In this paper,a composite numerical scheme is proposed to solve the threedimensional Darcy-Forchheimer miscible displacement problem with positive semi-definite assumptions.A mixed finite element is used for the fow e...In this paper,a composite numerical scheme is proposed to solve the threedimensional Darcy-Forchheimer miscible displacement problem with positive semi-definite assumptions.A mixed finite element is used for the fow equation.The velocity and pressure are computed simultaneously.The accuracy of velocity is improved one order.The concentration equation is solved by using mixed finite element,multi-step difference and upwind approximation.A multi-step method is used to approximate time derivative for improving the accuracy.The upwind approximation and an expanded mixed finite element are adopted to solve the convection and diffusion,respectively.The composite method could compute the diffusion flux and its gradient.It possibly becomes an eficient tool for solving convection-dominated diffusion problems.Firstly,the conservation of mass holds.Secondly,the multi-step method has high accuracy.Thirdly,the upwind approximation could avoid numerical dispersion.Using numerical analysis of a priori estimates and special techniques of differential equations,we give an error estimates for a positive definite problem.Numerical experiments illustrate its computational efficiency and feasibility of application.展开更多
In order to analyze the electrostatic field concerned with electrostatic proximity fuze problem using the available finite analysis software package, the technology to model the problem with a scale reduction object a...In order to analyze the electrostatic field concerned with electrostatic proximity fuze problem using the available finite analysis software package, the technology to model the problem with a scale reduction object and boundary was presented. The boundary is determined by the maximum distance the sensor can detect. The object model is obtained by multiplying the terms in Poisson's equation with a scale reduction factor and the real value can be reconstructed with the same reverse process after software calculation. Using the finite element analysis program, the simulation value is close to the theoretical value with a little error. The boundary determination and scale reduction method is suitable to modeling the irregular electrostatic field around air targets, such as airplane, missile and so on, which is based on commonly used personal computer (PC). The technology reduces the calculation and storage cost greatly.展开更多
With the increase of pipelines, corrosion leakage accidents happen frequently. Therefore, nondestructive testing technology is important for ensuring the safe operation of the pipelines and energy mining. In this pape...With the increase of pipelines, corrosion leakage accidents happen frequently. Therefore, nondestructive testing technology is important for ensuring the safe operation of the pipelines and energy mining. In this paper, the structure and principle of magnetic flux leakage (MFL) in-line inspection system is introduced first. Besides, a mathematic model of the system according to the ampere circuit rule, flux continuity theorem, and column coordinate transform is built, and the magnetic flux density in every point of space is calculated based on the theory of finite element analysis. Then we analyze and design the disposition of measurement section probes and sensors combining both three-axis MFL in-line inspection and multi-sensor fusion technology. Its advantage is that the three-axis changes of magnetic flux leakage field are measured by the multi-probes at the same time, so we can determine various defects accurately. Finally, the theory of finite element analysis is used to build a finite element simulation model, and the relationship between defects and MFL inspection signals is studied. Simulation and experiment results verify that the method not only enhances the detection ability to different types of defects but also improves the precision and reliability of the inspection system.展开更多
Objective: To treat humerus fracture with three dimensional pattern and finite element analysis, providing mechanical basis for treating humerus fracture. Methods: Humerus pattern was established based on the CT image...Objective: To treat humerus fracture with three dimensional pattern and finite element analysis, providing mechanical basis for treating humerus fracture. Methods: Humerus pattern was established based on the CT images, and calculation was done by ANSYS5. 6 software. Three dimensional ten-node tetrahedron unit was selected and were divided into 2 729 nodes, 49 041 units. Distribution and amount of axial compression of humerus were analyzed when clip angle was 30°, 45°, 90° between fracture face and axial line with fixed X, Y, Z directions. Results: The distribution of stress was greatly different between fracture face and non fracture face. Stress in fracture part was fairly concentrated with incomplete symmetric distribution around the center of fracture face; Greater stress distributed in the regions 10 mm from fracture face, which was 2-3 times that of other stress regions. Conclusion: Required load must be estimated under various conditions as to select the suitable internal fixation implants during the treatment of humerus fracture, which can provide helpful stress environment for fracture healing.展开更多
A contact bolt model is proposed as a new modeling technique to investigate the complex structure with bolted joints for modal analysis and compared with the coupled bolt model, and the test results are given. Among t...A contact bolt model is proposed as a new modeling technique to investigate the complex structure with bolted joints for modal analysis and compared with the coupled bolt model, and the test results are given. Among these models, the coupled bolt model provides the best accurate responses compared with the experimental results. The contact bolt model shows the best effectiveness and usefulness in view of operational time. The bolt models proposed in this study are adopted for a dynamic characteristic analysis of a large diesel engine consisting of several parts which are connected by many bolts. The dynamic behavior of the entire engine structure was investigated by experiment. The coupled bolt model and the contact bolt model were applied to model the assembly of engine with high preload. The experimental results are in good agreement with the finite element method (FEM) results. Compared with the other models, the contact bolt model presented in this paper is more effective and useful in view of operational time and experience of analysts.展开更多
