期刊文献+
共找到14篇文章
< 1 >
每页显示 20 50 100
Silicon photomultiplier based scintillator thermal neutron detector for China Spallation Neutron Source(CSNS) 被引量:1
1
作者 岳秀萍 朱志甫 +11 位作者 唐彬 黄畅 于潜 陈少佳 王修库 许虹 周诗慧 蔡小杰 杨浩 万志勇 孙志嘉 刘云涛 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第9期35-41,共7页
The energy-resolved neutron imaging spectrometer(ERNI)will be installed in 2022 according to the spectrometer construction plan of the China Spallation Neutron Source(CSNS).The instrument requires neutron detectors wi... The energy-resolved neutron imaging spectrometer(ERNI)will be installed in 2022 according to the spectrometer construction plan of the China Spallation Neutron Source(CSNS).The instrument requires neutron detectors with the coverage area of approximately 4 m^(2)in 5°-170°neutron diffraction angle.The neutron detection efficiency needs to be better than 40%at 1 A neutron wavelength.The spatial resolution should be better than 3 mm×50 mm in the horizontal and vertical directions respectively.We develop a one-dimensional scintillator neutron detector which is composed of the^(6)Li F/Zn S(Ag)scintillation screens,the wavelength-shifting fiber(WLSF)array,the silicon photomultipliers(Si PMs),and the self-designed application-specific integrated circuit(ASIC)readout electronics.The pixel size of the detector is designed as 3 mm×50 mm,and the neutron-sensitive area is 50 mm×200 mm.The performance of the detector prototype is measured using neutron beam 20#of the CSNS.The maximum counting rate of 247 k Hz,and the detection efficiency of63%at 1.59 A are obtained.The test results show that the performance of the detector fulfills the physical requirements of the ERNI under construction at the CSNS. 展开更多
关键词 neutron detector silicon photomultipliers(SiPMs) ^(6)LiF/ZnS(Ag) China spallation neutron source(csns)
在线阅读 下载PDF
Analysis of displacement damage effects on the charge-coupled device induced by neutrons at Back-n in the China Spallation Neutron Source 被引量:2
2
作者 薛院院 王祖军 +9 位作者 陈伟 郭晓强 姚志斌 何宝平 聂栩 赖善坤 黄港 盛江坤 马武英 缑石龙 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第7期435-442,共8页
Displacement damage effects on the charge-coupled device(CCD)induced by neutrons at the back-streaming white neutron source(Back-n)in the China Spallation Neutron Source(CSNS)are analyzed according to an online irradi... Displacement damage effects on the charge-coupled device(CCD)induced by neutrons at the back-streaming white neutron source(Back-n)in the China Spallation Neutron Source(CSNS)are analyzed according to an online irradiation experiment.The hot pixels,random telegraph signal(RTS),mean dark signal,dark current and dark signal non-uniformity(DSNU)induced by Back-n