期刊文献+
共找到62篇文章
< 1 2 4 >
每页显示 20 50 100
Association between echocardiography utilization and prognosis in patients with cardiac arrest
1
作者 Nan Zhang Qingting Lin Huadong Zhu 《World Journal of Emergency Medicine》 2025年第1期63-66,共4页
Despite efforts to develop treatment technology for cardiac arrest (CA),CA incidence and mortality rates are still high.^([1,2])A recent study of CA patients in emergency departments revealed that the incidence of CA ... Despite efforts to develop treatment technology for cardiac arrest (CA),CA incidence and mortality rates are still high.^([1,2])A recent study of CA patients in emergency departments revealed that the incidence of CA is increasing annually,and the in-hospital survival rate of CA patients is only approximately 28.7%.^([3])Echocardiography has been widely used as an important monitoring tool in critical care and helps to identify the cause of shock,monitor hemodynamics,and guide fluid therapy utilization.^([4])One study reported that approximately one-third of patients underwent formal echocardiography during hospitalization in the intensive care unit (ICU). 展开更多
关键词 PATIENTS echocardiography CARDIAC
在线阅读 下载PDF
BILL Strategy:Points to Consider During the Performance and Interpretation of Critical Care Echocardiography
2
作者 Hong-Min Zhang Hui Lian Xiao-Ting Wang 《Chinese Medical Sciences Journal》 CAS CSCD 2024年第3期234-241,共8页
The growing utilization of critical care echocardiography(CCE) by clinicians necessitates a meticulous review of clinical conditions in critically ill patients, both before and during the examination. The reviewing pr... The growing utilization of critical care echocardiography(CCE) by clinicians necessitates a meticulous review of clinical conditions in critically ill patients, both before and during the examination. The reviewing process of clinical conditions minimizes the risk of overlooking or misinterpreting crucial findings. This article proposes a comprehensive strategy, namely BILL strategy, to integrate into the CCE protocol, where "B" represents baseline respiratory and hemodynamic support, "I" signifies information gleaned from invasive monitoring, including central venous pressure and thermodilution-derived cardiac output, the first "L" denotes laboratory results such as central venous oxygen saturation, troponin, and brain natriuretic peptide, and the second "L" refers to lung ultrasound data. Combining the BILL strategy with CCE can enhance comprehensive understanding of critical conditions, potentially leading to improved diagnostic accuracy and patient outcomes. 展开更多
关键词 echocardiography critical care clinical condition
在线阅读 下载PDF
CLINICAL ASSESSMENT OF BIPLANAR TRANSESOPHAGEAL ECHOCARDIOGRAPHY──A REPORT OF 125 CASES
3
作者 王国干 孟宪强 +4 位作者 樊朝美 张辉 刘醒 刘汉英 蔡如升 《Chinese Medical Sciences Journal》 CAS CSCD 1994年第3期190-193,共4页
One hundred and twenty-five patients with cardiovascular disease were examined by biplanar transesophageal echocardiography (BTEE), including 67 with rheumatic heart disease (7 monitored during operation), 22 with ao... One hundred and twenty-five patients with cardiovascular disease were examined by biplanar transesophageal echocardiography (BTEE), including 67 with rheumatic heart disease (7 monitored during operation), 22 with aortic diseases, 20 with congenital heart diseases. and 16 with other kinds of heart disease. The results showed that BTEE was not influenced by corpulent and pulmonary emphysema and was better than transthoracic echocardiography at imaging the interatrial septum, left atrium and left atrial appendage, thoracic aorta, and mitral artificial valve and at intraoperative monitoring. BTEE was also better than single-plane transesophageal echocardiography,because BTEE could be used to observe the heart and thoracic aorta in transverse and longitudinal planes, thus enlarging the transmission 'window' as well as allowing the entire lesion to be imaged.This study suggests that BTEE will have good prospects in clinical application. 展开更多
关键词 transesophageal echocardiography echocardiography
在线阅读 下载PDF
CLINICAL APPLICATION OF OMNIPLANE TRANSESOPHAGEAL ECHOCARDIOGRAPHY
4
作者 王国干 刘汉英 +1 位作者 孟宪强 程克正 《Chinese Medical Sciences Journal》 CAS CSCD 1996年第3期177-179,共3页