In this paper, an investigation into the propagation of far field explosion waves in water and their effects on nearby structures are carried out. For the far field structure, the motion of the fluid surrounding the s...In this paper, an investigation into the propagation of far field explosion waves in water and their effects on nearby structures are carried out. For the far field structure, the motion of the fluid surrounding the structure may be assumed small, allowing linearization of the governing fluid equations. A complete analysis of the problem must involve simultaneous solution of the dynamic response of the structure and the propagation of explosion wave in the surrounding fluid. In this study, a dynamic adaptive finite element procedure is proposed. Its application to the solution of a 2D fluid-structure interaction is investigated in the time domain. The research includes:a) calculation of the far-field scatter wave due to underwater explosion including solution of the time-depended acoustic wave equation, b) fluid-structure interaction analysis using coupled Euler-Lagrangian approach, and c) adaptive finite element procedures employing error estimates, and re-meshing. The temporal mesh adaptation is achieved by local regeneration of the grid using a time-dependent error indicator based on curvature of pressure function. As a result, the overall response is better predicted by a moving mesh than an equivalent uniform mesh. In addition, the cost of computation for large problems is reduced while the accuracy is improved.展开更多
A new type of soft actuator material-ionic liquid gel (ILG), which consists of HEMA, BMIMBF4, and TiO2, can be transformed into gel state under the irradiation of ultraviolet (UV) light. In this paper, Mooney-Rivl...A new type of soft actuator material-ionic liquid gel (ILG), which consists of HEMA, BMIMBF4, and TiO2, can be transformed into gel state under the irradiation of ultraviolet (UV) light. In this paper, Mooney-Rivlin hyperelastic model of finite element method is proposed for the first time to study the properties of the ILG. It has been proved that the content of TiO2 has a great influence on the properties of the gel, and Young's modulus of the gel increases with the increase of its content, despite of reduced tensile deformation. The results in this work show that when the TiO2 content is 1.0 wt%, a large tensile deformation and a strong Young's modulus can be obtained to be 325% and 7.8 kPa, respectively. The material parameters of ILG with TiO2 content values of 0.2 wt%, 0.5 wt%, 1.0 wt%, and 1.5 wt% are obtained, respectively, through uniaxial tensile tests, including C10, C01, C20, C11, C02, C30, C21, C12, and C03 elements. In this paper, the large-scaled general finite element software ANSYS is used to simulate and analyze the ILG, which is based on SOLID186 element and nonlinear hyperelastic Mooney-Rivlin model. The finite element simulation analysis based stress-strain curves are almost consistent with the experimental stress-strain curves, and hence the finite element analysis of ILG is feasible and credible. This work presents a new direction for studying the performance of soft actuator for the ILG, and also contributes to the design of soft robot actuator.展开更多
Natural fiber composites have been proved to have the ability to replace the synthetic fiber composites in many structural applications. Unprecedented growth in the field of computational techniques has opened the doo...Natural fiber composites have been proved to have the ability to replace the synthetic fiber composites in many structural applications. Unprecedented growth in the field of computational techniques has opened the doors of analysis and simulation of composite materials under various environment.Modelling and simulation using various available softwares saves a lot of time and resources. In the present work, an attempt has been made to analyze the tensile behavior of jute fiber reinforced epoxy based polymer composite materials using the student version of commercially available finite element code Siemens PLM NX 10.0. In most of the structural applications, materials are required to have enough stiffness to resist the shape deformation under normal loading conditions. Therefore, emphasis is given to the load-deformation behavior of the developed composites. A 3-dimensional model of the test specimen was developed using ply-stacking method and the strain-stress values were verified by the available literature. The model showed a good agreement between the experimental and software results. Effect of ply angle, fiber percentage, fiber type, number of layers and weft fiber angle on the stiffness of laminate have been studied.展开更多
Objective: To study the memory biomechanical character of anatomic distal radius Nitinol memory connector (DRMC) in treating distal radius fracture. Methods: Establishing three dimensional model and finite element ana...Objective: To study the memory biomechanical character of anatomic distal radius Nitinol memory connector (DRMC) in treating distal radius fracture. Methods: Establishing three dimensional model and finite element analysis, we calculated the stress in and around the fracture faces when distal radius fracture was fixated with DRMC. Results: Axial holding stress produced by holding part of DRMC on distal radius was 14.66 MPa. The maximum stress of holding part was 40-70 MPa, the minimum stress was 3-7 MPa,and the stress of compression part was 20-40 MPa. Conclusion: The distribution of stress produced by DRMC around the fracture line is reasonable, and axial holding stress can help stabilize fracture during earlier period. The existence of longitudal compression and memory effect can transfer fixated disused section into developed section and enhance fracture healing.展开更多