are presented.The dark current is calculated according to the mean dark signal at various integration times.The single-particle displacement damage and transient response are also observed based on the online measurement data.The trends of hot pixels,mean dark signal,DSNU and RTS degradation are related to the integration time and irradiation fluence.The mean dark signal,dark current and DSNU2 are nearly linear with neutron irradiation fluence when nearly all the pixels do not reach saturation.In addition,the mechanisms of the displacement damage effects on the CCD are demonstrated by combining the experimental results and technology computer-aided design(TCAD)simulation.Radiation-induced traps in the space charge region of the CCD will act as generation/recombination centers of electron-hole pairs,leading to an increase in the dark signal. 展开更多
关键词 displacement damage effects charge-coupled device(CCD) China spallation neutron source(csns) MECHANISMS technology computer-aided design(TCAD)
在线阅读 下载PDF
Measurement of the relative neutron sensitivity curve of a LaBr_(3)(Ce)scintillator based on the CSNS Back-n white neutron source
3
作者 刘建 王东明 +3 位作者 甫跃成 李忠宝 易晗 易龙涛 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第10期66-72,共7页
A scintillator detector consisting of a LaBr_(3)(Ce)(0.5%)scintillator,a photomultiplier tube(PMT),and an oscilloscope were used to study the neutron sensitivities of the LaBr_(3)(Ce)scintillator at the China Spallati... A scintillator detector consisting of a LaBr_(3)(Ce)(0.5%)scintillator,a photomultiplier tube(PMT),and an oscilloscope were used to study the neutron sensitivities of the LaBr_(3)(Ce)scintillator at the China Spallation Neutron Source(CSNS)Back-n white neutron source in the double-bunch and single-bunch operation modes,respectively.Under the two operational modes,the relative neutron sensitivity curves of the LaBr_(3)(Ce)scintillator in the energy regions of 1–20 MeV and 0.5–20 MeV were obtained for the first time.In the energy range of 1–20 MeV,the two curves were nearly identical.However the relative neutron sensitivity uncertainties of the double-bunch experiment were higher than those of the single-bunch experiment.The above results indicated that the single-bunch experiment's neutron sensitivity curve has a lower minimum measurable energy than the double-bunch experiment.Above the minimum measurable energy of the double-bunch experiment,there is little difference between the measured relative neutron sensitivity curves of the single-bunch and double-bunch experiments of the LaBr_(3)(Ce)scintillator and those of other scintillators with a similar neutron response signal intensity. 展开更多