One hundred and twenty-four patients with heart disease(75 cases of rheumatic heart disease,26 cases of congenital heart disease,13 cases of aortic disease and 10 cases of other disease)were examined by Omniplane tran... One hundred and twenty-four patients with heart disease(75 cases of rheumatic heart disease,26 cases of congenital heart disease,13 cases of aortic disease and 10 cases of other disease)were examined by Omniplane transesophageal echocardiography(TEE).The result showed that Omniplane TEE transducer can be rotated from 0°to 180°in probe and had the advantages of broader scope,obtaining more information,less stimulation to esophagus and easy to manipulate.It suggests that Omniplane TEE is a efficient technique in clinical diagnosis and can be extensively used in the future. 展开更多
关键词 transesophageal echocardiography echocardiography
在线阅读 下载PDF
Speckle-tracking echocardiography for detecting myocardial dysfunction in sepsis and septic shock patients:A single emergency department study 被引量:8
5
作者 Xuan Fu Xue Lin +4 位作者 Samuel Seery Li-na Zhao Hua-dong Zhu Jun Xu Xue-zhong Yu 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2022年第3期175-181,共7页
BACKGROUND:Septic cardiomyopathy(SCM)occurs in the early stage of sepsis and septic shock,which has implications for treatment strategies and prognosis.Additionally,myocardial involvement in the early stages of sepsis... BACKGROUND:Septic cardiomyopathy(SCM)occurs in the early stage of sepsis and septic shock,which has implications for treatment strategies and prognosis.Additionally,myocardial involvement in the early stages of sepsis is difficult to identify.Here,we assess subclinical myocardial function using laboratory tests and speckle-tracking echocardiography(STE).METHODS:Emergency department patients diagnosed with sepsis or septic shock were included for analysis.Those with other causes of acute or pre-existing cardiac dysfunction were excluded.Transthoracic echocardiography(TTE),including conventional echocardiography and STE,were performed for all patients three hours after initial resuscitation.Samples for laboratory tests were taken around the time of TTE.RESULTS:Left ventricular functions of 60 patients were analyzed,including 21 septic shock patients and 39 sepsis patients.There was no significant difference in global longitudinal strain(GLS),global circumferential strain(GCS),or global radical strain(GRS)between patients with sepsis and septic shock(all with P>0.05).However,GLS and GCS were significantly less negative in patients with abnormal troponin levels or in patients with abnormal left ventricular ejection fraction(LVEF)values(all with P<0.05).There were also moderate correlations between GLS and levels of cTnI(r=0.40,P=0.002)or N-terminal pro-B-type natriuretic peptide(NT-proBNP)(r=0.44,P=0.001)in sepsis and septic shock patients.CONCLUSION:Myocardial dysfunction,e.g.,lower LVEF or less negative GLS in patients with sepsis or septic shock,is more affected by myocardial injury.GLS could be incorporated into mainstream clinical practice as a supplementary LVEF parameter,especially for those with elevated troponin levels. 展开更多
关键词 SEPSIS Septic shock Speckle-tracking echocardiography Global longitudinal strain Global circumferential strain
在线阅读 下载PDF
Assessment of Left Atrial Function by Full Volume Real-time Three-dimensional Echocardiography and Left Atrial Tracking in Essential Hypertension Patients with Different Patterns of Left Ventricular Geometric Models 被引量:9
6
作者 Yang Wang Lin Gao +1 位作者 Jian-bai Li Chao Yu 《Chinese Medical Sciences Journal》 CAS CSCD 2013年第3期152-158,共7页
Objective To evaluate left atrial function in essential hypertension patients with different patterns of left ventricular geometric models by real-time three-dimensional echocardiography (RT-3DE) and left atrial tra... Objective To evaluate left atrial function in essential hypertension patients with different patterns of left ventricular geometric models by real-time three-dimensional echocardiography (RT-3DE) and left atrial tracking (EAT). 展开更多
关键词 essential hypertension left atrial function three-dimensional echocardiography left atrial tracking
在线阅读 下载PDF
REAL-TIME THREE-DIMENSIONAL ECHOCARDIOGRAPHY FOR QUANTIFYING LEFT VENTRICULAR MASS 被引量:4
7
作者 Hong-wenFei Xin-fangWang +5 位作者 Ming-xingXie LeiZhuang Li-xinChen Run-qingHuang YingYang JingWang 《Chinese Medical Sciences Journal》 CAS CSCD 2004年第3期230-232,共3页