The hydro-hammer sampler is a new type of sampler compared with traditional ones. An important part of this new offshore sampler is that the structure of the core cutter has a significant effect on penetration and cor...The hydro-hammer sampler is a new type of sampler compared with traditional ones. An important part of this new offshore sampler is that the structure of the core cutter has a significant effect on penetration and core recovery. In our experiments, a commercial finite element code with a capability of simulating large-strain frictional contact between two or more solid bodies is used to simulate the core cutter-soil interaction. The effects of the cutting edge shape, the diameter and the edge angle on penetration are analyzed by non-liner transient dynamic analysis using a finite element method (FEM). Simulation results show that the cutter shape clearly has an effect on the penetration and core recovery. In addition, the penetration of the sampler increases with an increase in the inside diameter of the cutter, but decreases with an increase in the cutting angle. Based on these analyses, an optimum structure of the core cutter is designed and tested in the north margin of the Dalian gulf. Experiment results show that the penetration rate is about 16.5 m/h in silty clay and 15.4 m/h in cohesive clay, while the recovery is 68% and 83.3% resoectively.展开更多
To control the vibration level of ships under construction,MSC Software’s Patran&Nastran modeling solutions can be used to establish a detailed finite element model of a new manned submersible support mother ship...To control the vibration level of ships under construction,MSC Software’s Patran&Nastran modeling solutions can be used to establish a detailed finite element model of a new manned submersible support mother ship based on a line drawing,including the deck layout,bulkhead section,and stiffener distribution.After a comprehensive analysis of the ship simulation conditions,boundaries,and excitation forces of the main operating equipment,modal analysis and calculation of the ship vibration can be conducted.In this study,we calculated and analyzed the vibration response of key points in the stern area of the ship’s main deck and the submersible warehouse area under design loading working conditions.We then analyzed the vibration response of typical decks(including the compass deck,steering deck,captain’s deck,forecastle deck,and main deck)under the main excitation forces and moments(such as the full swing pod and generator sets).The analysis results showed that under DESIDEP working conditions,the vibration of each deck and key areas of the support mother ship could meet the vibration code requirements of the ship’s preliminary design(using the pod excitation and generator sets).Similarly,the vibration response of a scientific research ship under other loading conditions also met the requirements of the code and provided data support for a comprehensive understanding of the ship’s vibration and noise levels.Using actual vibration measurements,the accuracy of the vibration level simulations using finite element modeling was verified,the vibration of each area of the ship comfortably meeting the requirements of the China Classification Society.展开更多
The uniform design method was adopted and the twenty-four groups of different geometric and physical pa-rameters were chosen. The finite element model was built. Comparisons between the simulation results and the test...The uniform design method was adopted and the twenty-four groups of different geometric and physical pa-rameters were chosen. The finite element model was built. Comparisons between the simulation results and the test re-sults prove that the simulation results are correct. The distribution of the temperature field of the chimney foundationwas analyzed. The multivariate linear regression of the hightest tomperature was performed on the inner wall of thechimney foundation by the numerical calculated results. The fitting property of the highest temperature with six influ-ence factors was obtained. A simple method for the calculation of the temperature field of the chimney foundation wasprovided.展开更多
Objective:To explore the mechanical behavior of acetabulum loaded by static stress and provide the mechanical basis for clinical analysis and judgement on acetabular mechanical distribution and effect of static stress...Objective:To explore the mechanical behavior of acetabulum loaded by static stress and provide the mechanical basis for clinical analysis and judgement on acetabular mechanical distribution and effect of static stress.Methods:By means of computer simulation, acetabular three dimensional model was input into three dimensional finite element analysis software ANSYS7.0. The acetabular mechanical behavior was calculated and the main stress value, stress distribution and acetabular unit displacement in the direction of main stress were analyzed when anterior wall of acetabulum and acetabular crest were loaded by 1 000 N static stress. Results:When acetabular anterior wall loaded by X direction and Z direction composition force, the stress passed along 4 directions: (1)from acetabular anterior wall to pubic symphysis along superior branch of pubis firstly, (2)from acetabular anterior wall to cacroiliac joint along pelvic ring,(3)in the acetabulum,(4)from the suffered point to ischium. When acetabular crest loaded by X direction and Y direction composition force, the stress transmitted to 4 directions: (1)from acetabular crest to ilium firstly, (2)from suffered point to cacroiliac joint along pelvic ring,(3) in the acetabulum ,(4)along the pubic branch,but no stress transmitted to the ischium branch.Conclusion:Analyzing the stress distribution of acetabulum and units displacement when static stress loaded can provide internal fixation point for acetabular fracture treatment and help understand the stress distribution of acetabulum.展开更多
