In this paper a fully parametrized finite element simulation model of the stator bar end is created using the COMSOL Multiphysics.The model allows conducting the comparison of different corona protection structures’d...In this paper a fully parametrized finite element simulation model of the stator bar end is created using the COMSOL Multiphysics.The model allows conducting the comparison of different corona protection structures’design,various materials properties,and finally optimizing the corona protection system.Several samples of SiC based nonlinear conductivity materials for corona protection were fabricated in laboratory and then investigated.The conductivity dependencies on electric field(0.05 to 1 kV/mm)and temperature(20 to 155℃)were measured.By comparing the heat-resistant grades of the corona protection material and the insulating material,the maximum working temperature of the corona protection material corresponds to the heat-resistant grade F of the insulating material.As the temperature increases,the nonlinear characteristics of the corona protection material in the experiment decrease dramatically,reducing the heat-resistant grade of the corona protection material.The decrease in the nonlinear characteristics of the corona protection material at the maximum operating temperature causes the maximum electric field strength at the end of the HV rotating machines end corona protection(ECP)exceeding the corona discharge electric field strength,resulting in corona phenomenon.展开更多
利用解密的美国CORONA卫星影像,在库车冲断褶皱带,开展大面积地表构造调查,获取地区的地表产状.通过建立有理函数模型(rational function model,RFM)校正CORONA影像的全景变形,利用JX-4C数字摄影测量系统进行CORONA影像的立体观测和测量...利用解密的美国CORONA卫星影像,在库车冲断褶皱带,开展大面积地表构造调查,获取地区的地表产状.通过建立有理函数模型(rational function model,RFM)校正CORONA影像的全景变形,利用JX-4C数字摄影测量系统进行CORONA影像的立体观测和测量,确定岩层面的高程值,并采用三点法在MATLAB软件中计算岩层的倾角和走向,获取地表产状.通过和野外实测数据对比,测量误差小于3°,满足了构造定量解析的精度要求.应用获取的构造产状结合二维地震反射资料,根据断层相关褶皱原理定量地提取库车地区褶皱和断层的几何学特征.展开更多
The white-light corona calibrated data with processing level L1 from the LASCO-C2/SOHO instrument, and data from the Wind spacecraft with one-hour and one-minute time resolution on quasi-stationary slow (v between 300...The white-light corona calibrated data with processing level L1 from the LASCO-C2/SOHO instrument, and data from the Wind spacecraft with one-hour and one-minute time resolution on quasi-stationary slow (v between 300-450 km/s at the Earth's orbit) the Solar Wind (SW) parameters in the absence of sporadic SW streams are examined. Within distances from the Sun's center less than R in the range of 20-30 Rs,(Rs, the solar radius), slow wind is known as the streamer belt, and at larger distances it is called the Heliospheric Plasma Sheet (HPS). It is shown that the streamer belt comprises a sequence of pairs of rays. In general, ray brightnesses in each pair can differ, and the magnetic field is oppositely directed in them. The neutral line of the radial magnetic field of the Sun runs along the belt between the rays of each of the pairs.The area in which the streamer belt intersects the ecliptic plane and which lies at the central meridian, will be recorded at the earth's orbit with a time delay of 5-6 days, in the form of one or several peaks with Nmax > 10 cm-3. Furthermore, the simplest density profile of the portion of the HCS has the form of two peaks of a different or identical amplitude . The such a profile is observed in cases where the angle of intersection of the streamer belt with the ecliptic plane near the Sun is sufficiently large, i.e. close to 90°. The two-ray structure of the cross-section of the streamer-belt moves from the Sun to the Earth, it retains not only the angular size of the peaks but also the relative density variations, and the position of the neutral line(sector boundary) in between. At the Earth's orbit the ray structure of the streamer belt provides the source for sharp (i.e. with steep fronts of a duration of a few minutes or shorter) solar wind plasma density peaks (of a duration of several hours) with maximum values Nmax > 10 cm-3.展开更多
Considerable progress for the study of solar corona physics has been achieved by China's space physics community. It involves the theoretical study of coronal process of solar active phenomena, solar wind origin, ...Considerable progress for the study of solar corona physics has been achieved by China's space physics community. It involves the theoretical study of coronal process of solar active phenomena, solar wind origin, acceleration of solar wind and coronal mass ejections, observational and numerical study of these problems and prediction methods of solar eruptive activities (such as flares/CMEs). Here is a brief summary of the progress in this area. Main progress is put upon the following three topics: corona and solar wind, numerical method, prediction method.展开更多
