期刊文献+
共找到56篇文章
< 1 2 3 >
每页显示 20 50 100
Relative orbit determination algorithm of space targets with passive observation
1
作者 DAI Chenchao QIANG Hongfu +2 位作者 ZHANG Degang HU Shaolei GONG Baichun 《Journal of Systems Engineering and Electronics》 SCIE CSCD 2024年第3期793-804,共12页
Angles-only relative orbit determination for space non-cooperative targets based on passive sensor is subject to weakly observable problem of the relative state between two spacecraft. Previously, the evidence for ang... Angles-only relative orbit determination for space non-cooperative targets based on passive sensor is subject to weakly observable problem of the relative state between two spacecraft. Previously, the evidence for angles-only observability was found by using cylindrical dynamics, however, the solution of orbit determination is still not provided. This study develops a relative orbit determination algorithm with the cylindrical dynamics based on differential evolution. Firstly, the relative motion dynamics and line-of-sight measurement model for nearcircular orbit are established in cylindrical coordinate system.Secondly, the observability is qualitatively analyzed by using the dynamics and measurement model where the unobservable geometry is found. Then, the angles-only relative orbit determination problem is modeled into an optimal searching frame and an improved differential evolution algorithm is introduced to solve the problem. Finally, the proposed algorithm is verified and tested by a set of numerical simulations in the context of highEarth and low-Earth cases. The results show that initial relative orbit determination(IROD) solution with an appropriate accuracy in a relative short span is achieved, which can be used to initialize the navigation filter. 展开更多
关键词 angles-only measurement relative orbit determination cylindrical coordinate differential evolution
在线阅读 下载PDF
Study on multi-wavelength thin film thickness determination method
2
作者 SHI Ce XIE Mao-Bin +3 位作者 ZHENG Wei-Bo JI Ruo-Nan WANG Shao-Wei LU Wei 《红外与毫米波学报》 CSCD 北大核心 2024年第6期813-819,共7页
This work introduces a novel method for measuring thin film thickness,employing a multi-wavelength method that significantly reduces the need for broad-spectrum data.Unlike traditional techniques that require sev⁃eral... This work introduces a novel method for measuring thin film thickness,employing a multi-wavelength method that significantly reduces the need for broad-spectrum data.Unlike traditional techniques that require sev⁃eral hundred spectral data points,the multi-wavelength method achieves precise thickness measurements with data from only 10 wavelengths.This innovation not only simplifies the process of spectral measurement analysis but also enables accurate real-time thickness measurement on industrial coating production lines.The method effectively reconstructs and fits the visible spectrum(400-800 nm)using a minimal amount of data,while maintaining measurement error within 7.1%.This advancement lays the foundation for more practical and efficient thin film thickness determination techniques in various industrial applications. 展开更多
关键词 film thickness determination transmittance and reflectance spectra FITTING spectral reconstruction
在线阅读 下载PDF
Determination of ultimate bearing capacity of uplift piles using intact and non-intact load−displacement curve 被引量:7
3
作者 WANG Qin-ke MAJian-lin +2 位作者 JI Yu-kun ZHANG Jian CHEN Wen-long 《Journal of Central South University》 SCIE EI CAS CSCD 2022年第2期470-485,共16页
Based on the field destructive test of six rock-socketed piles with shallow overburden,three prediction models are used to quantitatively analyze and predict the intact load−displacement curve.The predicted values of ... Based on the field destructive test of six rock-socketed piles with shallow overburden,three prediction models are used to quantitatively analyze and predict the intact load−displacement curve.The predicted values of ultimate uplift capacity were further determined by four methods(displacement controlling method(DCM),reduction coefficient method(RCM),maximum curvature method(MCM),and critical stiffness method(CSM))and compared with the measured value.Through the analysis of the relationship between the change rate of pullout stiffness and displacement,a method used to determine the ultimate uplift capacity via non-intact load−displacement curve was proposed.The results show that the predicted value determined by DCM is more conservative,while the predicted value determined by MCM is larger than the measured value.This suggests that RCM and CSM in engineering applications can be preferentially applied.Moreover,the development law of the change rate of pullout stiffness with displacement agrees well with the attenuation form of power function.The theoretical predicted results of ultimate uplift capacity based on the change rate of pullout stiffness will not be affected by the integrity of the curve.The method is simple and applicable for the piles that are not loaded to failure state,and thus provides new insights into ultimate uplift capacity determination of test piles. 展开更多