A dynamic finite element method combined with finite element mixed formula for contact problem is used to analyze the dynamic characteristics of gear system. Considering the stiffness excitation, error excitation and ...A dynamic finite element method combined with finite element mixed formula for contact problem is used to analyze the dynamic characteristics of gear system. Considering the stiffness excitation, error excitation and meshing shock excitation, the dynamic finite element model is established for the entire gear system which includes gears, shafts, bearings and gearbox housing. By the software of I-DEAS, the natural frequency, normal mode, dynamic time-domain response, frequency-domain response and one-third octave velocity grade structure borne noise of gear system are studied by the method of theoretical modal analysis and dynamic response analysis. The maximum values of vibration and structure borne noise are occurred at the mesh frequency of output grade gearing.展开更多
The finite element analysis of the fretting behavior between a cylinder block and a main bearing cap is presented. The stresses, relative fretting slip, frettin g friction work parameter W and crack initiation locatio...The finite element analysis of the fretting behavior between a cylinder block and a main bearing cap is presented. The stresses, relative fretting slip, frettin g friction work parameter W and crack initiation location parameter Gon the fretting contact surface of the cylinder block are obtained and analyzed. It shows that the fretting fatigue problem of the cylinder block can be quantitat ively explained by WorG. The effects of pretightening force, friction factor and material combination of the cylinder block and the main bearing cap are studied. The computational results indicate that the fretting fatigue of the cylinder block can be allayed by increasing the elastic modulus of the cylinder block, but not by changing the other two factors.展开更多
In recent years,actuators based on carbon nanotube(CNT) or graphene demonstrate great potential applications in the fields of artificial muscles,smart switches,robotics,and so on.The electrothermal and photothermal ...In recent years,actuators based on carbon nanotube(CNT) or graphene demonstrate great potential applications in the fields of artificial muscles,smart switches,robotics,and so on.The electrothermal and photothermal bending actuators based on CNT/graphene and polymer composites show large bending actuations,which are superior to traditional thermaldriven actuators.However,the influence of material parameters(thickness,temperature change,etc.) on the actuation performance needs to be further studied,because it is a critical point to the design and fabrication of high-performance actuators.In this work,finite element analysis(EEA) is employed to simulate the actuation performance of CNT/polymer actuator,which has a bilayer structure.The main focus of this work is to design and to optimize material parameters by using computational method.FEA simulation results show that each layer thickness of actuator has an important influence on the actuation deformation.A maximum curvature of 2.7 cm^(-1) is obtained by simulation,which is much larger than most of the actuator curvature reported in previous experiments.What is more,larger temperature change and larger difference of coefficient of thermal expansion(CTE) between two layers will result in larger bending actuation.This study is expected to provide valuable theoretical reference for the design and realization of CNT-based thermal actuator with ultra-large actuation performance.展开更多
To improve the performance of the 2 m telescope, the optimum design is applied to the telescope assemble. Referring to the telescope assemble with the dimetric truss, a group of reasonable sizes of the telescope assem...To improve the performance of the 2 m telescope, the optimum design is applied to the telescope assemble. Referring to the telescope assemble with the dimetric truss, a group of reasonable sizes of the telescope assemble are found by optimization methods and modal analysis, which will raise the resonant frequency by 4.21 %. As a result, the telescope assemble is less likely to resonate. Besides, the dynamic response module in ANSYS is utilized to analyze the modal type, harmonic vibration response and random vibration response of the telescope assemble. By the calculation of ANSYS, finite dement analysis (FEA) method proves that the performance of the telescope assemble is mildly enhanced by means of optimum design.展开更多
This paper uses finite element method to obtain the three-dimensional temperature field of laser-induced transient thermal grating (TTG) for two-layered structure of diamond film on ZnSe substrate. The numerical res...This paper uses finite element method to obtain the three-dimensional temperature field of laser-induced transient thermal grating (TTG) for two-layered structure of diamond film on ZnSe substrate. The numerical results indicate that unique two-times heating process is gradually experienced in the area between two adjacent grating stripes. However, there is a little change for the temperature field along the depth direction for the diamond film due to its great thermal conductivity. It further finds that the thickness of the diamond film has a significant influence on the temperature field in diamond/ZnSe system. The results are useful for the application of laser-induced TTG technique in film/substrate system.展开更多
In this paper,the spline finite element method is developed to investigate free vibration problems of beams.The cubic B-spline functions are used to construct the displacement field.The assembly of elements and the in...In this paper,the spline finite element method is developed to investigate free vibration problems of beams.The cubic B-spline functions are used to construct the displacement field.The assembly of elements and the introduction of boundary conditions follow the standard finite element procedure.The results under various boundary conditions are compared with those obtained by the exact method and the finite difference method.It shows that the results are in excellent agreement with the analytical results and much more accurate than the results obtained by the finite difference method,especially for higher order modes.展开更多