To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phanto... To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phantoms made of two rubber-bursas, ten excised canine hearts underwent RT3DE and two-dimensional echocardiography (2DE). In RT3DE "full volume" imaging, the myocardial volume was mea-sured using 2,4,8, and 16-plane method with the analysis software of RT3DE. Mass was then calculated by multiplying the resulting myocardial volume by specific density of myocardial tissue. In 2DE the masses were measured by area-length meth-od. The true LV wall phantom mass was measured by water displacement and the canine LVM was weighed by anatomy, which served as a reference standard. We compared RT3DE or 2DE with true mass. Results In LV wall phantoms, RT3DE correlated with true masses strongly (r = 0.813-0.994) and weakly correlated between 2DE and true masses (r = 0.628). In excised canine hearts, there is an excellent correlation between RT3DE and true masses (r = 0.764-0.991), while 2DE value showed a lesser correlation (r = 0.514). There are no difference between RT-3DE and true masses (P > 0.05) but different between 2DE and true masses (P < 0.05). In different planes, there was no difference between 8-plane and 16-plane (P > 0.05) but different between 8-plane and 2, 4-plane (P < 0.05). Conclusion RT3DE can accurately quantify LVM and provide a new tool to evaluate LV function. For LVM by RT3DE, 8-plane measurement method is the best choice for accuracy and convenience. 展开更多
关键词 real-time three-dimensional echocardiography left ventricular mass
在线阅读 下载PDF
The role of echocardiography and CT angiography in transcatheter aortic valve implantation patients 被引量:4
8
作者 Emmanouil Chourdakis Ioanna Koniari +6 位作者 Nicholas G Kourlis Dimitrios Velissaris Nikolaos Koutsogiannis Grigorios Tsigkas Karl Eugen Hauptmann Bruno Sontag George Hahalis 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2018年第1期86-94,共9页
The transcatheter aortic valve implantation (TAVI) consist an altemative treatment in patients with severe aortic stenosis. Multimodality imaging using transthoracic echocardiography (TTE) or transesophageal echoc... The transcatheter aortic valve implantation (TAVI) consist an altemative treatment in patients with severe aortic stenosis. Multimodality imaging using transthoracic echocardiography (TTE) or transesophageal echocardiography (TOE) and multislice CT (MSCT) constitute cornerstone techniques for the pre-operative management, peri-procedural guidance, follow up and recognition of possible transcatheter valve related complications. CT angiography is much more accurate regarding the total definition of aortic annulus diameter and circumferential area. Two-dimensional (2D) echocardiography, underestimates the aortic valve annulus diameter compared to 3D imaging techniques (MSCT, MRI and 3D TOE). Three-dimensional TOE imaging provides measurements of the aortic valve annulus similar to those delivered by MSCT. The pre-procedural MSCT constitutes the gold standard modality minimizing the presence of paravalvular aortic regurgitation, one of the most frequent complications. TOE/TTE and MSCT performance could predict the possibility of pacemaker implantation post-procedural. The presence of a new transient or persisting MR can be assessed well by TOE. Both TTE and TOE, consist initially the basic examination for post TAVI evaluation. In case of transcatheter heart valve failure, the MSCT could be used as additional imaging technique. 展开更多
关键词 Multi-slice computer tomography Transcatheter aortic valve implantation Transthoracic echocardiography
在线阅读 下载PDF
Assessment and impact of diastolic function by echocardiography in elderly patients 被引量:3
9
作者 Clementina Dugo Marzia Rigolli +1 位作者 Andrea Rossi Gillian A Whalley 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2016年第3期252-260,共9页
Doppler echocardiography is the gold standard for assessment of diastolic dysfunction, which is increasingly recognised as a cause of heart failure, especially in the elderly. Using a combination of Doppler echocardio... Doppler echocardiography is the gold standard for assessment of diastolic dysfunction, which is increasingly recognised as a cause of heart failure, especially in the elderly. Using a combination of Doppler echocardiography techniques, it is possible to identify grades of dia- stolic dysftmction, estimate left ventricular filling pressures and establish the chronicity of diastolic dysfunction. These physiologi- cally-derived measures have been widely validated against invasive measurements of left heart pressures and have been shown to be prog- nostically valuable in a wide range of clinical settings. This review explores the mechanisms, and approaches to the assessment of diastolic dysfunction in the elderly. The challenge for clinicians is to identify pathophysiological changes from those associated with normal ageing. When used in combination, and taking age into account, Doppler echocardiographic parameters are helpful in the assessment of dyspnoea in older patients and provide prognostic insights. 展开更多