Abnormal voltages such as electrostatic,constant current,and strong electromagnetic signals can erroneously trigger operation of MEMS pyrotechnics and control systems in a fuze,which may result in casualties.This stud...Abnormal voltages such as electrostatic,constant current,and strong electromagnetic signals can erroneously trigger operation of MEMS pyrotechnics and control systems in a fuze,which may result in casualties.This study designs a solid-state micro-scale switch by combining the corona gas discharge theory of asymmetric electric fields and Peek’s Law.The MEMS switch can be transferred from“off”to“on”through the gas breakdown between the corona electrodes.In the model,one of the two electrodes is spherical and the other flat,so a non-uniform electric field is formed around the electrodes.The theoretical work is as follows.First,the relation among the radius of curvature of the spherical electrode,the discharge gap,and the air breakdown voltage is obtained;to meet the low voltage(30-60 V)required to drive the MEMS switch,the radius of curvature of the spherical electrode needs to be 10 e50 mm and the discharge gap between the two electrodes needs to be 9e11 mm.Second,the optimal ratioεis introduced to parameterize the model.Finally,the corona discharge structural parameters are determined by comparing the theoretical and electric field simulation results.The switch is then fabricated via MEMS processing.A hardware test platform is built and the performing chip tested.It is found that when the electrode gap is 9 mm,the electrostatic voltage is at least 37.3 V,with an error of 2.6%between the actual and theoretical air breakdown voltages.When the electrode gap is 11 mm,the electrostatic voltage is at least 42.3 V,with an error of 10.5%between the actual and theoretical air breakdown voltages.Both cases meet the design requirements.展开更多
Corona discharge is being detected by UV imaging detection technology at home and abroad in recent years.This technology is used in the corona tests of conductor bundles in this paper.In order to further research the ...Corona discharge is being detected by UV imaging detection technology at home and abroad in recent years.This technology is used in the corona tests of conductor bundles in this paper.In order to further research the corona characteristic,optimize geometry parameters and diameter of sub-conductor,and increase corona onset voltage of transmission lines,corona tests of three model conductors which are placed inside the outdoor corona cage are conducted.Corona cage could be used to simulate the corona activities on transmission lines under a low voltage and different conditions in an effective and economical way.Photon which was created by UV light as a result of corona discharge on conductors is detected by the UV detection apparatus.The photon number within unit interval,namely photon counting rate is adopted as the parameter of quantifying the intensity of corona discharge.According to the apparent change of photon number,corona onset voltage can be judged.All tests are conducted under almost same atmosphere condition.Using the method,corona onset voltage is acquired.The results indicate that the tests have a good repeatability,in other words,repeating same test twice same result can be aquired.The corona onset voltage can be acquired exactly from the curve of applied voltage vs.photon counting rate.Therefore UV detection apparatus can not only used to find discharge point exactly,but also applied on corona discharge research and live detection for power equipments.The method using in this paper is proved that is a new available method.展开更多
To discuss the modes of dielectric barrier discharge(DBD) between needle-to-plane electrodes in air,DBD is generated and observed on a needle-to-plane device at atmospheric pressure air.Fast images of the DBD are take...To discuss the modes of dielectric barrier discharge(DBD) between needle-to-plane electrodes in air,DBD is generated and observed on a needle-to-plane device at atmospheric pressure air.Fast images of the DBD are taken by using a charge couple device(CCD) cinema with a macro lens,while the electrical and photo-electricity waveforms of the DBD are recorded.The current waveforms show that under an applied voltage of 3 kV,there are numerous short current pulses in both positive and negative half-periods of discharges.However,under 6 kV,there are still the numerous short current pulses in the positive half-periods,but only one wide current pulse in each negative half-period.This difference is also found in the photoelectric signals.The streamer,corona and glow discharges are observed from the images of the discharges at different applied voltages.The structure of glow discharge in the negative period is exactly the same as that of the low pressure glow discharge.However,in the positive period of discharge there is always a streamer.In the negative period of discharge,while the applied voltage increases,the transition from corona to glow discharge is observed.The progress of a transition between streamer and glow discharge at 6 kV during one period is analyzed.The glow discharge appearance is determined by two factors: the discharge current is limited to a certain extent by the dielectric layer; the charges deposited on the dielectric layer during the last half period enhance the intensity of the electric field.At an insufficient applied voltage,the cathode drop leads to no glow discharge,but Trichel pulses.展开更多
