期刊文献+
共找到159篇文章
< 1 2 8 >
每页显示 20 50 100
Study of optical clocks based on ultracold ^171Yb atoms 被引量:3
1
作者 Di Ai Hao Qiao +8 位作者 Shuang Zhang Li-Meng Luo Chang-Yue Sun Sheng Zhang Cheng-Quan Peng Qi-Chao Qi Tao-Yun Jin Min Zhou Xin-Ye Xu 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第9期79-83,共5页
The optical atomic clocks have the potential to transform global timekeeping,relying on the state-of-the-art accuracy and stability,and greatly improve the measurement precision for a wide range of scientific and tech... The optical atomic clocks have the potential to transform global timekeeping,relying on the state-of-the-art accuracy and stability,and greatly improve the measurement precision for a wide range of scientific and technological applications.Herein we report on the development of the optical clock based on 171Yb atoms confined in an optical lattice.A minimum width of 1.92-Hz Rabi spectra has been obtained with a new 578-nm clock interrogation laser.The in-loop fractional instability of the 171Yb clock reaches 9.1×10-18 after an averaging over a time of 2.0×104 s.By synchronous comparison between two clocks,we demonstrate that our 171Yb optical lattice clock achieves a fractional instability of 4.60×10-16/√τ. 展开更多
关键词 cold ytterbium atoms optical clocks ultra-stable clock lasers clock-transition spectra instability and uncertainty
在线阅读 下载PDF
Laboratory demonstration of geopotential measurement using transportable optical clocks 被引量:1
2
作者 刘道信 曹健 +6 位作者 袁金波 崔凯枫 袁易 张平 晁思嘉 舒华林 黄学人 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第1期272-277,共6页
We report an experimental demonstration of geopotential difference measurement using a pair of transportable ^(40)Ca^(+) optical clocks(TOC-729-1 and TOC-729-3)in the laboratory,each of them has an uncertainty of 1.3&... We report an experimental demonstration of geopotential difference measurement using a pair of transportable ^(40)Ca^(+) optical clocks(TOC-729-1 and TOC-729-3)in the laboratory,each of them has an uncertainty of 1.3×10^(−17) and an instability of 4.8×10^(−15)/√τ.Referenced to a stationary clock of TOC-729-1,the geopotential difference measurements are realized by moving TOC-729-3 to three different locations and the relevant altitude differences are measured with uncertainties at the level of 20 cm.After correcting the systematic shifts(including gravitational red shift),the two-clock frequency difference is measured to be–0.7(2.2)×10^(−17),considering both the statistic(1.0×10^(−17))and the systematic(1.9×10^(−17))uncertainties.The frequency difference between these two clocks is within their respective uncertainties,verifying the reliability of transportable ^(40)Ca^(+) optical clocks at the low level of 10^(−17). 展开更多
关键词 geopotential difference measurement transportable optical clock repeatability evaluation of clocks
在线阅读 下载PDF
Direct Laser Cooling Al^+ Ion Optical Clocks 被引量:1
3
作者 张洁 邓科 +1 位作者 罗俊 陆泽晃 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第5期31-35,共5页
The Al^+ ion optical clock is a very promising optical frequency standard candidate due to its extremely small black-body radiation shift. It has been successfully demonstrated with the indirect cooled, quantum-logic... The Al^+ ion optical clock is a very promising optical frequency standard candidate due to its extremely small black-body radiation shift. It has been successfully demonstrated with the indirect cooled, quantum-logic-based spectroscopy technique. Its accuracy is limited by second-order Doppler shift, and its stability is limited by the number of ions that can be probed in quantum logic processing. We propose a direct laser cooling scheme of AI+ ion optical clocks where both the stability and accuracy of the clocks are greatly improved. In the proposed scheme, two Al^+ traps are utilized. The first trap is used to trap a large number of Al^+ ions to improve the stability of the clock laser, while the second trap is used to trap a single Al^+ ion to provide the ultimate accuracy. Both traps are cooled with a continuous wave 167nm laser. The expected clock laser stability can reach 9.0 × 10^-17/√τ. For the second trap, in addition to 167nm laser Doppler cooling, a second stage pulsed 234nm two-photon cooling laser is utilized to further improve the accuracy of the clock laser. The total systematic uncertainty can be reduced to about 1 × 10^-18. The proposed Al^+ ion optical clock has the potential to become the most accurate and stable optical clock. 展开更多