关键词 Diastolic dysfunction DOPPLER echocardiography
在线阅读 下载PDF
QUANTITATIVE ASSESSMENT OF MYOCARDIAL PERFUSION DEFECTS WITH REAL-TIME THREE-DIMENSIONAL MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY 被引量:2
10
作者 Lei Zhuang Ming-xing Xie +2 位作者 Wei-juan Wang Xiang-xin Yang Tao Liu 《Chinese Medical Sciences Journal》 CAS CSCD 2006年第3期135-139,共5页
Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed... Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed in 21 open-chest mongrel dogs undergoing acute ligation of the left anterior descending artery (LAD, n=14) or distal branch of the left circumflex artery (LCX, n=7). A perfluorocarbon microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with Philips Sonos-7500 ultrasound system. Evans blue dye was injected into the occluded coronary artery for subsequent anatomic identification of underperfused myocardium. In vitro anatomic measurement of myocardial mass after removal of the animal’s heart was regarded as the control. Blinded off-line calculation of left ventricular mass and perfusion defect mass from RT3DE images were performed using an interactive aided-manual tracing technique.Results Total left ventricular (LV) myocardial mass ranged from 38.9 to 78.5 (mean±SD: 60.0±10.1) g. The mass of perfusion defect ranged from 0 to 21.4 (mean±SD: 12.0±5.0) g or 0 to 27% of total LV mass (mean±SD: 19%±6%). The RT3DE estimation of total LV mass (mean±SD: 59.8±9.9 g) strongly correlated with the anatomic measurement (r=0.98; y=2.01+0.96x). The CE-RT3DE calculation of the mass of underperfused myocardium (mean±SD: 12.3±5.3 g) also strongly correlated with the anatomic measurement (r=0.96; y=-0.10+1.04x) and when expressed as percentage of total LV mass (r=0.95; y=-0.20+1.04x). Conclusions RT3DE with myocardial contrast opacification could accurately estimate underperfused myocardial mass in dogs of acute coronary occlusion and would play an important role in quantitative assessment of myocardial perfusion defects in patients with coronary artery disease. 展开更多
关键词 real-time three-dimensional echocardiography CONTRAST perfusion defects myocardial infarction
在线阅读 下载PDF
Role of real-time three-dimensional transesophageal echocardiography in mitral valve repair 被引量:1
11
作者 Cuizhen Pan~1 Xianhong Shu~1 Qiling Cao~2 Chunsheng Wang~1 Wenjun Ding~1 Haozhu Chen~1 1 Department of Echocardiography, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai 200032, China, 2 Rush University Medical Center, Chicago, USA 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2008年第3期137-141,共5页
Background and objective Pre-operative assessment of mitral valve (MV) anatomy is essential to surgical design in patients undergoing MV repair.Although 2-dimensional (2D) echocardiography provides precise information... Background and objective Pre-operative assessment of mitral valve (MV) anatomy is essential to surgical design in patients undergoing MV repair.Although 2-dimensional (2D) echocardiography provides precise information regarding MV anatomy,RT-3D TEE could increase the understanding of MV apparatus and individual scallop identification.We aimed to investigate the value of RT- 3DTEE in MV repair.Methods RT-3DTEE was performed in six patients with mitral valve prolapse (MVP) by using Philips 1E33 with X7-2t probe.Preoperative RT-3DTEE studies were compared with surgical findings in patients undergoing surgical mitral valve repair,and quantitative evaluation was performed by QLab 6.0 software before and after surgical mitral valve repair.Results RT- 3DTEE could display dynamic morphology of MV,the location of prolapse,and spatial relation to the surrounding tissue.It could provide surgical views of the valves and the valvular apparatus.These results were consistent with surgical findings.The quantitative evaluation before and after surgical MV repair indicated that anterolateral to posteromedial diameter of annulus,anterior to posterior diameter of annulus,perimeter of annulus,and area of annulus in projection plane were significantly smaller after operation compared with those before operation (P【0.05).The length of posterior leaflet,the area of anterior and posterior leaflet,the maximal prolapse height,the volume of leaflet prolapse and the length of coaptation in projection plane were significantly reduced after operation (P【0. 05).Conclusion RT-3DTEE is a unique new modality for rapid and accurate evaluation ofmitral valve prolapse and mitral valve repair. 展开更多
关键词 echocardiography REAL-TIME transeophageal MITRAL VALVE REPAIR
在线阅读 下载PDF
