Angles-only relative orbit determination for space non-cooperative targets based on passive sensor is subject to weakly observable problem of the relative state between two spacecraft. Previously, the evidence for ang...Angles-only relative orbit determination for space non-cooperative targets based on passive sensor is subject to weakly observable problem of the relative state between two spacecraft. Previously, the evidence for angles-only observability was found by using cylindrical dynamics, however, the solution of orbit determination is still not provided. This study develops a relative orbit determination algorithm with the cylindrical dynamics based on differential evolution. Firstly, the relative motion dynamics and line-of-sight measurement model for nearcircular orbit are established in cylindrical coordinate system.Secondly, the observability is qualitatively analyzed by using the dynamics and measurement model where the unobservable geometry is found. Then, the angles-only relative orbit determination problem is modeled into an optimal searching frame and an improved differential evolution algorithm is introduced to solve the problem. Finally, the proposed algorithm is verified and tested by a set of numerical simulations in the context of highEarth and low-Earth cases. The results show that initial relative orbit determination(IROD) solution with an appropriate accuracy in a relative short span is achieved, which can be used to initialize the navigation filter.展开更多
This work introduces a novel method for measuring thin film thickness,employing a multi-wavelength method that significantly reduces the need for broad-spectrum data.Unlike traditional techniques that require sev⁃eral...This work introduces a novel method for measuring thin film thickness,employing a multi-wavelength method that significantly reduces the need for broad-spectrum data.Unlike traditional techniques that require sev⁃eral hundred spectral data points,the multi-wavelength method achieves precise thickness measurements with data from only 10 wavelengths.This innovation not only simplifies the process of spectral measurement analysis but also enables accurate real-time thickness measurement on industrial coating production lines.The method effectively reconstructs and fits the visible spectrum(400-800 nm)using a minimal amount of data,while maintaining measurement error within 7.1%.This advancement lays the foundation for more practical and efficient thin film thickness determination techniques in various industrial applications.展开更多
Based on the field destructive test of six rock-socketed piles with shallow overburden,three prediction models are used to quantitatively analyze and predict the intact load−displacement curve.The predicted values of ...Based on the field destructive test of six rock-socketed piles with shallow overburden,three prediction models are used to quantitatively analyze and predict the intact load−displacement curve.The predicted values of ultimate uplift capacity were further determined by four methods(displacement controlling method(DCM),reduction coefficient method(RCM),maximum curvature method(MCM),and critical stiffness method(CSM))and compared with the measured value.Through the analysis of the relationship between the change rate of pullout stiffness and displacement,a method used to determine the ultimate uplift capacity via non-intact load−displacement curve was proposed.The results show that the predicted value determined by DCM is more conservative,while the predicted value determined by MCM is larger than the measured value.This suggests that RCM and CSM in engineering applications can be preferentially applied.Moreover,the development law of the change rate of pullout stiffness with displacement agrees well with the attenuation form of power function.The theoretical predicted results of ultimate uplift capacity based on the change rate of pullout stiffness will not be affected by the integrity of the curve.The method is simple and applicable for the piles that are not loaded to failure state,and thus provides new insights into ultimate uplift capacity determination of test piles.展开更多
In view of the problem that the current single-antenna GPS attitude determination system can only determine the body attitude when the sideslip angle is zero and the multiantenna GPS/SINS integrated navigation system ...In view of the problem that the current single-antenna GPS attitude determination system can only determine the body attitude when the sideslip angle is zero and the multiantenna GPS/SINS integrated navigation system is of large volume, high cost, and complex structure, this approach is presented to determine the attitude based on vector space with single-antenna GPS and accelerometers in the micro inertial measurement unit (MIMU). It can provide real-time and accurate attitude information. Subsequently, the single-antenna GPS/SINS integrated navigation system is designed based on the combination of position, velocity, and attitude. Finally the semi- physical simulations of single-antenna GPS attitude determination system and single-antenna GPS/SINS integrated navigation system are carried out. The simulation results, based on measured data, show that the single-antenna GPS/SINS system can provide more accurate navigation information compared to the GPS/SINS system, based on the combination of position and velocity. Furthermore, the single-antenna GPS/SINS system is characteristic of lower cost and simpler structure. It provides the basis for the application of a single-antenna GPS/SINS integrated navigation system in a micro aerial vehicle (MAV).展开更多
