A measurement system for the scattering characteristics of warhead fragments based on high-speed imaging systems offers advantages such as simple deployment,flexible maneuverability,and high spatiotemporal resolution,...A measurement system for the scattering characteristics of warhead fragments based on high-speed imaging systems offers advantages such as simple deployment,flexible maneuverability,and high spatiotemporal resolution,enabling the acquisition of full-process data of the fragment scattering process.However,mismatches between camera frame rates and target velocities can lead to long motion blur tails of high-speed fragment targets,resulting in low signal-to-noise ratios and rendering conventional detection algorithms ineffective in dynamic strong interference testing environments.In this study,we propose a detection framework centered on dynamic strong interference disturbance signal separation and suppression.We introduce a mixture Gaussian model constrained under a joint spatialtemporal-transform domain Dirichlet process,combined with total variation regularization to achieve disturbance signal suppression.Experimental results demonstrate that the proposed disturbance suppression method can be integrated with certain conventional motion target detection tasks,enabling adaptation to real-world data to a certain extent.Moreover,we provide a specific implementation of this process,which achieves a detection rate close to 100%with an approximate 0%false alarm rate in multiple sets of real target field test data.This research effectively advances the development of the field of damage parameter testing.展开更多
We report direct nanoscale imaging of ultrafast plasmon in a gold dolmen nanostructure excited with the 7is laser pulses by combining the interferometric time-resolved technology with the three-photon photoemission el...We report direct nanoscale imaging of ultrafast plasmon in a gold dolmen nanostructure excited with the 7is laser pulses by combining the interferometric time-resolved technology with the three-photon photoemission electron microscopy (PEEM). The interferometric time-resolved traces show that the plasmon mode beating pattern appears at the ends of the dimer slabs in the dolmen nanostructure as a result of coherent superposition of multiple localized surface plasmon modes induced by broad bandwidth of the ultrafast laser pulses. The PEEM measurement further discloses that in-phase of the oscillation field of two neighbor defects are surprisingly observed, which is attributed to the plasmon coupling between them. Furthermore, the control of the temporal delay between the pump and probe laser pluses could be utilized for manipulation of the near-field distribution. These findings deepen our understanding of ultrafast plasmon dynamics in a complex nanosystem.展开更多
Objective:To introduce a new better contrast-enhanced MR angiographic metnod, named 3D time-resolved imaging of contrast kinetics (3D-TRICKS). Methods: TRICKS is a high temporal resolution (2-6 s) MR angiographi...Objective:To introduce a new better contrast-enhanced MR angiographic metnod, named 3D time-resolved imaging of contrast kinetics (3D-TRICKS). Methods: TRICKS is a high temporal resolution (2-6 s) MR angiographic technique using a short TR(4 ms) and TE(1.5 ms), partial echo sampling, in which central part of k-space is updated more frequently than the peripheral part. TRICKS pre-contrast mask 3D images are firstly scanned, and then the bolus injecting of Gd-DTPA, 15-20 sequential 3D images are acquired. The reconstructed 3D images, subtraction of contrast 3D images with mask images, are conceptually similar to a catheter-based intra-arterial digital subtraction angiographic series (DSA). Thirty patients underwent contrast-enhanced MR angiography using 3D-TRICKS. Results: Totally 12 vertebral arteries were well displayed on TRICKS, in which 7 were normal, 1 demonstrated bilateral vertebral artery stenosis, 4 had unilateral vertebral artery stenosis and 1 was accompanied with the same lateral carotid artery bifurcation stenosis. Four cases of bilateral renal arteries were normal, 1 transplanted kidney artery showed as normal and 1 transplanted kidney artery showed stenosis. 2 cerebral arteries were normal, 1 had sagittal sinus thrombosis and 1 displayed intracranial arteriovenous malformation. 3 pulmonary arteries were normal, 1 showed pulmonary artery thrombosis and 1 revealed pulmonary sequestration's abnormal feeding artery and draining vein. One left lower limb fibrolipoma showed feeding artery. One displayed radial-ulnar artery artificial fistula stenosis. One revealed left antebrachium hemangioma. Conclusion: TRICKS can clearly delineate most body vascular system and reveal most vascular abnormality. It possesses convenience and high successful rate, which make it the first choice of displaying most vascular abnormality.展开更多