OMNIPLANE TRANSESOPHAGEAL ECHOCARDIOGRAPHY IMAGING PLANES EXPLORATION 被引量:1
12
作者 王国干 刘汉英 +1 位作者 程克正 孟宪强 《Chinese Medical Sciences Journal》 CAS CSCD 1996年第1期41-44,共4页
One hundred and twenty-four patients with heart disease were examined by omniplane TEE in order to systematically research every views of omniplane TEE, and further explore anatomy and image feature of each view. The ... One hundred and twenty-four patients with heart disease were examined by omniplane TEE in order to systematically research every views of omniplane TEE, and further explore anatomy and image feature of each view. The result showed that omniplane TEE transducer can be rotated in probe from 0°to 180°.obtain many views at various angles behind the heart and fully demonstrate the structure and pathology of the heart and great vessels. It was useful for clinical diagnosis because of getting more information about the heart and great vessels. As omniplane TEE probe was little rotated in esophagus, it lessened esophagus stimulation. Meanwhile, it was suitable for three-dimensional reconstruction of left ventriculum. 展开更多
关键词 transesophageal echocardiography: echocardiography
在线阅读 下载PDF
Assessment of left ventricular ejection fraction: comparison of two dimensional echocardiography, cardiac magnetic resonance imaging and 64-row multi-detector computed tomography
13
作者 Chee Khoon LIEW Rapaee ANNUAR +6 位作者 Tiong Kiam ONG Sze Piaw CHIN Tobias Seyfarth Yean Yip FONG Choon Kiat ANG Houng Bang LIEW Kui Hian SIM 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2006年第1期2-8,共7页
Objectives To compare left ventricular ejection fraction (LVEF) determined from 64-row multi-detector computed tomography (64-row MDCT) with those determined from two dimensional echocardiography (2D echo) and cardiac... Objectives To compare left ventricular ejection fraction (LVEF) determined from 64-row multi-detector computed tomography (64-row MDCT) with those determined from two dimensional echocardiography (2D echo) and cardiac magnetic resonance imaging (CMR). Methods Thirty-two patients with coronary artery disease underwent trans-thoracic 2D echo, CMR and contrast-enhanced 64-row MDCT for assessment of LVEF within 48 hours of each other. 64-row MDCT LVEF was derived using the Syngo Circulation software; CMR LVEF was by Area Length Ejection Fraction (ALEF) and Simpson method and 2D echo LVEF by Simpson method.Results The LVEF was 49.13 ± 15.91% by 2D echo, 50.72 ± 16.55% (ALEF method) and 47.65 ± 16.58%(Simpson method) by CMR and 50.00 ± 15.93% by 64-row MDCT. LVEF measurements by 64-row MDCT correlated well with LVEF measured with CMR using either the ALEF method (Pearson correlation r = 0.94, P <0.01) or Simpson method (r = 0.92, P<0.01). It also correlated well with LVEF measured using 2D echo (r = 0.80, P < 0.01). Conclusion LVEF measurements by 64-row MDCT correlated well with LVEF measured by CMR and 2D echo. The correlation between 64-row MDCT and CMR was better than the correlation between 2D echo with CMR. Standard data set from a 64-row MDCT coronary study can be reliably used to calculate the LVEF. 展开更多
关键词 EJECTION FRACTION echocardiography magnetic resonance imaging COMPUTED TOMOGRAPHY
在线阅读 下载PDF
Assessment of left atrial appendage function by transesophageal echocardiography in patients two weeks after acute coronary syndromes
14
作者 Grzegorz Piotrowski Zenon Gawor +1 位作者 Dariusz Timler Jozef Tazbir 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2005年第4期198-201,共4页
Background For many years in ischemic heart disease, ventricles rather than atria received attention so not much is known about left atrial function in left ventricular ischemia. Objective Our study aimed to evaluate ... Background For many years in ischemic heart disease, ventricles rather than atria received attention so not much is known about left atrial function in left ventricular ischemia. Objective Our study aimed to evaluate left atrial appendage (LAA) function by means of biplane transesophageal echocardiography in patients ten days after acute coronary syndromes (ACS). Methods The study was performed on 16 adult patients (65.9±9.9 years old) in whom transesophageal echocardiography was done 10 days after ACS. The following left atrial appendage (LAA) planimetric parameters were analyzed: LAA transversal dimension, LAA longitudinal dimension,LAA maximal area, and LAA minimal area. LAA ejection fraction was calculated and analyzed. The following LAA Doppler parameters were analyzed: the peak LAA emptying and the peak LAA filling velocities. The control group consisted of 14 patients (43±14.6 years old) without