关键词 relative neutron sensitivity LaBr_(3)(Ce) China spallation neutron source(csns) white neutron source
在线阅读 下载PDF
Analysis of displacement damage effects on bipolar transistors irradiated by spallation neutrons 被引量:3
4
作者 Yan Liu Wei Chen +5 位作者 Chaohui He Chunlei Su Chenhui Wang Xiaoming Jin Junlin Li Yuanyuan Xue 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第6期372-377,共6页
Displacement damage induced by neutron irradiation in China Spallation Neutron Source(CSNS) is studied on bipolar transistors with lateral PNP, substrate PNP, and vertical NPN configurations, respectively. Comparison ... Displacement damage induced by neutron irradiation in China Spallation Neutron Source(CSNS) is studied on bipolar transistors with lateral PNP, substrate PNP, and vertical NPN configurations, respectively. Comparison of the effects on different type transistors is conducted based on displacement damage factor, and the differences are analyzed through minority carrier lifetime calculation and structure analysis. The influence of CSNS neutrons irradiation on the lateral PNP transistors is analyzed by the gate-controlled method, including the oxide charge accumulation, surface recombine velocity,and minority carrier lifetime. The results indicate that the total ionizing dose in CSNS neutron radiation environment is negligible in this study. The displacement damage factors based on 1-MeV equivalent neutron flux of different transistors are consistent between Xi’an pulse reactor(XAPR) and CSNS. 展开更多
关键词 DISPLACEMENT damage China spallation neutron source(csns) reactor neutrons BIPOLAR TRANSISTORS
在线阅读 下载PDF
Measurements of the ^(107)Ag neutron capture cross sections with pulse height weighting technique at the CSNS Back-n facility 被引量:3
5
作者 Xin-Xiang Li Long-Xiang Liu +28 位作者 Wei Jiang Jie Ren Hong-Wei Wang Gong-Tao Fan Jian-Jun He Xi-Guang Cao Long-Long Song Yue Zhang Xin-Rong Hu Zi-Rui Hao Pan Kuang Bing Jiang Xiao-He Wang Ji-Feng Hu Jin-Cheng Wang De-Xin Wang Su-Yalatu Zhang Ying-Du Liu Xu Ma Chun-Wang Ma Yu-Ting Wang Zhen-Dong An Jun Su Li-Yong Zhang Yu-Xuan Yang Wen-Bo Liu Wan-Qing Su Sheng Jin Kai-Jie Chen 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第3期109-116,共8页
Silver indium cadmium(Ag–In–Cd) control rod is widely used in pressurized water reactor nuclear power plants,and it is continuously consumed in a high neutron flux environment. The mass ratio of ^(107)Ag in the Ag... Silver indium cadmium(Ag–In–Cd) control rod is widely used in pressurized water reactor nuclear power plants,and it is continuously consumed in a high neutron flux environment. The mass ratio of ^(107)Ag in the Ag–In–Cd control rod is 41.44%. To accurately