Reagents are optimized for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in zinc sulfate solution, which contains an extremely large excess of Zn^(2+). First, the reagents and their d...Reagents are optimized for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in zinc sulfate solution, which contains an extremely large excess of Zn^(2+). First, the reagents and their doses for the experiment are selected according to the characteristics of the zinc sulfate solution. Then, the reagent doses are optimized by analyzing the influence of reagent dose on the polarographic parameters(i.e. half-wave potential E_(1/2) and limiting diffusion current I_p). Finally, the optimization results are verified by simultaneously determining trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in the presence of an extremely large excess of Zn^(2+). The determination results indicate that the optimized reagents exhibit wide linearity, low detection limits, high accuracy and good precision for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in the presence of an extremely large excess of Zn^(2+).展开更多
The contents of Cr, Cu, Ni, As, Cd and Pb in coal fly ash were determined by a high resolution inductively coupled plasma mass spectrometry method. The sample digestions were performed in closed microwave vessels with...The contents of Cr, Cu, Ni, As, Cd and Pb in coal fly ash were determined by a high resolution inductively coupled plasma mass spectrometry method. The sample digestions were performed in closed microwave vessels with HNO3, HClO4 and FIE The optimum conditions for the determination were obtained. The applicability of the proposed method was validated by the analysis of coal fly ash reference material (NIST SRM 1633a). The results show that most of the spectral interferences can be avoided by measuring in the high resolution mode (maximum mass resolution R=9 000). The detection limit is from 0.05 to 0.21 μg/g, and the precision is fine with relative standard deviation less than 4.3%.展开更多
A polarographic catalytic wave of cobalt in the substrate solution (pH=8.5) of diacetyldioxime potassium pyrophosphate ammonium chloride was studied and a new method for rapid determination of trace cobalt in complex ...A polarographic catalytic wave of cobalt in the substrate solution (pH=8.5) of diacetyldioxime potassium pyrophosphate ammonium chloride was studied and a new method for rapid determination of trace cobalt in complex zinc electrolyte solution was developed. The results show that there is a very sensitive catalytic wave of cobalt at 1.23 V. At least three hundred thousand fold Zn 2+ does not affect the determination of cobalt. The method is easy to operate and rapid, and when the signal to noise rate equals 2, the detection limit is 6×10 -9 mol·L -1 . A good linear relationship exists between the concentration of cobalt within 0.001 ~3.0 μg·mL -1 and the peak current. The method has successfully been used in the determination of trace cobalt in complex solution of the workshop for electrolyzing zinc.展开更多
A new error analysis method is presented via genetic algorithms for high precise heading determination model based on two total positioning stations (TPSs). The method has the ability to search all possible solution...A new error analysis method is presented via genetic algorithms for high precise heading determination model based on two total positioning stations (TPSs). The method has the ability to search all possible solution space by the genetic operators of elitist model and restriction. The result of analyzing the error of this model shows that the accuracy of this model is precise enough to meet the need of calibration for navigation systems on ship, and the search space is only 0. 03% of the total search space, and the precision of heading determination is 4" in a general dock.展开更多
The conventional direct position determination(DPD) algorithm processes all received signals on a single sensor.When sensors have limited computational capabilities or energy storage,it is desirable to distribute th...The conventional direct position determination(DPD) algorithm processes all received signals on a single sensor.When sensors have limited computational capabilities or energy storage,it is desirable to distribute the computation among other sensors.A distributed adaptive DPD(DADPD)algorithm based on diffusion framework is proposed for emitter localization.Unlike the corresponding centralized adaptive DPD(CADPD) algorithm,all but one sensor in the proposed algorithm participate in processing the received signals and estimating the common emitter position,respectively.The computational load and energy consumption on a single sensor in the CADPD algorithm is distributed among other computing sensors in a balanced manner.Exactly the same iterative localization algorithm is carried out in each computing sensor,respectively,and the algorithm in each computing sensor exhibits quite similar convergence behavior.The difference of the localization and tracking performance between the proposed distributed algorithm and the corresponding CADPD algorithm is negligible through simulation evaluations.展开更多
