The Accelerator Driven Sub-critical(ADS)system is a strategic plan to solve the nuclear waste problem for nuclear power plants in China.High-energy particle accelerators and colliders contain long strings of supercond...The Accelerator Driven Sub-critical(ADS)system is a strategic plan to solve the nuclear waste problem for nuclear power plants in China.High-energy particle accelerators and colliders contain long strings of superconducting devices,superconducting radio frequency cavities,and magnets,which may require cooling by 2 K superfluid helium(HeliumⅡ).2 K superfluid helium cryogenic system has become a research hot spot in the field of superconducting accelerators.In this study,the ADS Injector-I 2 K cryogenic system is examined in detail.The cryogenic system scheme design,key equipment,and technology design,such as the 2 K Joule–Thomson(J–T)heat exchanger and cryomodules CM1+CM2 design,are examined,in addition to the commissioning and operation of the cryogenic system.The ADS Injector-I 2 K cryogenic system is the first 100 W superfluid helium system designed and built independently in China.The ADS proton beam reached 10 Me V at 10 m A in July 2016 and 10 Me V at 2 m A in continuous mode in January 2017 and has been operated reliably for over 15,000 h,proving that the design of ADS Injector-I 2 K cryogenic system,the key equipment,and technology research are reasonable,reliable,and meet the requirements.The research into key technologies provides valuable engineering experience that can be helpful for future projects such as CI-ADS(China Initiative Accelerator-Driven System),SHINE(Shanghai High Repetition Rate XFEL and Extreme Light Facility),PAPS(Platform of Advanced Photon Source Technology),and CEPC(Circular Electron-Positron Collider),thereby developing national expertise in the field of superfluid helium cryogenic systems.展开更多
We examine thermodynamic phase transition(PT)of the charged Gauss-Bonnet Ad S black hole(BH)by utilizing the shadow radius.In this system,we rescale the corresponding Gauss-Bonnet coefficientαby a factor of 1/(D-4),a...We examine thermodynamic phase transition(PT)of the charged Gauss-Bonnet Ad S black hole(BH)by utilizing the shadow radius.In this system,we rescale the corresponding Gauss-Bonnet coefficientαby a factor of 1/(D-4),and ensure thatαis positive to avoid any singularity problems.The equation derived for the shadow radius indicates that it increases as the event horizon radius increases,making it an independent variable for determining BH temperature.By investigating the PT curve in relation to shadows,we can observe that the shadow radius can be used as an alternative to the event horizon radius in explaining the phenomenon of BH PT.Furthermore,the results indicate that an increase in the parameterαcorresponds to a decrease in the temperature of the BH.By utilizing the relationship between the temperature and the shadow radius,it is possible to obtain the thermal profile of the Gauss-Bonnet AdS BH.It is evident that there is an N-type variation in temperature for pressures P<P_(c).Additionally,as the parameterαincreases,the region covered by shadow expands while the temperature decreases.The utilization of BH shadows as a probe holds immense significance in gaining a deeper understanding of BH thermodynamic behavior.展开更多
文摘The Accelerator Driven Sub-critical(ADS)system is a strategic plan to solve the nuclear waste problem for nuclear power plants in China.High-energy particle accelerators and colliders contain long strings of superconducting devices,superconducting radio frequency cavities,and magnets,which may require cooling by 2 K superfluid helium(HeliumⅡ).2 K superfluid helium cryogenic system has become a research hot spot in the field of superconducting accelerators.In this study,the ADS Injector-I 2 K cryogenic system is examined in detail.The cryogenic system scheme design,key equipment,and technology design,such as the 2 K Joule–Thomson(J–T)heat exchanger and cryomodules CM1+CM2 design,are examined,in addition to the commissioning and operation of the cryogenic system.The ADS Injector-I 2 K cryogenic system is the first 100 W superfluid helium system designed and built independently in China.The ADS proton beam reached 10 Me V at 10 m A in July 2016 and 10 Me V at 2 m A in continuous mode in January 2017 and has been operated reliably for over 15,000 h,proving that the design of ADS Injector-I 2 K cryogenic system,the key equipment,and technology research are reasonable,reliable,and meet the requirements.The research into key technologies provides valuable engineering experience that can be helpful for future projects such as CI-ADS(China Initiative Accelerator-Driven System),SHINE(Shanghai High Repetition Rate XFEL and Extreme Light Facility),PAPS(Platform of Advanced Photon Source Technology),and CEPC(Circular Electron-Positron Collider),thereby developing national expertise in the field of superfluid helium cryogenic systems.
基金Project supported by the National Natural Science Foundation of China (Grant No.11903025)the starting fund of China West Normal University (Grant No.18Q062)+2 种基金the Sichuan Youth Science and Technology Innovation Research Team (Grant No.21CXTD0038)the Chongqing Science and Technology Bureau (Grant No.cstc2022ycjh-bgzxm0161)the Natural Science Foundation of Sichuan Province (Grant No.2022NSFSC1833)。
文摘We examine thermodynamic phase transition(PT)of the charged Gauss-Bonnet Ad S black hole(BH)by utilizing the shadow radius.In this system,we rescale the corresponding Gauss-Bonnet coefficientαby a factor of 1/(D-4),and ensure thatαis positive to avoid any singularity problems.The equation derived for the shadow radius indicates that it increases as the event horizon radius increases,making it an independent variable for determining BH temperature.By investigating the PT curve in relation to shadows,we can observe that the shadow radius can be used as an alternative to the event horizon radius in explaining the phenomenon of BH PT.Furthermore,the results indicate that an increase in the parameterαcorresponds to a decrease in the temperature of the BH.By utilizing the relationship between the temperature and the shadow radius,it is possible to obtain the thermal profile of the Gauss-Bonnet AdS BH.It is evident that there is an N-type variation in temperature for pressures P<P_(c).Additionally,as the parameterαincreases,the region covered by shadow expands while the temperature decreases.The utilization of BH shadows as a probe holds immense significance in gaining a deeper understanding of BH thermodynamic behavior.