Objective:To investigate the relationship between dynamic contrast-enhanced MRI parameters and tumor angiogenesis in peripheral pulmonary adenocarcinoma.Methods:Thirty-seven patients with pathologic proved pulmonary a...Objective:To investigate the relationship between dynamic contrast-enhanced MRI parameters and tumor angiogenesis in peripheral pulmonary adenocarcinoma.Methods:Thirty-seven patients with pathologic proved pulmonary adenocarcinoma underwent dynamic contrast-enhanced MR Imaging. Microvessel density(MVD) was counted and vascular endothelial growth factor(VEGF) expression was assessed with immunohistochemical method. Dynamic contrast-enhanced MRI-derived parameters, such as peak height(PH), steepest slope(SS), maximum enhancement rate(E max),enhancement rate at 1-6 minutes(E 1-6), were calculated and compared with MVD in pulmonary adenocarcinoma. And the parameters were also compared between VEGF-positive and VEGF-negative pulmonary adenocarcinoma. Results:The microvessel density was 68.31±19.84 in 37 pulmonary adenocarcinoma. The PH, SS, E max, E 1-6 correlated positively with MVD respectively(P<0.001). The strongest relationship was found between SS and MVD(r=0.827,P<0.001). There was a significant difference between MVD of VEGF-positive pulmonary adenocarcinoma (79.47±21.35) and MVD of VEGF-negative pulmonary adenocarcinoma (43.16±17.85)(P<0.001). All the parameters in VEGF-positive pulmonary adenocarcinoma were higher than those in VEGF-negative pulmonary adenocarcinao(P<0.001). Conclusion: Dynamic contrast-enhanced MRI-derived parameters of pulmonary adenocarcinoma correlated positively with MVD. The parameters in VEGF-positive pulmonary adenocarcinoma were higher than those in VEGF-negative pulmonary adenocarcinoma(P<0.001).展开更多
We experimentally observe the dynamic evolution of atoms in the evaporative cooling, by in-situ imaging the plugged hole of ultracold atoms. Ultracold rubidium atoms confined in a magnetic trap are plugged using a blu...We experimentally observe the dynamic evolution of atoms in the evaporative cooling, by in-situ imaging the plugged hole of ultracold atoms. Ultracold rubidium atoms confined in a magnetic trap are plugged using a blue-detuned laser beam with a waist of 20 m at a wavelength of 767 nm. We probe the variation of the atomic temperature and width versus the radio frequency in the evaporative cooling. Both the behaviors are in good agreement with the calculation of the trapping potential dressed by the rf signal above the threshold temperature,while deviating from the calculation near the phase transition. To accurately obtain the atomic width, we use the plugged hole as the reference to optimize the optical imaging system by precisely minimizing the artificial structures due to the defocus effect.展开更多
An improved estimation of motion vectors of feature points is proposed for tracking moving objects of dynamic image sequence. Feature points are firstly extracted by the improved minimum intensity change (MIC) algor...An improved estimation of motion vectors of feature points is proposed for tracking moving objects of dynamic image sequence. Feature points are firstly extracted by the improved minimum intensity change (MIC) algorithm. The matching points of these feature points are then determined by adaptive rood pattern searching. Based on the random sample consensus (RANSAC) method, the background motion is finally compensated by the parameters of an affine transform of the background motion. With reasonable morphological filtering, the moving objects are completely extracted from the background, and then tracked accurately. Experimental results show that the improved method is successful on the motion background compensation and offers great promise in tracking moving objects of the dynamic image sequence.展开更多
The fast X-ray imaging beamline(BL16U2)at Shanghai Synchrotron Radiation Facility(SSRF)is a new beamline that provides X-ray micro-imaging capabilities across a wide range of time scales,spanning from 100 ps toμs and...The fast X-ray imaging beamline(BL16U2)at Shanghai Synchrotron Radiation Facility(SSRF)is a new beamline that provides X-ray micro-imaging capabilities across a wide range of time scales,spanning from 100 ps toμs and ms.This beamline has been specifically designed to facilitate the investigation of a wide range of rapid phenomena,such as the deformation and failure of materials subjected to intense dynamic loads.In addition,it enables the study of high-pressure and high-speed fuel spray processes in automotive engines.The light source of this beamline is a cryogenic permanent magnet undulator(CPMU)that is cooled by liquid nitrogen.This CPMU can generate X-ray photons within an energy range of 8.7-30 keV.The beamline offers two modes of operation:monochromatic beam mode with a liquid nitrogen-cooled double-crystal monochromator(DCM)and pink beam mode with the first crystal of the DCM out of the beam path.Four X-ray imaging methods were implemented in BL16U2:single-pulse ultrafast X-ray imaging,microsecond-resolved X-ray dynamic imaging,millisecond-resolved X-ray dynamic micro-CT,and high-resolution quantitative micro-CT.Furthermore,BL16U2 is equipped with various in situ impact loading systems,such as a split Hopkinson bar system,light gas gun,and fuel spray chamber.Following the completion of the final commissioning in 2021 and subsequent trial operations in 2022,the beamline has been officially available to users from 2023.展开更多
The dynamic multichannel binocular visual image modeling is studied based on Internet of Things (IoT) Perception Layer, using mobile robot self-organizing network. By employing multigroup mobile robots with binocular ...The dynamic multichannel binocular visual image modeling is studied based on Internet of Things (IoT) Perception Layer, using mobile robot self-organizing network. By employing multigroup mobile robots with binocular visual system, the real visual images of the object will be obtained. Then through the mobile self-organizing network, a three-dimensional model is rebuilt by synthesizing the returned images. On this basis, we formalize a novel algorithm for multichannel binocular visual three-dimensional images based on fast three-dimensional modeling. Compared with the method based on single binocular visual system, the new algorithm can improve the Integrity and accuracy of the dynamic three-dimensional object modeling. The simulation results show that the new method can effectively accelerate the modeling speed, improve the similarity and not increase the data size.展开更多