Wenchuan earthquake damage survey displayed the major structures of buildings suffered only small damages,but it was common that infill walls suffered heavy damages or even collapse. To study the failure forms and col...Wenchuan earthquake damage survey displayed the major structures of buildings suffered only small damages,but it was common that infill walls suffered heavy damages or even collapse. To study the failure forms and collapse mechanism of infill walls in an earthquake,the influence of opening or length-to-height ratio on shake-resisting capability of filling walls was analyzed,and measures to improve the anti-collapse ability of infill walls were put forwaed. The numerical simulations on collapse process in earthquake were carried out by using ABAQUS software. We used 5 single story and single span models. It is revealed that the rigidity and compressive capacity of infill walls are reduced because of the infill walls with holes and the increases of length-to-height ratios. Adding constructional columns and horizontal beams can ensure structural integrity and improve the anti-collapse ability of the wall.展开更多
基金supported by the Natural Science Foundation of Shandong Province(ZR2021MA019)the National Natural Science Foundation of China(11871312)。
文摘In this paper,a composite numerical scheme is proposed to solve the threedimensional Darcy-Forchheimer miscible displacement problem with positive semi-definite assumptions.A mixed finite element is used for the fow equation.The velocity and pressure are computed simultaneously.The accuracy of velocity is improved one order.The concentration equation is solved by using mixed finite element,multi-step difference and upwind approximation.A multi-step method is used to approximate time derivative for improving the accuracy.The upwind approximation and an expanded mixed finite element are adopted to solve the convection and diffusion,respectively.The composite method could compute the diffusion flux and its gradient.It possibly becomes an eficient tool for solving convection-dominated diffusion problems.Firstly,the conservation of mass holds.Secondly,the multi-step method has high accuracy.Thirdly,the upwind approximation could avoid numerical dispersion.Using numerical analysis of a priori estimates and special techniques of differential equations,we give an error estimates for a positive definite problem.Numerical experiments illustrate its computational efficiency and feasibility of application.
文摘In order to analyze the electrostatic field concerned with electrostatic proximity fuze problem using the available finite analysis software package, the technology to model the problem with a scale reduction object and boundary was presented. The boundary is determined by the maximum distance the sensor can detect. The object model is obtained by multiplying the terms in Poisson's equation with a scale reduction factor and the real value can be reconstructed with the same reverse process after software calculation. Using the finite element analysis program, the simulation value is close to the theoretical value with a little error. The boundary determination and scale reduction method is suitable to modeling the irregular electrostatic field around air targets, such as airplane, missile and so on, which is based on commonly used personal computer (PC). The technology reduces the calculation and storage cost greatly.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 61273164 and 61034005)the National High Technology Research and Development Program of China (Grant No. 2012AA040104)the Fundamental Research Funds for the Central Universities, China (Grant No. N100104102)
文摘With the increase of pipelines, corrosion leakage accidents happen frequently. Therefore, nondestructive testing technology is important for ensuring the safe operation of the pipelines and energy mining. In this paper, the structure and principle of magnetic flux leakage (MFL) in-line inspection system is introduced first. Besides, a mathematic model of the system according to the ampere circuit rule, flux continuity theorem, and column coordinate transform is built, and the magnetic flux density in every point of space is calculated based on the theory of finite element analysis. Then we analyze and design the disposition of measurement section probes and sensors combining both three-axis MFL in-line inspection and multi-sensor fusion technology. Its advantage is that the three-axis changes of magnetic flux leakage field are measured by the multi-probes at the same time, so we can determine various defects accurately. Finally, the theory of finite element analysis is used to build a finite element simulation model, and the relationship between defects and MFL inspection signals is studied. Simulation and experiment results verify that the method not only enhances the detection ability to different types of defects but also improves the precision and reliability of the inspection system.
文摘Objective: To treat humerus fracture with three dimensional pattern and finite element analysis, providing mechanical basis for treating humerus fracture. Methods: Humerus pattern was established based on the CT images, and calculation was done by ANSYS5. 6 software. Three dimensional ten-node tetrahedron unit was selected and were divided into 2 729 nodes, 49 041 units. Distribution and amount of axial compression of humerus were analyzed when clip angle was 30°, 45°, 90° between fracture face and axial line with fixed X, Y, Z directions. Results: The distribution of stress was greatly different between fracture face and non fracture face. Stress in fracture part was fairly concentrated with incomplete symmetric distribution around the center of fracture face; Greater stress distributed in the regions 10 mm from fracture face, which was 2-3 times that of other stress regions. Conclusion: Required load must be estimated under various conditions as to select the suitable internal fixation implants during the treatment of humerus fracture, which can provide helpful stress environment for fracture healing.
