering was presented. The coupling simulation was performed in a fluid and solid domains under three different fouling conditions: fouling inside the tube, fouling outside the tube, and fouling inside the shell. The flow field, temperature, and pressure distributions in the heat exchanger were solved numerically to analyze the heat transfer performance parameters, such as thermal resistance. It is found that the pressure drop of the heat exchanger and the thermal resistance of the tube wall increase by nearly 30% and 20%, respectively, when the relative fouling thickness reaches 10%. The fouling inside the tube has more impact on the heat transfer performance of the heat exchanger, and the fouling inside the shell has less impact.展开更多
In the present study an attempt has been made to investigate the relationship between the variations in the fouling assemblage and corrosion behaviour of HSLA steel at three coastal locations in the Gulf of Mannar, In...In the present study an attempt has been made to investigate the relationship between the variations in the fouling assemblage and corrosion behaviour of HSLA steel at three coastal locations in the Gulf of Mannar, India, over a period of 24 months. Oyster fouling was dominant in the Tuticorin open sea, while barnacles were the major foulants in the Tuticorin harbour and Mandapam. The fouling load in the Tuticorin waters was higher when compared to the Mandapam waters. The corrosion rates decreased progressively with the immersion time at all three test locations. In the Tuticorin open sea, the corrosion rates were higher when compared to the other two locations throughout the study period. The surface of the coupons was characterized by crevices beneath the hard foulers in the Tuticorin harbour and Mandapam, whereas in the Tuticorin open sea, the coupons experienced crevices of a tunneling nature. The percentage of the loss of the tensile strength increased with time at all the test locations.展开更多
The catalytic combustion technology for treating waste gases exiting from wastewater treatment system and oil separators in petrochemical enterprises was introduced in this article. Commercial application of this tech...The catalytic combustion technology for treating waste gases exiting from wastewater treatment system and oil separators in petrochemical enterprises was introduced in this article. Commercial application of this technology showed that the process "desulfurization and total hydrocarbon concentration homogenizationcatalytic combustion" and the associated WSH-1 combustion catalyst were suitable for treating volatile organic gases emitted from the oil separators, floatation tanks, inlet water-collecting well, waste oil tanks, etc. The commercial unit was equipped with an advanced auto-control system, featuring a simple operation and low energy consumption with good treatment effect. The purified gases could meet the national emission standard.展开更多
In January 2021,a fire broke out in the apartment where Russian rhythmic gymnast and Olympic champion Daria Valeryevna Shkurikhina lived.But surprisingly,Daria's Beijing 2008 Olympic Games gold medal,down to its r...In January 2021,a fire broke out in the apartment where Russian rhythmic gymnast and Olympic champion Daria Valeryevna Shkurikhina lived.But surprisingly,Daria's Beijing 2008 Olympic Games gold medal,down to its ribbons,was left almost intact in the fire.The medal ribbon of Beijing 2008 Olympic Games is through high-tech nano treatment,not only waterproof,mothproof,antifouling,fire,and never fade.展开更多
The rapid growth in railway infrastructure and the construction of high-speed heavy-haul rail network,especially on ground that is basically unsuitable,poses challenges for geotechnical engineers because a large part ...The rapid growth in railway infrastructure and the construction of high-speed heavy-haul rail network,especially on ground that is basically unsuitable,poses challenges for geotechnical engineers because a large part of the money invested in the development of railway lines is often spent on track maintenance.In fact around the world,the mud pumping of subgrade fines is one of the common reasons why track performance deteriorates and track stability is hindered.This article presents a series of laboratory tests to examine following aspects of mud pumping:(1)the mechanisms of subgrade fluidisation under undrained condition,(2)the effects of mud pumping on the engineering characteristics of ballast,and(3)the use of vertical drains to stabilize subgrade under cyclic loads.The undrained cyclic triaxial testing on vulnerable soft subgrade was performed by varying the cyclic stress ratio(CSR)from 0.2 to 1.0 and the loading frequency f from 1.0 to 5.0 Hz.It is seen from the test results that for a specimen compacted at an initial dry density of 1790 kg/m3,the top portion of the specimen fluidises at CSR=0.5,irrespective of the applied loading frequency.Under cyclic railway loading,the internal redistribution of water at the top of the subgrade layer softens the soil and also reduces its stiffness.In response to these problems,this paper explains how the inclusion of vertical drains in soft subgrade will help to prevent mud pumping by alleviating the build-up of excess pore pressures under moving train loads.展开更多
基金Supported by the Ministry of Environment and Forests,New Delhi(Project Grant No.19-26/2003-RE)
文摘Corrosion behaviour and biofouling characteristics of mild steel in three different coastal locations in the Gulf of Mannar,India have been studied over a period of 24 months.Oyster fouling was predominant at Open sea-Tuticorin,while barnacle fouling was dominant at both Mandapam and Harbour-Tuticorin.The rate of corrosion for 24 months exposure period was highest at Mandapam,where fouling was minimal.The surface of the mild steel was characterized by etchings&crevices beneath the hard foulers attached on it,at all the test locations.The depth of crevice caused by hard foulers was higher at Open sea-Tuticorin followed by Harbour-Tuticorin and Mandapam.The loss in ultimate tensile strength was more in Open sea-Tuticorin than the other two locations.Corrosion behaviour of mild steel is discussed based on the variation in the biofouling assemblage at the three test locations.
