Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Base...Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Based on CCTA data of the stenosed left anterior descending branch(LAD)in a patient with coronary heart disease,an 0D-1D coupling model and 3D FSI model were built,respectively.Then hemodynamic characteristic indexes,including the pressure,flow velocity and wall shear stress(WSS)were obtained in every 0.01 s during 1 s at 5 sampling points(i.e.sampling point 1—5)using these 2 models,respectively,and the consistencies of the results between models were evaluated with Spearman correlation coefficient r s.Results The time consuming for construction of 0D-1D coupling model and 3D FSI model was 0.033 min and 704 min,respectively.Both models showed basically distribution of the pressure,flow velocity and WSS of the stenosed LAD.For more details,the pressure at the stenosed segment of LAD and the proximal segment of stenosis were both higher,which gradually decreased at the distal segment of stenosis,and the flow velocity at the proximal segment of stenosis was in a relatively slow and uniform condition,with significantly increased flow velocity and WSS at the stenosed segment.Compared with 3D FSI model,0D-1D vascular coupling model was relatively unrefined and lack of distal flow lines when displaying blood flow velocity.For sampling point 2 at the stenosed segment of LAD,no significant consistency for pressure between 2 models was found(P=0.118),but strong consistency for the flow velocity and WSS(r s=0.730,0.807,both P<0.05).The consistencies of pressure,flow velocity and WSS between 2 models at the proximal and distal segment of stenosis,i.e.1,3—5 sampling points were week to moderate(r s=0.237—0.669,all P<0.05).Conclusion 0D-1D coupling model exhibited outstanding computational efficiency and might provide relatively reasonable results,while 3D FSI model showed higher accuracy for details and streamline when simulating LAD stenosis.展开更多
患者女,60岁,间断劳累后胸闷伴心悸、出汗、恶心1周,休息20~30 min后可缓解;7年前无明显诱因晕厥1次,未接受系统诊治;高血压病史2年,规律用药。查体:血压150/105 mm Hg,心肺查体未见明显异常。实验室检查及心电图未见明显异常。超声心动...患者女,60岁,间断劳累后胸闷伴心悸、出汗、恶心1周,休息20~30 min后可缓解;7年前无明显诱因晕厥1次,未接受系统诊治;高血压病史2年,规律用药。查体:血压150/105 mm Hg,心肺查体未见明显异常。实验室检查及心电图未见明显异常。超声心动图:左心室舒张末期容积118 ml,左心室舒张功能减低。展开更多
文摘Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Based on CCTA data of the stenosed left anterior descending branch(LAD)in a patient with coronary heart disease,an 0D-1D coupling model and 3D FSI model were built,respectively.Then hemodynamic characteristic indexes,including the pressure,flow velocity and wall shear stress(WSS)were obtained in every 0.01 s during 1 s at 5 sampling points(i.e.sampling point 1—5)using these 2 models,respectively,and the consistencies of the results between models were evaluated with Spearman correlation coefficient r s.Results The time consuming for construction of 0D-1D coupling model and 3D FSI model was 0.033 min and 704 min,respectively.Both models showed basically distribution of the pressure,flow velocity and WSS of the stenosed LAD.For more details,the pressure at the stenosed segment of LAD and the proximal segment of stenosis were both higher,which gradually decreased at the distal segment of stenosis,and the flow velocity at the proximal segment of stenosis was in a relatively slow and uniform condition,with significantly increased flow velocity and WSS at the stenosed segment.Compared with 3D FSI model,0D-1D vascular coupling model was relatively unrefined and lack of distal flow lines when displaying blood flow velocity.For sampling point 2 at the stenosed segment of LAD,no significant consistency for pressure between 2 models was found(P=0.118),but strong consistency for the flow velocity and WSS(r s=0.730,0.807,both P<0.05).The consistencies of pressure,flow velocity and WSS between 2 models at the proximal and distal segment of stenosis,i.e.1,3—5 sampling points were week to moderate(r s=0.237—0.669,all P<0.05).Conclusion 0D-1D coupling model exhibited outstanding computational efficiency and might provide relatively reasonable results,while 3D FSI model showed higher accuracy for details and streamline when simulating LAD stenosis.
文摘患者女,60岁,间断劳累后胸闷伴心悸、出汗、恶心1周,休息20~30 min后可缓解;7年前无明显诱因晕厥1次,未接受系统诊治;高血压病史2年,规律用药。查体:血压150/105 mm Hg,心肺查体未见明显异常。实验室检查及心电图未见明显异常。超声心动图:左心室舒张末期容积118 ml,左心室舒张功能减低。