Distortion-free data embedding is a technique which can assure that not only the secret data is correctly extracted but also the cover media is recovered without any distortion after secret data is extracted completel...Distortion-free data embedding is a technique which can assure that not only the secret data is correctly extracted but also the cover media is recovered without any distortion after secret data is extracted completely. Because of these advantages, this technique attracts the attention of many researchers. In this paper, a new distortion-free data embedding scheme for high dynamic range (HDR) images is proposed. By depending on Cartesian product, this scheme can obtain higher embedding capacity while maintaining the exactly identical cover image and stego image when using the tone mapping algorithms. In experimental results, the proposed scheme is superior to Yu et aL's scheme in regard to the embedding rate——an average embedding rate of 0.1355 bpp compared with Yn et aL's scheme (0.1270 bpp).展开更多
Image is not only an essential part,but also a major means to convey the implications in English poems.It is a literal and concrete representation of a sensory experience of an object.The rendering of images in Englis...Image is not only an essential part,but also a major means to convey the implications in English poems.It is a literal and concrete representation of a sensory experience of an object.The rendering of images in English poems into Chinese can be guided by the dynamic equivalent translation theory put forward by Dr.Eugene A Nida.The theory emphasizes the roughly equivalent response of the target language receptors to the TL text to that of the source language receptors to the SL text.To achieve a Dynamic Equivalence,methods like Direct Translation,Addition,and Substitution can be employed in the translation of images in English poems.展开更多
This paper introduces some latest developments regarding the X-ray imaging methodology and applications of the X-ray imaging and biomedical application beamline(BL13W1)at Shanghai Synchrotron Radiation Facility in the...This paper introduces some latest developments regarding the X-ray imaging methodology and applications of the X-ray imaging and biomedical application beamline(BL13W1)at Shanghai Synchrotron Radiation Facility in the past 5 years.The photon energy range of the beamline is 8–72.5 keV.Several sets of X-ray imaging detectors with different pixel sizes(0.19–24 lm)are used to realize X-ray microcomputed tomography(X-ray micro-CT)and X-ray in-line phase-contrast imaging.To satisfy the requirements of user experiments,new X-ray imaging methods and image processing techniques are developed.In vivo dynamic micro-CT experiments with living insects are performed in 0.5 s(sampling rate of 2 Hz,2 tomograms/s)with a monochromatic beam from a wiggler source and in 40 ms(sampling rate of 25 Hz,25 tomograms/s)with a white beam from a bending magnet source.A new X-ray imaging method known as move contrast X-ray imaging is proposed,with which blood flow and moving tissues in raw images can be distinguished according to their moving frequencies in the time domain.Furthermore,X-ray speckle-tracking imaging with twice exposures to eliminate the edge enhancement effect is developed.A high-precision quantification method is realized to measure complex three-dimensional blood vessels obtained via X-ray micro-CT.X-ray imaging methods such as three-dimensional X-ray diffraction microscopy,small-angle X-ray scattering CT,and X-ray fluorescence CT are developed,in which the X-ray micro-CT imaging method is combined with other contrast mechanisms such as diffraction,scattering,and fluorescence contrasts respectively.Moreover,an X-ray nano-CT experiment is performed with a 100 nm spatial resolution.Typical user experimental results from the fields of material science,biomedicine,paleontology,physics,chemistry,and environmental science obtained on the beamline are provided.展开更多
To evaluate the performance of basic shape representation methods for the description of dynamic cellular morphology, several frequently-used shape descriptors are compared. The methods are examined by using 50 lympho...To evaluate the performance of basic shape representation methods for the description of dynamic cellular morphology, several frequently-used shape descriptors are compared. The methods are examined by using 50 lymphocyte video clips including two kinds of lymphocyte cells. Our goal is to represent cell shape in each frame accurately, meanwhile precisely classify the two groups of cells based on the cellular morphological variations in the video clips. Experimental results illustrate that in general the region-based shape descriptors outperform the contour-based ones, since the contourbased methods are excessively sensitive and ignorant to cellular internal information. Due to their robustness to noise, the region-based shape descriptors are suitable for dynamic cell representation. Although region-based methods are more time-consuming, they analyze the entire cell area.展开更多