关键词 load−displacement curve prediction model determination method of bearing capacity change rate of pullout stiffness
在线阅读 下载PDF
Design and application of single-antenna GPS/accelerometers attitude determination system 被引量:4
4
作者 He Jie Huang Xianlin Wang Guofeng 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2008年第2期220-227,共8页
In view of the problem that the current single-antenna GPS attitude determination system can only determine the body attitude when the sideslip angle is zero and the multiantenna GPS/SINS integrated navigation system ... In view of the problem that the current single-antenna GPS attitude determination system can only determine the body attitude when the sideslip angle is zero and the multiantenna GPS/SINS integrated navigation system is of large volume, high cost, and complex structure, this approach is presented to determine the attitude based on vector space with single-antenna GPS and accelerometers in the micro inertial measurement unit (MIMU). It can provide real-time and accurate attitude information. Subsequently, the single-antenna GPS/SINS integrated navigation system is designed based on the combination of position, velocity, and attitude. Finally the semi- physical simulations of single-antenna GPS attitude determination system and single-antenna GPS/SINS integrated navigation system are carried out. The simulation results, based on measured data, show that the single-antenna GPS/SINS system can provide more accurate navigation information compared to the GPS/SINS system, based on the combination of position and velocity. Furthermore, the single-antenna GPS/SINS system is characteristic of lower cost and simpler structure. It provides the basis for the application of a single-antenna GPS/SINS integrated navigation system in a micro aerial vehicle (MAV). 展开更多
关键词 single-antenna GPS attitude determination vector space ACCELEROMETER integrated navigation MAV.
在线阅读 下载PDF
Reagent optimization for on-line simultaneous polarographic determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in the presence of anextremely large excess of Zn^(2+) 被引量:4
5
作者 WANG Guo-wei YANG Chun-hua +2 位作者 ZHU Hong-qiu LI Yong-gang GUI Wei-hua 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第9期2199-2204,共6页
Reagents are optimized for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in zinc sulfate solution, which contains an extremely large excess of Zn^(2+). First, the reagents and their d... Reagents are optimized for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in zinc sulfate solution, which contains an extremely large excess of Zn^(2+). First, the reagents and their doses for the experiment are selected according to the characteristics of the zinc sulfate solution. Then, the reagent doses are optimized by analyzing the influence of reagent dose on the polarographic parameters(i.e. half-wave potential E_(1/2) and limiting diffusion current I_p). Finally, the optimization results are verified by simultaneously determining trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in the presence of an extremely large excess of Zn^(2+). The determination results indicate that the optimized reagents exhibit wide linearity, low detection limits, high accuracy and good precision for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in the presence of an extremely large excess of Zn^(2+). 展开更多
关键词 on-line simultaneous determination trace polymetallic ions reagent optimization high concentration ratio
在线阅读 下载PDF
Determination of trace multi-elements in coal fly ash by inductively coupled plasma mass spectrometry 被引量:5
6
作者 谢华林 唐有根 +1 位作者 李玉杰 李立波 《Journal of Central South University of Technology》 EI 2007年第1期68-72,共5页
The contents of Cr, Cu, Ni, As, Cd and Pb in coal fly ash were determined by a high resolution inductively coupled plasma mass spectrometry method. The sample digestions were performed in closed microwave vessels with... The contents of Cr, Cu, Ni, As, Cd and Pb in coal fly ash were determined by a high resolution inductively coupled plasma mass spectrometry method. The sample digestions were performed in closed microwave vessels with HNO3, HClO4 and FIE The optimum conditions for the determination were obtained. The applicability of the proposed method was validated by the analysis of coal fly ash reference material (NIST SRM 1633a). The results show that most of the spectral interferences can be avoided by measuring in the high resolution mode (maximum mass resolution R=9 000). The detection limit is from 0.05 to 0.21 μg/g, and the precision is fine with relative standard deviation less than 4.3%. 展开更多