cardiovascular diseases. Results Both LAA longitudinal dimension and LAA transversal dimension were significantly higher in patients with ACS than in control patients. The same was observed for LAA maximal area. Also LAA ejection fraction was higher in patients with ACS . LAA minimal area did not differ in the patients in either group. LAA peak emptying flow (LAAE) and LAA peak filling flow (LAAF) were significantly higher in patients of the study group than of the control group. Conclusion Our study shows that two weeks after acute coronary syndrome LAA as a reservoir as well as a pump works at a higher level than it does in the control group. (J Geriatr Cardiol 2005; 2(4):198-201) 展开更多
关键词 LEFT ATRIAL appendage acute CORONARY SYNDROMES TRANSESOPHAGEAL echocardiography
在线阅读 下载PDF
Real-time Three-dimensional Echocardiography in Assessment of Left Ventricular and Right Ventricular Volumes
15
作者 YingYang Xin-fangWang Ming-xingXie JingWang 《Chinese Medical Sciences Journal》 CAS CSCD 2004年第3期236-236,共1页
关键词 ADULT echocardiography Three-Dimensional Heart Ventricles Humans Stroke Volume Ventricular Function Left Ventricular Function Right
在线阅读 下载PDF
Self-Appraisal of Clinical Competence in Echocardiography of Chinese Intensivists Post Basic Echocardiography Training
16
作者 Wei He Xue-Ying Zeng +3 位作者 Hong-Min Zhang Xiao-Ting Wang Yan-Gong Chao Critical Care Ultrasound Study Group 《Chinese Medical Sciences Journal》 CAS CSCD 2023年第2期125-129,共5页
Objectives To learn the echocardiography skills of intensivists after receiving a basic critical care echocardiography training course,and investigate factors that may influence their performance.Methods We completed ... Objectives To learn the echocardiography skills of intensivists after receiving a basic critical care echocardiography training course,and investigate factors that may influence their performance.Methods We completed a web-based questionnaire that assessed the skills in ultrasound scanning techniques of intensivists who took a training course on basic critical care echocardiography held in 2019 and 2020.MannWhitney test was used to analyze the factors which might affect their performance on image acquisition,recognizing clinical syndrome,and measuring the diameter of inferior vena cava,left ventricular ejection fraction and left ventricular outflow tract velocity-time integral.Results We enrolled 554 physicians from 412 intensive care units across China.Among them,185(33.4%)reported that they had 10%-30%chance of being misled by critical care echocardiography when making therapeutic decision,and 34(6.1%)reported that the chance was greater than 30%.Intensivists who performed echocardiography under the guidance of a mentor and finished ultrasound scanning more than 10 times per week reported significant higher scores in image acquisition,clinical syndrome recognition,and quantitative measurement of inferior vena cava diameter,left ventricular ejection fraction and left ventricular outflow tract velocity-time integral than those without mentor and performing echocardiography 10 times or less per week respectively(all P 0.05).Conclusion The skills in diagnostic medical echocardiography of Chinese intensivists after a basic echocardiographic training course remain low,and further quality assurance training program is clearly warranted. 展开更多
关键词 PHYSICIAN critical care echocardiography TRAINING
在线阅读 下载PDF
A cadaveric model for transesophageal echocardiography transducer placement training: A pilot study
17
作者 Ryan W.Horton Kian R.Niknam +3 位作者 Viveta Lobo Kathryn H.Pade Drew Jones Kenton L.Anderson 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2022年第1期18-22,共5页
BACKGROUND: Transesophageal echocardiography(TEE) is used in the emergency department to guide resuscitation during cardiac arrest. Insertion of a TEE transducer requires manual skill and experience, yet in some resid... BACKGROUND: Transesophageal echocardiography(TEE) is used in the emergency department to guide resuscitation during cardiac arrest. Insertion of a TEE transducer requires manual skill and experience, yet in some residency programs cardiac arrest is uncommon, so some physicians may lack the means to acquire the manual skills to perform TEE in clinical practice. For other infrequently performed procedural skills, simulation models are used. However, there is currently no model that adequately simulates TEE transducer insertion. The aim of this study is to evaluate the feasibility and efficacy of using a cadaveric model to teach TEE transducer placement among novice users.METHODS: A convenience