A galvanometric scanner with a dynamic focus was designed using a PC to realize the model transform of the image, calculate the interpolation points of the image, and implement the focus compensation of the dynamic fo...A galvanometric scanner with a dynamic focus was designed using a PC to realize the model transform of the image, calculate the interpolation points of the image, and implement the focus compensation of the dynamic focus system. The interrupt of PC was used for the real-time control. It was confirmed that the PC-based galvanometric scanner with dynamic focus could run more than 72 h stably, with an accuracy of 100 ±0.1 mm, and the period of real-time control was less than 20μs.展开更多
Speedometer identification has been researched for many years.The common approaches to that problem are usually based on image subtraction,which does not adapt to image offsets caused by camera vibration.To cope with ...Speedometer identification has been researched for many years.The common approaches to that problem are usually based on image subtraction,which does not adapt to image offsets caused by camera vibration.To cope with the rapidity,robust and accurate requirements of this kind of work in dynamic scene,a fast speedometer identification algorithm is proposed,it utilizes phase correlation method based on regional entire template translation to estimate the offset between images.In order to effectively reduce unnecessary computation and false detection rate,an improved linear Hough transform method with two optimization strategies is presented for pointer line detection.Based on VC++ 6.0 software platform with OpenCV library,the algorithm performance under experiments has shown that it celerity and precision.展开更多
Taking an image of their structure and a movie of their dynamics of small quantum systems have always been a dream of physicists and chemists. Laser-induced Coulomb explosion imaging(CEI) provides a great opportunity ...Taking an image of their structure and a movie of their dynamics of small quantum systems have always been a dream of physicists and chemists. Laser-induced Coulomb explosion imaging(CEI) provides a great opportunity to make this dream a reality for small molecules or their aggregation — clusters. The method is unique for identifying the atomic locations with angstrom spatial resolution and capturing the structural evolution with a femtosecond time scale, in particular for imaging transient state products. This review summarizes the determination of three-dimensional equilibrium geometry of molecules and molecular cluster system through the reconstruction from the fragments momenta, and also shows that the dissociation dynamics on the complex potential energy surface can be tracked in real-time with the ultrafast CEI(UCEI).Furthermore, the detailed measurement and analysis procedures of the CEI, theoretical methods, exemplary results, and future perspectives of the technique are described.展开更多
A new X-ray imaging and biomedical application beamline(BL13HB)has been implemented at the Shanghai Radiation Synchrotron Facility(SSRF)as an upgrade to the old X-ray imaging and biomedical application beamline(BL13W1...A new X-ray imaging and biomedical application beamline(BL13HB)has been implemented at the Shanghai Radiation Synchrotron Facility(SSRF)as an upgrade to the old X-ray imaging and biomedical application beamline(BL13W1).This is part of the Phase II construction project of the SSRF.The BL13HB is dedicated to 2D and 3D static and dynamic X-ray imaging,with a field of view of up to 48.5 mm×5.2 mm and spatial resolution as high as 0.8μm.A super-bending magnet is used as the X-ray source in BL13HB,which has a maximum magnetic field of 2.293 T.The energy range of monochromatic X-ray photons from a double-multiplayer monochromator was 8–40 keV,and the white beam mode was provided on the beamline for dynamic X-ray imaging and dynamic X-ray micro-CT.While maintaining the previous experimental setup of BL13W1,new equipment was added to the beamline experimental station.The beamline is equipped with different sets of X-ray imaging detectors for several experimental methods such as micro-CT,dynamic micro-CT,and pair distribution function.The experimental station of BL13HB is designed specifically for various in situ dynamic experiments,and BL13HB has been open to users since June 2021.展开更多
Unmanned aerial vehicles(UAVs)have been widely used in military,medical,wireless communications,aerial surveillance,etc.One key topic involving UAVs is pose estimation in autonomous navigation.A standard procedure for...Unmanned aerial vehicles(UAVs)have been widely used in military,medical,wireless communications,aerial surveillance,etc.One key topic involving UAVs is pose estimation in autonomous navigation.A standard procedure for this process is to combine inertial navigation system sensor information with the global navigation satellite system(GNSS)signal.However,some factors can interfere with the GNSS signal,such as ionospheric scintillation,jamming,or spoofing.One alternative method to avoid using the GNSS signal is to apply an image processing approach by matching UAV images with georeferenced images.But a high effort is required for image edge extraction.Here a support vector regression(SVR)model is proposed to reduce this computational