关键词 coal fly ash microwave digestion inductively coupled plasma mass spectrometry determination
在线阅读 下载PDF
Catalytic Wave of Cobalt and its Analytical Application in Rapid Determination of Trace Cobalt in Complex Zinc Electrolyte Solution 被引量:1
7
作者 ZHANG Ming-hao ZHOU Chun-shan LIU Qian-hui 《Journal of Central South University》 SCIE EI CAS 2000年第2期84-87,共4页
A polarographic catalytic wave of cobalt in the substrate solution (pH=8.5) of diacetyldioxime potassium pyrophosphate ammonium chloride was studied and a new method for rapid determination of trace cobalt in complex ... A polarographic catalytic wave of cobalt in the substrate solution (pH=8.5) of diacetyldioxime potassium pyrophosphate ammonium chloride was studied and a new method for rapid determination of trace cobalt in complex zinc electrolyte solution was developed. The results show that there is a very sensitive catalytic wave of cobalt at 1.23 V. At least three hundred thousand fold Zn 2+ does not affect the determination of cobalt. The method is easy to operate and rapid, and when the signal to noise rate equals 2, the detection limit is 6×10 -9 mol·L -1 . A good linear relationship exists between the concentration of cobalt within 0.001 ~3.0 μg·mL -1 and the peak current. The method has successfully been used in the determination of trace cobalt in complex solution of the workshop for electrolyzing zinc. 展开更多
关键词 CATALYTIC wave diacetyldioxime POTASSIUM PYROPHOSPHATE determination COBALT
在线阅读 下载PDF
Error analysis on heading determination via genetic algorithms 被引量:1
8
作者 Zhong Bing Xu Jiangning Ma Heng 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2006年第3期673-676,共4页
A new error analysis method is presented via genetic algorithms for high precise heading determination model based on two total positioning stations (TPSs). The method has the ability to search all possible solution... A new error analysis method is presented via genetic algorithms for high precise heading determination model based on two total positioning stations (TPSs). The method has the ability to search all possible solution space by the genetic operators of elitist model and restriction. The result of analyzing the error of this model shows that the accuracy of this model is precise enough to meet the need of calibration for navigation systems on ship, and the search space is only 0. 03% of the total search space, and the precision of heading determination is 4" in a general dock. 展开更多
关键词 heading determination SGA genetic algorithms.
在线阅读 下载PDF
Distributed adaptive direct position determination based on diffusion framework 被引量:2
9
作者 Wei Xia Wei Liu Lingfeng Zhu 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2016年第1期28-38,共11页
The conventional direct position determination(DPD) algorithm processes all received signals on a single sensor.When sensors have limited computational capabilities or energy storage,it is desirable to distribute th... The conventional direct position determination(DPD) algorithm processes all received signals on a single sensor.When sensors have limited computational capabilities or energy storage,it is desirable to distribute the computation among other sensors.A distributed adaptive DPD(DADPD)algorithm based on diffusion framework is proposed for emitter localization.Unlike the corresponding centralized adaptive DPD(CADPD) algorithm,all but one sensor in the proposed algorithm participate in processing the received signals and estimating the common emitter position,respectively.The computational load and energy consumption on a single sensor in the CADPD algorithm is distributed among other computing sensors in a balanced manner.Exactly the same iterative localization algorithm is carried out in each computing sensor,respectively,and the algorithm in each computing sensor exhibits quite similar convergence behavior.The difference of the localization and tracking performance between the proposed distributed algorithm and the corresponding CADPD algorithm is negligible through simulation evaluations. 展开更多
关键词 emitter localization time difference of arrival(TDOA) direct position determination(DPD) distributed adaptive DPD(DADPD) diffusion framework.