calculate the consumption value of the control rod, a reliable neutron reaction cross section of the ^(107)Ag is required. Meanwhile,^(107)Ag is also an important weak r nucleus. Thus, the cross sections for neutron induced interactions with ^(107)Ag are very important both in nuclear energy and nuclear astrophysics. The(n, γ) cross section of ^(107)Ag has been measured in the energy range of 1–60 eV using a back streaming white neutron beam line at China spallation neutron source. The resonance parameters are extracted by an R-matrix code. All the cross section of ^(107)Ag and resonance parameters are given in this paper as datasets. The datasets are openly available at http://www.doi.org/10.11922/sciencedb.j00113.00010. 展开更多
关键词 neutron capture cross section pulse height weighting technique(PHWT) ^(107)Ag(n γ)^(108)Ag the China spallation neutron source(csns)Back-n facility
在线阅读 下载PDF
基于嵌入式IOC的CSNS真空控制系统样机研制 被引量:3
6
作者 何泳成 王春红 +3 位作者 王金灿 吴煊 王晓黎 黄涛 《核电子学与探测技术》 CAS CSCD 北大核心 2013年第3期280-283,共4页
在EPICS软件框架下搭建了一套中国散裂中子源(CSNS)真空控制系统样机。使用MOXA嵌入式工控机运行嵌入式Linux系统,并建立相应的EPICS系统,实现EPICS与真空设备(真空计和离子泵电源控制器)的接口。真空连锁保护系统则用横河PLC实现,并在... 在EPICS软件框架下搭建了一套中国散裂中子源(CSNS)真空控制系统样机。使用MOXA嵌入式工控机运行嵌入式Linux系统,并建立相应的EPICS系统,实现EPICS与真空设备(真空计和离子泵电源控制器)的接口。真空连锁保护系统则用横河PLC实现,并在该PLC的嵌入式Linux控制器模块上建立EPICS系统,使PLC中的数据直接纳入EPICS系统中。通过测试表明,该样机实时性较高且稳定可靠。 展开更多
关键词 中国散裂中子源 真空控制系统 嵌入式输入输出控制器 实验物理及工业控制系统
在线阅读 下载PDF
CSNS强流负氢离子源及其改进 被引量:2
7
作者 刘盛进 欧阳华甫 +5 位作者 黄涛 肖永川 曹秀霞 吕永佳 薛康佳 陈卫东 《原子能科学技术》 EI CAS CSCD 北大核心 2019年第9期1719-1723,共5页
中国散裂中子源(CSNS)的离子源是1台强流负氢离子源,该离子源负氢束流的能量为50keV,负氢流强可达40mA,束流占空比最高为1.25%(重复频率为25Hz,脉宽为500μs)。目前该负氢离子源已投入到CSNS中使用。由于等离子体放电电极受带电粒子溅... 中国散裂中子源(CSNS)的离子源是1台强流负氢离子源,该离子源负氢束流的能量为50keV,负氢流强可达40mA,束流占空比最高为1.25%(重复频率为25Hz,脉宽为500μs)。目前该负氢离子源已投入到CSNS中使用。由于等离子体放电电极受带电粒子溅射的缘故,在1.5%(25Hz,600μs)的占空比、负氢流强30mA运行下,离子源的寿命约为30d。为提高离子源使用的稳定性,对离子源进行改进优化,提高了离子源的运行效率和稳定性。 展开更多
关键词 中国散裂中子源 质子加速器 强流负氢离子源
在线阅读 下载PDF
CSNS 加速器一键开关机程序设计和实现 被引量:1
8
作者 李明涛 张玉亮 +5 位作者 袁月 吴煊 薛康佳 王林 何泳成 朱鹏 《强激光与粒子束》 CAS CSCD 北大核心 2023年第8期119-124,共6页
中国散裂中子源加速器上有几百套电源和高频设备。每次开关机过程都要通过操作二十多个控制界面来完成这几百台设备的开关机流程,过程繁琐,耗时较多,容易出错且很难发现。为了简化开关机流程和避免人为错误发生,开发了一套一键开关机程... 中国散裂中子源加速器上有几百套电源和高频设备。每次开关机过程都要通过操作二十多个控制界面来完成这几百台设备的开关机流程,过程繁琐,耗时较多,容易出错且很难发现。为了简化开关机流程和避免人为错误发生,开发了一套一键开关机程序。该程序将分散于二十多个界面的所有硬件设备开关机操作集成到一个界面中,同时将每个硬件开关机流程抽象为单独线程,界面上一键操作,使用多线程并发完成所有设备的开关机操作。该程序实现了运行模式状态的一键存储和恢复,能够一键完成整个加速器的开关机流程,将原来耗时40 min的开关机流程压缩到约2 min完成,提升了操作效率,很好地满足了中国散裂中子源加速器运行需求。该程序具有一定的通用性,可以在其它装置推广应用。 展开更多
关键词 csns 控制系统 实验物理与工业控制系统 一键开关机 模式存储和恢复
在线阅读 下载PDF
基于信号幅度的^(3)He管中子探测器刻度算法优化研究
9
作者 许宇涵 修青磊 +8 位作者 殷伟刚 肖亮 蒋孟奇 周晓娟 赖彦玲 王艳凤 周健荣 孙志嘉 魏亚东 《核电子学与探测技术》 CAS 北大核心 2024年第2期372-379,共8页