load and processing time.The dynamic partial reconfiguration(DPR)of part of the SVR datapath is implemented to accelerate the process,reduce the area,and analyze its granularity by increasing the grain size of the reconfigurable region.Results show that the implementation in hardware is 68 times faster than that in software.This architecture with DPR also facilitates the low power consumption of 4 mW,leading to a reduction of 57%than that without DPR.This is also the lowest power consumption in current machine learning hardware implementations.Besides,the circuitry area is 41 times smaller.SVR with Gaussian kernel shows a success rate of 99.18%and minimum square error of 0.0146 for testing with the planning trajectory.This system is useful for adaptive applications where the user/designer can modify/reconfigure the hardware layout during its application,thus contributing to lower power consumption,smaller hardware area,and shorter execution time.展开更多
文摘A measurement system for the scattering characteristics of warhead fragments based on high-speed imaging systems offers advantages such as simple deployment,flexible maneuverability,and high spatiotemporal resolution,enabling the acquisition of full-process data of the fragment scattering process.However,mismatches between camera frame rates and target velocities can lead to long motion blur tails of high-speed fragment targets,resulting in low signal-to-noise ratios and rendering conventional detection algorithms ineffective in dynamic strong interference testing environments.In this study,we propose a detection framework centered on dynamic strong interference disturbance signal separation and suppression.We introduce a mixture Gaussian model constrained under a joint spatialtemporal-transform domain Dirichlet process,combined with total variation regularization to achieve disturbance signal suppression.Experimental results demonstrate that the proposed disturbance suppression method can be integrated with certain conventional motion target detection tasks,enabling adaptation to real-world data to a certain extent.Moreover,we provide a specific implementation of this process,which achieves a detection rate close to 100%with an approximate 0%false alarm rate in multiple sets of real target field test data.This research effectively advances the development of the field of damage parameter testing.
基金Supported by the National Basic Research Program of China under Grant No 2013CB922404the National Natural Science Foundation of China under Grant Nos 11474040,11474039,61605017 and 61575030the Project of Changchun Science and Technology Bureau under Grant No 14KP007
文摘We report direct nanoscale imaging of ultrafast plasmon in a gold dolmen nanostructure excited with the 7is laser pulses by combining the interferometric time-resolved technology with the three-photon photoemission electron microscopy (PEEM). The interferometric time-resolved traces show that the plasmon mode beating pattern appears at the ends of the dimer slabs in the dolmen nanostructure as a result of coherent superposition of multiple localized surface plasmon modes induced by broad bandwidth of the ultrafast laser pulses. The PEEM measurement further discloses that in-phase of the oscillation field of two neighbor defects are surprisingly observed, which is attributed to the plasmon coupling between them. Furthermore, the control of the temporal delay between the pump and probe laser pluses could be utilized for manipulation of the near-field distribution. These findings deepen our understanding of ultrafast plasmon dynamics in a complex nanosystem.
文摘Objective:To introduce a new better contrast-enhanced MR angiographic metnod, named 3D time-resolved imaging of contrast kinetics (3D-TRICKS). Methods: TRICKS is a high temporal resolution (2-6 s) MR angiographic technique using a short TR(4 ms) and TE(1.5 ms), partial echo sampling, in which central part of k-space is updated more frequently than the peripheral part. TRICKS pre-contrast mask 3D images are firstly scanned, and then the bolus injecting of Gd-DTPA, 15-20 sequential 3D images are acquired. The reconstructed 3D images, subtraction of contrast 3D images with mask images, are conceptually similar to a catheter-based intra-arterial digital subtraction angiographic series (DSA). Thirty patients underwent contrast-enhanced MR angiography using 3D-TRICKS. Results: Totally 12 vertebral arteries were well displayed on TRICKS, in which 7 were normal, 1 demonstrated bilateral vertebral artery stenosis, 4 had unilateral vertebral artery stenosis and 1 was accompanied with the same lateral carotid artery bifurcation stenosis. Four cases of bilateral renal arteries were normal, 1 transplanted kidney artery showed as normal and 1 transplanted kidney artery showed stenosis. 2 cerebral arteries were normal, 1 had sagittal sinus thrombosis and 1 displayed intracranial arteriovenous malformation. 3 pulmonary arteries were normal, 1 showed pulmonary artery thrombosis and 1 revealed pulmonary sequestration's abnormal feeding artery and draining vein. One left lower limb fibrolipoma showed feeding artery. One displayed radial-ulnar artery artificial fistula stenosis. One revealed left antebrachium hemangioma. Conclusion: TRICKS can clearly delineate most body vascular system and reveal most vascular abnormality. It possesses convenience and high successful rate, which make it the first choice of displaying most vascular abnormality.