基金Sponsored by the Ministerial Level Foundation(40402020105)
文摘A contact bolt model is proposed as a new modeling technique to investigate the complex structure with bolted joints for modal analysis and compared with the coupled bolt model, and the test results are given. Among these models, the coupled bolt model provides the best accurate responses compared with the experimental results. The contact bolt model shows the best effectiveness and usefulness in view of operational time. The bolt models proposed in this study are adopted for a dynamic characteristic analysis of a large diesel engine consisting of several parts which are connected by many bolts. The dynamic behavior of the entire engine structure was investigated by experiment. The coupled bolt model and the contact bolt model were applied to model the assembly of engine with high preload. The experimental results are in good agreement with the finite element method (FEM) results. Compared with the other models, the contact bolt model presented in this paper is more effective and useful in view of operational time and experience of analysts.
文摘In this paper, an investigation into the propagation of far field explosion waves in water and their effects on nearby structures are carried out. For the far field structure, the motion of the fluid surrounding the structure may be assumed small, allowing linearization of the governing fluid equations. A complete analysis of the problem must involve simultaneous solution of the dynamic response of the structure and the propagation of explosion wave in the surrounding fluid. In this study, a dynamic adaptive finite element procedure is proposed. Its application to the solution of a 2D fluid-structure interaction is investigated in the time domain. The research includes:a) calculation of the far-field scatter wave due to underwater explosion including solution of the time-depended acoustic wave equation, b) fluid-structure interaction analysis using coupled Euler-Lagrangian approach, and c) adaptive finite element procedures employing error estimates, and re-meshing. The temporal mesh adaptation is achieved by local regeneration of the grid using a time-dependent error indicator based on curvature of pressure function. As a result, the overall response is better predicted by a moving mesh than an equivalent uniform mesh. In addition, the cost of computation for large problems is reduced while the accuracy is improved.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.51538009 and 51605334)the Natural Science Foundation of Shanghai Municipality,China(Grant No.08002360285)
文摘A new type of soft actuator material-ionic liquid gel (ILG), which consists of HEMA, BMIMBF4, and TiO2, can be transformed into gel state under the irradiation of ultraviolet (UV) light. In this paper, Mooney-Rivlin hyperelastic model of finite element method is proposed for the first time to study the properties of the ILG. It has been proved that the content of TiO2 has a great influence on the properties of the gel, and Young's modulus of the gel increases with the increase of its content, despite of reduced tensile deformation. The results in this work show that when the TiO2 content is 1.0 wt%, a large tensile deformation and a strong Young's modulus can be obtained to be 325% and 7.8 kPa, respectively. The material parameters of ILG with TiO2 content values of 0.2 wt%, 0.5 wt%, 1.0 wt%, and 1.5 wt% are obtained, respectively, through uniaxial tensile tests, including C10, C01, C20, C11, C02, C30, C21, C12, and C03 elements. In this paper, the large-scaled general finite element software ANSYS is used to simulate and analyze the ILG, which is based on SOLID186 element and nonlinear hyperelastic Mooney-Rivlin model. The finite element simulation analysis based stress-strain curves are almost consistent with the experimental stress-strain curves, and hence the finite element analysis of ILG is feasible and credible. This work presents a new direction for studying the performance of soft actuator for the ILG, and also contributes to the design of soft robot actuator.
文摘Natural fiber composites have been proved to have the ability to replace the synthetic fiber composites in many structural applications. Unprecedented growth in the field of computational techniques has opened the doors of analysis and simulation of composite materials under various environment.Modelling and simulation using various available softwares saves a lot of time and resources. In the present work, an attempt has been made to analyze the tensile behavior of jute fiber reinforced epoxy based polymer composite materials using the student version of commercially available finite element code Siemens PLM NX 10.0. In most of the structural applications, materials are required to have enough stiffness to resist the shape deformation under normal loading conditions. Therefore, emphasis is given to the load-deformation behavior of the developed composites. A 3-dimensional model of the test specimen was developed using ply-stacking method and the strain-stress values were verified by the available literature. The model showed a good agreement between the experimental and software results. Effect of ply angle, fiber percentage, fiber type, number of layers and weft fiber angle on the stiffness of laminate have been studied.
文摘Objective: To study the memory biomechanical character of anatomic distal radius Nitinol memory connector (DRMC) in treating distal radius fracture. Methods: Establishing three dimensional model and finite element analysis, we calculated the stress in and around the fracture faces when distal radius fracture was fixated with DRMC. Results: Axial holding stress produced by holding part of DRMC on distal radius was 14.66 MPa. The maximum stress of holding part was 40-70 MPa, the minimum stress was 3-7 MPa,and the stress of compression part was 20-40 MPa. Conclusion: The distribution of stress produced by DRMC around the fracture line is reasonable, and axial holding stress can help stabilize fracture during earlier period. The existence of longitudal compression and memory effect can transfer fixated disused section into developed section and enhance fracture healing.