本研究针对中国散裂中子源下的高压中子衍射谱仪中核心组件——位置灵敏型^(3)He管中子探测器的刻度问题进行了深入探究。通过实验验证和理论分析,揭示了传统刻度方法中未考虑到的中子信号幅度对刻度参数的影响,以及由此产生的位置分布... 本研究针对中国散裂中子源下的高压中子衍射谱仪中核心组件——位置灵敏型^(3)He管中子探测器的刻度问题进行了深入探究。通过实验验证和理论分析,揭示了传统刻度方法中未考虑到的中子信号幅度对刻度参数的影响,以及由此产生的位置分布畸变和空间分辨率降低的问题。为解决这些问题,本研究提出了一种改进的刻度算法,该算法能够有效地考虑中子信号幅度的变化,从而显著改善了探测器系统的空间分辨能力。经过实验结果分析显示,新的刻度算法不仅消除了位置分布的拖尾现象,而且提高了不同位置处的空间分辨率,与理论预期相符。本研究的成果为高压中子衍射谱仪在极端条件下的应用提供了重要的技术支持,并为进一步优化中子探测器的刻度方法和提高中子衍射技术的应用精度奠定了基础。 展开更多
关键词 中国散裂中子源 高压中子衍射谱仪 位置灵敏型~3He管中子探测器 刻度算法 空间分辨 非线性效应
在线阅读 下载PDF
中国散裂中子源靶站中子通道初步屏蔽计算分析 被引量:1
10
作者 张斌 陈义学 +1 位作者 杨寿海 殷雯 《原子能科学技术》 EI CAS CSCD 北大核心 2010年第2期210-214,共5页
基于中国散裂中子源靶站中子通道设计,采用二维离散纵标程序DORT对中子导出通道各种设计方案的屏蔽效果进行计算分析。计算得出二维剂量场分布及通道中心处剂量当量率轴向分布,并得到较优化的屏蔽方案及模型,确保谱仪大厅内工作人员接... 基于中国散裂中子源靶站中子通道设计,采用二维离散纵标程序DORT对中子导出通道各种设计方案的屏蔽效果进行计算分析。计算得出二维剂量场分布及通道中心处剂量当量率轴向分布,并得到较优化的屏蔽方案及模型,确保谱仪大厅内工作人员接受的剂量低于规定的标准。结果表明,未安装谱仪的中子通道屏蔽模型中心含有SS316合金钢时的屏蔽效果较好,剂量在辐射防护标准以下,符合设计要求。中子孔道开闭装置屏蔽模型中前端加入钨板屏蔽效果较好,并随钨板长度的增加,屏蔽效果提高。 展开更多
关键词 中国散裂中子源 中子导出通道 离散纵标法 屏蔽
在线阅读 下载PDF
环-靶站输运线末端准直器的研究 被引量:1
11
作者 王梓豪 屈化民 +1 位作者 朱东辉 王海静 《强激光与粒子束》 EI CAS CSCD 北大核心 2015年第5期277-280,共4页
环-靶站输运线(RTBT)末端的准直器是中国散裂中子源(CSNS)工程中的关键部件之一,因其靠近靶站,辐射剂量大,维护困难,故设计可靠性极为重要。根据准直器的工作原理,及CSNS物理设计要求,对比国外同类加速器的设计经验,设计完成准直器设备... 环-靶站输运线(RTBT)末端的准直器是中国散裂中子源(CSNS)工程中的关键部件之一,因其靠近靶站,辐射剂量大,维护困难,故设计可靠性极为重要。根据准直器的工作原理,及CSNS物理设计要求,对比国外同类加速器的设计经验,设计完成准直器设备。在设计过程中兼顾了热沉积、功率损耗和材料性能等方面的严格要求,并逐一阐述了具体方案。利用Bethe-Bloch公式计算与SRIM软件模拟的结果比较,确定了模拟工具和模拟方法的可靠性,根据ANSYS有限元软件模拟的结果,验证了准直器结构设计的可靠性。 展开更多
关键词 中国散裂中子源 准直器 热沉积 热分析 可靠性分析
在线阅读 下载PDF
特殊科研用地总平面设计探讨—以中国散裂中子源实验园区为例 被引量:1
12
作者 孙礼军 廖雄 潘智伟 《规划师》 北大核心 2015年第11期67-70,共4页
国家大科学装置实验园区作为一种特殊的科研用地,在总平面设计上与一般的科学园区不同,对其设计进行研究具有重要意义。基于此,文章对国家大科学装置实验园区的设计原则进行分析,结合中国散裂中子源实验园区设计案例,从总体设计、道路... 国家大科学装置实验园区作为一种特殊的科研用地,在总平面设计上与一般的科学园区不同,对其设计进行研究具有重要意义。基于此,文章对国家大科学装置实验园区的设计原则进行分析,结合中国散裂中子源实验园区设计案例,从总体设计、道路交通设计、绿化景观设计和建筑设计等方面探讨国家大科学装置实验园区总平面设计方法,以期为类似项目提供借鉴。 展开更多
关键词 国家大科学装置 中国散裂中子源 实验园区 设计
在线阅读 下载PDF
基于欠采样技术的束流相位测量电子学系统设计
13
作者 彭卫 吴兵 +2 位作者 徐韬光 李武建 李鹏 《强激光与粒子束》 EI CAS CSCD 北大核心 2017年第6期103-107,共5页
采用欠采样技术为中国散裂中子源(CSNS)直线加速器研制了全数字化束流相位测量电子学系统。介绍了该系统的测量原理、整体设计情况,并进行了实验测试。测试采用324 MHz,100 mVpp的正弦信号,测试结果显示相位分辨率优于0.1°,通道间... 采用欠采样技术为中国散裂中子源(CSNS)直线加速器研制了全数字化束流相位测量电子学系统。介绍了该系统的测量原理、整体设计情况,并进行了实验测试。测试采用324 MHz,100 mVpp的正弦信号,测试结果显示相位分辨率优于0.1°,通道间相位不一致性可控制在±0.2°以内,满足设计指标要求。 展开更多
关键词 束流相位测量 欠采样 ADC 中国散裂中子源
在线阅读 下载PDF
中国散裂中子源氦容器安装技术
14
作者 李继红 倪晓晔 +1 位作者 冯光 郑乐见 《施工技术》 CAS 2020年第23期134-136,141,共4页
中国散裂中子源(CSNS)氦容器在国内为首次安装,其安装的质量将直接影响中子的试验效率。主要介绍了CSNS氦容器安装的难点和方案选择,进行了双机抬吊方案的汽车式起重机、索具选型的相关计算。经过精心组织施工,解决了超重精密设备在空... 中国散裂中子源(CSNS)氦容器在国内为首次安装,其安装的质量将直接影响中子的试验效率。主要介绍了CSNS氦容器安装的难点和方案选择,进行了双机抬吊方案的汽车式起重机、索具选型的相关计算。经过精心组织施工,解决了超重精密设备在空中姿态改变和远距离精确安装就位等难题。 展开更多
关键词 中国散裂中子源 氦容器 双机抬吊法 姿态改变 安装
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部