This research develops a comprehensive method to solve a combinatorial problem consisting of distribution system reconfiguration, capacitor allocation, and renewable energy resources sizing and siting simultaneously a...This research develops a comprehensive method to solve a combinatorial problem consisting of distribution system reconfiguration, capacitor allocation, and renewable energy resources sizing and siting simultaneously and to improve power system's accountability and system performance parameters. Due to finding solution which is closer to realistic characteristics, load forecasting, market price errors and the uncertainties related to the variable output power of wind based DG units are put in consideration. This work employs NSGA-II accompanied by the fuzzy set theory to solve the aforementioned multi-objective problem. The proposed scheme finally leads to a solution with a minimum voltage deviation, a maximum voltage stability, lower amount of pollutant and lower cost. The cost includes the installation costs of new equipment, reconfiguration costs, power loss cost, reliability cost, cost of energy purchased from power market, upgrade costs of lines and operation and maintenance costs of DGs. Therefore, the proposed methodology improves power quality, reliability and security in lower costs besides its preserve, with the operational indices of power distribution networks in acceptable level. To validate the proposed methodology's usefulness, it was applied on the IEEE 33-bus distribution system then the outcomes were compared with initial configuration.展开更多
In distributed parallel server system, location and redundancy of repficas have great influence on availability and efficiency of the system. In order to improve availability and efficiency of the system, two phase de...In distributed parallel server system, location and redundancy of repficas have great influence on availability and efficiency of the system. In order to improve availability and efficiency of the system, two phase decision algorithm of replica allocation is proposed. The algorithm which makes use of auto-regression model dynamically predicts the future count of READ and WRITE operation, and then determines location and redundancy of replicas by considering availability, CPU and bands of the network. The algorithm can not only ensure the requirement of availability, but also reduce the system resources consumed by all the operations in a great scale. Analysis and test show that communication complexity and time complexity of the algorithm satisfy O(n), resource optimizing scale increases with the increase of READ count.展开更多
To improve the total throughput of the uplink orthogonal frequency division multiple access system,a low complexity hybrid power distribution(HPD) combined with subcarrier allocation scheme is proposed.For the fairn...To improve the total throughput of the uplink orthogonal frequency division multiple access system,a low complexity hybrid power distribution(HPD) combined with subcarrier allocation scheme is proposed.For the fairness mechanism for the subcarrier,the inter-cell interference is first analyzed to calculate the capacity of the multi-cell.The user selects the subcarrier with the largest channel gain.Based on the above subcarrier allocation scheme,a new kind of HPD scheme is proposed,which adopts the waterfilling-power-distributed scheme and the equal-power-distributed scheme in the cell-boundary and the cellcenter,respectively.Simulation results show that compared with the waterfilling-power-distributed scheme in the whole cell,the proposed HPD scheme decreases the system complexity significantly,meanwhile its capacity is 2% higher than that of the equal-powerdistributed scheme over the same subcarrier allocation.展开更多
A dynamic multi-beam resource allocation algorithm for large low Earth orbit(LEO)constellation based on on-board distributed computing is proposed in this paper.The allocation is a combinatorial optimization process u...A dynamic multi-beam resource allocation algorithm for large low Earth orbit(LEO)constellation based on on-board distributed computing is proposed in this paper.The allocation is a combinatorial optimization process under a series of complex constraints,which is important for enhancing the matching between resources and requirements.A complex algorithm is not available because that the LEO on-board resources is limi-ted.The proposed genetic algorithm(GA)based on two-dimen-sional individual model and uncorrelated single paternal inheri-tance method is designed to support distributed computation to enhance the feasibility of on-board application.A distributed system composed of eight embedded devices is built to verify the algorithm.A typical scenario is built in the system to evalu-ate the resource allocation process,algorithm mathematical model,trigger strategy,and distributed computation architec-ture.According to the simulation and measurement results,the proposed algorithm can provide an allocation result for more than 1500 tasks in 14 s and the success rate is more than 91%in a typical scene.The response time is decreased by 40%com-pared with the conditional GA.展开更多
智能软开关(soft normally open point, SNOP)凭借其灵活的功率调节能力逐渐应用于配电网中。但由于大量分布式电源(distributed generation, DG)接入,SNOP受到线路容量的限制,调节能力有限。为发挥其最大调节能力,文中提出适用于配电...智能软开关(soft normally open point, SNOP)凭借其灵活的功率调节能力逐渐应用于配电网中。但由于大量分布式电源(distributed generation, DG)接入,SNOP受到线路容量的限制,调节能力有限。为发挥其最大调节能力,文中提出适用于配电系统的SNOP对线路有功功率裕度调节灵敏度的定义,将其作为SNOP调节能力的评价指标,由此建立SNOP的选址优化模型。在此基础上,引入系统节点电压裕度以及线路功率裕度2个安全评价指标,构建以综合运行裕度最大为目标函数的配电网运行优化模型。将上述模型转化为二阶锥模型,通过MATLAB工具实现该问题的有效求解。最后,通过改进的IEEE 33节点算例对所提模型与求解方法进行验证,进一步表明了所提选址方法能够发挥SNOP的最大调节作用,优化控制策略可以实现配电网安全经济运行。展开更多
文摘This research develops a comprehensive method to solve a combinatorial problem consisting of distribution system reconfiguration, capacitor allocation, and renewable energy resources sizing and siting simultaneously and to improve power system's accountability and system performance parameters. Due to finding solution which is closer to realistic characteristics, load forecasting, market price errors and the uncertainties related to the variable output power of wind based DG units are put in consideration. This work employs NSGA-II accompanied by the fuzzy set theory to solve the aforementioned multi-objective problem. The proposed scheme finally leads to a solution with a minimum voltage deviation, a maximum voltage stability, lower amount of pollutant and lower cost. The cost includes the installation costs of new equipment, reconfiguration costs, power loss cost, reliability cost, cost of energy purchased from power market, upgrade costs of lines and operation and maintenance costs of DGs. Therefore, the proposed methodology improves power quality, reliability and security in lower costs besides its preserve, with the operational indices of power distribution networks in acceptable level. To validate the proposed methodology's usefulness, it was applied on the IEEE 33-bus distribution system then the outcomes were compared with initial configuration.