基金Project 20002070005126 supported by the China Geological Survey
文摘The hydro-hammer sampler is a new type of sampler compared with traditional ones. An important part of this new offshore sampler is that the structure of the core cutter has a significant effect on penetration and core recovery. In our experiments, a commercial finite element code with a capability of simulating large-strain frictional contact between two or more solid bodies is used to simulate the core cutter-soil interaction. The effects of the cutting edge shape, the diameter and the edge angle on penetration are analyzed by non-liner transient dynamic analysis using a finite element method (FEM). Simulation results show that the cutter shape clearly has an effect on the penetration and core recovery. In addition, the penetration of the sampler increases with an increase in the inside diameter of the cutter, but decreases with an increase in the cutting angle. Based on these analyses, an optimum structure of the core cutter is designed and tested in the north margin of the Dalian gulf. Experiment results show that the penetration rate is about 16.5 m/h in silty clay and 15.4 m/h in cohesive clay, while the recovery is 68% and 83.3% resoectively.
基金Supported by the Research and Implementation of Sea Trial Technology(Grant No.2016YFC03000704).
文摘To control the vibration level of ships under construction,MSC Software’s Patran&Nastran modeling solutions can be used to establish a detailed finite element model of a new manned submersible support mother ship based on a line drawing,including the deck layout,bulkhead section,and stiffener distribution.After a comprehensive analysis of the ship simulation conditions,boundaries,and excitation forces of the main operating equipment,modal analysis and calculation of the ship vibration can be conducted.In this study,we calculated and analyzed the vibration response of key points in the stern area of the ship’s main deck and the submersible warehouse area under design loading working conditions.We then analyzed the vibration response of typical decks(including the compass deck,steering deck,captain’s deck,forecastle deck,and main deck)under the main excitation forces and moments(such as the full swing pod and generator sets).The analysis results showed that under DESIDEP working conditions,the vibration of each deck and key areas of the support mother ship could meet the vibration code requirements of the ship’s preliminary design(using the pod excitation and generator sets).Similarly,the vibration response of a scientific research ship under other loading conditions also met the requirements of the code and provided data support for a comprehensive understanding of the ship’s vibration and noise levels.Using actual vibration measurements,the accuracy of the vibration level simulations using finite element modeling was verified,the vibration of each area of the ship comfortably meeting the requirements of the China Classification Society.
文摘The uniform design method was adopted and the twenty-four groups of different geometric and physical pa-rameters were chosen. The finite element model was built. Comparisons between the simulation results and the test re-sults prove that the simulation results are correct. The distribution of the temperature field of the chimney foundationwas analyzed. The multivariate linear regression of the hightest tomperature was performed on the inner wall of thechimney foundation by the numerical calculated results. The fitting property of the highest temperature with six influ-ence factors was obtained. A simple method for the calculation of the temperature field of the chimney foundation wasprovided.
文摘Objective:To explore the mechanical behavior of acetabulum loaded by static stress and provide the mechanical basis for clinical analysis and judgement on acetabular mechanical distribution and effect of static stress.Methods:By means of computer simulation, acetabular three dimensional model was input into three dimensional finite element analysis software ANSYS7.0. The acetabular mechanical behavior was calculated and the main stress value, stress distribution and acetabular unit displacement in the direction of main stress were analyzed when anterior wall of acetabulum and acetabular crest were loaded by 1 000 N static stress. Results:When acetabular anterior wall loaded by X direction and Z direction composition force, the stress passed along 4 directions: (1)from acetabular anterior wall to pubic symphysis along superior branch of pubis firstly, (2)from acetabular anterior wall to cacroiliac joint along pelvic ring,(3)in the acetabulum,(4)from the suffered point to ischium. When acetabular crest loaded by X direction and Y direction composition force, the stress transmitted to 4 directions: (1)from acetabular crest to ilium firstly, (2)from suffered point to cacroiliac joint along pelvic ring,(3) in the acetabulum ,(4)along the pubic branch,but no stress transmitted to the ischium branch.Conclusion:Analyzing the stress distribution of acetabulum and units displacement when static stress loaded can provide internal fixation point for acetabular fracture treatment and help understand the stress distribution of acetabulum.
基金Funded by the Natural Science Foundation of China (No. 50675232)the Natural Science Foundation of CQ CSTC (2006BB3008)
文摘A dynamic finite element method combined with finite element mixed formula for contact problem is used to analyze the dynamic characteristics of gear system. Considering the stiffness excitation, error excitation and meshing shock excitation, the dynamic finite element model is established for the entire gear system which includes gears, shafts, bearings and gearbox housing. By the software of I-DEAS, the natural frequency, normal mode, dynamic time-domain response, frequency-domain response and one-third octave velocity grade structure borne noise of gear system are studied by the method of theoretical modal analysis and dynamic response analysis. The maximum values of vibration and structure borne noise are occurred at the mesh frequency of output grade gearing.