A new process of separating sulfur with different valance from polysulfide mixtures was developed. Sulfide, sulfite and sulfur were separated by adding acetic acid in one step. The polysulfide mixture, sulfite solutio...A new process of separating sulfur with different valance from polysulfide mixtures was developed. Sulfide, sulfite and sulfur were separated by adding acetic acid in one step. The polysulfide mixture, sulfite solution and sulfur were oxidized to sulfate by hydrogen peroxide. The products were measured by X ray Fluorescence Spectrometer(XRF) using filter method preparative specimen. The measurement needs only one set of standard sample.The effects of temperature and pH values on the separation were discussed. The results show that the recoveries range from 98.0% to 101.3% of sulfidic sulfur S( II), 97.0% to 103.0% for sulfite S(IV) and 98.4% to 100.4% for polysulfidic sulfur S(0).展开更多
The construction principle of the system for determination of xanthate concentration,which consists of an Ionselective electrode(ISE) and a microprocessor based SDI analyzer,was described in the paper.The performances...The construction principle of the system for determination of xanthate concentration,which consists of an Ionselective electrode(ISE) and a microprocessor based SDI analyzer,was described in the paper.The performances of the developed system were discussed in details.The results both detected in solutions and in sulfide mineral flotation system were given; also the results by ultraviolet spectrometry were compared with those by the developed system.展开更多
Fingerprints of two varieties of rice and their mixtures were investigated by a nonlinear chemical reaction system consisting of rice components,sodium bromate,manganese sulfate,sulfuric acid and acetone.The variety o...Fingerprints of two varieties of rice and their mixtures were investigated by a nonlinear chemical reaction system consisting of rice components,sodium bromate,manganese sulfate,sulfuric acid and acetone.The variety of rice was identified by the visual characteristic of fingerprint and system similarity pattern recognition,and the content of each variety of rice in the mixture was determined by the quantitative information of fingerprint.The results show that nonlinear chemical analysis may be used to exactly identify the variety of pure rice and to accurately determine the content of each variety of rice in the mixture,indicating the method is simple and convenient.展开更多
A new method for the determination of DNA was developed with azocarmine G(AG) in the presence of cetyltrimethylammonium bromide(CTAB) by the resonance light scattering (RLS) technique. The synthetic samples were deter...A new method for the determination of DNA was developed with azocarmine G(AG) in the presence of cetyltrimethylammonium bromide(CTAB) by the resonance light scattering (RLS) technique. The synthetic samples were determined with satisfactory results, and the reaction mechanism was also studied. The results show that underthe optimum conditions, the weak RLS signal of AG can be enhanced by DNA, which results from the formation of a new ternary complex AG-CTAB-DNA with large size. Moreover, the enhanced RLS intensity at 552 nm is directlyproportional to the concentration of DNA in the range of 01.0 μg/mL for fish sperm DNA (fsDNA) and 01.5 μg/mLfor calf thymus DNA (ctDNA). Based on this, a new assay of DNA can be established. The detection limits (3σ) are 2.1 ng/mL for fsDNA and 2.2 ng/mL for ctDNA, respectively.展开更多
We report herein a highly selective method for directly determining the trace Co^2+in highly concentrated zinc electrolyte.This novel method is based on a second derivative wave of catalytic adsorptive polarography ge...We report herein a highly selective method for directly determining the trace Co^2+in highly concentrated zinc electrolyte.This novel method is based on a second derivative wave of catalytic adsorptive polarography generated by complexing Co^2+with dimethylglyoxime and nitrite onto a dropping mercury electrode.By employing a medium with NH3-NH4Cl buffer,DMG and NaNO2 during determining the trace Co^2+,any interferences of highly concentrated Zn^2+and other coexisting metal ions in the electrolyte are completely eliminated due to the selective masking effect of EDTA.When the concentration of Co^2+is within 1.0×10^–10–3.2×10^–7 mol/L range,it shows a good linear relationship with the current peak.Detection limit is 1.0×10^–11 mol/L,and RSD≤2.7%for six successive assays.We have compared the efficiency of the current method to that obtained by cobalt nitroso-R-salt spectrophotometry,and the absolute values of relative deviations are≤4.2%.The method developed and described herein has been successfully employed in determining the trace Co2+in actual zinc electrolyte.展开更多