关键词 Direct Laser Cooling Al Ion Optical clocks
在线阅读 下载PDF
Review of chip-scale atomic clocks based on coherent population trapping 被引量:10
4
作者 汪中 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第3期47-58,共12页
Research on chip-scale atomic clocks (CSACs) based on coherent population trapping (CPT) is reviewed. The back- ground and the inspiration for the research are described, including the important schemes proposed t... Research on chip-scale atomic clocks (CSACs) based on coherent population trapping (CPT) is reviewed. The back- ground and the inspiration for the research are described, including the important schemes proposed to improve the CPT signal quality, the selection of atoms and buffer gases, and the development of micro-cell fabrication. With regard to the re- liability, stability, and service life of the CSACs, the research regarding the sensitivity of the CPT resonance to temperature and laser power changes is also reviewed, as well as the CPT resonance's collision and light of frequency shifts. The first generation CSACs have already been developed but its characters are still far from our expectations. Our conclusion is that miniaturization and power reduction are the most important aspects calling for further research. 展开更多
关键词 chip-scale atomic clock coherent population trapping
在线阅读 下载PDF
Cold atom clocks and their applications in precision measurements 被引量:5
5
作者 Shao-Yang Dai Fa-Song Zheng +4 位作者 Kun Liu Wei-Liang Chen Yi-Ge Lin Tian-Chu Li Fang Fang 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第1期27-41,共15页
Cold atom clocks have made remarkable progresses in the last two decades and played critical roles in precision measurements. Primary Cs fountain frequency standards have achieved a total uncertainty of a few parts in... Cold atom clocks have made remarkable progresses in the last two decades and played critical roles in precision measurements. Primary Cs fountain frequency standards have achieved a total uncertainty of a few parts in 1016, and the best optical clock has reached a type B uncertainty below 10-18. Besides applications in the metrology, navigation, etc.,ultra-stable and ultra-accurate atomic clocks have also become powerful tools in the basic scientific investigations. In this paper, we focus on the recent developments in the high-performance cold atomic clocks which can be used as frequency standards to calibrate atomic time scales. The basic principles, performances, and limitations of fountain clocks and optical clocks based on signal trapped ion or neutral atoms are summarized. Their applications in metrology and other areas are briefly introduced. 展开更多
关键词 atomic fountain clock optical clock
在线阅读 下载PDF
Stable ^(85)Rb micro vapour cells:fabrication based on anodic bonding and application in chip-scale atomic clocks 被引量:3
6
作者 苏娟 邓科 +4 位作者 郭等柱 汪中 陈兢 张耿民 陈徐宗 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第11期243-250,共8页
We describe the microfabrication of ^85Rb vapour cells using a glass-silicon anodic bonding technique and in situ chemical reaction between rubidium chloride and barium azide to produce Rb. Under controlled conditions... We describe the microfabrication of ^85Rb vapour cells using a glass-silicon anodic bonding technique and in situ chemical reaction between rubidium chloride and barium azide to produce Rb. Under controlled conditions, the pure metallic Rb drops and buffer gases were obtained in the cells with a few mm^3 internal volumes during the cell sealing process. At an ambient temperature of 90 ℃ the optical absorption resonance of ^85Rb D1 transition with proper broadening and the corresponding coherent population trapping (CPT) resonance, with a signal contrast of 1.5% and linewidth of about 1.7 kHz, have been detected. The sealing quality and the stability of the cells have also been demonstrated experimentally by using the helium leaking detection and the after-9-month optoelectronics measurement which shows a similar CPT signal as its original status. In addition, the physics package of chip-scale atomic clock (CSAC) based on the cell was realized. The measured frequency stability of the physics package can reach to 2.1 × 10^-10 at one second when the cell was heated to 100 ℃ which proved that the cell has the quality to be used in portable and battery-operated devices. 展开更多