To simulate the electro-hydrodynamics of wire-plate corona discharge at different voltages accurately,a simulation method,which relates the definite radius and initial velocity of a jet source to the amplitude of disc...To simulate the electro-hydrodynamics of wire-plate corona discharge at different voltages accurately,a simulation method,which relates the definite radius and initial velocity of a jet source to the amplitude of discharge voltage,is developed.Firstly,a model of the electro-hydrodynamics is established by the Matlab software using the governing equations discretized with the finite difference method.Secondly,the electric field strength and current density are simulated and the radius and initial velocity of a jet source at different voltages are determined.Finally,the discharge electro-hydrodynamics is simulated using the determined boundary conditions.Compared with using a conventional method,using the proposed method can obtain a wind velocity with smaller errors from the experimental and theoretical wind velocities: the errors between simulated wind velocity and its theoretical counter part at 45 kV and 50 kV decrease from 9% and 6.25% to 1.7% and 1.56%,respectively.Thus,the proposed method is feasible for the existing discharge models.展开更多
For the purpose of testing and analysing the corona characteristics of UHVDC bundle conductors, UHVDC corona cage would be built in China. Corona cage is one of the indispensable equipments for conductor corona perfor...For the purpose of testing and analysing the corona characteristics of UHVDC bundle conductors, UHVDC corona cage would be built in China. Corona cage is one of the indispensable equipments for conductor corona performance researches. Tests of conductor co- rona characteristics in corona cages can overcome the shortages of those with test lines.The dimensions of several corona cages constructed overseas were introduced in this paper. Based on foreign experiences and the requirement of State Grid Corporation of China, the UHVDC corona cage was designed as double-cage, double-layer, three-sections, and catenary shape with the size of 70 m×22 m×13 m. The corona loss measurement system, radio interference measuring system, and the audible noise measuring system are also detailed, including the measurement theory, connection with the cage, the parameters and the designing basis. The UHVDC corona cage has been put into service. It now undergoes a large amount of audible noise and radio frequency interference tests.展开更多
文摘In this paper a fully parametrized finite element simulation model of the stator bar end is created using the COMSOL Multiphysics.The model allows conducting the comparison of different corona protection structures’design,various materials properties,and finally optimizing the corona protection system.Several samples of SiC based nonlinear conductivity materials for corona protection were fabricated in laboratory and then investigated.The conductivity dependencies on electric field(0.05 to 1 kV/mm)and temperature(20 to 155℃)were measured.By comparing the heat-resistant grades of the corona protection material and the insulating material,the maximum working temperature of the corona protection material corresponds to the heat-resistant grade F of the insulating material.As the temperature increases,the nonlinear characteristics of the corona protection material in the experiment decrease dramatically,reducing the heat-resistant grade of the corona protection material.The decrease in the nonlinear characteristics of the corona protection material at the maximum operating temperature causes the maximum electric field strength at the end of the HV rotating machines end corona protection(ECP)exceeding the corona discharge electric field strength,resulting in corona phenomenon.
文摘利用解密的美国CORONA卫星影像,在库车冲断褶皱带,开展大面积地表构造调查,获取地区的地表产状.通过建立有理函数模型(rational function model,RFM)校正CORONA影像的全景变形,利用JX-4C数字摄影测量系统进行CORONA影像的立体观测和测量,确定岩层面的高程值,并采用三点法在MATLAB软件中计算岩层的倾角和走向,获取地表产状.通过和野外实测数据对比,测量误差小于3°,满足了构造定量解析的精度要求.应用获取的构造产状结合二维地震反射资料,根据断层相关褶皱原理定量地提取库车地区褶皱和断层的几何学特征.