The algorithm of autonomous orbit determination for the probe around small body is studied. In the algorithm, first, the observed images of the body are compared with its pre-computed model of the body to obtain the l...The algorithm of autonomous orbit determination for the probe around small body is studied. In the algorithm, first, the observed images of the body are compared with its pre-computed model of the body to obtain the location of the limb features of the body in the inertial coordinate. Second, the information of the images and features in utilized to obtain the position of the probe using the Levenberg-Marquardt algorithm. The position is then input to an extended Kalman filter which determines the real time orbit of the probe. Finally, considering the effective of the irregular small body shape perturbation and the small body model parameter error on the orbit determination precise, the procedure of autonomous orbit determination is validated using digital simulation.展开更多
The ultraviolet-visible light spectrophotometer method was adopted to determine thioglucoside in cabbage with the seeds.Individual plant of cabbage was used as test materials,palladium chloride as complexing agent and...The ultraviolet-visible light spectrophotometer method was adopted to determine thioglucoside in cabbage with the seeds.Individual plant of cabbage was used as test materials,palladium chloride as complexing agent and sodium cellulose glycolate as dispersing agent.The results showed that palladiumd thioglucoside method could be taken as a quick,easy and precise quantitative analysis method to determine thioglucoside in cabbage.展开更多
Strontium has four naturally occurring stable isotopes,84Sr,86Sr,87Sr,and 88Sr,with abundances of 0.56,9.87,approximately 7.04,and 82.53 atomic %,respectively.The 87Sr/86Sr isotope ratio is variable due to the additio...Strontium has four naturally occurring stable isotopes,84Sr,86Sr,87Sr,and 88Sr,with abundances of 0.56,9.87,approximately 7.04,and 82.53 atomic %,respectively.The 87Sr/86Sr isotope ratio is variable due to the addition of radiogenic 87Sr produced by the beta decay of 87Rb with a half-life of 4.88 ± 0.05 Ga.Thus,展开更多
A new method was developed for determination of 407 pesticide residues in complex matrix by using LC-MS with triple quadrupole(QQQ).Comparing with regular method,the method has high sensitivity and repeativity,and was...A new method was developed for determination of 407 pesticide residues in complex matrix by using LC-MS with triple quadrupole(QQQ).Comparing with regular method,the method has high sensitivity and repeativity,and was applied for the determination of peticide in real sample with satisfactory results.展开更多
Various trace elements, especially potential toxic trace elements such as As, Cd, Cr, Cu, Hg, Pb, Ni, Se, Tl, Zn, would be concentrated in processing of coal. Determination of these elements in coal is very important ...Various trace elements, especially potential toxic trace elements such as As, Cd, Cr, Cu, Hg, Pb, Ni, Se, Tl, Zn, would be concentrated in processing of coal. Determination of these elements in coal is very important for identification of coal quality. A method is developed for determination of 49 trace elements in coal by high resolution inductively coupled plasma mass spectrometry (HR-ICPMS). Microwave acid digestion and low-temperature airproof acid digestion for sample preparation were investigated. It is shown that the low-temperature airproof acid digestion method is of lower blank, and more suitalbe for the coal sample preparation. The on-line internal standard (Rh) sample introduction is applied to compensate matrix effects in measurement by ICPMS. The method gives low detection limits (0.002-1.60 μg/g) and better relative standard deviations (0.60%-4.78%) for the determined 49 elements in coal.展开更多
基金supported by the National Natural Science Foundation of China (12272168)the Foundation of Science and Technology on Space Intelligent Control Laboratory (HTKJ2023KL502015)。
文摘Angles-only relative orbit determination for space non-cooperative targets based on passive sensor is subject to weakly observable problem of the relative state between two spacecraft. Previously, the evidence for angles-only observability was found by using cylindrical dynamics, however, the solution of orbit determination is still not provided. This study develops a relative orbit determination algorithm with the cylindrical dynamics based on differential evolution. Firstly, the relative motion dynamics and line-of-sight measurement model for nearcircular orbit are established in cylindrical coordinate system.Secondly, the observability is qualitatively analyzed by using the dynamics and measurement model where the unobservable geometry is found. Then, the angles-only relative orbit determination problem is modeled into an optimal searching frame and an improved differential evolution algorithm is introduced to solve the problem. Finally, the proposed algorithm is verified and tested by a set of numerical simulations in the context of highEarth and low-Earth cases. The results show that initial relative orbit determination(IROD) solution with an appropriate accuracy in a relative short span is achieved, which can be used to initialize the navigation filter.