sample of emergency medicine residents was enrolled during a procedure education session using cadavers as tissue models. A pre-session assessment was used to determine prior knowledge and confidence regarding TEE manipulation. Participants subsequently attended a didactic and hands-on education session on TEE placement. All participants practised placing the TEE transducer until they were able to pass a standardized assessment of technical skill(SATS). After the educational session, participants completed a post-session assessment. RESULTS: Twenty-five residents participated in the training session. Mean assessment of knowledge improved from 6.2/10 to 8.7/10(95% confidence interval [CI] of knowledge difference 1.6–3.2, P<0.001) and confidence improved from 1.6/5 to 3.1/5(95% CI of confidence difference 1.1–2.0, P<0.001). There was no relationship between training level and the delta in knowledge or confidence.CONCLUSIONS: In this pilot study, the use of a cadaveric model to teach TEE transducer placement methods among novice users is feasible and improves both TEE manipulation knowledge and confidence levels. 展开更多
关键词 Cardiopulmonary resuscitation echocardiography EDUCATION Simulation
在线阅读 下载PDF
Assessment of mitral valve reserve capacity before and after percutaneous balloon valvuloplasty with isoproterenol stress echocardiography
18
作者 刘品明 傅向阳 +2 位作者 吕俊豪 吴群 杨福庆 《Journal of Medical Colleges of PLA(China)》 CAS 2002年第3期196-201,共6页
Objective: To explore whether successful valvuloplasty increases mitral valve reserve capacity in patients with mitral stenosis. Methods: Thirty-eight patients with pure rheumatic mitral stenosis underwent isoproteren... Objective: To explore whether successful valvuloplasty increases mitral valve reserve capacity in patients with mitral stenosis. Methods: Thirty-eight patients with pure rheumatic mitral stenosis underwent isoproterenol stress echocardiography before and after successful percutaneous balloon valvuloplasty. The mitral valve area (by direct planimetry of two-dimensional echocardiography), mean transmitral pressure gradient (by continuous-wave Doppler echocardiography), and cardiac output (by M-mode echocardiography) were measured at rest and under isoproterenol infusion to achieve heart rate of different stages. Results:Between the measurements before and after valvuloplasty, significant differences were observed in the mitral valve area (0. 91±0. 28 vs 1. 87±0. 23 cm2, P<0. 01), mean transmitral pressure gradient (12. 5±6. 3 vs 3. 9±1. 9 mmHg, P<0. 01) and cardiac output (3. 93±1. 44 vs 4. 73±1. 01 L/min, P<0. 05) at rest. Before valvuloplasty, the mean transmitral pressure gradient increased significantly (P<0. 01) as heart rate increased, but there were no significant differences in the measurements of mitral valve area and cardiac output (both P>0. 05). In contrast, there was a significant increase after valvuloplasty in the mean transmitral pressure gradient (P<0. 01), but both mitral valve area and cardiac output further increased (both P< 0. 01) as heart rate increased. Moreover, valvuloplasty decreased the mean transmitral pressure gradient at peak heart rate from 23. 0±4. 5 to 7. 75±2. 30 mmHg (F<0. 01) under submaximal stress. Conclusion: Successful percutaneous balloon valvuloplasty soon causes a significant increase of mitral valve reserve capacity in patients with mitral stenosis, which is conspicuously manifested under condition of hemodynamic stress. Stress echocardiography provides a safe, feasible and non-invasive means of assessing the reserve capacity. 展开更多
关键词 mitral valve stenosis balloon dilation HEMODYNAMICS echocardiography ISOPROTERENOL
在线阅读 下载PDF
Echocardiography in centenarians: characteristics, utility and follow-up
19
作者 Jorge A Brenes-Salazar Jaime de la Fuente +4 位作者 Punnaiah Marella Hari Chaliki Christopher Scott Heidi M Connolly Roger L Click 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2018年第5期328-333,共6页