文摘In distributed parallel server system, location and redundancy of repficas have great influence on availability and efficiency of the system. In order to improve availability and efficiency of the system, two phase decision algorithm of replica allocation is proposed. The algorithm which makes use of auto-regression model dynamically predicts the future count of READ and WRITE operation, and then determines location and redundancy of replicas by considering availability, CPU and bands of the network. The algorithm can not only ensure the requirement of availability, but also reduce the system resources consumed by all the operations in a great scale. Analysis and test show that communication complexity and time complexity of the algorithm satisfy O(n), resource optimizing scale increases with the increase of READ count.
基金supported by the National Basic Research Programof China (973 Program) (2007CB310601)the Major Science-Technology Project of Next Generation Wireless Mobile Communication Network (2009ZX03004-001)
文摘To improve the total throughput of the uplink orthogonal frequency division multiple access system,a low complexity hybrid power distribution(HPD) combined with subcarrier allocation scheme is proposed.For the fairness mechanism for the subcarrier,the inter-cell interference is first analyzed to calculate the capacity of the multi-cell.The user selects the subcarrier with the largest channel gain.Based on the above subcarrier allocation scheme,a new kind of HPD scheme is proposed,which adopts the waterfilling-power-distributed scheme and the equal-power-distributed scheme in the cell-boundary and the cellcenter,respectively.Simulation results show that compared with the waterfilling-power-distributed scheme in the whole cell,the proposed HPD scheme decreases the system complexity significantly,meanwhile its capacity is 2% higher than that of the equal-powerdistributed scheme over the same subcarrier allocation.
基金This work was supported by the National Key Research and Development Program of China(2021YFB2900603)the National Natural Science Foundation of China(61831008).
文摘A dynamic multi-beam resource allocation algorithm for large low Earth orbit(LEO)constellation based on on-board distributed computing is proposed in this paper.The allocation is a combinatorial optimization process under a series of complex constraints,which is important for enhancing the matching between resources and requirements.A complex algorithm is not available because that the LEO on-board resources is limi-ted.The proposed genetic algorithm(GA)based on two-dimen-sional individual model and uncorrelated single paternal inheri-tance method is designed to support distributed computation to enhance the feasibility of on-board application.A distributed system composed of eight embedded devices is built to verify the algorithm.A typical scenario is built in the system to evalu-ate the resource allocation process,algorithm mathematical model,trigger strategy,and distributed computation architec-ture.According to the simulation and measurement results,the proposed algorithm can provide an allocation result for more than 1500 tasks in 14 s and the success rate is more than 91%in a typical scene.The response time is decreased by 40%com-pared with the conditional GA.
文摘智能软开关(soft normally open point, SNOP)凭借其灵活的功率调节能力逐渐应用于配电网中。但由于大量分布式电源(distributed generation, DG)接入,SNOP受到线路容量的限制,调节能力有限。为发挥其最大调节能力,文中提出适用于配电系统的SNOP对线路有功功率裕度调节灵敏度的定义,将其作为SNOP调节能力的评价指标,由此建立SNOP的选址优化模型。在此基础上,引入系统节点电压裕度以及线路功率裕度2个安全评价指标,构建以综合运行裕度最大为目标函数的配电网运行优化模型。将上述模型转化为二阶锥模型,通过MATLAB工具实现该问题的有效求解。最后,通过改进的IEEE 33节点算例对所提模型与求解方法进行验证,进一步表明了所提选址方法能够发挥SNOP的最大调节作用,优化控制策略可以实现配电网安全经济运行。