基金Supported by National Key R&D Program of China(2021YFA0715500)National Natural Science Foundation of China(NSFC)(12227901)+2 种基金Strategic Priority Research Program(B)of the Chinese Academy of Sciences(XDB0580000)Shanghai Municipal Science and Technology Major Project(2019SHZDZX01)Chinese Academy of Sciences President's International Fellowship Initiative(2021PT0007).
文摘This work introduces a novel method for measuring thin film thickness,employing a multi-wavelength method that significantly reduces the need for broad-spectrum data.Unlike traditional techniques that require sev⁃eral hundred spectral data points,the multi-wavelength method achieves precise thickness measurements with data from only 10 wavelengths.This innovation not only simplifies the process of spectral measurement analysis but also enables accurate real-time thickness measurement on industrial coating production lines.The method effectively reconstructs and fits the visible spectrum(400-800 nm)using a minimal amount of data,while maintaining measurement error within 7.1%.This advancement lays the foundation for more practical and efficient thin film thickness determination techniques in various industrial applications.
基金Project(2016YFC0802203)supported by the National Key R&D Program of ChinaProject(2013G001-A-2)supported by the Science and Technology Research and Development Program of China Railway CorporationProject(SKLGDUEK2011)supported by the State Key Laboratory for GeoMechanics and Deep Underground Engineering,China University of Mining&Technology。
文摘Based on the field destructive test of six rock-socketed piles with shallow overburden,three prediction models are used to quantitatively analyze and predict the intact load−displacement curve.The predicted values of ultimate uplift capacity were further determined by four methods(displacement controlling method(DCM),reduction coefficient method(RCM),maximum curvature method(MCM),and critical stiffness method(CSM))and compared with the measured value.Through the analysis of the relationship between the change rate of pullout stiffness and displacement,a method used to determine the ultimate uplift capacity via non-intact load−displacement curve was proposed.The results show that the predicted value determined by DCM is more conservative,while the predicted value determined by MCM is larger than the measured value.This suggests that RCM and CSM in engineering applications can be preferentially applied.Moreover,the development law of the change rate of pullout stiffness with displacement agrees well with the attenuation form of power function.The theoretical predicted results of ultimate uplift capacity based on the change rate of pullout stiffness will not be affected by the integrity of the curve.The method is simple and applicable for the piles that are not loaded to failure state,and thus provides new insights into ultimate uplift capacity determination of test piles.
基金the Astronautic Technology Foundation (HTZC0405)
文摘In view of the problem that the current single-antenna GPS attitude determination system can only determine the body attitude when the sideslip angle is zero and the multiantenna GPS/SINS integrated navigation system is of large volume, high cost, and complex structure, this approach is presented to determine the attitude based on vector space with single-antenna GPS and accelerometers in the micro inertial measurement unit (MIMU). It can provide real-time and accurate attitude information. Subsequently, the single-antenna GPS/SINS integrated navigation system is designed based on the combination of position, velocity, and attitude. Finally the semi- physical simulations of single-antenna GPS attitude determination system and single-antenna GPS/SINS integrated navigation system are carried out. The simulation results, based on measured data, show that the single-antenna GPS/SINS system can provide more accurate navigation information compared to the GPS/SINS system, based on the combination of position and velocity. Furthermore, the single-antenna GPS/SINS system is characteristic of lower cost and simpler structure. It provides the basis for the application of a single-antenna GPS/SINS integrated navigation system in a micro aerial vehicle (MAV).
基金Projects(61533021,61321003,61273185)supported by the National Natural Science Foundation of ChinaProject(2015CX007)supported by the Innovation-driven Plan in Central South University,ChinaProject(13JJ8003)supported by the Joint Fund of Hunan Provincial Natural Science Foundation of China
文摘Reagents are optimized for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in zinc sulfate solution, which contains an extremely large excess of Zn^(2+). First, the reagents and their doses for the experiment are selected according to the characteristics of the zinc sulfate solution. Then, the reagent doses are optimized by analyzing the influence of reagent dose on the polarographic parameters(i.e. half-wave potential E_(1/2) and limiting diffusion current I_p). Finally, the optimization results are verified by simultaneously determining trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in the presence of an extremely large excess of Zn^(2+). The determination results indicate that the optimized reagents exhibit wide linearity, low detection limits, high accuracy and good precision for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in the presence of an extremely large excess of Zn^(2+).