文摘The finite element analysis of the fretting behavior between a cylinder block and a main bearing cap is presented. The stresses, relative fretting slip, frettin g friction work parameter W and crack initiation location parameter Gon the fretting contact surface of the cylinder block are obtained and analyzed. It shows that the fretting fatigue problem of the cylinder block can be quantitat ively explained by WorG. The effects of pretightening force, friction factor and material combination of the cylinder block and the main bearing cap are studied. The computational results indicate that the fretting fatigue of the cylinder block can be allayed by increasing the elastic modulus of the cylinder block, but not by changing the other two factors.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11504051,51202031,61574037,and 11404058)the Natural Science Foundation of Fujian Province,China(Grant Nos.2017J06014,2015J01008,and 2014J01175)+1 种基金Fujian Provincial Program for Distinguished Young Scientists in University(Grant No.J1-1166)Fujian Provincial Key Project of Natural Science Foundation for Young Scientists in University(Grant No.JZ160428)
文摘In recent years,actuators based on carbon nanotube(CNT) or graphene demonstrate great potential applications in the fields of artificial muscles,smart switches,robotics,and so on.The electrothermal and photothermal bending actuators based on CNT/graphene and polymer composites show large bending actuations,which are superior to traditional thermaldriven actuators.However,the influence of material parameters(thickness,temperature change,etc.) on the actuation performance needs to be further studied,because it is a critical point to the design and fabrication of high-performance actuators.In this work,finite element analysis(EEA) is employed to simulate the actuation performance of CNT/polymer actuator,which has a bilayer structure.The main focus of this work is to design and to optimize material parameters by using computational method.FEA simulation results show that each layer thickness of actuator has an important influence on the actuation deformation.A maximum curvature of 2.7 cm^(-1) is obtained by simulation,which is much larger than most of the actuator curvature reported in previous experiments.What is more,larger temperature change and larger difference of coefficient of thermal expansion(CTE) between two layers will result in larger bending actuation.This study is expected to provide valuable theoretical reference for the design and realization of CNT-based thermal actuator with ultra-large actuation performance.
基金the Ministerial Level Advanced Rearch Foundation (304030401)
文摘To improve the performance of the 2 m telescope, the optimum design is applied to the telescope assemble. Referring to the telescope assemble with the dimetric truss, a group of reasonable sizes of the telescope assemble are found by optimization methods and modal analysis, which will raise the resonant frequency by 4.21 %. As a result, the telescope assemble is less likely to resonate. Besides, the dynamic response module in ANSYS is utilized to analyze the modal type, harmonic vibration response and random vibration response of the telescope assemble. By the calculation of ANSYS, finite dement analysis (FEA) method proves that the performance of the telescope assemble is mildly enhanced by means of optimum design.
基金Project supported by the National Natural Science Foundation of China (Grant Nos 10374041 and 10574071)
文摘This paper uses finite element method to obtain the three-dimensional temperature field of laser-induced transient thermal grating (TTG) for two-layered structure of diamond film on ZnSe substrate. The numerical results indicate that unique two-times heating process is gradually experienced in the area between two adjacent grating stripes. However, there is a little change for the temperature field along the depth direction for the diamond film due to its great thermal conductivity. It further finds that the thickness of the diamond film has a significant influence on the temperature field in diamond/ZnSe system. The results are useful for the application of laser-induced TTG technique in film/substrate system.
文摘In this paper,the spline finite element method is developed to investigate free vibration problems of beams.The cubic B-spline functions are used to construct the displacement field.The assembly of elements and the introduction of boundary conditions follow the standard finite element procedure.The results under various boundary conditions are compared with those obtained by the exact method and the finite difference method.It shows that the results are in excellent agreement with the analytical results and much more accurate than the results obtained by the finite difference method,especially for higher order modes.
基金Funded by research programs in Jiangsu(JGJH2008-22)
文摘Wenchuan earthquake damage survey displayed the major structures of buildings suffered only small damages,but it was common that infill walls suffered heavy damages or even collapse. To study the failure forms and collapse mechanism of infill walls in an earthquake,the influence of opening or length-to-height ratio on shake-resisting capability of filling walls was analyzed,and measures to improve the anti-collapse ability of infill walls were put forwaed. The numerical simulations on collapse process in earthquake were carried out by using ABAQUS software. We used 5 single story and single span models. It is revealed that the rigidity and compressive capacity of infill walls are reduced because of the infill walls with holes and the increases of length-to-height ratios. Adding constructional columns and horizontal beams can ensure structural integrity and improve the anti-collapse ability of the wall.