Background Echocardiography has been shown to be a valuable resource in the diagnosis of many cardiac conditions, and can be used in all age groups, from the fetus to the oldest old. In the context of an increasingly ... Background Echocardiography has been shown to be a valuable resource in the diagnosis of many cardiac conditions, and can be used in all age groups, from the fetus to the oldest old. In the context of an increasingly aging population, the impact and utility of echocar- diography in centenarians is largely unknown. This study is to determine whether echocardiography in centenarians aids in making clinical patient management decisions. Methods A retrospective review of echocardiograms from 1986 to 2014, at two affiliated tertiary centers, in individuals who were 100 years or older at the time of the examination. Patient and echocardiogram characteristics, management decisions based on echocardiography, and mortality were documented. Results 114 centenarians had echocardiograms, with ages ranging from 100 to 107 years (101 - 1.4 years). In 82 of the centenarians evaluated (72%), no changes in management occurred as a consequence of the echocardiogram. From all management changes directly related to the echocardiogram, 81% (n = 26) of these corresponded to medication adjustments; interventional or surgical procedures followed the echocardiogram only in 4% (n = 5) of the total number of centenarians. Echocardiogram-based changes in management were only significant in patients that were referred for congestive heart failure (P = 0.02). After the echocardiogram was performed, 1-month and 1-year mortality were 15% and 47%, respectively. The median survival after the echocardiogram was obtained was 13 months (range 0.03 to 145 months), with no difference if there was a change or no change in manage- ment (P = 0.21). Conclusions Among centenarians undergoing echocardiography, despite additional diagnostic information, echocardio- grams in centenarians influence management in a minority of cases, most commonly in the form of medication changes for treatment of heart failure. A significant proportion of centenarians are deceased within a year of undergoing echocardiographic assessment. These findings may question the overall utility of echocardiography in these late survivors. 展开更多
关键词 CENTENARIAN echocardiography GERIATRIC
在线阅读 下载PDF
Study on linage Acquisition of Transthoracic Echocardiography in Mechanically Ventilated ICU Patients
20
作者 Cui Wang Xiaodong Deng +2 位作者 Hongmin Zhang Dawei Liu Xiaoting Wang 《Chinese Medical Sciences Journal》 CAS CSCD 2020年第4期323-329,共7页
Objective This study aimed to determine which parameters in transthoracic echocardiography(TTE)are more likely to be affected when applied in a critical care setting with mechanical ventilation.Methods Ninety mechanic... Objective This study aimed to determine which parameters in transthoracic echocardiography(TTE)are more likely to be affected when applied in a critical care setting with mechanical ventilation.Methods Ninety mechanically ventilated ICU patients were enrolled into the study group.The control group consisted of 90 patients who underwent interventional therapy.All patients had bedside TTE for parametric measurements including the right ventricular size,septal kinetics and left ventricular ejection fraction(LVEF)by eyeballing(visual assessment),the tricuspid annular plane systolic excursion(TAPSE),mitral annular plane systolic excursion(MAPSE)by M-mode sonography,the right ventricular outflow tract velocity-time integral(RVOT VTI)and left ventricular outflow tract velocity-time integral(LVOT VTI)by pulse-Doppler,the right ventricular fraction of area change(FAC)and left ventricular ejection fraction(LVEF Simpson)by endocardium tracing.We compared the differences in the frequency of optimal image acquisition in assessments of these parameters between the two groups,as well as the differences in acquisition rates of parameter measurements in ventilated ICU patients.Results There were significantly fewer patients in the study group than in the control group who had optimal images acquisitions for parameter assessments with M-mode method,pulse Doppler method and endocardiumtracing method(P<0.05);no significant difference was obsered in the number of patients with optimal images for RV eyeballing and LVEF eyeballing between the two groups.In the study group,significantly fewer optimal images were acquired for FAC than forTAPSE(22.2%vs、72.2%,χ2=45.139,P<0.001)and RVOT VTI(22.2%vs.71.1%,χ2=43.214,P<0.001);there were also fewer optimal images acquired for LVEF Simpson than for MAPSE(37.8%ys.84.4%,χ2=41.236,P<0.001)and LVOT VTI(37.8%vs.85.6%,/=43.455,P<0.001).Conclusions Images acquisition of optimal TTE images tend to be difRcult in mechanically ventilated ICU patients,but eyeballing method for functional evaluation could be an alternative method.For quantitative parameters measurements,M-mode based longitudinal function evaluation and pulse Doppler-based VTI were superior to the endocardium-tracing based parameter assessments. 展开更多
关键词 critically ill transthoracic echocardiography medical image
在线阅读 下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部