基金Project (04JJ40016) supported by the Natural Science Foundation of Hunan Province, China
文摘The contents of Cr, Cu, Ni, As, Cd and Pb in coal fly ash were determined by a high resolution inductively coupled plasma mass spectrometry method. The sample digestions were performed in closed microwave vessels with HNO3, HClO4 and FIE The optimum conditions for the determination were obtained. The applicability of the proposed method was validated by the analysis of coal fly ash reference material (NIST SRM 1633a). The results show that most of the spectral interferences can be avoided by measuring in the high resolution mode (maximum mass resolution R=9 000). The detection limit is from 0.05 to 0.21 μg/g, and the precision is fine with relative standard deviation less than 4.3%.
基金The Science and Research Foundation of Education Commission of Hunan Province!(No.98C118)
文摘A polarographic catalytic wave of cobalt in the substrate solution (pH=8.5) of diacetyldioxime potassium pyrophosphate ammonium chloride was studied and a new method for rapid determination of trace cobalt in complex zinc electrolyte solution was developed. The results show that there is a very sensitive catalytic wave of cobalt at 1.23 V. At least three hundred thousand fold Zn 2+ does not affect the determination of cobalt. The method is easy to operate and rapid, and when the signal to noise rate equals 2, the detection limit is 6×10 -9 mol·L -1 . A good linear relationship exists between the concentration of cobalt within 0.001 ~3.0 μg·mL -1 and the peak current. The method has successfully been used in the determination of trace cobalt in complex solution of the workshop for electrolyzing zinc.
文摘A new error analysis method is presented via genetic algorithms for high precise heading determination model based on two total positioning stations (TPSs). The method has the ability to search all possible solution space by the genetic operators of elitist model and restriction. The result of analyzing the error of this model shows that the accuracy of this model is precise enough to meet the need of calibration for navigation systems on ship, and the search space is only 0. 03% of the total search space, and the precision of heading determination is 4" in a general dock.
基金supported by the National Natural Science Foundation of China(61101173)
文摘The conventional direct position determination(DPD) algorithm processes all received signals on a single sensor.When sensors have limited computational capabilities or energy storage,it is desirable to distribute the computation among other sensors.A distributed adaptive DPD(DADPD)algorithm based on diffusion framework is proposed for emitter localization.Unlike the corresponding centralized adaptive DPD(CADPD) algorithm,all but one sensor in the proposed algorithm participate in processing the received signals and estimating the common emitter position,respectively.The computational load and energy consumption on a single sensor in the CADPD algorithm is distributed among other computing sensors in a balanced manner.Exactly the same iterative localization algorithm is carried out in each computing sensor,respectively,and the algorithm in each computing sensor exhibits quite similar convergence behavior.The difference of the localization and tracking performance between the proposed distributed algorithm and the corresponding CADPD algorithm is negligible through simulation evaluations.
文摘A new process of separating sulfur with different valance from polysulfide mixtures was developed. Sulfide, sulfite and sulfur were separated by adding acetic acid in one step. The polysulfide mixture, sulfite solution and sulfur were oxidized to sulfate by hydrogen peroxide. The products were measured by X ray Fluorescence Spectrometer(XRF) using filter method preparative specimen. The measurement needs only one set of standard sample.The effects of temperature and pH values on the separation were discussed. The results show that the recoveries range from 98.0% to 101.3% of sulfidic sulfur S( II), 97.0% to 103.0% for sulfite S(IV) and 98.4% to 100.4% for polysulfidic sulfur S(0).
文摘The construction principle of the system for determination of xanthate concentration,which consists of an Ionselective electrode(ISE) and a microprocessor based SDI analyzer,was described in the paper.The performances of the developed system were discussed in details.The results both detected in solutions and in sulfide mineral flotation system were given; also the results by ultraviolet spectrometry were compared with those by the developed system.
基金Project(61533021) supported by the National Natural Science Foundation of China
文摘Fingerprints of two varieties of rice and their mixtures were investigated by a nonlinear chemical reaction system consisting of rice components,sodium bromate,manganese sulfate,sulfuric acid and acetone.The variety of rice was identified by the visual characteristic of fingerprint and system similarity pattern recognition,and the content of each variety of rice in the mixture was determined by the quantitative information of fingerprint.The results show that nonlinear chemical analysis may be used to exactly identify the variety of pure rice and to accurately determine the content of each variety of rice in the mixture,indicating the method is simple and convenient.