文摘Membrane fouling is the main problem of membrane bioreactors (MBR), which seriously influ- ences its wastewater treatment effect and running. The characteristics of microbiology and hydrodynamics concerning membrane fouling were investigated and the measure was put forward for optimum operation of MBR. The measure is that 1) the parameters of activated sludge concentration (X) and membrane flux should be lower than the critical values of X and membrane flux respectively, and 2) the activated sludge should be discharged periodically. The experimental results show that the combination backwashing of gas and perme- ated effluent is better than single gas backwashing or single permeated effluent backwashing. This technique can remove the cake layer deposited on the membrane surface, decrease the membrane fouling, and recover the membrane flux effectively. So it is effective for prevention of membrane fouling.
基金the National Key Basic Research Program of China (No. 2014CB238905)
文摘High-alkali species in coal are notorious for causing ash slagging and fouling incidents.In this paper,four high-alkali coals were individually subject to hydrothermal pretreatment(HTP),within a batch-type autoclave at 300 -C for 1 h,and the treated coals were analyzed,along with the oxygen-containing functional groups determined by Fourier transform infrared spectrometer(FT-IR).Then the alkali species and other components in the coal ash were quantified by X-ray fluorescence(XRF)for evaluating the ash slagging and fouling tendency.Apart from this,FactSage was adopted to simulate the occurrence and transformation of alkali species during coal thermal conversion ending at various temperatures.The findings indicate that the treated coals are superior to the parent ones in terms of certain remarkable changes via HTP.The moisture,oxygen and sulfur of the hydrothermally treated coals decline obviously,while the calorific value rises sharply.HTP could reduce the alkali species to less than 2%(%,by weight,equivalent to Na2O in dry ash),with a maximum removal ratio of 88.9%,lowering the ash slagging and fouling tendency.The proposed mechanism of HTP was that the alkali species in coal matrix became released due to the breakage of the coal functional groups and micropores during HTP.
基金Projects 200457 supported by the Planning Foundation of Hebei Water Conservancy Bureau in ChinaOP4476 by the Youth Foundation of China Univer- sity of Mining & Technology
文摘The characteristics of membrane fouling and cleaning, in a hybrid MBR process, was investigated. Under the condition of sub-critical flux operation, a characteristic three-stage trans-membrane pressure (TMP) profile is observed as time passes. The initially extended period of slow pressure rise, followed by a somewhat faster rise, is then sup- planted by a sudden transition to rapid pressure rise. Membrane cleaning experiments and SEM examination make it apparent that the rapid TMP rise is mainly caused by the accumulation of a surface cake layer, which is a reversible fouling that can be removed by tap water washing. Fouling caused by a gel layer, which is an irreversible fouling, can be removed efficiently by chemical cleaning. NaC10 can oxidize the gel layer, which is formed mainly of macromo-lecular organic substances. The HC1 can remove inorganic particles formed by Ca^2+, Mg^2+ ions etc. The sequence of chemicals used in membrane cleaning has an influence on the cleaning result. The effect of the NaC1O+HC1 cleaning procedure is superior to that of the HCI+NaC1O one. Particle size distribution measurements (PSD) reveal that fine particles are inclined to deposit or attach on the membrane surface, or in the membrane pores, and caused rapid fouling.