在线阅读 下载PDF
Separation and Determination of Sulfur with Different Valance in Polysulfide Mixture
10
作者 ZHOU Ji-hong CHEN Qi-yuan +1 位作者 ZHANG Ping-min YIN Zhou-lan 《Journal of Central South University》 SCIE EI CAS 2000年第3期149-151,共3页
A new process of separating sulfur with different valance from polysulfide mixtures was developed. Sulfide, sulfite and sulfur were separated by adding acetic acid in one step. The polysulfide mixture, sulfite solutio... A new process of separating sulfur with different valance from polysulfide mixtures was developed. Sulfide, sulfite and sulfur were separated by adding acetic acid in one step. The polysulfide mixture, sulfite solution and sulfur were oxidized to sulfate by hydrogen peroxide. The products were measured by X ray Fluorescence Spectrometer(XRF) using filter method preparative specimen. The measurement needs only one set of standard sample.The effects of temperature and pH values on the separation were discussed. The results show that the recoveries range from 98.0% to 101.3% of sulfidic sulfur S( II), 97.0% to 103.0% for sulfite S(IV) and 98.4% to 100.4% for polysulfidic sulfur S(0). 展开更多
关键词 POLYSULFIDE SEPARATION determination X RAY fluorescence spectrum valance
在线阅读 下载PDF
ON-LINE DETERMINATION OF REMAINED XANTHATE CONCENTRATION IN PULP
11
作者 Huang Ning Mao Anzhang Wang Dianzuo① Li Bodan Sun Shuiyu(Department of Mineral Engineering, Central South University of Technology,Changsha 410083,China) 《Journal of Central South University》 SCIE EI CAS 1998年第1期12-14,共3页
The construction principle of the system for determination of xanthate concentration,which consists of an Ionselective electrode(ISE) and a microprocessor based SDI analyzer,was described in the paper.The performances... The construction principle of the system for determination of xanthate concentration,which consists of an Ionselective electrode(ISE) and a microprocessor based SDI analyzer,was described in the paper.The performances of the developed system were discussed in details.The results both detected in solutions and in sulfide mineral flotation system were given; also the results by ultraviolet spectrometry were compared with those by the developed system. 展开更多
关键词 XANTHATE online determination ion selective ELECTRODE
在线阅读 下载PDF
Identification of variety of rice and determination of content of each rice in mixtures of two rices by nonlinear chemical analysis
12
作者 CHEN Chun-nan XU Tian-shu +9 位作者 ZHONG Jun-hui WANG Zhi-pei LUO Xue-lei GUO Fang-qiu ZHANG Tai-ming DU Juan YANG Chun-hua ZHU Hong-qiu HUANG Jian DENG Fei-yue 《Journal of Central South University》 SCIE EI CAS CSCD 2018年第2期251-258,共8页
Fingerprints of two varieties of rice and their mixtures were investigated by a nonlinear chemical reaction system consisting of rice components,sodium bromate,manganese sulfate,sulfuric acid and acetone.The variety o... Fingerprints of two varieties of rice and their mixtures were investigated by a nonlinear chemical reaction system consisting of rice components,sodium bromate,manganese sulfate,sulfuric acid and acetone.The variety of rice was identified by the visual characteristic of fingerprint and system similarity pattern recognition,and the content of each variety of rice in the mixture was determined by the quantitative information of fingerprint.The results show that nonlinear chemical analysis may be used to exactly identify the variety of pure rice and to accurately determine the content of each variety of rice in the mixture,indicating the method is simple and convenient. 展开更多
关键词 nonlinear chemical analysis binary mixture variety identification content determination RICE
在线阅读 下载PDF
Sensitive determination of DNA based on resonance light scattering enhancement of azocarmine G and CTAB
13
作者 陈展光 任凤莲 +3 位作者 司士辉 廖栩泓 丁卫锋 刘锦斌 《Journal of Central South University of Technology》 EI 2005年第6期688-692,共5页
