The pile-supported subgrade has been widely used in high-speed railway construction in China.To investigate the ground vibrations of such composite foundation subjected to moving loads induced by high-speed trains(HST...The pile-supported subgrade has been widely used in high-speed railway construction in China.To investigate the ground vibrations of such composite foundation subjected to moving loads induced by high-speed trains(HSTs),three-dimensional(3D)finite element method(FEM)models involving the pile,pile cap and cushion are established.Validation of the proposed model is conducted through comparison of model predictions with the field measurements.On this basis,ground vibrations generated by HSTs under different train speeds as well as the ground vibration attenuation with the distance away from the track centerline are investigated.In addition,the effects of piles and pile elastic modulus on ground vibrations are well studied.Results show that the pile-reinforcement of the subgrade could significantly contribute to the reduction of ground vibrations.In particular,the increase of elastic modulus of pile could lead to consistent reduction of ground vibrations.However,when the pile elastic modulus is beyond 10 GPa,this benefit of pile-reinforcement on vibration isolation can hardly be increased further.展开更多
Dynamic analysis steps and general flow of fast lagrangian analysis of continua in 3 dimensions(FLAC3D) were discussed. Numerical simulation for influence of excavation and blasting vibration on stability of mined-out...Dynamic analysis steps and general flow of fast lagrangian analysis of continua in 3 dimensions(FLAC3D) were discussed. Numerical simulation for influence of excavation and blasting vibration on stability of mined-out area was carried out with FLAC3D. The whole analytical process was divided into two steps, including the static analysis and the dynamic analysis which were used to simulate the influence of excavation process and blasting vibration respectively. The results show that the shape of right upper boundary is extremely irregular after excavation, and stress concentration occurs at many places and higher tensile stress appears. The maximum tensile stress is higher than the tensile strength of rock mass, and surrounding rock of right roof will be damaged with tension fracture. The maximum displacement of surrounding rock is 4.75 mm after excavation. However, the maximum displacement increases to 5.47 mm after the blasting dynamic load is applied. And the covering area of plastic zones expands obviously, especially at the foot of right upper slope. The analytical results are in basic accordance with the observed results on the whole. Damage and disturbance on surrounding rock to some degree are caused by excavation, while blasting dynamic load increases the possibility of occurrence of dynamic instability and destruction further. So the effective supporting and vibration reducing measures should be taken during mining.展开更多
This manuscript presents the comprehensive study of thickness stretching effects on the free vibration,static stability and bending of multilayer functionally graded(FG)carbon nanotubes reinforced composite(CNTRC)nano...This manuscript presents the comprehensive study of thickness stretching effects on the free vibration,static stability and bending of multilayer functionally graded(FG)carbon nanotubes reinforced composite(CNTRC)nanoplates.The nanoscale and microstructure influences are considered through a modified nonlocal strain gradient continuum model.Based on power-law functions,four different patterns of CNTs distribution are considered in this analysis,a uniform distribution UD,FG-V CNTRC,FG-X CNTRC,and FG-O CNTRC.A 3D kinematic shear deformation theory is proposed to include the stretching influence,which is neglected in classical theories.Hamilton's principle is applied to derive the governing equations of motion and associated boundary conditions.Analytical solutions are developed based on Galerkin method to solve the governing equilibrium equations based on the generalized higher-order shear deformation theory and the nonlocal strain gradient theory and get the static bending,buckling loads,and natural frequencies of nanoplates.Verification with previous works is presented.A detailed parametric analysis is carried out to highlight the impact of thickness stretching,length scale parameter(nonlocal),material scale parameter(gradient),CNTs distribution pattern,geometry of the plate,various boundary conditions and the total number of layers on the stresses,deformation,critical buckling loads and vibration frequencies.Many new results are also reported in the current study,which will serve as a benchmark for future research.展开更多
输电塔主材改用复合材料,可有效减少输电线路占地,并减少电气间距达到压缩走廊的目的。复合材料区别于角钢,可以使用D字型截面,提高了截面惯性抵抗矩。对各规格复合材料构件的截面进行了有限元分析,计算得到了截面特性参数。以某110 k ...输电塔主材改用复合材料,可有效减少输电线路占地,并减少电气间距达到压缩走廊的目的。复合材料区别于角钢,可以使用D字型截面,提高了截面惯性抵抗矩。对各规格复合材料构件的截面进行了有限元分析,计算得到了截面特性参数。以某110 k V塔头复合材料塔为工程背景,建立了有限元模型,获得了其自振特性并与传统角钢塔做了对比,分析了参数不同的原因。使用基于时域法的风振系数计算,对位移均方根值、位移平均值、加速度均方根值的分布特点进行了研究,计算了各高度处的风振系数,并将结果与我国规范的取值进行了对比,结果可作为复合塔抗风设计的参考。展开更多
基金Project(51978510)supported by the National Natural Science Foundation of China。
文摘The pile-supported subgrade has been widely used in high-speed railway construction in China.To investigate the ground vibrations of such composite foundation subjected to moving loads induced by high-speed trains(HSTs),three-dimensional(3D)finite element method(FEM)models involving the pile,pile cap and cushion are established.Validation of the proposed model is conducted through comparison of model predictions with the field measurements.On this basis,ground vibrations generated by HSTs under different train speeds as well as the ground vibration attenuation with the distance away from the track centerline are investigated.In addition,the effects of piles and pile elastic modulus on ground vibrations are well studied.Results show that the pile-reinforcement of the subgrade could significantly contribute to the reduction of ground vibrations.In particular,the increase of elastic modulus of pile could lead to consistent reduction of ground vibrations.However,when the pile elastic modulus is beyond 10 GPa,this benefit of pile-reinforcement on vibration isolation can hardly be increased further.