基金Supported by the China-Russia Joint Research Center on Space Weather, Chinese Academy of Sciences
文摘The white-light corona calibrated data with processing level L1 from the LASCO-C2/SOHO instrument, and data from the Wind spacecraft with one-hour and one-minute time resolution on quasi-stationary slow (v between 300-450 km/s at the Earth's orbit) the Solar Wind (SW) parameters in the absence of sporadic SW streams are examined. Within distances from the Sun's center less than R in the range of 20-30 Rs,(Rs, the solar radius), slow wind is known as the streamer belt, and at larger distances it is called the Heliospheric Plasma Sheet (HPS). It is shown that the streamer belt comprises a sequence of pairs of rays. In general, ray brightnesses in each pair can differ, and the magnetic field is oppositely directed in them. The neutral line of the radial magnetic field of the Sun runs along the belt between the rays of each of the pairs.The area in which the streamer belt intersects the ecliptic plane and which lies at the central meridian, will be recorded at the earth's orbit with a time delay of 5-6 days, in the form of one or several peaks with Nmax > 10 cm-3. Furthermore, the simplest density profile of the portion of the HCS has the form of two peaks of a different or identical amplitude . The such a profile is observed in cases where the angle of intersection of the streamer belt with the ecliptic plane near the Sun is sufficiently large, i.e. close to 90°. The two-ray structure of the cross-section of the streamer-belt moves from the Sun to the Earth, it retains not only the angular size of the peaks but also the relative density variations, and the position of the neutral line(sector boundary) in between. At the Earth's orbit the ray structure of the streamer belt provides the source for sharp (i.e. with steep fronts of a duration of a few minutes or shorter) solar wind plasma density peaks (of a duration of several hours) with maximum values Nmax > 10 cm-3.
基金Supported by the National Natural Science Foundation of China (40536029, 40336053, 40374056, 40574068) and the International Collaboration Research Team Program of the Chinese Academy of Sciences
文摘Considerable progress for the study of solar corona physics has been achieved by China's space physics community. It involves the theoretical study of coronal process of solar active phenomena, solar wind origin, acceleration of solar wind and coronal mass ejections, observational and numerical study of these problems and prediction methods of solar eruptive activities (such as flares/CMEs). Here is a brief summary of the progress in this area. Main progress is put upon the following three topics: corona and solar wind, numerical method, prediction method.
文摘Abnormal voltages such as electrostatic,constant current,and strong electromagnetic signals can erroneously trigger operation of MEMS pyrotechnics and control systems in a fuze,which may result in casualties.This study designs a solid-state micro-scale switch by combining the corona gas discharge theory of asymmetric electric fields and Peek’s Law.The MEMS switch can be transferred from“off”to“on”through the gas breakdown between the corona electrodes.In the model,one of the two electrodes is spherical and the other flat,so a non-uniform electric field is formed around the electrodes.The theoretical work is as follows.First,the relation among the radius of curvature of the spherical electrode,the discharge gap,and the air breakdown voltage is obtained;to meet the low voltage(30-60 V)required to drive the MEMS switch,the radius of curvature of the spherical electrode needs to be 10 e50 mm and the discharge gap between the two electrodes needs to be 9e11 mm.Second,the optimal ratioεis introduced to parameterize the model.Finally,the corona discharge structural parameters are determined by comparing the theoretical and electric field simulation results.The switch is then fabricated via MEMS processing.A hardware test platform is built and the performing chip tested.It is found that when the electrode gap is 9 mm,the electrostatic voltage is at least 37.3 V,with an error of 2.6%between the actual and theoretical air breakdown voltages.When the electrode gap is 11 mm,the electrostatic voltage is at least 42.3 V,with an error of 10.5%between the actual and theoretical air breakdown voltages.Both cases meet the design requirements.