A new method for the determination of DNA was developed with azocarmine G(AG) in the presence of cetyltrimethylammonium bromide(CTAB) by the resonance light scattering (RLS) technique. The synthetic samples were deter... A new method for the determination of DNA was developed with azocarmine G(AG) in the presence of cetyltrimethylammonium bromide(CTAB) by the resonance light scattering (RLS) technique. The synthetic samples were determined with satisfactory results, and the reaction mechanism was also studied. The results show that underthe optimum conditions, the weak RLS signal of AG can be enhanced by DNA, which results from the formation of a new ternary complex AG-CTAB-DNA with large size. Moreover, the enhanced RLS intensity at 552 nm is directlyproportional to the concentration of DNA in the range of 01.0 μg/mL for fish sperm DNA (fsDNA) and 01.5 μg/mLfor calf thymus DNA (ctDNA). Based on this, a new assay of DNA can be established. The detection limits (3σ) are 2.1 ng/mL for fsDNA and 2.2 ng/mL for ctDNA, respectively. 展开更多
关键词 determination resonance light scattering azocarmine G DNA cetyltrimethylammonium bromide
在线阅读 下载PDF
Selective determination of trace cobalt in zinc electrolytes by second-derivative catalytic polarography
14
作者 ZHU Hong-qiu DU Juan +2 位作者 LI Yong-gang ZHANG Tai-ming CHENG Fei 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第1期207-218,共12页
We report herein a highly selective method for directly determining the trace Co^2+in highly concentrated zinc electrolyte.This novel method is based on a second derivative wave of catalytic adsorptive polarography ge... We report herein a highly selective method for directly determining the trace Co^2+in highly concentrated zinc electrolyte.This novel method is based on a second derivative wave of catalytic adsorptive polarography generated by complexing Co^2+with dimethylglyoxime and nitrite onto a dropping mercury electrode.By employing a medium with NH3-NH4Cl buffer,DMG and NaNO2 during determining the trace Co^2+,any interferences of highly concentrated Zn^2+and other coexisting metal ions in the electrolyte are completely eliminated due to the selective masking effect of EDTA.When the concentration of Co^2+is within 1.0×10^–10–3.2×10^–7 mol/L range,it shows a good linear relationship with the current peak.Detection limit is 1.0×10^–11 mol/L,and RSD≤2.7%for six successive assays.We have compared the efficiency of the current method to that obtained by cobalt nitroso-R-salt spectrophotometry,and the absolute values of relative deviations are≤4.2%.The method developed and described herein has been successfully employed in determining the trace Co2+in actual zinc electrolyte. 展开更多
关键词 catalytic adsorptive voltammetry highly selective masking Co^2+determination zinc electrolyte
在线阅读 下载PDF
Autonomous orbit determination for the probe around small body
15
作者 黄翔宇 崔祜涛 +1 位作者 崔平远 栾恩杰 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2004年第3期327-332,共6页
The algorithm of autonomous orbit determination for the probe around small body is studied. In the algorithm, first, the observed images of the body are compared with its pre-computed model of the body to obtain the l... The algorithm of autonomous orbit determination for the probe around small body is studied. In the algorithm, first, the observed images of the body are compared with its pre-computed model of the body to obtain the location of the limb features of the body in the inertial coordinate. Second, the information of the images and features in utilized to obtain the position of the probe using the Levenberg-Marquardt algorithm. The position is then input to an extended Kalman filter which determines the real time orbit of the probe. Finally, considering the effective of the irregular small body shape perturbation and the small body model parameter error on the orbit determination precise, the procedure of autonomous orbit determination is validated using digital simulation. 展开更多
关键词 autonomous orbit determination probe around small body Levenberg-Marquardt algorithm extended Kalman filter
在线阅读 下载PDF
Determination of Thioglucoside in Cabbage by Using the Ultraviolet-visible Light Spectrophotometer
16
作者 WANGJing WANGQing 《Journal of Northeast Agricultural University(English Edition)》 CAS 2000年第2期149-157,共9页
