期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Influence of blast furnace top gas composition and dust on HCl removal with low temperature Ca-based dechlorination agent 被引量:3
1
作者 TENG Ai-jun HU Bin-sheng +1 位作者 GUI Yong-liang XUE Xiang-xin 《Journal of Central South University》 SCIE EI CAS CSCD 2018年第8期1920-1927,共8页
Using fixed-bed reaction method and changing the gas composition and dust content,the influence of blast furnace top gas composition and dust on HCl removal with low temperature Ca-based antichlor was studied.It was f... Using fixed-bed reaction method and changing the gas composition and dust content,the influence of blast furnace top gas composition and dust on HCl removal with low temperature Ca-based antichlor was studied.It was found that,when the content of CO2 in blast furnace top gas increased,the dechlorination efficiency was getting worse obviously;when the contents of CO and N2 increased,the dechlorination efficiency was getting better to a certain extent;when the content of H2 changed,the dechlorination efficiency got no significant change;as the content of dust increased,the dechlorination efficiency got better obviously when the content was less than 15 g/m3,but it would be got worse quickly when the content was more than 20 g/m3,and the best content was 15–20 g/m3;the suitable site of the process of dechlorination was after gravity dust collector and before bag dust collector. 展开更多
关键词 blast furnace top gas HCl gas dechlorination breakthrough time penetration chlorine capacity
在线阅读 下载PDF
Dechlorination of zinc dross by microwave roasting
2
作者 魏亚乾 彭金辉 +4 位作者 张利波 巨少华 夏仡 郑勤 王亚健 《Journal of Central South University》 SCIE EI CAS 2014年第7期2627-2632,共6页
Traditional treatments of zinc dross have many disadvantages,such as complicated recovering process and serious environmental pollution.In this work,a new process of chlorine removal from zinc dross by microwave was p... Traditional treatments of zinc dross have many disadvantages,such as complicated recovering process and serious environmental pollution.In this work,a new process of chlorine removal from zinc dross by microwave was proposed for solving problem of recycling the zinc dross.With better ability of absorbing the microwave than zinc oxide,the main material in zinc dross,chlorides,can be heated and evaporated rapidly during microwave roasting.Various parameters including roasting temperature,duration time and stirring speed were optimized.The microstructure of roasted materials was characterized by X-ray diffraction(XRD) and scanning electron microscope(SEM).The content of the chloride was analyzed by the method of chlorine ion selective electrode.The experiments indicate that the best duration time is 60 min with a stirring speed of 15 r/min during the microwave roasting process.The dechlorination rate reaches peak value of 88% at 700 ℃.The chlorine is removed as HCl gas when water vapor is used as activating agent,which means that it can be recovered into hydrochloride acid. 展开更多
关键词 zinc dross microwave roasting dechlorination resources recovery
在线阅读 下载PDF
Optimization of Fenton pretreatment for 2-chlorophenol solution 被引量:1
3
作者 贺仲兵 刘云国 肖玉 《Journal of Central South University》 SCIE EI CAS 2013年第10期2791-2795,共5页
Fenton oxidation was used as the pretreatment of 2-chlorophenol wastewater with the objective of dechlorination, as it was considered that after breakage of aryl—Cl bond, the generated intermediates may be easily bio... Fenton oxidation was used as the pretreatment of 2-chlorophenol wastewater with the objective of dechlorination, as it was considered that after breakage of aryl—Cl bond, the generated intermediates may be easily biodegraded. Hence, the optimization of pH and the low Fenton reagent doses for dechlorination was investigated. More than 99% dechlorination is obtained at the optimal pH 4 and the Fenton reagent doses of 86 mmol/L H2 O2 and 2.87 mmol/L Fe2+. The corresponding 2-chlorophenol is degraded completely, 80.02% COD is also removed, and the biodegradability, evaluated in terms of the BOD5 /COD ratio, is increased up to 0.41. To test the effect of this pretreatment, the pretreated 2-chlorophenol wastewater was fed to a sequencing batch reactor(SBR). The results show that complete mineralization is achieved. It is demonstrated that, for the treatment of recalcitrant compounds like 2-chlorophenol, the Fenton pretreatment could be quite effective and economical for enhancing the biodegradability in a Fenton-biological coupled system. 展开更多
关键词 2-CHLOROPHENOL Fenton-biological coupled system dechlorination sequencing BATCH reactor(SBR) BIODEGRADABILITY
在线阅读 下载PDF
STUDY ON THE PYROLYSIS AND RECYCLING OF PVC WASTE AS AN ENERGY SOURCE 被引量:1
4
作者 Ma Shibai, Yin Jianjun, Lu Jun and Gao Jinsheng (East China University of Science and Technology Shanghai 200237) 《化工学报》 EI CAS CSCD 北大核心 2000年第S1期199-202,共4页
The pyrolysis dechlorination of PVC (polyvinyl chloride) has been carried out by batch operation under atmospheric pressure. The kinetics involved in the PVC thermal decomposition was studied by using thermogravimetri... The pyrolysis dechlorination of PVC (polyvinyl chloride) has been carried out by batch operation under atmospheric pressure. The kinetics involved in the PVC thermal decomposition was studied by using thermogravimetric technique. Several tests were carried out at the heating rate of 5-10℃/min, the yields of products and the distribution of chlorine were also studied. The kinetic parameters such as activation energies, reaction orders and preexponential factors under nitrogen atmosphere were calculated by applying Friedman’s method. The results showed that the PVC thermal degradation is substantially a two-step process. The first step mainly involves dechlorination of the polymers. HCI is the main volatile product and this reaction can be seen as a first-order reaction. A kinetic model for the thermal dechlorination of PVC has been developed. 展开更多
关键词 PVC waste PYROLYSIS dechlorination THERMOGRAVIMETRIC hydrochlorine
在线阅读 下载PDF
Removing chlorine of CuCl residue from zinc hydrometallurgy by microwave roasting
5
作者 卢帅丹 夏仡 +4 位作者 黄昌元 吴国钦 彭金辉 巨少华 张利波 《Journal of Central South University》 SCIE EI CAS 2014年第4期1290-1295,共6页
Most Zn hydrometallurgy factories adopt Cu2SO4 as a dechlorination reagent from zinc solution nowadays, thus much CuCl residue is produced. The existing process of treating this residue is washing with water or sodium... Most Zn hydrometallurgy factories adopt Cu2SO4 as a dechlorination reagent from zinc solution nowadays, thus much CuCl residue is produced. The existing process of treating this residue is washing with water or sodium carbonate solution, which would cause a lot of troubles to water treatment and waste discharge. A method of microwave roasting was adopted for dechlorination of CuCl residue. A 1.5 kW microwave roasting equipment with dust collection and tail gas adsorption systems was set up and applied during the experiment. By investigating the effect of temperature, heat preservation time, moisture content of raw material and grain size of samples on the dechlorination, the optimal experimental condition is obtained. When the samples with 2% moisture and <150 μm grain size are microwave roasted at 400 °C for 2 h, the Cl content turns from 14.27% to 1.35% and the dechlorination rate is as high as 90%, while that with conventional heating is only 60%-80%. The phase change of the roasting process investigated with X-ray diffraction verifies that CuCl in CuCl residue is removed by being transformed into CuO. 展开更多
关键词 microwave roasting zinc hydrometallurgy dechlorination CuCl residue
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部