关键词 ^85Rb Micro vapour cell anodic bonding coherent population trapping chip-scale atomic clock frequency stability
在线阅读 下载PDF
All polarization-maintaining Er:fiber-based optical frequency comb for frequency comparison of optical clocks 被引量:1
7
作者 Pan Zhang Yan-Yan Zhang +7 位作者 Ming-Kun Li Bing-Jie Rao Lu-Lu Yan Fa-Xi Chen Xiao-Fei Zhang Qun-Feng Chen Hai-Feng Jiang Shou-Gang Zhang 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第5期364-369,共6页
We demonstrate an optical frequency comb(OFC)based on a turnkey mode-locked laser with a figure-9-shape structure and polarization-maintaining fibers,for the comparison of frequency among optical clocks with wavelengt... We demonstrate an optical frequency comb(OFC)based on a turnkey mode-locked laser with a figure-9-shape structure and polarization-maintaining fibers,for the comparison of frequency among optical clocks with wavelengths of 698 nm,729 nm,1068 nm,and 1156 nm.We adopt a multi-branch approach in order to produce high power OFC signals at these specific wavelengths,enabling the signal-to-noise ratio of the beatnotes between the OFC and the clock lasers to exceed30 d B at a resolution bandwidth of 300 k Hz.This approach makes the supercontinuum spectra much easier to be generated than a single branch OFC.However,more out-of-loop fibers degrade the long-term frequency instability due to thermal drift.To minimize the thermal drift effect,we set the fiber lengths of different branches to be similar,and we stabilize the temperature as well.The out-of-loop frequency instability of the OFC due to the incoherence of the multi-branch is about5.5×10^(19) for 4000 s,while the in-loop frequency instability of fceo and that of fbeat are 7.5×10^(18) for 1 s and 8.5×10^(18) for 1 s,respectively.The turnkey OFC meets the requirement for the comparison of frequency between the best optical clocks. 展开更多
关键词 optical frequency comb nonlinear amplifying loop mirror optical clock frequency instability
在线阅读 下载PDF
Development of adjustable permanent magnet Zeeman slowers for optical lattice clocks 被引量:3
8
作者 张晓航 徐信业 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第5期102-107,共6页
We develop a permanent-magnet Zeeman slower with adjustable magnets along the longitudinal and radial directions.Produced by four arrays of cylindrical magnets, the longitudinal magnetic field in the slower is tunable... We develop a permanent-magnet Zeeman slower with adjustable magnets along the longitudinal and radial directions.Produced by four arrays of cylindrical magnets, the longitudinal magnetic field in the slower is tunable if relevant parameters vary, for example, laser detuning or intensity. The proposed Zeeman slower can be reconfigured for Sr atoms. Additionally,we demonstrate that the residual magnetic field produced by the permanent magnets in the magneto-optical trap region can be as small as 0.5 Gs. 展开更多
关键词 permanent magnet slower adjustable longitudinal dipole tunable clock directions captured
在线阅读 下载PDF
Ramsey-CPT spectrum with the Faraday effect and its application to atomic clocks
9
作者 田原 谭伯仲 +2 位作者 杨晶 张奕 顾思洪 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第6期279-283,共5页
A method that obtains the Ramsey-coherent population trapping (CPT) spectrum with the Faraday effect is investi- gated. An experiment is implemented to detect the light polarization components generated from the Far... A method that obtains the Ramsey-coherent population trapping (CPT) spectrum with the Faraday effect is investi- gated. An experiment is implemented to detect the light polarization components generated from the Faraday effect. The experimental results agree with the theoretical calculations based on the Liouville equation. By comparing with the method without using the Faraday effect, the potential of this method for a CPT-based atomic clock is assessed. The results indicate that this method should improve the short-term frequency stability by several times. 展开更多