The ultraviolet-visible light spectrophotometer method was adopted to determine thioglucoside in cabbage with the seeds.Individual plant of cabbage was used as test materials,palladium chloride as complexing agent and... The ultraviolet-visible light spectrophotometer method was adopted to determine thioglucoside in cabbage with the seeds.Individual plant of cabbage was used as test materials,palladium chloride as complexing agent and sodium cellulose glycolate as dispersing agent.The results showed that palladiumd thioglucoside method could be taken as a quick,easy and precise quantitative analysis method to determine thioglucoside in cabbage. 展开更多
关键词 Ultraviolet visible light spectrophotometer method CABBAGE thioglucoside determination method
在线阅读 下载PDF
High-Precision Direct Determination of the ^(87)Sr/^(86)Sr Isotope Ratio of Bottled Sr-Rich Natural Mineral Drinking Water Using MC-ICP-MS
17
作者 YANG Yue-heng,WU Fu-yuan,XIE Lie-wen YANG Jin-hui,ZHANG Yan-bin(State Key Laboratory of Lithospheric Evolution,Institute of Geology and Geophysics,Chinese Academy of Sciences,Beijing,100029,China) 《矿物学报》 CAS CSCD 北大核心 2011年第S1期1025-1025,共1页
Strontium has four naturally occurring stable isotopes,84Sr,86Sr,87Sr,and 88Sr,with abundances of 0.56,9.87,approximately 7.04,and 82.53 atomic %,respectively.The 87Sr/86Sr isotope ratio is variable due to the additio... Strontium has four naturally occurring stable isotopes,84Sr,86Sr,87Sr,and 88Sr,with abundances of 0.56,9.87,approximately 7.04,and 82.53 atomic %,respectively.The 87Sr/86Sr isotope ratio is variable due to the addition of radiogenic 87Sr produced by the beta decay of 87Rb with a half-life of 4.88 ± 0.05 Ga.Thus, 展开更多
关键词 Sr Isotope Ratio of Bottled Sr-Rich Natural Mineral Drinking Water Using MC-ICP-MS High-Precision Direct determination of the TIMS ICP MC
在线阅读 下载PDF
ON THE PROBLEM OF UNIQUENESS AND DETERMINATION OF ALGEBRAIC FUNCTIONS
18
作者 Yu Junyang(Institute of Mathematics, Academia Sinica) 《中国科学院研究生院学报》 CAS CSCD 1991年第1期10-22,共13页
This paper gives the unicity theorem of algebraic functions and further inquires into the problem of determination of algebraic functions.
关键词 unigueness determination ALGEBRAIC FUNCTIONS
在线阅读 下载PDF
液相色谱-质谱联用对复杂食品基质中407种多农药残留量的测定 被引量:12
19
作者 薄涛 詹顺安 +3 位作者 胡培斌 王颖 张之旭 李平 《分析测试学报》 CAS CSCD 北大核心 2008年第S1期190-192,共3页
A new method was developed for determination of 407 pesticide residues in complex matrix by using LC-MS with triple quadrupole(QQQ).Comparing with regular method,the method has high sensitivity and repeativity,and was... A new method was developed for determination of 407 pesticide residues in complex matrix by using LC-MS with triple quadrupole(QQQ).Comparing with regular method,the method has high sensitivity and repeativity,and was applied for the determination of peticide in real sample with satisfactory results. 展开更多
关键词 LC-MS PESTICIDES RESIDUES determination
在线阅读 下载PDF
高分辨电感耦合等离子体质谱法测定煤质样品中49种痕量元素 被引量:4
20
作者 张彦辉 武朝晖 +1 位作者 郭虹 薛丽丽 《质谱学报》 EI CAS CSCD 2005年第z1期33-34,共2页
Various trace elements, especially potential toxic trace elements such as As, Cd, Cr, Cu, Hg, Pb, Ni, Se, Tl, Zn, would be concentrated in processing of coal. Determination of these elements in coal is very important ... Various trace elements, especially potential toxic trace elements such as As, Cd, Cr, Cu, Hg, Pb, Ni, Se, Tl, Zn, would be concentrated in processing of coal. Determination of these elements in coal is very important for identification of coal quality. A method is developed for determination of 49 trace elements in coal by high resolution inductively coupled plasma mass spectrometry (HR-ICPMS). Microwave acid digestion and low-temperature airproof acid digestion for sample preparation were investigated. It is shown that the low-temperature airproof acid digestion method is of lower blank, and more suitalbe for the coal sample preparation. The on-line internal standard (Rh) sample introduction is applied to compensate matrix effects in measurement by ICPMS. The method gives low detection limits (0.002-1.60 μg/g) and better relative standard deviations (0.60%-4.78%) for the determined 49 elements in coal. 展开更多
关键词 TRACE ELEMENTS COAL HR-ICPMS determination
在线阅读 下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部