基金National Natural Science Foundation of China (21878102)
文摘A study on heat transfer performance by thermal fluid coupling simulation for the fouling in a shell-tube heat exchanger used in engineering was presented. The coupling simulation was performed in a fluid and solid domains under three different fouling conditions: fouling inside the tube, fouling outside the tube, and fouling inside the shell. The flow field, temperature, and pressure distributions in the heat exchanger were solved numerically to analyze the heat transfer performance parameters, such as thermal resistance. It is found that the pressure drop of the heat exchanger and the thermal resistance of the tube wall increase by nearly 30% and 20%, respectively, when the relative fouling thickness reaches 10%. The fouling inside the tube has more impact on the heat transfer performance of the heat exchanger, and the fouling inside the shell has less impact.
基金Supported by the Ministry of Environment and Forests,New Delhi for the Financial Support(Project Grant No.19-26/2003-RE)
文摘In the present study an attempt has been made to investigate the relationship between the variations in the fouling assemblage and corrosion behaviour of HSLA steel at three coastal locations in the Gulf of Mannar, India, over a period of 24 months. Oyster fouling was dominant in the Tuticorin open sea, while barnacles were the major foulants in the Tuticorin harbour and Mandapam. The fouling load in the Tuticorin waters was higher when compared to the Mandapam waters. The corrosion rates decreased progressively with the immersion time at all three test locations. In the Tuticorin open sea, the corrosion rates were higher when compared to the other two locations throughout the study period. The surface of the coupons was characterized by crevices beneath the hard foulers in the Tuticorin harbour and Mandapam, whereas in the Tuticorin open sea, the coupons experienced crevices of a tunneling nature. The percentage of the loss of the tensile strength increased with time at all the test locations.
文摘The catalytic combustion technology for treating waste gases exiting from wastewater treatment system and oil separators in petrochemical enterprises was introduced in this article. Commercial application of this technology showed that the process "desulfurization and total hydrocarbon concentration homogenizationcatalytic combustion" and the associated WSH-1 combustion catalyst were suitable for treating volatile organic gases emitted from the oil separators, floatation tanks, inlet water-collecting well, waste oil tanks, etc. The commercial unit was equipped with an advanced auto-control system, featuring a simple operation and low energy consumption with good treatment effect. The purified gases could meet the national emission standard.
文摘In January 2021,a fire broke out in the apartment where Russian rhythmic gymnast and Olympic champion Daria Valeryevna Shkurikhina lived.But surprisingly,Daria's Beijing 2008 Olympic Games gold medal,down to its ribbons,was left almost intact in the fire.The medal ribbon of Beijing 2008 Olympic Games is through high-tech nano treatment,not only waterproof,mothproof,antifouling,fire,and never fade.
基金This research was supported by the Australian Government through the Australian Research Council’s Linkage Projects funding scheme(Project LP160101254)the Industrial Transformation Training Centre for Advanced Technologies in Rail Track Infrastructure(ITTC),University of WollongongThe financial and technical support from SMEC-Australia and ARTC(Australian Rail Track Corporation)is acknowledged.
文摘The rapid growth in railway infrastructure and the construction of high-speed heavy-haul rail network,especially on ground that is basically unsuitable,poses challenges for geotechnical engineers because a large part of the money invested in the development of railway lines is often spent on track maintenance.In fact around the world,the mud pumping of subgrade fines is one of the common reasons why track performance deteriorates and track stability is hindered.This article presents a series of laboratory tests to examine following aspects of mud pumping:(1)the mechanisms of subgrade fluidisation under undrained condition,(2)the effects of mud pumping on the engineering characteristics of ballast,and(3)the use of vertical drains to stabilize subgrade under cyclic loads.The undrained cyclic triaxial testing on vulnerable soft subgrade was performed by varying the cyclic stress ratio(CSR)from 0.2 to 1.0 and the loading frequency f from 1.0 to 5.0 Hz.It is seen from the test results that for a specimen compacted at an initial dry density of 1790 kg/m3,the top portion of the specimen fluidises at CSR=0.5,irrespective of the applied loading frequency.Under cyclic railway loading,the internal redistribution of water at the top of the subgrade layer softens the soil and also reduces its stiffness.In response to these problems,this paper explains how the inclusion of vertical drains in soft subgrade will help to prevent mud pumping by alleviating the build-up of excess pore pressures under moving train loads.