文摘Objective:To investigate the relationship between dynamic contrast-enhanced MRI parameters and tumor angiogenesis in peripheral pulmonary adenocarcinoma.Methods:Thirty-seven patients with pathologic proved pulmonary adenocarcinoma underwent dynamic contrast-enhanced MR Imaging. Microvessel density(MVD) was counted and vascular endothelial growth factor(VEGF) expression was assessed with immunohistochemical method. Dynamic contrast-enhanced MRI-derived parameters, such as peak height(PH), steepest slope(SS), maximum enhancement rate(E max),enhancement rate at 1-6 minutes(E 1-6), were calculated and compared with MVD in pulmonary adenocarcinoma. And the parameters were also compared between VEGF-positive and VEGF-negative pulmonary adenocarcinoma. Results:The microvessel density was 68.31±19.84 in 37 pulmonary adenocarcinoma. The PH, SS, E max, E 1-6 correlated positively with MVD respectively(P<0.001). The strongest relationship was found between SS and MVD(r=0.827,P<0.001). There was a significant difference between MVD of VEGF-positive pulmonary adenocarcinoma (79.47±21.35) and MVD of VEGF-negative pulmonary adenocarcinoma (43.16±17.85)(P<0.001). All the parameters in VEGF-positive pulmonary adenocarcinoma were higher than those in VEGF-negative pulmonary adenocarcinao(P<0.001). Conclusion: Dynamic contrast-enhanced MRI-derived parameters of pulmonary adenocarcinoma correlated positively with MVD. The parameters in VEGF-positive pulmonary adenocarcinoma were higher than those in VEGF-negative pulmonary adenocarcinoma(P<0.001).
基金Supported by the National Key Research and Development Program of China under Grant No 2016YFA0301503the National Natural Science Foundation of China under Grant Nos 11674358 and 11434015the Instrument Project of the Chinese Academy of Sciences under Grant No YJKYYQ20170025
文摘We experimentally observe the dynamic evolution of atoms in the evaporative cooling, by in-situ imaging the plugged hole of ultracold atoms. Ultracold rubidium atoms confined in a magnetic trap are plugged using a blue-detuned laser beam with a waist of 20 m at a wavelength of 767 nm. We probe the variation of the atomic temperature and width versus the radio frequency in the evaporative cooling. Both the behaviors are in good agreement with the calculation of the trapping potential dressed by the rf signal above the threshold temperature,while deviating from the calculation near the phase transition. To accurately obtain the atomic width, we use the plugged hole as the reference to optimize the optical imaging system by precisely minimizing the artificial structures due to the defocus effect.
文摘An improved estimation of motion vectors of feature points is proposed for tracking moving objects of dynamic image sequence. Feature points are firstly extracted by the improved minimum intensity change (MIC) algorithm. The matching points of these feature points are then determined by adaptive rood pattern searching. Based on the random sample consensus (RANSAC) method, the background motion is finally compensated by the parameters of an affine transform of the background motion. With reasonable morphological filtering, the moving objects are completely extracted from the background, and then tracked accurately. Experimental results show that the improved method is successful on the motion background compensation and offers great promise in tracking moving objects of the dynamic image sequence.
基金supported by the CAS Project for Young Scientists in Basic Research(YSBR-096)the National Major Scientific Instruments and Equipment Development Project of China(No.11627901)+1 种基金the National Key Research and Development Program of China(Nos.2021YFF0701202,2021YFA1600703)the National Natural Science Foundation of China(Nos.U1932205,12275343).
文摘The fast X-ray imaging beamline(BL16U2)at Shanghai Synchrotron Radiation Facility(SSRF)is a new beamline that provides X-ray micro-imaging capabilities across a wide range of time scales,spanning from 100 ps toμs and ms.This beamline has been specifically designed to facilitate the investigation of a wide range of rapid phenomena,such as the deformation and failure of materials subjected to intense dynamic loads.In addition,it enables the study of high-pressure and high-speed fuel spray processes in automotive engines.The light source of this beamline is a cryogenic permanent magnet undulator(CPMU)that is cooled by liquid nitrogen.This CPMU can generate X-ray photons within an energy range of 8.7-30 keV.The beamline offers two modes of operation:monochromatic beam mode with a liquid nitrogen-cooled double-crystal monochromator(DCM)and pink beam mode with the first crystal of the DCM out of the beam path.Four X-ray imaging methods were implemented in BL16U2:single-pulse ultrafast X-ray imaging,microsecond-resolved X-ray dynamic imaging,millisecond-resolved X-ray dynamic micro-CT,and high-resolution quantitative micro-CT.Furthermore,BL16U2 is equipped with various in situ impact loading systems,such as a split Hopkinson bar system,light gas gun,and fuel spray chamber.Following the completion of the final commissioning in 2021 and subsequent trial operations in 2022,the beamline has been officially available to users from 2023.