关键词 Faraday effect Ramsey-CPT atomic clock frequency stability
在线阅读 下载PDF
Theoretical calculations of hyperfine splitting,Zeeman shifts,and isotope shifts of^(27)Al^(+)and logical ions in Al^(+)clocks
10
作者 Xiao-Kang Tang Xiang Zhang +1 位作者 Yong Shen Hong-Xin Zou 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第12期361-369,共9页
Based on the multiconfiguration Dirac-Hartree-Fock(MCDHF)method,similar models are employed to simultaneously calculate the first-order and second-order Zeeman coefficients as well as the hyperfine interaction constan... Based on the multiconfiguration Dirac-Hartree-Fock(MCDHF)method,similar models are employed to simultaneously calculate the first-order and second-order Zeeman coefficients as well as the hyperfine interaction constants of the related energy levels of ^(27)Al^(+)and its logical ions ^(9)Be^(+)and^(25)Mg^(+)in the^(27)Al^(+)optical clock.With less than 0.34%deviations from experimental values in Zeeman coefficients of^(27)Al^(+),these calculated parameters will be of great help for better evaluation of the systematic uncertainty.We also calculate the isotope shift parameters of the related energy levels,which could extend our knowledge and understanding of nuclear properties of these ions. 展开更多
关键词 Zeeman effect isotope shift aluminum ion optical clock MCDHF method
在线阅读 下载PDF
Measurements of Majorana transition frequency shift in caesium atomic fountain clocks
11
作者 施俊如 王心亮 +6 位作者 杨帆 白杨 管勇 范思晨 刘丹丹 阮军 张首刚 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第4期42-49,共8页
The caesium atomic fountain clock is a primary frequency standard.During its operation,a Majorana transition frequency shift will occur once a magnetic field at some special locations along the atomic trajectory is si... The caesium atomic fountain clock is a primary frequency standard.During its operation,a Majorana transition frequency shift will occur once a magnetic field at some special locations along the atomic trajectory is singular.In this study,by developing a physical model,we analyzed the magnetic field requirements for atomic adiabatic transition and calculated the influence of the Majorana atomic transition on the atomic state via a quantum method.Based on the simulation results for the magnetic field in the fountain clock,we applied the Monte Carlo method to simulate the relationship between the Majorana transition frequency shift and the magnetic field at the entrance of the magnetic shielding,as well as the initial atomic population.Measurement of the Majorana transition frequency shift was realized by state-selecting asymmetrically populated atoms.The relationship between the Majorana transition frequency shift and the axial magnetic field at the entrance of the magnetic shielding was obtained.The measured results were essentially consistent with the calculated results.Thus,the magnetic field at the entrance of the magnetic shielding was configured,and the Majorana transition frequency shift of the fountain clock was calculated to be 4.57×10^(-18). 展开更多
关键词 caesium atomic fountain clock Majorana transition frequency shift magnetic field initial atomic population
在线阅读 下载PDF
Theoretical calculations on Landé g-factors and quadratic Zeeman shift coefficients of nsnp ^(3)P_(0)^(o) clock states in Mg and Cd optical lattice clocks
12
作者 卢本全 常宏 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第1期278-285,共8页