基金Project Supported by UHV Transmission and Transformation System Development and Demonstration Program of National Key Tech-nology R&D Program(2006BAA02A04)
文摘Corona discharge is being detected by UV imaging detection technology at home and abroad in recent years.This technology is used in the corona tests of conductor bundles in this paper.In order to further research the corona characteristic,optimize geometry parameters and diameter of sub-conductor,and increase corona onset voltage of transmission lines,corona tests of three model conductors which are placed inside the outdoor corona cage are conducted.Corona cage could be used to simulate the corona activities on transmission lines under a low voltage and different conditions in an effective and economical way.Photon which was created by UV light as a result of corona discharge on conductors is detected by the UV detection apparatus.The photon number within unit interval,namely photon counting rate is adopted as the parameter of quantifying the intensity of corona discharge.According to the apparent change of photon number,corona onset voltage can be judged.All tests are conducted under almost same atmosphere condition.Using the method,corona onset voltage is acquired.The results indicate that the tests have a good repeatability,in other words,repeating same test twice same result can be aquired.The corona onset voltage can be acquired exactly from the curve of applied voltage vs.photon counting rate.Therefore UV detection apparatus can not only used to find discharge point exactly,but also applied on corona discharge research and live detection for power equipments.The method using in this paper is proved that is a new available method.
基金supported by National High-tech Research and Development Program of China(863 Program)(2012AA062609)National Twelfth-five Year Science and Technology Supporting Program of China(2013BAC06B02)+1 种基金Special Fund for Marine Scientific Research in the Public Interest(201305027-5)Fundamental Research Fund for the Central Universities(3132013316)
文摘To discuss the modes of dielectric barrier discharge(DBD) between needle-to-plane electrodes in air,DBD is generated and observed on a needle-to-plane device at atmospheric pressure air.Fast images of the DBD are taken by using a charge couple device(CCD) cinema with a macro lens,while the electrical and photo-electricity waveforms of the DBD are recorded.The current waveforms show that under an applied voltage of 3 kV,there are numerous short current pulses in both positive and negative half-periods of discharges.However,under 6 kV,there are still the numerous short current pulses in the positive half-periods,but only one wide current pulse in each negative half-period.This difference is also found in the photoelectric signals.The streamer,corona and glow discharges are observed from the images of the discharges at different applied voltages.The structure of glow discharge in the negative period is exactly the same as that of the low pressure glow discharge.However,in the positive period of discharge there is always a streamer.In the negative period of discharge,while the applied voltage increases,the transition from corona to glow discharge is observed.The progress of a transition between streamer and glow discharge at 6 kV during one period is analyzed.The glow discharge appearance is determined by two factors: the discharge current is limited to a certain extent by the dielectric layer; the charges deposited on the dielectric layer during the last half period enhance the intensity of the electric field.At an insufficient applied voltage,the cathode drop leads to no glow discharge,but Trichel pulses.
基金Project supported by National Natural Science Foundation of China (10875036), Hebei Provincial Natural Science Foundation of China (A2010000182), Hebei Provincial Science and Technology Supporting Program of China (09276712D).
文摘To simulate the electro-hydrodynamics of wire-plate corona discharge at different voltages accurately,a simulation method,which relates the definite radius and initial velocity of a jet source to the amplitude of discharge voltage,is developed.Firstly,a model of the electro-hydrodynamics is established by the Matlab software using the governing equations discretized with the finite difference method.Secondly,the electric field strength and current density are simulated and the radius and initial velocity of a jet source at different voltages are determined.Finally,the discharge electro-hydrodynamics is simulated using the determined boundary conditions.Compared with using a conventional method,using the proposed method can obtain a wind velocity with smaller errors from the experimental and theoretical wind velocities: the errors between simulated wind velocity and its theoretical counter part at 45 kV and 50 kV decrease from 9% and 6.25% to 1.7% and 1.56%,respectively.Thus,the proposed method is feasible for the existing discharge models.
基金Project supported by National Basic Research Program of China (973 Program) (2011CB209402)
文摘For the purpose of testing and analysing the corona characteristics of UHVDC bundle conductors, UHVDC corona cage would be built in China. Corona cage is one of the indispensable equipments for conductor corona performance researches. Tests of conductor co- rona characteristics in corona cages can overcome the shortages of those with test lines.The dimensions of several corona cages constructed overseas were introduced in this paper. Based on foreign experiences and the requirement of State Grid Corporation of China, the UHVDC corona cage was designed as double-cage, double-layer, three-sections, and catenary shape with the size of 70 m×22 m×13 m. The corona loss measurement system, radio interference measuring system, and the audible noise measuring system are also detailed, including the measurement theory, connection with the cage, the parameters and the designing basis. The UHVDC corona cage has been put into service. It now undergoes a large amount of audible noise and radio frequency interference tests.