基金supported by HiTech Researchand Development Program of China under Grant No.2007AA10Z235
文摘The dynamic multichannel binocular visual image modeling is studied based on Internet of Things (IoT) Perception Layer, using mobile robot self-organizing network. By employing multigroup mobile robots with binocular visual system, the real visual images of the object will be obtained. Then through the mobile self-organizing network, a three-dimensional model is rebuilt by synthesizing the returned images. On this basis, we formalize a novel algorithm for multichannel binocular visual three-dimensional images based on fast three-dimensional modeling. Compared with the method based on single binocular visual system, the new algorithm can improve the Integrity and accuracy of the dynamic three-dimensional object modeling. The simulation results show that the new method can effectively accelerate the modeling speed, improve the similarity and not increase the data size.
文摘Distortion-free data embedding is a technique which can assure that not only the secret data is correctly extracted but also the cover media is recovered without any distortion after secret data is extracted completely. Because of these advantages, this technique attracts the attention of many researchers. In this paper, a new distortion-free data embedding scheme for high dynamic range (HDR) images is proposed. By depending on Cartesian product, this scheme can obtain higher embedding capacity while maintaining the exactly identical cover image and stego image when using the tone mapping algorithms. In experimental results, the proposed scheme is superior to Yu et aL's scheme in regard to the embedding rate——an average embedding rate of 0.1355 bpp compared with Yn et aL's scheme (0.1270 bpp).
文摘Image is not only an essential part,but also a major means to convey the implications in English poems.It is a literal and concrete representation of a sensory experience of an object.The rendering of images in English poems into Chinese can be guided by the dynamic equivalent translation theory put forward by Dr.Eugene A Nida.The theory emphasizes the roughly equivalent response of the target language receptors to the TL text to that of the source language receptors to the SL text.To achieve a Dynamic Equivalence,methods like Direct Translation,Addition,and Substitution can be employed in the translation of images in English poems.
基金This work was supported by the National Key Research and Development Program of China(Nos.2017YFA0403801,2016YFA0401302,2017YFA0206004,2018YFC1200204)the National Major Scientific Instruments and Equipment Development Project of China(No.11627901).
文摘This paper introduces some latest developments regarding the X-ray imaging methodology and applications of the X-ray imaging and biomedical application beamline(BL13W1)at Shanghai Synchrotron Radiation Facility in the past 5 years.The photon energy range of the beamline is 8–72.5 keV.Several sets of X-ray imaging detectors with different pixel sizes(0.19–24 lm)are used to realize X-ray microcomputed tomography(X-ray micro-CT)and X-ray in-line phase-contrast imaging.To satisfy the requirements of user experiments,new X-ray imaging methods and image processing techniques are developed.In vivo dynamic micro-CT experiments with living insects are performed in 0.5 s(sampling rate of 2 Hz,2 tomograms/s)with a monochromatic beam from a wiggler source and in 40 ms(sampling rate of 25 Hz,25 tomograms/s)with a white beam from a bending magnet source.A new X-ray imaging method known as move contrast X-ray imaging is proposed,with which blood flow and moving tissues in raw images can be distinguished according to their moving frequencies in the time domain.Furthermore,X-ray speckle-tracking imaging with twice exposures to eliminate the edge enhancement effect is developed.A high-precision quantification method is realized to measure complex three-dimensional blood vessels obtained via X-ray micro-CT.X-ray imaging methods such as three-dimensional X-ray diffraction microscopy,small-angle X-ray scattering CT,and X-ray fluorescence CT are developed,in which the X-ray micro-CT imaging method is combined with other contrast mechanisms such as diffraction,scattering,and fluorescence contrasts respectively.Moreover,an X-ray nano-CT experiment is performed with a 100 nm spatial resolution.Typical user experimental results from the fields of material science,biomedicine,paleontology,physics,chemistry,and environmental science obtained on the beamline are provided.
基金Supported by the National Natural Science Foundation of China(61271112)
文摘To evaluate the performance of basic shape representation methods for the description of dynamic cellular morphology, several frequently-used shape descriptors are compared. The methods are examined by using 50 lymphocyte video clips including two kinds of lymphocyte cells. Our goal is to represent cell shape in each frame accurately, meanwhile precisely classify the two groups of cells based on the cellular morphological variations in the video clips. Experimental results illustrate that in general the region-based shape descriptors outperform the contour-based ones, since the contourbased methods are excessively sensitive and ignorant to cellular internal information. Due to their robustness to noise, the region-based shape descriptors are suitable for dynamic cell representation. Although region-based methods are more time-consuming, they analyze the entire cell area.
文摘A galvanometric scanner with a dynamic focus was designed using a PC to realize the model transform of the image, calculate the interpolation points of the image, and implement the focus compensation of the dynamic focus system. The interrupt of PC was used for the real-time control. It was confirmed that the PC-based galvanometric scanner with dynamic focus could run more than 72 h stably, with an accuracy of 100 ±0.1 mm, and the period of real-time control was less than 20μs.