The study of magnetic field effects on the clock transition of Mg and Cd optical lattice clocks is scarce.In this work,the hyperfine-induced Landég-factors and quadratic Zeeman shift coefficients of the nsnp ^(3)... The study of magnetic field effects on the clock transition of Mg and Cd optical lattice clocks is scarce.In this work,the hyperfine-induced Landég-factors and quadratic Zeeman shift coefficients of the nsnp ^(3)P_(0)^(o) clock states for ^(111,113)Cd and ^(25)Mg were calculated by using the multi-configuration Dirac–Hartree–Fock theory.To obtain accurate values of these parameters,the impact of electron correlations and furthermore the Breit interaction and quantum electrodynamical effects on the Zeeman and hyperfine interaction matrix elements,and energy separations were investigated in detail.We also estimated the contributions from perturbing states to the Landég-factors and quadratic Zeeman shift coefficients concerned so as to truncate the summation over the perturbing states without loss of accuracy.Our calculations provide important data for estimating the first-and second-order Zeeman shifts of the clock transition for the Cd and Mg optical lattice clocks. 展开更多
关键词 optical lattice clock hyperfine-induced Landég-factor quadratic Zeeman shift coefficient Mg and Cd
在线阅读 下载PDF
An optimized ion trap geometry to measure quadrupole shifts of ^(171)Yb~+ clocks
13
作者 N Batra B K Sahoo S De 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第11期230-237,共8页
We propose a new ion-trap geometry to carry out accurate measurements of the quadrupole shifts in the (171)Yb ion.This trap will minimize the quadrupole shift due to the harmonic component of the confining potential... We propose a new ion-trap geometry to carry out accurate measurements of the quadrupole shifts in the (171)Yb ion.This trap will minimize the quadrupole shift due to the harmonic component of the confining potential by an order of magnitude.This will be useful to reduce the uncertainties in the clock frequency measurements of the 6s 2S(1/2)→4f(13)6s2 2F(7/2)and 6s 2S(1/2)→5d2D(3/2) transitions,from which we can deduce the precise values of the quadrupole moments(0s) of the 4f(13)6s2 2F(7/2) and 5d2D(3/2) states.Moreover,it may be able to affirm the validity of the measured 0 value of the4f(13)6s22F(7/2) state,for which three independent theoretical studies defer almost by one order of magnitude from the measurement.We also calculate 0s using the relativistic coupled-cluster(RCC) method.We use these 0 values to estimate the quadrupole shift that can be measured in our proposed ion trap experiment. 展开更多
关键词 validity minimize carry clock relativistic precise deduce magnitude expectation spatially
在线阅读 下载PDF
A Yb optical clock with a lattice power enhancement cavity 被引量:1
14
作者 王春云 姚远 +3 位作者 师浩森 于洪浮 马龙生 蒋燕义 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期70-74,共5页
We construct a power enhancement cavity to form an optical lattice in an ytterbium optical clock.It is demonstrated that the intra-cavity lattice power can be increased by about 45 times,and the trap depth can be as l... We construct a power enhancement cavity to form an optical lattice in an ytterbium optical clock.It is demonstrated that the intra-cavity lattice power can be increased by about 45 times,and the trap depth can be as large as 1400Er when laser light with a power of only 0.6 W incident to the lattice cavity.Such high trap depths are the key to accurate evaluation of the lattice-induced light shift with an uncertainty down to~1×10-18.By probing the ytterbium atoms trapped in the power-enhanced optical lattice,we obtain a 4.3 Hz-linewidth Rabi spectrum,which is then used to feedback to the clock laser for the close loop operation of the optical lattice clock.We evaluate the density shift of the Yb optical lattice clock based on interleaving measurements,which is-0.46(62)mHz.This result is smaller compared to the density shift of our first Yb optical clock without lattice power enhancement cavity mainly due to a larger lattice diameter of 344μm. 展开更多
关键词 optical atomic clock optical lattice optical cavity Stark shift
在线阅读 下载PDF
广电行业PTP系统的同步机选型及应用问题探讨 被引量:2
15
作者 薄蔚 《影视制作》 2024年第4期90-95,共6页
本文阐述了IP化广播电视制播系统使用PTP的必要性、PTP的相关标准以及基本工作原理,从产品选型角度对目前主流同步机产品进行性能对比,对视频系统PTP+BB混合模式、音频系统的PTP+Word Clock或BB同步方式以及远程制作的同步问题进行研究... 本文阐述了IP化广播电视制播系统使用PTP的必要性、PTP的相关标准以及基本工作原理,从产品选型角度对目前主流同步机产品进行性能对比,对视频系统PTP+BB混合模式、音频系统的PTP+Word Clock或BB同步方式以及远程制作的同步问题进行研究探讨。 展开更多