文摘A new method for the determination of DNA was developed with azocarmine G(AG) in the presence of cetyltrimethylammonium bromide(CTAB) by the resonance light scattering (RLS) technique. The synthetic samples were determined with satisfactory results, and the reaction mechanism was also studied. The results show that underthe optimum conditions, the weak RLS signal of AG can be enhanced by DNA, which results from the formation of a new ternary complex AG-CTAB-DNA with large size. Moreover, the enhanced RLS intensity at 552 nm is directlyproportional to the concentration of DNA in the range of 01.0 μg/mL for fish sperm DNA (fsDNA) and 01.5 μg/mLfor calf thymus DNA (ctDNA). Based on this, a new assay of DNA can be established. The detection limits (3σ) are 2.1 ng/mL for fsDNA and 2.2 ng/mL for ctDNA, respectively.
基金Projects(61533021,61773403)supported by the National Natural Science Foundation of China
文摘We report herein a highly selective method for directly determining the trace Co^2+in highly concentrated zinc electrolyte.This novel method is based on a second derivative wave of catalytic adsorptive polarography generated by complexing Co^2+with dimethylglyoxime and nitrite onto a dropping mercury electrode.By employing a medium with NH3-NH4Cl buffer,DMG and NaNO2 during determining the trace Co^2+,any interferences of highly concentrated Zn^2+and other coexisting metal ions in the electrolyte are completely eliminated due to the selective masking effect of EDTA.When the concentration of Co^2+is within 1.0×10^–10–3.2×10^–7 mol/L range,it shows a good linear relationship with the current peak.Detection limit is 1.0×10^–11 mol/L,and RSD≤2.7%for six successive assays.We have compared the efficiency of the current method to that obtained by cobalt nitroso-R-salt spectrophotometry,and the absolute values of relative deviations are≤4.2%.The method developed and described herein has been successfully employed in determining the trace Co2+in actual zinc electrolyte.
基金This project was supported by the 15th Plan National Defence Science & Tehnology and Civil Space Previous Study Project.
文摘The algorithm of autonomous orbit determination for the probe around small body is studied. In the algorithm, first, the observed images of the body are compared with its pre-computed model of the body to obtain the location of the limb features of the body in the inertial coordinate. Second, the information of the images and features in utilized to obtain the position of the probe using the Levenberg-Marquardt algorithm. The position is then input to an extended Kalman filter which determines the real time orbit of the probe. Finally, considering the effective of the irregular small body shape perturbation and the small body model parameter error on the orbit determination precise, the procedure of autonomous orbit determination is validated using digital simulation.
文摘The ultraviolet-visible light spectrophotometer method was adopted to determine thioglucoside in cabbage with the seeds.Individual plant of cabbage was used as test materials,palladium chloride as complexing agent and sodium cellulose glycolate as dispersing agent.The results showed that palladiumd thioglucoside method could be taken as a quick,easy and precise quantitative analysis method to determine thioglucoside in cabbage.
文摘Strontium has four naturally occurring stable isotopes,84Sr,86Sr,87Sr,and 88Sr,with abundances of 0.56,9.87,approximately 7.04,and 82.53 atomic %,respectively.The 87Sr/86Sr isotope ratio is variable due to the addition of radiogenic 87Sr produced by the beta decay of 87Rb with a half-life of 4.88 ± 0.05 Ga.Thus,
文摘A new method was developed for determination of 407 pesticide residues in complex matrix by using LC-MS with triple quadrupole(QQQ).Comparing with regular method,the method has high sensitivity and repeativity,and was applied for the determination of peticide in real sample with satisfactory results.
文摘Various trace elements, especially potential toxic trace elements such as As, Cd, Cr, Cu, Hg, Pb, Ni, Se, Tl, Zn, would be concentrated in processing of coal. Determination of these elements in coal is very important for identification of coal quality. A method is developed for determination of 49 trace elements in coal by high resolution inductively coupled plasma mass spectrometry (HR-ICPMS). Microwave acid digestion and low-temperature airproof acid digestion for sample preparation were investigated. It is shown that the low-temperature airproof acid digestion method is of lower blank, and more suitalbe for the coal sample preparation. The on-line internal standard (Rh) sample introduction is applied to compensate matrix effects in measurement by ICPMS. The method gives low detection limits (0.002-1.60 μg/g) and better relative standard deviations (0.60%-4.78%) for the determined 49 elements in coal.