基金Supported by the National Natural Science Foundation of China (61004139)Beijing Municipal Natural Science Foundation(4101001)2008 Yangtze Fund Scholar and Innovative Research Team Development Schemes of Ministry of Education
文摘Speedometer identification has been researched for many years.The common approaches to that problem are usually based on image subtraction,which does not adapt to image offsets caused by camera vibration.To cope with the rapidity,robust and accurate requirements of this kind of work in dynamic scene,a fast speedometer identification algorithm is proposed,it utilizes phase correlation method based on regional entire template translation to estimate the offset between images.In order to effectively reduce unnecessary computation and false detection rate,an improved linear Hough transform method with two optimization strategies is presented for pointer line detection.Based on VC++ 6.0 software platform with OpenCV library,the algorithm performance under experiments has shown that it celerity and precision.
基金Project partially supported by the National Key Research and Development Program of China (Grant Nos. 2019YFA0307700)the National Natural Science Foundation of China (Grant Nos. 12004133, 12074143, 12134005, and 11904210)China Postdoctoral Science Foundation (Grant No. 2021M691220)。
文摘Taking an image of their structure and a movie of their dynamics of small quantum systems have always been a dream of physicists and chemists. Laser-induced Coulomb explosion imaging(CEI) provides a great opportunity to make this dream a reality for small molecules or their aggregation — clusters. The method is unique for identifying the atomic locations with angstrom spatial resolution and capturing the structural evolution with a femtosecond time scale, in particular for imaging transient state products. This review summarizes the determination of three-dimensional equilibrium geometry of molecules and molecular cluster system through the reconstruction from the fragments momenta, and also shows that the dissociation dynamics on the complex potential energy surface can be tracked in real-time with the ultrafast CEI(UCEI).Furthermore, the detailed measurement and analysis procedures of the CEI, theoretical methods, exemplary results, and future perspectives of the technique are described.
基金supported by the National Major Scientific Instruments and Equipment Development Project of China(No.11627901)the National Key Research and Development Program of China(Nos.2021YFF0701202 and 2021YFA1600703)the National Natural Science Foundation of China(Nos.U1932205,12275343)。
文摘A new X-ray imaging and biomedical application beamline(BL13HB)has been implemented at the Shanghai Radiation Synchrotron Facility(SSRF)as an upgrade to the old X-ray imaging and biomedical application beamline(BL13W1).This is part of the Phase II construction project of the SSRF.The BL13HB is dedicated to 2D and 3D static and dynamic X-ray imaging,with a field of view of up to 48.5 mm×5.2 mm and spatial resolution as high as 0.8μm.A super-bending magnet is used as the X-ray source in BL13HB,which has a maximum magnetic field of 2.293 T.The energy range of monochromatic X-ray photons from a double-multiplayer monochromator was 8–40 keV,and the white beam mode was provided on the beamline for dynamic X-ray imaging and dynamic X-ray micro-CT.While maintaining the previous experimental setup of BL13W1,new equipment was added to the beamline experimental station.The beamline is equipped with different sets of X-ray imaging detectors for several experimental methods such as micro-CT,dynamic micro-CT,and pair distribution function.The experimental station of BL13HB is designed specifically for various in situ dynamic experiments,and BL13HB has been open to users since June 2021.
基金financially supported by the National Council for Scientific and Technological Development(CNPq,Brazil),Swedish-Brazilian Research and Innovation Centre(CISB),and Saab AB under Grant No.CNPq:200053/2022-1the National Council for Scientific and Technological Development(CNPq,Brazil)under Grants No.CNPq:312924/2017-8 and No.CNPq:314660/2020-8.
文摘Unmanned aerial vehicles(UAVs)have been widely used in military,medical,wireless communications,aerial surveillance,etc.One key topic involving UAVs is pose estimation in autonomous navigation.A standard procedure for this process is to combine inertial navigation system sensor information with the global navigation satellite system(GNSS)signal.However,some factors can interfere with the GNSS signal,such as ionospheric scintillation,jamming,or spoofing.One alternative method to avoid using the GNSS signal is to apply an image processing approach by matching UAV images with georeferenced images.But a high effort is required for image edge extraction.Here a support vector regression(SVR)model is proposed to reduce this computational load and processing time.The dynamic partial reconfiguration(DPR)of part of the SVR datapath is implemented to accelerate the process,reduce the area,and analyze its granularity by increasing the grain size of the reconfigurable region.Results show that the implementation in hardware is 68 times faster than that in software.This architecture with DPR also facilitates the low power consumption of 4 mW,leading to a reduction of 57%than that without DPR.This is also the lowest power consumption in current machine learning hardware implementations.Besides,the circuitry area is 41 times smaller.SVR with Gaussian kernel shows a success rate of 99.18%and minimum square error of 0.0146 for testing with the planning trajectory.This system is useful for adaptive applications where the user/designer can modify/reconfigure the hardware layout during its application,thus contributing to lower power consumption,smaller hardware area,and shorter execution time.