关键词 PTP 主从同步 BMAC PTP+BB Word Clock
在线阅读 下载PDF
Physics package based on intracavity laser cooling ^(87)Rb atoms for space cold atom microwave clock
16
作者 邓思敏达 任伟 +9 位作者 项静峰 赵剑波 李琳 张迪 万金银 孟艳玲 蒋小军 李唐 刘亮 吕德胜 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第7期22-26,共5页
This article proposes a new physics package to enhance the frequency stability of the space cold atom clock with the advantages of a microgravity environment. Clock working processes, including atom cooling, atomic st... This article proposes a new physics package to enhance the frequency stability of the space cold atom clock with the advantages of a microgravity environment. Clock working processes, including atom cooling, atomic state preparation,microwave interrogation, and transition probability detection, are integrated into the cylindrical microwave cavity to achieve a high-performance and compact physics package for the space cold atom clock. We present the detailed design and ground-test results of the cold atom clock physics package in this article, which demonstrates a frequency stability of 1.2×10^(-12) τ^(-1/2) with a Ramsey linewidth of 12.5 Hz, and a better performance is predicted with a 1 Hz or a narrower Ramsey linewidth in microgravity environment. The miniaturized cold atom clock based on intracavity cooling has great potential for achieving space high-precision time-frequency reference in the future. 展开更多
关键词 atomic clock MICROGRAVITY microwave cavity space station frequency stability
在线阅读 下载PDF
A redundant subspace weighting procedure for clock ensemble
17
作者 徐海 陈煜 +1 位作者 刘默驰 王玉琢 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第4期435-442,共8页
A redundant-subspace-weighting(RSW)-based approach is proposed to enhance the frequency stability on a time scale of a clock ensemble.In this method,multiple overlapping subspaces are constructed in the clock ensemble... A redundant-subspace-weighting(RSW)-based approach is proposed to enhance the frequency stability on a time scale of a clock ensemble.In this method,multiple overlapping subspaces are constructed in the clock ensemble,and the weight of each clock in this ensemble is defined by using the spatial covariance matrix.The superimposition average of covariances in different subspaces reduces the correlations between clocks in the same laboratory to some extent.After optimizing the parameters of this weighting procedure,the frequency stabilities of virtual clock ensembles are significantly improved in most cases. 展开更多
关键词 weighting method redundant subspace clock ensemble time scale
在线阅读 下载PDF
Piperine regulates the circadian rhythms of hepatic clock gene expressions and gut microbiota in high-fat diet-induced obese rats
18
作者 Weiyun Zhang Chi-Tang Ho +2 位作者 Wenlian Wei Jie Xiao Muwen Lu 《Food Science and Human Wellness》 SCIE CSCD 2024年第3期1617-1627,共11页
The interplay between the host circadian clock and microbiota has significant influences on host metabolism processes,and circadian desynchrony triggered by high-fat diet(HFD)is closely related to metabolic disorders.... The interplay between the host circadian clock and microbiota has significant influences on host metabolism processes,and circadian desynchrony triggered by high-fat diet(HFD)is closely related to metabolic disorders.In this study,the modulatory effects of piperine(PIP)on lipid metabolism homeostasis,gut microbiota community and circadian rhythm of hepatic clock gene expressions in obese rats were investigated.The Sprague-Dawley(SD)rats were fed with normal diet(ND),HFD and HFD supplemented with PIP,respectively.After 9 weeks,rats were sacrificed with tissue and fecal samples collected for circadian analysis.Results showed that chronic PIP administration ameliorated the obesity-induced alterations in lipid metabolism and dysregulation of hepatic clock gene expressions in obese rats.The gut microbial communities studied through 16S rRNA sequencing showed that PIP ameliorated the imbalanced nicrobiota and recovered the circadian rhythm of Lactobacillaceae,Desulfovibrionaceae,Paraprevotellaceae,and Lachnospiraceae.The fecal metabolic profiles indicated that 3-dehydroshikimate,cytidine and lithocholyltaurine were altered,which were involved in the amino acid and fatty acid metabolism process.These findings could provide theoretical basis for PIP to work as functional food to alleviate the lipid metabolism disorder,circadian rhythm misalignment,and gut microbiota dysbiosis with wide applications in the food and pharmaceutic industries. 展开更多
