期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Evaluation method of cracking resistance of lightweight aggregate concrete 被引量:8
1
作者 季韬 张彬彬 +1 位作者 陈永波 庄一舟 《Journal of Central South University》 SCIE EI CAS 2014年第4期1607-1615,共9页
The cracking behavior of lightweight aggregate concrete(LWAC) was investigated by mechanical analysis, SEM and cracking-resistant test where a shrinkage-restrained ring with a clapboard was used. The relationship betw... The cracking behavior of lightweight aggregate concrete(LWAC) was investigated by mechanical analysis, SEM and cracking-resistant test where a shrinkage-restrained ring with a clapboard was used. The relationship between the ceramsite type and the cracking resistance of LWAC was built up and compared with that of normal-weight coarse aggregate concrete(NWAC). A new method was proposed to evaluate the cracking resistance of concrete, where the concepts of cracking coefficient ζt(t) and the evaluation index Acr(t) were proposed, and the development of micro-cracks and damage accumulation were recognized. For the concrete with an ascending cracking coefficient curve, the larger Acr(t) is, the lower cracking resistance of concrete is. For the concrete with a descending cracking coefficient curve, the larger Acr(t) is, the stronger the cracking resistance of concrete is. The evaluation results show that in the case of that all the three types of coarse aggregates in concrete are pre-soaked for 24 h, NWAC has the lowest cracking resistance, followed by the LWAC with lower water absorption capacity ceramsite and the LWAC with higher water absorption capacity ceramsite has the strongest cracking resistance. The proposed method has obvious advantages over the cracking age method, because it can evaluate the cracking behavior of concrete even if the concrete has not an observable crack. 展开更多
关键词 ceramsite type cracking resistance lightweight aggregate concrete evaluation index evaluation method
在线阅读 下载PDF
Fuzzy-AHP-Based Comprehensive Evaluation on Facility Management System of High-Rise Office Buildings 被引量:1
2
作者 张培红 WANG Kan +1 位作者 WAN Huanhuan MA Zhongjiao 《沈阳建筑大学学报(自然科学版)》 CAS 北大核心 2011年第2期324-330,共7页
The present building facility management status in China resulted in many problems such as high energy consumption,failure of automation control,services failure and poor indoor air quality.Based on questionnaires and... The present building facility management status in China resulted in many problems such as high energy consumption,failure of automation control,services failure and poor indoor air quality.Based on questionnaires and interviews to professional engineers and building users,a comprehensive evaluation index system was established on facility management of high-rise office buildings.A Fuzzy AHP based upon hierarchy criteria system was established.A Fuzzy AHP Evaluation Model on Facility Management System was set up;α-cut analysis was introduced and incorporated with expert knowledge together,which made up the optimism indexλ.The fuzzy optimum crisp weight of each criterion was resulted from data-mining.Case investigations were processed in high-rise office buildings in Shenyang.The results illustrated that indoor air quality,thermal comfort and life cycle cost were the most important indexes in the evaluation of Facility Management System of high rise office buildings.Residents in high-rise buildings in Shenyang pay less attention to maintenance management and environment protection.By comparison with the analysis result of Export Choice,Fuzzy AHP-based evaluation model could act as a scientific reference for the establishment of governmental standards in facility management area in building. 展开更多
关键词 building facility management evaluation index Fuzzy AHP indoor air quality thermal comfort
在线阅读 下载PDF
Recommended Concentration Limits of Typical Indoor Air Contaminants 被引量:1
3
作者 LV Chao JIANG Yun-tao ZHAO Jia-ning 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期60-65,共6页
From the view of both objective and subjective factors,the indoor air quality(IAQ)evaluation was considered.Carbon dioxide(CO_(2))and formaldehyde(HCHO)were selected as the typical contaminants of indoor air,and the e... From the view of both objective and subjective factors,the indoor air quality(IAQ)evaluation was considered.Carbon dioxide(CO_(2))and formaldehyde(HCHO)were selected as the typical contaminants of indoor air,and the evaluation method of logarithmic index was adopted as the evaluation means of IAQ.Then the recommended limits(RL)of typical contaminants CO_(2)and HCHO were given through analysis and calculation.The limits of CO_(2)and HCHO in Indoor Air Quality Standard of China or other existing standards probably correspond to the level of PD=25(%).The result shows that the existing standards fail to meet the requirement of the definition of"acceptable indoor air quality",that is to say,less than 20%of the people express dissatisfaction.When PD=20%,RL of CO_(2)and HCHO are 728×10-6 and 0.068×10-6 respectively,which are stricter than the limits in the existing standards.The method proposed in this paper is applicable to 13.1%≤PD≤86.7%. 展开更多
关键词 indoor air quality(IAQ) typical contaminants recommended limits(RL) evaluation method of logarithmic index percentage of dissatisfaction(PD)
在线阅读 下载PDF