基金Project (50490272) supported by the National Natural Science Foundation of China project(NCET-05-0687) supportedby Programfor New Century Excellent Talents project (040109) supported bythe Doctor Degree Paper Innovation Engineering of CentralSouth University
文摘Dynamic analysis steps and general flow of fast lagrangian analysis of continua in 3 dimensions(FLAC3D) were discussed. Numerical simulation for influence of excavation and blasting vibration on stability of mined-out area was carried out with FLAC3D. The whole analytical process was divided into two steps, including the static analysis and the dynamic analysis which were used to simulate the influence of excavation process and blasting vibration respectively. The results show that the shape of right upper boundary is extremely irregular after excavation, and stress concentration occurs at many places and higher tensile stress appears. The maximum tensile stress is higher than the tensile strength of rock mass, and surrounding rock of right roof will be damaged with tension fracture. The maximum displacement of surrounding rock is 4.75 mm after excavation. However, the maximum displacement increases to 5.47 mm after the blasting dynamic load is applied. And the covering area of plastic zones expands obviously, especially at the foot of right upper slope. The analytical results are in basic accordance with the observed results on the whole. Damage and disturbance on surrounding rock to some degree are caused by excavation, while blasting dynamic load increases the possibility of occurrence of dynamic instability and destruction further. So the effective supporting and vibration reducing measures should be taken during mining.
基金supported by The Algerian General Directorate of Scientific Research and Technological Development(DGRSDT)University of Mustapha Stambouli of Mascara(UMS Mascara)in Algeria。
文摘This manuscript presents the comprehensive study of thickness stretching effects on the free vibration,static stability and bending of multilayer functionally graded(FG)carbon nanotubes reinforced composite(CNTRC)nanoplates.The nanoscale and microstructure influences are considered through a modified nonlocal strain gradient continuum model.Based on power-law functions,four different patterns of CNTs distribution are considered in this analysis,a uniform distribution UD,FG-V CNTRC,FG-X CNTRC,and FG-O CNTRC.A 3D kinematic shear deformation theory is proposed to include the stretching influence,which is neglected in classical theories.Hamilton's principle is applied to derive the governing equations of motion and associated boundary conditions.Analytical solutions are developed based on Galerkin method to solve the governing equilibrium equations based on the generalized higher-order shear deformation theory and the nonlocal strain gradient theory and get the static bending,buckling loads,and natural frequencies of nanoplates.Verification with previous works is presented.A detailed parametric analysis is carried out to highlight the impact of thickness stretching,length scale parameter(nonlocal),material scale parameter(gradient),CNTs distribution pattern,geometry of the plate,various boundary conditions and the total number of layers on the stresses,deformation,critical buckling loads and vibration frequencies.Many new results are also reported in the current study,which will serve as a benchmark for future research.
文摘输电塔主材改用复合材料,可有效减少输电线路占地,并减少电气间距达到压缩走廊的目的。复合材料区别于角钢,可以使用D字型截面,提高了截面惯性抵抗矩。对各规格复合材料构件的截面进行了有限元分析,计算得到了截面特性参数。以某110 k V塔头复合材料塔为工程背景,建立了有限元模型,获得了其自振特性并与传统角钢塔做了对比,分析了参数不同的原因。使用基于时域法的风振系数计算,对位移均方根值、位移平均值、加速度均方根值的分布特点进行了研究,计算了各高度处的风振系数,并将结果与我国规范的取值进行了对比,结果可作为复合塔抗风设计的参考。