关键词 PIPERINE Circadian clock OBESITY Gut microbiota
在线阅读 下载PDF
Capsaicin alleviates the hepatic clock gene disruption and gut microbiota dysbiosis in circadian rhythm disorder mouse model
19
作者 Bolin Lin Chi-Tang Ho +2 位作者 Yawen Wang Jie Xiao Muwen Lu 《Food Science and Human Wellness》 SCIE CAS CSCD 2024年第5期2947-2958,共12页
As the body’s internal clock,the circadian rhythm regulates the energy expenditure,appetite,and sleep.There exists a close relationship between the host circadian rhythm and gut microbiota.In this work,a circadian di... As the body’s internal clock,the circadian rhythm regulates the energy expenditure,appetite,and sleep.There exists a close relationship between the host circadian rhythm and gut microbiota.In this work,a circadian disorder mouse model induced by constant darkness(CD)was constructed to investigate the regulating effects of capsaicin(CAP)on disturbances of metabolism homeostasis and gut microbiota in the respect of circadian rhythm-related mechanisms.Our results indicated that CAP reduced weight gain induced by circadian rhythm disorder in mice by inhibiting fat accumulation in liver and adipose tissue.The rhythmic expressions of circadian clock genes and lipid-metabolism related genes in liver were also recovered by CAP.Microbial study using 16S rRNA sequencing revealed that CAP modulated the gut microbiota richness,diversity and composition,and restored diurnal oscillations of gut microbes at the phylum and family level.These results indicated that CAP could alleviate CD-induced hepatic clock gene disruption and gut microbiota dysbiosis in mice,providing theoretical basis for CAP to be used as a muti-functional ingredient with great healthpromoting effects. 展开更多
关键词 CAPSAICIN Circadian rhythm Hepatic clock gene Gut microbiota Lipid dysregulation
在线阅读 下载PDF
Proposal for a realtime Einstein-synchronization-defined satellite virtual clock
20
作者 严晨皓 汤雪逸 +4 位作者 王时光 孟李皎悦 孙海媛 何奕彬 王力军 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第7期268-276,共9页
Realization of high performance satellite onboard clock is vital for various positioning, navigation, and timing applications. For further improvement of the synchronization-based satellite time and frequency referenc... Realization of high performance satellite onboard clock is vital for various positioning, navigation, and timing applications. For further improvement of the synchronization-based satellite time and frequency references, we propose a geosynchronous(GEO) satellite virtual clock concept based on ground–satellite synchronization and present a beacon transponder structure for its implementation(scheduled for launch in 2025), which does not require atomic clocks to be mounted on the satellite. Its high performance relies only on minor modifications to the existing transponder structure of GEO satellites. We carefully model the carrier phase link and analyze the factors causing link asymmetry within the special relativity. Considering that performance of such synchronization-based satellite clocks is primarily limited by the link's random phase noise, which cannot be adequately modeled, we design a closed-loop experiment based on commercial GEO satellites for pre-evaluation. This experiment aims at extracting the zero-means random part of the ground-satellite Ku-band carrier phase via a feedback loop. Ultimately, we obtain a 1σ value of 0.633 ps(two-way link), following the Gaussian distribution. From this result, we conclude that the proposed real-time Einstein-synchronization-defined satellite virtual clock can achieve picosecond-level replication of onboard time and frequency. 展开更多
关键词 Einstein synchronization satellite virtual clock geosynchronous satellite carrier phase
在线阅读 下载PDF
上一页 1 2 8 下一页 到第
使用帮助 返回顶部